You are advised to read all the instructions in this manual carefully to become familiar with the right conditions
for the proper use of your dishwasher.
TECHNICAL INSTRUCTIONS:
These are intended for the qualified staff who are to install, commission and test the appliance and carry out any servicing and repairs.
INSTRUCTIONS FOR THE USER:
These provide recommendations for use, a description of the controls and the correct
procedures for cleaning and maintaining the dishwasher.
1 Precautions for safety and use
THIS MANUAL IS AN INTEGRAL PART OF THE DISHWASHER AND MUST ALWAYS BE KEPT WITH THE APPLIANCE.
THE DISHWASHER IS INTENDED ONLY FOR PROFESSIONAL USE BY TRAINED STAFF. IT IS DESIGNED TO WASH TABLEWARE (PLATES, CUPS, BOWLS, OVEN DISHES AND CUTLERY) AND SIMILAR ITEMS IN THE RESTAURANT AND INSTITUTIONAL CATERING SECTOR, AND COMPLIES WITH
THE INTERNATIONAL STANDARDS ON ELECTRICAL AND MECHANICAL SAFETY (CEI-EN-IEC 60335-2- 58/61770) AND ELECTROMAGNETIC COMPATIBILITY (CEI-IEC-EN 55014-1/-2, 61000-3;4, 50366).
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR INJURY OR DAMAGE CAUSED BY FAILURE TO COMPLY WITH THE ABOVE REGULATIONS OR DERIVING FROM INCORRECT USE, TAMPERING WITH EVEN JUST ONE PART OF THE APPLIANCE AND THE USE OF NON-ORIGINAL
SPARE PARTS.
THIS APPLIANCE IS TAGGED UNDER EUROPEAN DIRECTIVE 2002/96/EC ON WASTE ELECTRICAL AND
ELECTRONIC EQUIPMENT (WEE). BY MAKING SURE THAT THIS PRODUCT IS DISPOSED OF CORRECTLY THE USER HELPS TO PREVENT POTENTIAL DETRIMENTAL EFFECTS ON HEALTH AND THE ENVIRONMENT.
THE PRODUCT MUST NOT BE TREATED AS ORDINARY DOMESTIC WASTE BUT MUST BE CONSIGNED TO THE SPECIAL COLLECTION POINT FOR THE RECYCLING OF ELECTRICAL AND ELECTRONIC EQUIPMENT. WHEN DECOMMISSIONING THE APPLIANCE COMPLY WITH THE LOCAL WASTE DISPOSAL REGULATIONS. FOR FURTHER INFORMATION ON THE TREATMENT, RECOVERY AND RECYCLING OF THIS PRODUCT, CONTACT THE COMPETENT LOCAL OFFICE, THE DOMESTIC WASTE COLLECTION SERVICE, OR THE SHOP WHERE THE PRODUCT WAS PURCHASED.
POSITIONING, CONNECTIONS, COMMISSIONING, TROUBLESHOOTING AND
REPLACEMENT OF THE POWER SUPPLY CABLE MUST BE CARRIED OUT BY SKILLED STAFF.
THE APPLIANCE MUST BE IN COMPLIANCE WITH ELECTRICAL SYSTEM SAFETY
REGULATIONS.
SYMBOL ON THE PRODUCT OR IN THE TECHNICAL DOCUMENTATION INDICATES THAT THIS
NEVER PLACE SOLVENTS SUCH AS ALCOHOL OR TURPENTINE, WHICH MIGHT CAUSE AN EXPLOSION, INSIDE THE APPLIANCE. NEVER LOAD DISHES DIRTY WITH ASH, WAX OR PAINTS.
NEVER USE THE DISHWASHER OR ANY PART OF IT AS A LADDER, SUPPORT OR STAND FOR PEOPLE, ANIMALS OR ANY OBJECT. LEANING OR SITTING ON THE OPEN DOOR OF THE DISHWASHER MIGHT CAUSE IT TO TIP OVER, PUTTING PEOPLE IN DANGER. NEVER LEAVE THE DISHWASHER DOOR OPEN SINCE PEOPLE MIGHT TRIP OVER IT.
DO NOT DRINK ANY WATER LEFT IN THE DISHES OR DISHWASHER AT THE END OF THE WASHING PROGRAM.
THE APPLIANCE IS NOT SUITABLE FOR USE BY JUVENILES OR PERSONS WITH REDUCED PHYSICAL, SENSORIAL OR MENTAL CAPACITIES, OR THOSE WITHOUT THE NECESSARY KNOWLEDGE AND EXPERIENCE. SUCH PERSONS MAY ONLY USE THE APPLIANCE UNDER THE SUPERVISION OF A PERSON RESPONSIBLE FOR THEIR SAFETY.
2
2 Technical data
TECHNICAL DATA
Supply voltage V 400V 3N ~
- convertible to single-phase version V 230V -1N ~ Frequency Hz 50 Max. power absorption at 400V 3N ~ kW 6.8 Max. power absorption at 230V 1N ~ kW 2.8 Boiler heating element power at 400V 3N ~ kW 6.0 Boiler heating element power at 230V 1N ~ kW 2.0 Tank heating element power kW 0.8 Water intake pressure kPa (bar) 100-600 (1 ÷ 6) Water intake temperature °C 15°C – 60°C Water hardness (models with softener) °dF 15°dF-60°dF Rinse cycle water consumption I 3.5 Boiler capacity I 7 + 1 Tank capacity I 11 Standard cycle duration with intake water at 50°C s 90/150/240/variable Noise level dB(A) Degree of protection IPX 4 Net weight kg Power supply cable type ◄HAR► H07RN-F
Fuse A 4
400V 3N ~ 230V 1N ~
C S C S
2,8 kW --- --- 3x2,5 6,8 kW
5x2,5 16A 3P+N
--- ---
16A 1P+N
C = Power Supply Cable. S = Master Switch
3
LOWER BACK PANEL
R
FILLER HOSE
C Q
EARTH TERMINAL ELECTRICITY SUPPLY CABLE
E
PERISTALTIC HOSES
P
DRAIN HOSE
S
EXTERNAL DISPENSER POWER
T
SUPPLY CABLE ENTRY POINT
TERMINAL BOARD
M
3 Installation and positioning
INSTALLATION and POSITIONING
Bring the dishwasher to the installation site, remove the packaging and check the appliance and components for damage; any damage found must be reported to the transporter in writing. The packaging components (plastic bags, expanded polystyrene, nails, etc.) must not be left within reach of children and pets since they are potentially dangerous. All packaging materials used are environment-friendly. They can be kept without constituting any hazard, or may be disposed of at a specialist waste disposal centre. The plastic components suitable for recycling are marked as follows:
PE polyethylene: external packaging film, bag containing the instructions, protective bags.
PP polypropylene: straps. PS expanded polystyrene: corner guards, top of packaging.
Wooden and cardboard components can be disposed of in accordance with the relevant regulations. When the product is decommissioned it must not be dumped in the environment; it must be disposed of in accordance with the relevant regulations. All metal parts are in stainless steel and can be removed. The plastic parts are marked with the symbol identifying the material used.
Models with aquastop
The aquastop device prevents flooding in the event of water leaks. In these models, the water intake hose is fitted with a solenoid valve. Do not cut the hose and do not drop the solenoid valve into water. In the event of damage to the water intake hose, disconnect the appliance from the electricity supply.
POSITIONING:
Caution: the indoor system and premises in which equipment for institutions is installed must
comply with the relevant regulations.
The manufacturer declines all liability for direct or indirect injury or damage deriving from failure to comply with these regulations. Before installation, check that there are no objects or materials in the vicinity which may be damaged by steam or splashes of washing solution, or that any such items are suitably protected. Place the dishwasher in the chosen point and remove the protective film. Level the dishwasher (with the aid of a spirit level) on its adjustable feet to ensure that it is stable; all other mounting solutions must be approved by the manufacturer.
4
4 INSTALLATION INSTRUCTIONS FOR THE AFTER-SALES SERVICE
Water supply and drain connection:
The water pipelines and electricity supply cable lead out of the bottom right-hand
corner of the appliance. Connect the water intake hose to a connector with ¾” gas threaded fitting, fitting the filter A provided (in models with aquastop, the filter and ring-
nut form a single unit). The connection to the water mains must only be made with new hoses; the use of old
or worn hoses is not permitted.
The dynamic intake pressure must be between 1 and 6 bar; if it is higher, installation of a pressure reducer is recommended.
It is essential to fit a main stop tap on the water intake pipeline; the tap must be accessible after installation of the appliance, so do not install it behind the dishwasher.
The stated cycle duration refers to appliances supplied with hot water at 50°C.
If the appliance is supplied with cold water, the cycle duration might increase depending on the intake water temperature, since the dishwasher is fitted with the HTR system, which requires set temperature and pressure for rinsing.
Drainage:
The dishwasher is fitted with a drain pump and can operate with drain
connections on the floor or wall.
4.1 Water connection
If the drain connection is to an outlet with valve, the maximum height of the drain is reduced to 600 mm.
In all cases, after installation check that the drain is fully functional by pumping out the tank completely (P0 cycle).
Caution:
constricted or crushed after installation.
make sure that the intake and drain hoses are not bent,
5
4.1 Electrical connection
The dishwasher and any additional equipment must be connected to the electrical system by authorised, skilled staff, in accordance with the relevant regulations; also comply with the technical instructions for the connection. The total rated power is stated on the appliance’s technical data plate. The electrical protection devices fitted for the dishwasher must serve this appliance only. The user must have a master switch and a differential safety breaker, with rating suitable for the machine’s characteristics, installed on the electricity supply line in accordance with the relevant regulations. These switches must be installed close to the dishwasher, be easily accessible after installation, and provide complete disconnection from the electrical mains in overvoltage class III conditions.
Warning !!!
The dishwasher is always powered up unless the master switch is turned off.
Connect the appliance to the user’s earth system. The terminal for the connection is in the bottom
right-hand corner of the appliance.
The earth wire (PE) is yellow-green in colour, the neutral wire (N) is blue and the live wires (L1, L2,
L3) are black, grey and brown.
In the event of single-phase connection (230V-1N~) the connection to the electrical mains must be made using a cable with plug compliant with the relevant regulations..
IN THE EVENT OF DAMAGE TO THE SUPPLY CORD, HAVE IT REPLACED BY THE MANUFACTURER OR AN AUTHORIZED TECHNICAL SERVICE CENTRE IN ORDER TO AVOID ANY RISK.