For communication cables, use the parts listed below
(refer to the catalogue [M8/M12 Connector] CAT.EUS100-73-UK for details)
or order the product certified for the respective protocol (with M12 connector) separately.
Electro-Pneumatic Regulator
Series
ITV1000/2000/3000
Model
Maximum supply pressure
Minimum supply pressure
24 VDC ±10%, 12 to 15 VDC
Set pressure +0.1 MPa
Set pressure range
Note 1)
0.2 MPa
Input signal
Inputimpedance
Output pressuredisplay
Note 4)
Weight
Note 9)
Accuracy
Minimum unit
ITV10ITV20
ITV30
Ambient and fluid temperature
Enclosure
1.0 MPa
0.005 to 0.1 MPa0.005 to 0.5 MPa0.005 to 0.9 MPa
JIS Symbol
4 to 20 mA, 0 to 20 mA (Sink type)
0 to 5 VDC, 0 to 10 VDC
4 points
250
Ωor less
Note 6)
Approx. 6.5 kΩ
Approx. 2.7
kΩ
Linearity
Hysteresis
Repeatability
Sensitivity
Temperature characteristics
Power supply
VoltageCurrent
consumption
Within ±1% (Full span)
Within 0.5% (Full span)
Within
±0.5% (Full span)
Within 0.2% (Full span)
Within ±0.12% (Full span)/°C
±3% (Full span)
MPa: 0.01, kgf/cm
2
: 0.01, bar: 0.01, PSI: 0.1
Note 5)
, kPa: 1
0 to 50
°C (No condensation)
IP65
Approx. 250 g (without options)
Approx. 350 g (without options)
Approx. 645 g (without options)
NPN open collector output: Max. 30 V, 30 mA
PNP open collector output: Max. 30 mA
Power supply voltage 24 VDC type: 0.12 A or less
Power supply voltage 12 to 15 VDC type: 0.18 A or less
ITV105ITV205
ITV305
ITV103
ITV203
ITV303
ITV101
ITV201
ITV301
1 to 5 VDC (Load impedance: 1 kΩor more)
4 to 20 mA (Sink type) (Load impedance: 250
Ωor less)
Output accuracy within
±6% (Full span)
Input/output characteristics chart
Input signal (%F.S.)
0
0100
Output pressure
(MPa)
This range is outside of the control (output).
0.005MPa
Rated pressure
ITV3000Fieldbus-compatible
model
ITV2000ITV1000
Note 1) Please refer to Figure 1 for the relationship between set pressure and input. Because the maximum set pres-
sure differs for each pressure display, refer to Appendix 7.Additionally, refer to page 18 for the set pressure range by units of standard measured pressure.
Additionally, refer to page 18 as maximum set pressure differs on unit of standard measure.Note 2) 2-wire type 4 to 20 mA is not available. Power supply voltage (24 VDC or 12 to 15 VDC) is required.Note 3) Select either analogue output or switch output.
Further, when switch output is selected, select either NPN output or PNP output.Note
4)
Adjustment of numerical values such as the zero/span adjustment or preset input type is set based on the mi-
nimum units for output pressure display (e.g. 0.01 to 0.50 MPa). Note that the unit cannot be changed.Note 5) The minimum unit for 0.9 MPa (130 psi) types is 1 psi.Note 6)
Value for the state with no over current circuit included. If an allowance is provided for an over current circuit,
the input impedance varies depending on the input current. This
is 350 Ωor less for an input current of 20
mA DC.Note 7) The above characteristics are confined to the static state. When air is consumed on the output side, the pres-
sure may fluctuate.Note 8) For communication models, the maximum current consumption is 0.16 A or less.Note 9) For communication models, add roughly 80 g to the weight (100 g for the PROFIBUS DP).Note 10) The ITV1000 series is a non-grease model (Wetted parts).
Standard Specifications
Note 10)Note 10)Note 10)
Current type
Note 2)
Voltage type
Preset input
Current type
Voltage type
Preset input
Switchoutput
Analogueoutput
Output signal(monitor output)
Note 3)
Protocol
Version
Note 1)
Configulation file
Note 2)
I/O occupation area (input/output data)
Communication data resolution
Fail safe
Note 4)
Terminating resistance
Communication speed
Communication Specifications
Model
ITV00-CC
CC-Link
Ver 1.10
—
12 bit (4096 resolution)
ITV00-DN
DeviceNet™
Release2.0
EDS
16 bit/16 bit
12 bit (4096 resolution)
—
ITV00-PR
PROFIBUS DP
DP-V0
GSD
16 bit/16 bit
12 bit (4096 resolution)
CLEAR
ITV00-RC
RS-232C
—
9.6 kbps
—
—
10 bit (1024 resolution)
HOLD
—
Note 1) Note that this version information is subject to change.Note 2) Configulation files can be downloaded from SMC's website: http://www.smc.euNote 3) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data.Note 4) It shows the insulation between electric signal for communication and the ITV supply power.
156 k/625 k
2.5 M/5 M/10 M bps
125 k/250 k/500 k bps
9.6 k/19.2 k/45.45
k
93.75 k/187.5 k/500
k
1.5 M/3 M/6 M/12 M bps
Built into the product
(Switch setting)
HOLD/CLEAR
(Switch setting)
4 word/4 word, 32 bit/32 bit
(per station, remote device station)
HOLD
Note 3)
/CLEAR
(Switch setting)
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
9
Electro-Pneumatic Regulator
Standard Specifications
Series ITV1000/2000/3000
ITV2000ITV1000
ITV3000Fieldbus-compatible
model
JIS Symbol
Rated pressure
(MPa)
Output pressure
0.005MPa
0
This range is outside
of the control (output).
0100
Input signal (%F.S.)
Input/output characteristics chart
Communication Specifications
Note 10)Note 10)Note 10)
ITV101
Model
Minimum supply pressure
Maximum supply pressure
Set pressure range
Note 1)
Voltage
Power supply
Current
consumption
Note 2)
Current type
Input signal
Voltage type
ITV201
ITV301
Set pressure +0.1 MPa
0.2 MPa
0.005 to 0.1 MPa0.005 to 0.5 MPa0.005 to 0.9 MPa
24 VDC ± 10%, 12 to 15 VDC
Power supply voltage 24 VDC type: 0.12 A or less
Power supply voltage 12 to 15 VDC type: 0.18 A or less
4 to 20 mA, 0 to 20 mA (Sink type)
0 to 5 VDC, 0 to 10 VDC
Preset input
Note 3)
Current type
Voltage type
Preset input
Analogue
output
Switch
output
Input
impedance
Output signal
(monitor
output)
Linearity
Hysteresis
Repeatability
Sensitivity
Temperature characteristics
Note 4)
Accuracy
Minimum unit
Output pressure
display
Ambient and fluid temperature
1 to 5 VDC (Load impedance: 1 kΩ or more)
4 to 20 mA (Sink type) (Load impedance: 250
Output accuracy within ±6% (Full span)
NPN open collector output: Max. 30 V, 30 mA
PNP open collector output: Max. 30 mA
MPa: 0.01, kgf/cm
250
Approx. 6.5 kΩ
Approx. 2.7
Within ±1% (Full span)
Within 0.5% (Full span)
Within
Within 0.2% (Full span)
Within
±0.12% (Full span)/°C
±3% (Full span)
2
: 0.01, bar: 0.01, PSI: 0.1
0 to 50
°C (No condensation)
Enclosure
ITV10
Note 9)
Weight
Note 1) Please refer to Figure 1 for the relationship between set pressure and input. Because the maximum set pres-
sure differs for each pressure display, refer to Appendix 7.
Additionally, refer to page 18 for the set pressure range by units of standard measured pressure.
Additionally, refer to page 18 as maximum set pressure differs on unit of standard measure.
Note 2) 2-wire type 4 to 20 mA is not available. Power supply voltage (24 VDC or 12 to 15 VDC) is required.
Note 3) Select either analogue output or switch output.
Further, when switch output is selected, select either NPN output or PNP output.
Note
4)
Adjustment of numerical values such as the zero/span adjustment or preset input type is set based on the mi-
nimum units for output pressure display (e.g. 0.01 to 0.50 MPa). Note that the unit cannot be changed.
Note 5) The minimum unit for 0.9 MPa (130 psi) types is 1 psi.
Value for the state with no over current circuit included. If an allowance is provided for an over current circuit,
Note 6)
the input impedance varies depending on the input current. This
mA DC.
Note 7) The above characteristics are confined to the static state. When air is consumed on the output side, the pres-
sure may fluctuate.
Note 8) For communication models, the maximum current consumption is 0.16 A or less.
Note 9) For communication models, add roughly 80 g to the weight (100 g for the PROFIBUS DP).
Note 10) The ITV1000 series is a non-grease model (Wetted parts).
ITV20
ITV30
Approx. 250 g (without options)
Approx. 350 g (without options)
Approx. 645 g (without options)
ITV103
ITV203
ITV303
1.0 MPa
4 points
Ω or less
Note 6)
kΩ
±0.5% (Full span)
IP65
is 350 Ω or less for an input current of 20
ITV105
ITV205
ITV305
Ω or less)
Note 5)
, kPa: 1
Model
Protocol
Note 1)
Version
Communication
speed
Configulation file
Note 2)
I/O occupation area
(input/output data)
Communication data resolution
Fail safe
Note 4)
Terminating
resistance
Note 1) Note that this version information is subject to change.
Note 2) Configulation files can be downloaded from SMC's website: http://www.smc.eu
Note 3) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data.
Note 4) It shows the insulation between electric signal for communication and the ITV supply power.
ITV00-CC
CC-Link
Ver 1.10
156 k/625 k
2.5 M/5 M/10 M bps
—
4 word/4 word, 32 bit/32 bit
(per station, remote device station)
12 bit (4096 resolution)
Note 3)
HOLD
(Switch setting)
/CLEAR
—
ITV00-DN
DeviceNet™
Release2.0
125 k/250 k/500 k bps
EDS
16 bit/16 bit
12 bit (4096 resolution)
HOLD/CLEAR
(Switch setting)
ITV00-PR
PROFIBUS DP
9.6 k/19.2 k/45.45
93.75 k/187.5 k/500
1.5 M/3 M/6 M/12 M bps
12 bit (4096 resolution)
Built into the product
(Switch setting)
DP-V0
GSD
16 bit/16 bit
CLEAR
ITV00-RC
RS-232C
—
k
k
9.6 kbps
—
—
10 bit (1024 resolution)
HOLD
—
10
Combinations
∗ ITV10 models are not applicable.
∗ ITV10 models are not applicable.
Specifications
1
3
5
02
03
04
B
C
N02
N03
N04
F02
F03
F04
Symbol
Applicable model
ITV20
ITV30
Modular Products and Accessory Combinations
Accessory (Option)/Part No.
q Air filter
w Mist separator
e L-bracket
r
Spacer
t Spacer with L-bracket (e + r)
y
Spacer with T-bracket
ITV20
AF30
AFM30
B310L
Y30
Y30L
—
ITV30
AF40
AFM40
B410L
Y40
Y40L
Y40T
Applicable products and accessories
Applicable model
178
SMC REGULATOR
ITV2000
Approx. 133
Approx. 189
Approx. 172
Approx. 243
234
REGULATOR
ITV3000
qAF40wAFM40
qAF30wAFM30
ITV20
ITV30
eL-bracket
rSpacer
Flat bracket
Dimensions
L-bracket
1.6
12
20
60
40
84
40
22
36
52
100
22
4 x ø5.5
8 x ø4.5
4 x ø7
2.3
405
22
40
36
7
36
70
22 14
50
4 x ø5.5
8 x ø4.5
(8.5)
7
4
x
R3.5
15
33
10
50
25
Or
de
r
Made
Made to Order
(Refer to pages 25 and 26 for details.)
Symbol
CE-compliant
Specifications
16 points preset input type
Digital input type
Reverse type
High pressure type
(SUP 1.2 MPa, OUT 1.0 MPa)
Set pressure range 1 to 100 kPa
(Except Series ITV3000)
High speed response type
(Except Series ITV3000)
For manifold mounting
(Except Series ITV3000)
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
X156
X157
X321
X322
X323
X154
X153
Acces-
sories
Standard
specifications
Optional
specifications
Set pressure max. 0.1 MPa
Set pressure max. 0.5 MPa
Set pressure max. 0.9 MPa
Connection Rc 1/4
Connection Rc 3/8
Connection Rc 1/2
Bracket
Bracket
Connection NPT1/4
Connection NPT3/8
Connection NPT1/2
Connection G 1/4
Connection G 3/8
Connection G 1/2
Note 1)
Manifolds are compatible with 2 to 8 stations.
Consult with SMC for 9 stations or more.
Note 2)
Products without symbols are also compatible.
Consult with SMC separately.
Combination
possible
Combination
not possible
Standard
specifications
ITV10ITV20ITV30
L-bracket assembly
(including mounting screws)
Straight type 3
m
Right angle type 3 m
Straight type 3
m
Right angle type 3
m
Straight type 3
m
Right angle type 3
m
Straight type 3 m
Right angle type 3
m
ITV
--Q
ITV
-PR-Q
ITV
-RC-Q
ITV-DN-Q
ITV
-CC-Q
Power cable
connector
Description
KT-ITV-F2
KT-ITV-L2
P398010-12
P398010-13
P398020-500-3
P398020-501-3
P398020-504-3
P398020-505-3
P398020-500-3
P398020-501-3
EX9-ACY00-MJ
Part No.
KT-ITV-F1
KT-ITV-L1
Flat bracket assembly
(including mounting screws)
Bus adapter (CC-Link model only)
Series ITV1000/2000/3000
Supply pressure
q
Air supply solenoid valve
w
Exhaust solenoid valve
rDiaphragmPilot valve
u
Pressure sensor
i
Control circuit
Input signalOutput pressure
When the input signal rises, the air supply solenoid valve qturns ON, and the exhaust solenoid valve wturns OFF. Therefore, supply pressure passes through the air supply solenoid valve qand is applied to the pilot chamber e. The pressure in the pilot chamber eincreases and operates on the upper surface of the diaphragm r.As a result, the air supply valve tlinked to the diaphragm ropens, and a portion of the supply pressure becomes output pressure.This output pressure feeds back to the control circuit ivia the pressure sensor u. Here, a correct operation functions until the output pressure is proportional to the input signal, making possible to obtain output pressure proportional to the input signalalways.
ITV2000, 3000
Pressure display
Power supply
Input signal
qAir supply
solenoid valve
rDiaphragm
yExhaust
valve
tSupply
valve
wExhaust
solenoid valve
Output signal
uPressure
sensor
ePilot
chamber
iControl
circuit
SUPOUT
EXH
EXH
ITV1000
SUP
EXH
OUT
EXH
tSupply valve
wExhaust
solenoid valve
uPressure sensor
qAir supply
solenoid valve
Input signal
Power supplyOutput signal
rDiaphragm
ePilot chamber
Pressure display
iControl
circuit
Working Principle Diagram
Block diagram
Working Principles
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
11
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Working Principles
When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF. Therefore,
supply pressure passes through the air supply solenoid valve q and is applied to the pilot chamber e. The pressure in the pilot
chamber e increases and operates on the upper surface of the diaphragm r.
As a result, the air supply valve t linked to the diaphragm r opens, and a portion of the supply pressure becomes output
pressure.
This output pressure feeds back to the control circuit i via the pressure sensor u. Here, a correct operation functions until the
output pressure is proportional to the input signal, making possible to obtain output pressure proportional to the input signal
always.
Working Principle Diagram
Pressure display
Pressure display
Power supplyOutput signal
Input signal
q Air supply
solenoid
valve
r Diaphragm
SUP
i Control
circuit
ITV1000
w Exhaust
solenoid
valve
EXH
u Pressure sensor
e Pilot chamber
t Supply valve
OUT
EXH
Power supply
Input signal
q Air supply
solenoid
valve
r Diaphragm
y Exhaust
valve
t Supply
valve
SUPOUT
i Control
circuit
ITV2000, 3000
Output signal
w Exhaust
solenoid
valve
EXH
u Pressure
sensor
e Pilot
chamber
EXH
Block diagram
Supply pressure
Air supply solenoid valve
q
Input signalOutput pressure
i
Control circuit
w
Exhaust solenoid valve
u
Pressure sensor
r DiaphragmPilot valve
12
Series ITV101
Series
ITV201
Pressure characteristics
Flow characteristics
LinearityHysteresis
0255075
0.01
0.00
0.03
0.02
0.04
0.08
0.07
0.06
0.05
0.09
0.10
100
025507
5
–
1.0
–
0.5
0.0
0.5
1.0
100
0.00.10.2
–
0.5
0.3
0.0
0.5
1.0
–
1.0
0200400600
0.05
0.10
0.15
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPaSet pressure: 0.05 MPa
Relief flow characteristics
Repeatability
02648
–
1.0
–
0.5
0.0
0.5
1.0
10
0200400800
0.05
600
0.10
0.15
0.25
0.20
0.00
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Pressure characteristics
Linearity
Hysteresis
0255075100
025507
5
–
1.0
–
0.5
0.0
0.5
1.0
100
0.00.10.2
–
0.5
0.3
0.0
0.5
1.0
–
1.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure: 0.05 MPa
Relief flow characteristics
Repeatability
02648
–
1.0
–
0.5
0.0
0.5
1.0
10
020408
0
0.05
60
0.10
0.15
0.25
0.20
0.00
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Set point
Out
Return
Flow characteristics
020406080100
0.05
0.10
0.15
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
0.10
0.08
0.06
0.04
0.02
0.00
0.01
0.03
0.07
0.05
0.09
0.11
Set point
Out
Return
Series ITV1000/2000/3000
Series ITV301
Pressure characteristics
Flow characteristics
Linearity
Hysteresis
0255075
0.00
0.05
0.04
0.03
0.02
0.01
0.07
0.06
0.09
0.08
0.10
100
0255075
–
1.0
–
0.5
0.0
0.5
1.0
100
0.00.10.2
–
0.5
0.3
0.0
0.5
1.0
–
1.00500100015002000
0.05
0.10
0.15
0.00
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Set pressure: 0.05 MPa
Relief flow characteristics
Repeatability
02648
–
1.0
–
0.5
0.0
0.5
1.0
10
0500100020001500
0.10
0.05
0.15
0.25
0.20
0.00
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Out
Return
Set point
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
13
Series ITV301
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Linearity
0.10
0.09
0.08
0.07
0.06
0.05
0.04
0.03
Set pressure (MPa)
0.02
0.01
0.00
0255075
Pressure characteristics
1.0
0.5
0.0
–
0.5
Output deviation factor (%F.S.)
–
1.0
0.00.10.2
Input signal (%F.S.)
Set pressure: 0.05 MPa
Supply pressure (MPa)
100
Set point
0.3
Hysteresis
1.0
0.5
Out
0.0
–
0.5
Output deviation factor (%F.S.)
–
1.0
0255075
Input signal (%F.S.)
Flow characteristics
0.15
0.10
0.05
Set pressure (MPa)
0.00
0500100015002000
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Return
100
Repeatability
1.0
0.5
0.0
–
0.5
Output deviation factor (%F.S.)
–
1.0
02648
Relief flow characteristics
0.25
0.20
0.15
0.10
Set pressure (MPa)
0.05
0.00
0500100020001500
Repetition
Supply pressure: 0.2 MPa
Flow rate (l/min (ANR))
10
14
Series
ITV203
Pressure characteristics
Flow characteristics
Linearity
Hysteresis
0255075
0.0
0.1
0.2
0.4
0.3
0.6
0.5
1000255075
–
1.0
–
0.5
0.
0
0.
5
1.0
100
0.20.40.6
–
0.5
0.8
0.0
0.5
1.0
–
1.0
0500100015002000
0.4
0.3
0.2
0.1
0.5
0.6
0.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Set pressure: 0.2 MPa
Relief flow characteristics
Repeatability
02648
–
1.0
–
0.5
0.0
0.5
1.0
10
050010002000
0.3
0.2
0.1
1500
0.5
0.4
0.6
0.7
0.8
0.0
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Series ITV103
Linearity
Pressure characteristics
0.20.40.6
–
0.5
0.8
0.0
0.5
1.0
–
1.0
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure: 0.2 MPa
Flow characteristics
050100150200250
0.2
0.1
0.0
0.4
0.3
0.6
0.5
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
0255075100
Set pressure (MPa)
Input signal (%F.S.)
0.5
0.6
0.4
0.3
0.2
0.1
0.0
Hysteresis
0255075
–
1.0
–
0.5
0.0
0.5
1.0
100
Output deviation factor (%F.S.)
Input signal (%F.S.)
Repeatability
02648
–
1.0
–
0.5
0.0
0.5
1.0
10
Output deviation factor (%F.S.)
Repetition
Relief flow characteristics
050100200150
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Set point
Set point
Out
Return
Out
Return
Series ITV1000/2000/3000
Series ITV303
Pressure characteristics
Flow characteristics
Linearity
Hysteresis
0255075
0.1
0.0
0.2
0.4
0.3
0.6
0.5
1000255075
–
1.0
–
0.5
0.0
0.5
1.0
100
0.20.40.6
–
0.5
0.8
0.0
0.5
1.0
–
1.00100020003000400050006000
0.2
0.1
0.4
0.3
0.6
0.5
0.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Set pressure: 0.2 MPa
Relief flow characteristics
Repeatability
02648
–
1.0
–
0.5
0.0
0.5
1.0
10
0100020003000
0.1
50004000
0.3
0.2
0.5
0.4
0.6
0.8
0.7
0.0
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Set point
Out
Retirm
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
15
Series ITV303
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Linearity
0.6
0.5
0.4
0.3
0.2
Set pressure (MPa)
0.1
0.0
0255075
Input signal (%F.S.)
Pressure characteristics
1.0
0.5
0.0
–
0.5
Output deviation factor (%F.S.)
–
1.0
0.20.40.6
Supply pressure (MPa)
Set pressure: 0.2 MPa
Hysteresis
1.0
0.5
Out
0.0
Retirm
–
0.5
Output deviation factor (%F.S.)
–
1000255075
1.0
Input signal (%F.S.)
Flow characteristics
0.6
0.5
Set point
0.8
0.4
0.3
0.2
Set pressure (MPa)
0.1
0.0
010002000300040005000 6000
Flow rate (l/min (ANR))
100
Supply pressure: 0.7 MPa
Repeatability
1.0
0.5
0.0
–
0.5
Output deviation factor (%F.S.)
–
1.0
02648
Repetition
Relief flow characteristics
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Set pressure (MPa)
0.1
0.0
0100020003000
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
10
50004000
16
Series ITV105
Series ITV205
Pressure characteristics
LinearityHysteresis
0255075
0.1
0.0
0.3
0.2
0.4
0.7
0.6
0.5
0.8
1.0
0.9
100
0255075
–
1.0
–
0.5
0.0
0.5
1.0
100
0.40.60.8
–
0.5
1.01.2
0.0
0.5
1.0
–
1.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure: 0.4 MPa
Relief flow characteristics
Repeatability
02648
–
0.5
–
0.25
0
0.25
0.5
10
0
50010002000 2500
0.2
0.1
1500
0.5
0.4
0.3
0.7
0.6
1.0
0.9
0.8
0.0
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Flow characteristics
0
500100015002000 2500
0.5
0.4
0.3
0.2
0.1
0.7
0.6
1.0
0.9
0.8
0.0
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Pressure characteristics
0.40.60.811.2
–
0.5
0.0
0.5
1.0
–
1.0
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure: 0.4 MPa
Flow characteristics
050100 150 200 250 300 350
0.2
0.1
0.0
0.4
0.3
0.6
0.7
0.8
0.9
1.0
0.5
Supply pressure: 1.0 MPa
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Linearity
0255075100
Set pressure (MPa)
Input signal (%F.S.)
0.6
0.7
0.8
0.9
1.0
0.5
0.4
0.3
0.2
0.1
0.0
Hysteresis
0255075
–
1.0
–
0.5
0.0
0.5
1.0
100
Output deviation factor (%F.S.)
Input signal (%F.S.)
Repeatability
02648
–
1.0
–
0.5
0.0
0.5
1.0
10
Output deviation factor (%F.S.)
Repetition
Relief flow characteristics
050100150200250 300
0.8
0.9
1.0
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Set point
Set point
Out
Return
Out
Return
Series ITV1000/2000/3000
Series ITV305
Pressure characteristics
Flow characteristics
Linearity
Hysteresis
0255075
0.0
0.3
0.2
0.1
0.4
0.7
0.6
0.5
1.0
0.9
0.8
1000255075
–
1.0
–
0.5
0.0
0.5
1.0
100
0.40.6
–
0.5
0.81.01.2
0.0
0.5
1.0
–
1.00
1000200030004000500060007000
0.4
0.3
0.2
0.1
0.7
0.6
0.5
1.0
0.9
0.8
0.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Set pressure: 0.4 MPa
Relief flow characteristics
Repeatability
02648
–
1.0
–
0.5
0.0
0.5
1.0
10
0
1000200050006000
0.3
0.2
0.1
30004000
0.5
0.4
0.7
0.6
1.0
0.9
0.8
0.0
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Set point
Out
Return
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
17
Series ITV305
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Linearity
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Set pressure (MPa)
0.1
0.0
0255075
Input signal (%F.S.)
Pressure characteristics
1.0
0.5
0.0
–
0.5
Output deviation factor (%F.S.)
–
1.0
0.40.6
Supply pressure (MPa)
Set pressure: 0.4 MPa
Set point
0.81.01.2
Hysteresis
1.0
0.5
0.0
–
0.5
Output deviation factor (%F.S.)
–
1000255075
1.0
Flow characteristics
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
Set pressure (MPa)
0.2
0.1
0.0
0
10002000300040005000 6000 7000
Out
Return
Input signal (%F.S.)
Supply pressure: 1.0 MPa
Flow rate (l/min (ANR))
100
Repeatability
1.0
0.5
0.0
–
0.5
Output deviation factor (%F.S.)
–
1.0
02648
Repetition
Relief flow characteristics
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
Set pressure (MPa)
0.2
0.1
0.0
0
100020005000 6000
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
30004000
10
18
ITV10
Flat bracket
L-bracket
Note) Do not attempt to rotate, as the cable connector does not turn.
Dimensions
100
84
52
40
50
Mounting hole
4 x ø7
Setting part
Cable connector (4 wire)
Right angle type
(33)
Cable connector (4 wire)
Straight type
(Option)
KT-ITV-F1
Flat bracket
19.5
11
SUP port, OUT port
2 x Rc1/8, 1/4
Exhaust port
Rc 1/8
Solenoid valve EXH
EXH (3)
12.5
Cable connection
threads
M12 x 1
40
Mounting hole
4 x M4 x 0.7 thread
depth 6 mm through
SUP (1)
M3 x 0.5
Solenoid valve
EXH
Rc 1/8
Pressure gauge
connection port
(11)71
12
OUT (2)
(Option)
KT-ITV-L1
L-bracket
(Option)
KT-ITV-F1
Flat bracket
45
22
2.3
SUP port, OUT port
2
x
Rc1/8, 1/4
(8.5)
7
R3.5
15
33
10
50
25
(Option)
KT-ITV-L1
L-bracket
Series ITV1000/2000/3000
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
CC-Link/ITV100-CCDeviceNet™/ITV100-DN
PROFIBUS DP/
ITV100-PR
RS-232C/
ITV100-RC
With power cable connector ∗
ITV100-
common dimensions
CCDNPRRC
∗Dimensions not shown are as on P.19.
Note) Communication cable (other than RS-232C) should be obtained separately. (See P.9.)
∗Dimensions not shown are as on P.19.
∗Dimensions not shown are as on P.19.
Note) Do not attempt to rotate, as the cable connector does not turn.
∗Dimensions not shown are as on P.19.
(53)
(11)10812
40
M12x 1Power cabl
e
connection thread
Rc 1/8Pressure gauge connection port
M3x 0.5
Solenoid valve
EXH
SUP (1)OUT (2)
M12x 1Communication cable
connection thread
BUS adapter
1010
M12x 1Reverse connector
M12x 1
8.5
19.5
11
EXH (3)
Solenoidvalve
EXH
Rc 1/8Exhaust
port
2x Rc 1/8, 1/4SUP port, OUT port
(11)9812
1010
40
M12
x 1
Power cableconnection thread
Rc 1/8Pressure gauge connection port
M3x 0.5
Solenoid valve
EXH
SUP (1)OUT (2)
M12x 1Communication cable
connection thread
10.511.5
(11)
(16)
10812
40
M12x 1Power cable
connection thread
Rc 1/8Pressure gauge connection port
M3x 0.5
Solenoid valve
EXH
SUP (1)OUT (2)
M12 reverse connectorCommunication cable
connection thread
19.5
11
Rc 1/8Exhaust
port
2x Rc 1/8, 1/4SUP port, OUT port
EXH (3)
Solenoidvalve
EXH
9.5
(11)12
1010
40
M12
x 1
Power cableconnection thread
Rc 1/8Pressure gauge connection port
M3x 0.5
Solenoid valve
EXH
SUP (1)OUT (2)
M12x 1Communication cable connection thread
98
19.5
11
8.5
Rc 1/8Exhaust
port
2x Rc 1/8, 1/4SUP port, OUT port
EXH (3)
Solenoidvalve
EXH
19.5
11
8.5
Rc 1/8Exhaust
port
2x Rc 1/8, 1/4SUP port, OUT port
EXH (3)
Solenoidvalve
EXH
Cable connector (4 wire)
Straight type
Cable connector (4 wire)
Right angle type
(33)
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
19
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
CC-Link/ITV100-CCDeviceNet™/ITV100-DN
M12 x 1
Reverse connector
BUS adapter
M12 x 1
8.5
M12 x 1
Communication cable
connection thread
10 10
(53)
M12 x 1
Power cabl
connection thread
e
(11)10812
8.5
M12 x 1
Communication cable
connection thread
x 1
M12
Power cable
connection thread
10 10
(11)9812
M3 x 0.5
Solenoid
valve
EXH
19.5
11
2 x Rc 1/8, 1/4
SUP port, OUT port
∗ Dimensions not shown are as on P.19.
PROFIBUS DP/
9.5
Solenoid
valve
EXH
19.5
11
Solenoid valve
EXH
Rc 1/8
Exhaust
port
EXH (3)
ITV100-PR
M3 x 0.5
Solenoid valve
EXH
Rc 1/8
Exhaust
port
EXH (3)
SUP (1)OUT (2)
40
Rc 1/8
Pressure gauge connection port
M12 reverse connector
Communication cable
connection thread
10.511.5
(16)
SUP (1)OUT (2)
M12 x 1
Power cable
connection thread
(11)
10812
M3 x 0.5
Solenoid valve
Rc 1/8
Exhaust
port
EXH (3)
Rc 1/8
Exhaust
port
EXH (3)
EXH
Solenoid
valve
EXH
19.5
11
2 x Rc 1/8, 1/4
SUP port, OUT port
∗ Dimensions not shown are as on P.19.
RS-232C/
Solenoid
valve
EXH
19.5
11
ITV100-RC
8.5
SUP (1)OUT (2)
40
Rc 1/8
Pressure gauge connection port
M12 x 1
Communication cable connection thread
M3 x 0.5
Solenoid valve
EXH
M12
x 1
Power cable
connection thread
10 10
SUP (1)OUT (2)
(11)12
98
2 x Rc 1/8, 1/4
SUP port, OUT port
∗ Dimensions not shown are as on P.19.
Rc 1/8
Pressure gauge connection port
With power cable connector ∗
Note) Communication cable (other than RS-232C)
should be obtained separately. (See P.9.)
40
ITV100-
(33)
2 x Rc 1/8, 1/4
SUP port, OUT port
∗ Dimensions not shown are as on P.19.
CC
DN
common dimensions
PR
RC
Cable connector (4 wire)
Right angle type
Note) Do not attempt to rotate, as the cable connector does not turn.
40
Rc 1/8
Pressure gauge connection port
Cable connector (4 wire)
Straight type
20
50
40
52
84
100
Flat bracket
KT-ITV-F2
(Option)
Flat bracket
KT-ITV-F2
(Option)
36
(11)
SUP (1)
12
OUT (2)
93
12.5
19
13.5
EXH (3)
4 x ø7
Mounting hole
M5 x 0.8
Solenoid valve
EXH
Solenoid valve
EXH
4 x M5 x 0.8 thread
depth 6 mm through
Mounting hole
SUP port, OUT port
2 x Rc 1/4, 3/8
Exhaust port
Rc 1/4
L-bracket
M12 x 1
Cable connection thread
45
2.3
36
L-bracket
KT-ITV-L2
(Option)
19
(33)
Cable connector (4 wire)
Straight type
Cable connector (4 wire)
Right angle type
Note) Do not attempt to rotate, as the cable connector does not turn.
2 x Rc 1/4, 3/8
SUP port, OUT port
(8.5)
7
R3.5
15
33
10
50
25
L-bracket
KT-ITV-L2
(Option)
Series ITV1000/2000/3000
ITV20
Flat bracket
Dimensions
1913.5
8.5
Rc1/4Exhaust
port
2 x Rc 1/4,3/8SUP port, OUT port
EXH(3)
Solenoidvalve
EXH
(11)120
36
12
1010
M12 x 1Power cabl
e
connection thread
M5 x 0.8
Solenoid valve
EXH
SUP(1)
OUT(2)
M12 x 1Communication cable
connection thread
1913.5
Rc1/4Exhaust
port
2 x Rc 1/4,3/8SUP port, OUT port
EXH(3)
Solenoidvalve
EXH
9.5
(11)
(16)
(53)
13012
36
10.511.5
M12 x 1Power cabl
e
connection thread
M5 x 0.8
Solenoid valve
EXH
SUP(1)OUT(2)
(11)13012
36
1010
M5 x 0.8
Solenoid valve
EXH
SUP(1)
OUT(2)
1913.5
8.5
EXH(3)
Solenoidvalve
EXH
Rc1/4Exhaust
port
2 x Rc 1/4,3/8SUP port, OUT port
(11)120
36
1010
M12 x 1Power cabl
e
connection thread
M5 x 0.8
Solenoid valve
EXH
SUP(1)OUT(2)
M12 x 1Communication cable
connection thread
12
1913.5
8.5
Rc1/4Exhaust
port
2 x Rc 1/4,3/8SUP port, OUT port
EXH(3)
Solenoidvalve
EXH
M12 x 1
BUS adapter
M12x 1Communication cable
connection thread
M12x 1Reverse connector
M12x 1Power cabl
e
connection thread
M12 reverse connectorCommunication cable
connection thread
CC-Link/ITV200-CCDeviceNet™/ITV200-DN
PROFIBUS DP/ITV200-PRRS-232C/ITV200-RC
With power cable connector ∗
ITV200-
common dimensions
CCDNPRRC
Note) Communication cable (other than RS-232C) should be obtained separately. (See P.9.)
∗Dimensions not shown are as on P.21.
∗Dimensions not shown are as on P.21.
∗Dimensions not shown are as on P.21.
∗Dimensions not shown are as on P.21.
Note) Do not attempt to rotate, as the cable connector does not turn.
Cable connector (4 wire)
Straight type
(33)
Cable connector (4 wire)
Right angle type
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
21
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
CC-Link/ITV200-CCDeviceNet™/ITV200-DN
M12 x 1
Reverse connector
BUS adapter
8.5
Solenoid
valve
EXH
1913.5
2 x Rc 1/4,3/8
SUP port, OUT port
∗ Dimensions not shown are as on P.21.
M12 x 1
M5 x 0.8
Solenoid valve
EXH
Rc1/4
Exhaust
port
EXH(3)
M12 x 1
Communication cable
connection thread
10 10
(53)
SUP(1)
M12 x 1
Power cabl
connection thread
36
OUT(2)
e
(11)13012
Solenoid
valve
EXH
∗ Dimensions not shown are as on P.21.
8.5
1913.5
2 x Rc 1/4,3/8
SUP port, OUT port
M5 x 0.8
Solenoid valve
EXH
Rc1/4
Exhaust
port
EXH(3)
PROFIBUS DP/ITV200-PRRS-232C/ITV200-RC
9.5
M12 reverse connector
Communication cable
connection thread
10.511.5
(16)
M12 x 1
Power cabl
connection thread
e
(11)
8.5
M12 x 1
Communication cable
connection thread
10 10
SUP(1)OUT(2)
36
M12 x 1
Communication cable
connection thread
10 10
M12 x 1
Power cabl
connection thread
M12 x 1
Power cabl
connection thread
e
(11)120
12
e
(11)120
M5 x 0.8
Solenoid valve
EXH
Rc1/4
Exhaust
port
Solenoid
valve
1913.5
EXH
2 x Rc 1/4,3/8
SUP port, OUT port
∗ Dimensions not shown are as on P.21.
SUP(1)OUT(2)
EXH(3)
With power cable connector ∗
Note) Communication cable (other than RS-232C)
should be obtained separately. (See P.9.)
36
ITV200-
(33)
13012
Solenoid
valve
EXH
∗ Dimensions not shown are as on P.21.
CC
DN
common dimensions
PR
RC
Cable connector (4 wire)
Right angle type
1913.5
2 x Rc 1/4,3/8
SUP port, OUT port
Cable connector (4 wire)
Straight type
M5 x 0.8
Solenoid valve
EXH
Rc1/4
Exhaust
port
EXH(3)
SUP(1)
OUT(2)
36
12
Note) Do not attempt to rotate, as the cable connector does not turn.
22
30
50
66
40
52
84
100
36
Flat bracket
KT-ITV-F2
(Option)
Flat bracket
KT-ITV-F2
(Option)
(11)
12
114
SUP (1)
OUT (2)
Rc 1/4
Solenoid valve
EXH
12.5
25
228
35.7
EXH (3)
Mounting hole
4 x ø7
Cable connector (4 wire)
Right angle type
Cable connection thread
M12
x 1
Rc 1/2
Exhaust port
4 x M5 x 0.8 thread
depth 6 mm through
Mounting hole
2 x Rc 1/4, 3/8, 1/2
SUP port, OUT port
Cable connector (4 wire)
Straight type
Note) Do not attempt to rotate, as the cable connector does not turn.
Note) Do not attempt to rotate, as the cable connector does not turn.
CC-Link/ITV30-CCDeviceNet™/ITV30-DN
Cable connector (4 wire)
Straight type
Cable connector (4 wire)
Right angle type
(33)
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
23
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
CC-Link/ITV30-CCDeviceNet™/ITV30-DN
M12 x 1
Reverse connector
BUS adapter
M12 x 1
8.5
M12 x 1
Communication cable connection thread
10
10
M12 x 1
Power cabl
connection thread
e
(11)151
M12 x 1
Communication cable
connection thread
8.5
M12 x 1
Power cable
connection thread
10 10
(11)141
Solenoid
valve
EXH
Rc 1/2
35.7
8
22
2 x Rc 1/4, 3/8, 1/2
SUP port, OUT port
∗ Dimensions not shown are as on P.23.
PROFIBUS DP/
9.5
Solenoid
valve
EXH
35.7
22 8
Exhaust
port
EXH (3)
ITV30-PR
Rc 1/2
Exhaust
port
EXH (3)
SUP (1)
36
Rc 1/4
Pressure gauge
connection port
M12 reverse connector
Communication cable connection thread
SUP (1)
10.511.5
(16)(53)
OUT (2)
4 x M5 x 0.8 thread
depth 6 mm through
Mounting hole
M12 x
Power cable
connection thread
OUT (2)
12
1
(11)
151
Solenoid
valve
EXH
Rc 1/2
35.7
22 8
2 x Rc 1/4, 3/8, 1/2
SUP port, OUT port
∗ Dimensions not shown are as on P.23.
RS-232C/
Solenoid
valve
EXH
35.7
22 8
ITV30-RC
M12 x 1
Communication cable
connection thread
8.5
Exhaust
port
EXH (3)
Rc 1/2
Exhaust
port
EXH (3)
SUP (1)OUT (2)
36
Rc 1/4
Pressure gauge
connection port
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
M12 x 1
Power cable connection
thread
10 10
SUP (1)OUT (2)
12
(11)141
2 x Rc 1/4, 3/8, 1/2
SUP port, OUT port
∗ Dimensions not shown are as on P.23.
With power cable connector
CC
∗ITV30-
DN
PR
RC
common dimensions
36
Rc 1/4
Pressure gauge
connection port
(33)
12
4 x M5 x 0.8 thread
depth 6 mm through
Mounting hole
Cable connector (4 wire)
Right angle type
36
2 x Rc 1/4, 3/8, 1/2
SUP port, OUT port
∗ Dimensions not shown are as on P.23.
Cable connector (4 wire)
Straight type
Note) Do not attempt to rotate, as the cable connector does not turn.
Rc 1/4
Pressure gauge
connection port
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
12
24
Parallel input type with digital 10 bit.
Digital Input Type
2
ITV20
X157
ITV30
4
ITV10
X1574
4
0
0
S
N
S
N
S
N
0X157
0
0
0
Able to control 16-point-pressure by 4 bit switching input
16 Points Preset Input Type
1
ITV20
16 points preset type
X156
ITV30
4
ITV10X156
4
2
3
2
3
2
3
4
0
0
0
X156
In compliance with the input, inverse proportional pressure is displayed.
Reverse Type
3
ITV20X321
ITV10X321
ITV30X321
High Pressure Type (SUP 1.2 MPa, OUT 1.0 MPa)
4
ITV20X322
ITV10X322
ITV30X322
0
0100
Output pressure
(MPa)
This range is
outside of the
control (output).
0.005 MPa
Rated
pressure
5
5
5
Set Pressure Range 1 to 100 kPa
5
ITV20X323
ITV10X323
1
1
0
0
0
Digital input type
Note 1) in part number is the same model no. for the standard products.
Note 2) Right angle type cable connectors cannot be selected.
Note 1)
in part number is the same model no. for the standard products.
Note 2) Except for preset input type.
Input/output characteristics chart
Input signal (%F.S.)
Reverse type
High pressure type (SUP 1.2 MPa, OUT 1.0 MPa)
Set pressure range 1 to 100 kPa
Made to Order Specifications 1
Series ITV1000/2000/3000
Contact SMC regarding detailed dimensions, specifications and delivery times.
Note 1) in part number is the same model no. for
the standard products.
Note 2) Monitor output is switch output type only.This
cannot be selected for types without a moni
-
tor output or with analogue output.
Note 3) Values can be adjusted starting from the mini-
mum output pressure display units.
MPa
0.01
kgf/cm
2
0.01
bar
0.01
psi
0.1
kPa
1
∗ 130 psi type: 1 psi
Made to
Orde
r
2 through 8 station manifold.
How to Order Manifolds
IITV20025
Manifold Specifications
(Except Series ITV3000)
7
How to Order Manifold Assemblies
Example
1
2
3
Stations
Pressure response with no load is approx. 0.1 sec.
High-Speed Response Time Type
6
ITVX1542010S012
Pressure display unit
—
2345
MPa
kgf/cm
2
barpsi
kPa
∗
∗
Model
12
1000 type2000 type
Pressure range
135
0.1 MPa
0.5 MPa
0.9 MPa
Power supply
voltage
01
24 VDC
12 to 15 VDC
Input signal
0123
Current 4 to 20 mA (Sink type)Current 0 to 20 mA (Sink type)
Voltage 0 to 5 VDC
Voltage 0 to 10 VDC
1
Analogue output 1 to 5 VDC
Monitor output
Thread type
—
N
TF
Rc
NPT
NPTF
G
Port size
123
1/8 (1000 type)
1/4 (1000, 2000 type)
3/8 (2000 type)
Bracket
—
BC
Without bracket
Flat bracket
L-bracket
Cable connector type
SL
N
Straight type 3 m
Right angle type 3
m
Without cable connector
ITV1000, 2000
0203
OUT port size
Connection thread type
1/43/8
—
NF
PT
NPT
PF
2
8
Valve stations
2 stations
8 stations
Note) Refer to the table below for possible mixed combination.
Model
ITV101
ITV103
ITV105
ITV201
ITV203
ITV205
ITV101ITV103ITV105ITV201ITV203ITV205
IITV20-02-3 ……………………
∗
ITV1030-311S-X26 …………
∗P398020-13 …………………∗ITV2050-212S-X26 …………
1 set (3 station manifold base part no.) 1 set (Electro-pneumatic regulator part no.)
Note 2)
1 set (Blanking plate assembly part no.) 1 set (Electro-pneumatic regulator part no.)
Note 2)
The ∗is the symbol for mounting. Add the ∗symbol at the beginning of part numbers for electro-pneumatic regulators, etc. to be mounted on the base.
Note1)Electro-pneumatic regulators are counted starting from station 1 on
the left side with the OUT ports in front.
Note
2)
The port size for mounted electro-pneumatic regulators is Rc 1/8 (ITV1000), Rc 1/4 (ITV2000) only.
Note 3) When there
is a large number of stations, use piping with the largest
possible inside diameter for the supply side, such as steel piping.
Note
4)
The use of the straight type cable connector is recommended. To mountrightangle
type,becertaintocheckthatnopossible
interference occurs.
Note
5)
Whenmountingablankingplateandtheregulatorwithdifferentpressure set, please inform SMC of the order of a manifold station beside a purchase order.
ITV1030-311S-X26
Electro-pneumatic regulator
P398020-13
Blanking plate assembly
ITV2050-212S-X26
Electro-pneumatic regulator
IITV20-02-3
Manifold base (3 stations)
Note 1)
∗Only for overseas sales (SI units are to be used inside Japan).
High-speedresponse timespecifications
Made to Order Specifications 2
Series ITV1000/2000/3000
Contact SMC regarding detailed dimensions, specifications and delivery times.
Made to
Order
25
Series ITV1000/2000/3000
Made to Order Specifications 2
Contact SMC regarding detailed dimensions, specifications and delivery times.
6
High-Speed Response Time Type
Pressure response with no load is approx. 0.1 sec.
ITVX1542 0 10S0 12
Made to
Order
Model
1
2
1000 type
2000 type
Pressure range
Power supply
voltage
24 VDC
0
12 to 15 VDC
1
0
1
2
3
7
Manifold Specifications
2 through 8 station manifold.
How to Order Manifolds
0.1 MPa
1
0.5 MPa
3
0.9 MPa
5
Input signal
Current 4 to 20 mA (Sink type)
Current 0 to 20 mA (Sink type)
Voltage 0 to 5 VDC
Voltage 0 to 10 VDC
Monitor output
Analogue output 1 to 5 VDC
1
Thread type
—
N
T
F
Rc
NPT
NPTF
G
(Except Series ITV3000)
Port size
1
2
3
Pressure display unit
—
2
3
4
5
∗ Only for overseas sales
(SI units are to be used inside Japan).
MPa
kgf/cm
bar
psi
kPa
2
∗
∗
Cable connector type
S
L
N
Straight type 3 m
Right angle type 3 m
Without cable connector
Bracket
—
Without bracket
1/8 (1000 type)
1/4 (1000, 2000 type)
B
C
Flat bracket
L-bracket
3/8 (2000 type)
How to Order Manifold Assemblies
High-speed
response time
specifications
IITV20025
Valve stations
2
8
ITV1000, 2000
IITV20-02-3 ……………………
∗
ITV1030-311S-X26 …………
∗P398020-13 …………………
∗ITV2050-212S-X26 …………
The ∗ is the symbol for mounting. Add the ∗ symbol at the
beginning of part numbers for electro-pneumatic regulators, etc. to
be mounted on the base.
Note) Refer to the table below for possible mixed combination.
Model
ITV101
ITV103
ITV105
ITV201
ITV203
ITV205
ITV101ITV103ITV105ITV201ITV203ITV205
1 set (3 station manifold base part no.)
1 set (Electro-pneumatic regulator part no.)
1 set (Blanking plate assembly part no.)
1 set (Electro-pneumatic regulator part no.)
OUT port size
02
03
1/4
3/8
Connection thread type
—
PT
N
NPT
F
PF
2 stations
8 stations
Note 2)
Note 2)
Example
Electro-pneumatic regulator
ITV1030-311S-X26
Manifold base
(3 stations)
IITV20-02-3
Note 1) Electro-pneumatic regulators are counted starting from station 1 on
the left side with the OUT ports in front.
2)
The port size for mounted electro-pneumatic regulators is Rc 1/8
Note
(ITV1000), Rc 1/4 (ITV2000) only.
Note 3) When there
possible inside diameter for the supply side, such as steel piping.
4)
The use of the straight type cable connector is recommended. To
Note
mount right angle
interference occurs.
5)
When mounting a blanking plate and the regulator with different
Note
pressure set, please inform SMC of the order of a manifold station
beside a purchase order.
1
is a large number of stations, use piping with the largest
Blanking plate assembly
P398020-13
Electro-pneumatic regulator
ITV2050-212S-X26
2
3
Stations
type, be certain to check that no possible
Note 1)
26
Safety Instructions
Limited warranty and Disclaimer/Compliance Requirements
The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”.
Read and accept them before using the product.
1. The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract
if necessary.
If anything is unclear, contact your nearest sales branch.
Caution
Limited warranty and Disclaimer
1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.
Note 2)
Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest
sales branch.
2.
For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product
or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure
of the product.
3.
Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified
catalogue for the particular products.
Note 2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of
rubber material are not covered by the limited warranty.
Compliance Requirements
1.
The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or
any other weapon is strictly prohibited.
2.
The exports of SMC products or technology from one country to another are governed by the relevant security laws
and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another
country, assure that all local rules governing that export are known and followed.
Back page 2
Air Supply
Caution
Handling
Caution
Connect the cable to the connector on the body with
the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage.
Further, use DC power with sufficient capacity and a low ripple.
Caution
Specific Product Precautions 1
Series ITV0000/1000/2000/3000
Wiring
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions,
“Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
A right angle type cable is also
available. The entry direction
for the right angle type con
nector is to downwards (SUP
port side).
Never turn the connector as it
is not designed to turn. Using
force to turn the connector will
damage the connector cou
pling.
3: (Blue)
1: (Brown)
2: (White)
4: (Black)
Wiring Diagrams
Current signal type
Analogue output, voltage type
Vs
A
Voltage signal type
Monitor output voltage
Vs
Vin
Vs: Power Supply 24 V DC ±10%
12 to 15 V DC
A : Input signals 4 to 20 mA DC
0 to 20 mA DC
Vs : Power Supply 24 V DC ±10%
12 to 15 V DC
Vin: Input signals 0 to 5 V DC
0 to 10 V DC
1
Brown
Power
2
White
Signal
3
Blue
COM
4
Black
Monitor
Terminal No.
Lead wire colour
Wiring
Monitor output wiring diagram
Body
Note)
Brown
Blue
White
Black
Series ITV0000/009 Precautions
1. Do not use a lubricator on the supply side of this product, as
this can cause malfunction. When lubrication of the terminal
equipment is necessary, connect a lubricator on the output
side of this equipment.
2. If electric power is shut off while pressure is being applied,
pressure will be retained on the output side.
However, this output pressure is held only temporarily and is not guaranteed.
If exhausting of this pressure is desired, shut off the power
after reducing the set pressure, and discharge the air using a residual
pressure exhaust valve, etc.
3. If power to this product is cut off due to a power failure, etc.
when
it is in a controlled state, output pressure will be retained temporarily. Handle carefully when operating with output
pressure released to the atmosphere, as air will continue to
flow out
.
4. If supply pressure to this product is interrupted while the power
is
still on, the internal solenoid valve will continue to operate
and a humming noise may be generated.
Since the life of the product may be shortened, shut off the power
supply also when supply pressure is shut off.
5. This product is adjusted for each specification at the time of
shipment from
the factory. Avoid careless disassembly or remo-
val of parts, as this can lead to malfunction.
6. The optional cable connector is a 4 wire type. When the monitor output (analogue output or switch output) is not being
used, keep it from touching the other wires as this can cause
malfunction.
7. Please note that the right angle cable does not rotate and is limited to only one entry direction.
8. Take the following steps to avoid malfunction due to noise.
1) Remove power supply noise during operation by installing a line fil-
ter, etc. in the AC power line.
2) For avoiding the influence of noise or static electricity, install this
product and its wiring as far as possible from strong electric fields
such as those of motors and power lines, etc.
3) Be sure to implement protective measures against load surge for in
-
duction loads (solenoid valves, relays, etc.).
9. The product characteristics are confined to the static state.
The pressure may not reach the set pressure and the life of
the product may extremely be shortened with buzzing of the
solenoid valve when air is consumed on the output side, especially when it is used with a system which has a large
amount of leakage.
10.
For details on the handling of this product, refer to the
instruction manual which is included with the product
.
11. In locations where the body is exposed to water, dust,
etc., there is a possibility that moisture or dust could
enter the body through the breathing hole.
Mount a fitting and tube (M-3AU-3 fitting and
TIU01m-mm tube recommended) onto the breathing hole and run the tube to a location not exposed to moisture or dust, etc.
12. If this product will be used in a sealed environment, such as inside an inspection box, a ventilation fan should be installed to
ensure adequate ventilation as this product can generate heat
in some operating conditions.
When the power is turned on, a noise may be generated as a
means of checking the operating condition of the solenoid
valve. This noise is normal and does not indicate a fault.
2
Breathing
hole
M3 x 0.
5
1. Install an air filter near this product on the supply side.
Select a filtration degree of 5 µm or less.
2. Compressed air containing large amounts of drainage
can cause malfunction of this product and other pneumatic equipment. As a countermeasure, install an aftercooler, air dryer or Drain Catch, etc.
3. If large amounts of carbon dust are generated by the
compressor, it can accumulate inside this product and
cause malfunction.
For details on the above compressed air quality, refer
to SMC's "Air Preparation Systems".
Note)
Brown
Blue
White
Black
Brown
Blue
White
Black
Brown
Blue
White
Black
Specific Product Precautions 2
1.
Screw piping together with the recommended proper torque while holding the side that has female threads.
Looseness or faulty sealing will occur if tightening torque is in-sufficient, while thread damage will result if the torque is ex-cessive. Furthermore, if the side with the female threads is not held while tightening, excessive force will be applied directly to the piping brackets, etc. causing damage or other problems.
2. Do not allow twisting or bending moment to be ap-plied other than the weight of the equipment itself.
Provide separate support for external piping, as damage may otherwise occur.
3. Since excessive moment loads and the propagation of vibrations, etc. can easily result from inflexible piping made of materials such as steel, avoid these problems by using flexible tubing for intermediate connections.
Piping
Warning
1. Preparation before piping
Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and ot-her debris from inside the pipe.
2. Wrapping of pipe tape
When screwing together pipes and fittings, etc., be sure that chips from the pipe threads and sealing material do not get in-side the piping.
Also, when pipe tape is used, leave 1.5 to 2 thread ridges ex-posed at the end of the threads.
Wrappingdirection
Pipe tape
Expose approx.
2
threads
Caution
1. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, or where there will be contact with them.
2. Do not operate in locations where vibration or im-pact occurs.
OperatingEnvironment
1.Employsuitableprotectivemeasuresinlocationswhere there is contact with water droplets, oil or welding spatter, etc.
2. Consult with
SMC when used in power plants, or if
instrumentation related.
Air Supply
Warning
Warning
Caution
Recommended proper torque: N.m
Connection thread
Torque
1/8
1/43/81/2
7 to 912 to 1422 to 2428 to 30
REGULATOR
ITV2000
Series ITV0000/1000/2000/3000
Caution
REGULATOR
ITV2000
Series ITV1000/2000/3000/209 Precautions
1. In locations where the body is exposed to water, steam, dust, etc., there is a possibility that moisture or dust could enter the body through the EXH (sole-noid) ports, thereby causing problems.
2. To overcome this, simply install tubing to each port, using the fittings, and extend the tubing so that the other end is at a location where no water splash, etc. occurs. Make sure not to bend, or block the I.D. of the tubing as this
will have a detrimental effect
on the pressure control.
3.
Do not operate in locations where vibration or im-pact occurs.
4. In locations which receive direct sunlight, provide a protective cover, etc.
5.
In locations near heat sources, block off any radia-ted heat.
6. In locations where there is contact with spatter fromwater, oil or solder etc., implement suitable protecti-ve measures.
1. Install an air filter near this product on the supply side. Select a filtration degree of 5
µm or less.
2. Compressed air containing large amounts of drai-nage can cause malfunction of this product and ot-herpneumaticequipment.Asacountermeasure,install an aftercooler, air dryer or Drain Catch, etc.
3. If large amounts of carbon dust are generated by the compressor,
it can accumulate inside this pro-duct and cause malfunction. For details on the abo-ve compressed air quality, refer to SMC's "Air Pre-paration Systems".
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 3
Specific Product Precautions 2
1.
Screw piping together with the recommended proper
torque while holding the side that has female threads.
Looseness or faulty sealing will occur if tightening torque is insufficient, while thread damage will result if the torque is excessive. Furthermore, if the side with the female threads is not
held while tightening, excessive force will be applied directly to
the piping brackets, etc. causing damage or other problems.
2. Do not allow twisting or bending moment to be applied other than the weight of the equipment itself.
Provide separate support for external piping, as damage may
otherwise occur.
3. Since excessive moment loads and the propagation
of vibrations, etc. can easily result from inflexible
piping made of materials such as steel, avoid these
problems by using flexible tubing for intermediate
connections.
Piping
Warning
1. Preparation before piping
Before piping is connected, it should be thoroughly blown out
with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.
2. Wrapping of pipe tape
When screwing together pipes and fittings, etc., be sure that
chips from the pipe threads and sealing material do not get inside the piping.
Also, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads.
Wrapping
direction
Pipe tape
Expose approx.
2
threads
Caution
1. Do not operate in locations having an atmosphere
of corrosive gases, chemicals, sea water, or where
there will be contact with them.
2. Do not operate in locations where vibration or impact occurs.
Operating Environment
1. Employ suitable protective measures in locations
where there is contact with water droplets, oil or
welding spatter, etc.
2. Consult with
SMC when used in power plants, or if
instrumentation related.
Air Supply
Warning
Warning
Caution
Recommended proper torque: N.m
Connection thread
Torque
1/8
1/43/81/2
7 to 912 to 1422 to 2428 to 30
REGULATOR
ITV2000
Series ITV0000/1000/2000/3000
Caution
REGULATOR
ITV2000
Series ITV1000/2000/3000/209 Precautions
1. In locations where the body is exposed to water,
steam, dust, etc., there is a possibility that moisture
or dust could enter the body through the EXH (solenoid) ports, thereby causing problems.
2. To overcome this, simply install tubing to each port,
using the fittings, and extend the tubing so that the
other end is at a location where no water splash,
etc. occurs. Make sure not to bend, or block the I.D.
of the tubing as this
will have a detrimental effect
on the pressure control.
3.
Do not operate in locations where vibration or im-
pact occurs.
4. In locations which receive direct sunlight, provide a
protective cover, etc.
5.
In locations near heat sources, block off any radia-
ted heat.
6. In locations where there is contact with spatter from
water, oil or solder etc., implement suitable protective measures.
1. Install an air filter near this product on the supply
side. Select a filtration degree of 5
µm or less.
2. Compressed air containing large amounts of drainage can cause malfunction of this product and other pneumatic equipment. As a countermeasure,
install an aftercooler, air dryer or Drain Catch, etc.
3. If large amounts of carbon dust are generated by
the compressor,
it can accumulate inside this product and cause malfunction. For details on the above compressed air quality, refer to SMC's "Air Preparation Systems".
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions,
“Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 4
Specific Product Precautions 3
Series ITV0000/1000/2000/3000
1. Do not use a lubricator on the supply side of this
product, as this can cause malfunction. When lubrication of terminal equipment is necessary, connect
a lubricator on the output side of this equipment.
2. If electric power is shut off while pressure is being
applied, pressure will be retained on the output side.
However, this output pressure is held only temporarily and is not guaranteed. If exhausting of this
pressure is desired, shut off the power after reducing the set pressure, and discharge the air using a
residual pressure exhaust valve, etc.
3. If power to this product is cut off due to a power failure, etc. when it is in a controlled state, output
pressure will be retained temporarily. Handle carefully when operating with output pressure released
to the atmosphere, as air will continue to flow out.
4. If supply pressure to this product is interrupted while the power is still on, the internal solenoid valve
will continue to operate and a humming noise may
be generated. Since the life of the product may be
shortened, shut off the power supply also when
supply pressure is shut off.
5. In this product, the output side pressure cannot be
completely relieved within the range of 0.005 MPa or
less. If it is desired to reduce the pressure completely to 0 MPa, install a 3 way valve or other device
on the output side to exhaust the pressure.
6. This product is adjusted for each specification at
the time of shipment from the factory. Avoid careless disassembly or removal of parts, as this can
lead to malfunction.
7. The optional cable connector is a 4 wire type. When
the monitor output (analogue output or switch output) is not being used, keep it from touching the other wires as this can cause malfunction.
8. Please note that the right angle cable does not rotate and is limited to only one entry direction.
9. Take the following steps to avoid malfunction due
to noise.
1) Remove power supply noise during operation by installing a
line filter, etc. in the AC power line.
2) For avoiding the influence of noise or static electricity, install
this product and its wiring as far as possible from strong
electric fields such as those of motors and power lines, etc.
3) Be sure to implement protective measures against load sur-
ge for induction loads (solenoid valves, relays, etc.).
Handling
Caution
10. Due to the large volume of the output side, a loud
exhaust noise will be produced when being used for
the purpose of a relief function. Therefore, install a
silencer
(SMC Series AN200 or AN400) on the ex-
haust port
(EXH port). The port sizes are Rc 1/8, Rc
1/4 and Rc 1/2.
11. Specifications on page 10 is in case of static environment. Pressure may fluctuate when air is consumed at the output side.
12. For details on the handling of this product, refer to
the instruction manual which is included with the
product.
Handling
Caution
Series ITV1000/2000/3000/209 Precautions
Design and Selection
Caution
1. The direct-current power supply to combine should
be UL authorized power supply.
(1) Limited voltage current circuit in accordance with UL 508.
A circuit in which power is supplied by the secondary coil of a
transformer that meets the following conditions.
• Maximum voltage (with no load):
30 Vrms (42.4 V peak) or less
• Maximum current:
(1) 8 A or less (including when short circuited)
(2) limited by circuit protector (such as fuse) with the follow-
ing ratings.
(2) A circuit using max. 30 Vrms or less (42.4 V peak), which is
powered by UL1310 or UL1585 compatible Class-2 power
supply.
2. Operate these products only within the specified
voltage.
Using voltages beyond the specified levels could cause
faults or malfunctions.
3.
Use 0 V as the baseline for the power supplied to
the unit for output, control and input.
0 V
Output power
Control/input power
+24
V
+24
V
0 V
Output power
Control/input power
–24
V
+24
V
No load voltage (V peak)
0 to 20 [V]
Above 20 to 30 [V]
Max. current rating
5.0
100
Peak voltage
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions,
“Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Specific Product Precautions 4
Connect the cable to the connector on the body with thewiringarrangedasshownbelow.Proceedcarefully, as incorrect wiring can cause damage.Further, use DC power with sufficient capacity and a low ripple.
Caution
Brown
Blue
White
Black
Note)
Body
Wiring diagram
Current signal type
Analogue output: Voltage type
Switch output: NPN type
Switch output: PNP type
Vs
Vs
A
Voltage signal type
Monitor output voltage
Blue
Brown
White
Black
Vs
Vin
Vs : Power supply24VDC
12to15VDC
A : Input signal4to2
0mADC
0to2
0mADC
Vs : Power supply 24 VDC
12 to 15 VDC
Vs : Power supply
24 VDC
12 to15 VDC
Vin
: Input signal
0 to 5 VDC0 to 10 VDC
RESET
Preset input type
S1S2
Preset pressure
OFFOFF
P1
ON
OFF
P2
OFF
ON
P3
ONONP4
S2
S1
Monitor output wiring diagram
Monitor output voltage
Series ITV0000/1000/2000/3000
DeviceNet Power
2
2
3
1
4
1
4
5
3
Pin No.
12345
CC-Link
SLD
DB
DG
DA
NC
PROFIBUS DP
NC
RxD/TxD-N
NC
RxD/TxD-P
NC
RS-232C
NCTxDRxD
GND
NC
DeviceNet™
DRAIN
V+
V–CAN_HCAN_L
Pin No.
1234
CC-Link
Vcc
FG
GND
NC
PROFIBUS DP
VccNC
GND
NC
RS-232C
VccNC
GND
FG
DeviceNet™
Vcc
No connection
GND
No connection
Power supply connector
Communication connector
Power supply connector
DeviceNet™, RS-232C
PROFIBUS DP
CC-Link
Trademark Information
DeviceNet™ is a trademark of ODVA.
Communication connector
Power supply connector
Power supply connector
2
1
3
5
4
3
2
1
4
4
4
4
1
1
1
5
2
2
2
3
3
3
Communication connector
3: (Blue)1: (Brown)
2: (White)
4: (Black)
1234
Current Signal TypeVoltage Signal Type
Brown
White
Blue
Black
Power supplyInput signalGND (COMMON)Monitor output
1234
Brown
White
Blue
Black
Power supplyInput signal 1GND (COMMON)Input signal 2
Preset Input Type
Brown
Blue
White
Black
Brown
Blue
White
Black
Brown
Blue
White
Black
One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.
∗When 30 mADC or moreis applied, detecting device for overcu-
rrentstarts activating and then emits an error signal. (Error number “5”)
Blue
Brown
White
Black
Load
∗
Blue
Brown
White
Black
Load
∗
Blue
Brown
White
Black
IN/OUT communication connector
The cable is also available in a right-angle type. A right-angle type connector is attached facing left (towards the SUP port). On communicationmodels,theconnectorfacesbackwards(to
-wards the EXH port). Do not attempt to rotate, as the connector does not turn.
Note)
Series ITV1000/2000/3000/209 Precautions
Wiring
∗For safety reasons, it is recommended that one of the preset pressures
be set to 0 MPa.
∗Preset pressures are set based on the minimum unit for output display.
· Note that this is 1 psi for 130-psi types.
MPa
0.01
kgf/cm
2
0.01
bar
0.01
psi
0.1
kPa
1
Analogue output: Current type(Sink type)
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 5
Specific Product Precautions 4
Connect the cable to the connector on the body with
the wiring arranged as shown below. Proceed
carefully, as incorrect wiring can cause damage.
Further, use DC power with sufficient capacity and a
low ripple.
Caution
Brown
Blue
White
Black
Note)
Body
Wiring diagram
Current signal type
Analogue output: Voltage type
Switch output: NPN type
Switch output: PNP type
Vs
Vs
A
Voltage signal type
Monitor output voltage
Blue
Brown
White
Black
Vs
Vin
Vs : Power supply 24 VDC
12 to 15 VDC
A : Input signal4 to 2
0 mADC
0 to 2
0 mADC
Vs : Power supply 24 VDC
12 to 15 VDC
Vs : Power supply
24 VDC
12 to 15 VDC
Vin
: Input signal
0 to 5 VDC
0 to 10 VDC
RESET
Preset input type
S1
S2
Preset pressure
OFF
OFF
P1
ON
OFF
P2
OFF
ON
P3
ON
ON
P4
S2
S1
Monitor output wiring diagram
Monitor output voltage
Series ITV0000/1000/2000/3000
DeviceNet Power
2
2
3
1
4
1
4
5
3
Pin No.
1
2
3
4
5
CC-Link
SLD
DB
DG
DA
NC
PROFIBUS DP
NC
RxD/TxD-N
NC
RxD/TxD-P
NC
RS-232C
NC
TxD
RxD
GND
NC
DeviceNet™
DRAIN
V+
V–
CAN_H
CAN_L
Pin No.
1
2
3
4
CC-Link
Vcc
FG
GND
NC
PROFIBUS DP
Vcc
NC
GND
NC
RS-232C
Vcc
NC
GND
FG
DeviceNet™
Vcc
No connection
GND
No connection
Power supply connector
Communication connector
Power supply connector
DeviceNet™, RS-232C
PROFIBUS DP
CC-Link
Trademark Information
DeviceNet™ is a trademark of ODVA.
Communication connector
Power supply connector
Power supply connector
2
1
3
5
4
3
2
1
4
4
4
4
1
1
1
5
2
2
2
3
3
3
Communication connector
3: (Blue)1: (Brown)
2: (White)
4: (Black)
1
2
3
4
Current Signal Type
Voltage Signal Type
Brown
White
Blue
Black
Power supply
Input signal
GND (COMMON)
Monitor output
1
2
3
4
Brown
White
Blue
Black
Power supply
Input signal 1
GND (COMMON)
Input signal 2
Preset Input Type
Brown
Blue
White
Black
Brown
Blue
White
Black
Brown
Blue
White
Black
One of the preset pressures P1 through P4 is selected by the
ON/OFF combination of S1 and S2.
∗ When 30 mADC or more is applied, detecting device for overcu-
rrentstarts activating and then emits an error signal. (Error number “5”)
Blue
Brown
White
Black
Load
∗
Blue
Brown
White
Black
Load
∗
Blue
Brown
White
Black
IN/OUT communication connector
The cable is also available in a right-angle type. A right-angle
type connector is attached facing left (towards the SUP port). On
communication models, the connector faces backwards (to
wards the EXH port). Do not attempt to rotate, as the connector
does not turn.
Note)
Series ITV1000/2000/3000/209 Precautions
Wiring
∗ For safety reasons, it is recommended that one of the preset pressures
be set to 0 MPa.
∗ Preset pressures are set based on the minimum unit for output display.
· Note that this is 1 psi for 130-psi types.
MPa
0.01
kgf/cm
2
0.01
bar
0.01
psi
0.1
kPa
1
Analogue output: Current type
(Sink type)
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions,
“Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 6
Specific Product Precautions 5
Regulating pressure range, by unit of standard measured pressure
Unit
MPa
kgf/cm
2
bar
psi
kPa
Set Pressure Range
CE Mark
The regulating pressure range, by unit of standard
measured pressure, is shown in the table below.
In case that a CE marked ITV (including a special
product) is used with a cable which is purchased
separately, mount a ferrite core to the cable if it is
necessary according to the table below.
ITV01
ITV03
Regulating pressure range
ITV05
0.005 to 0.1
0.05 to 1
0.05 to 1
0.7to 15
5to 100
0.005 to 0.5
0.05 to 5
0.05 to 5
0.7to 70
5to 500
ModelFerrite core
Recommended
power cable part No.
ITV0000--Q
ITV0000 series
Not necessaryM8-4DSX3MG4
(Straight type)
ELWIKA-KV4408 PVC025 2M
(Right angle type)
ModelFerrite core
Recommended
power cable part No.
ITV--Q
ITV1000/2000/3000 series
Necessary
ITV-CC-Q
Not necessary
ITV-DN-Q
Necessary
(Ferrite core is
attached to the body)
ITV-PR-Q
ITV-RC-Q
Necessary
(Ferrite core is
attached to the body)
P398010-12 (Straight type)
(With ferrite core)
P398010-13 (Right angle
type) (With ferrite core)
P398020-500-3
(Straight type)
P398020-501-3
(Right angle type)
P398020-504-3
(Straight type)
P398020-505-3
(Right angle type)
P398020-500-3
(Straight type)
P398020-501-3
(Right angle type)
0.005 to 0.9
0.05 to 9
0.05 to 9
0.7to 130
5to 900
Series ITV0000/1000/2000/3000
ITV209
—
—
—
—
–1.3 to –80
Note) Length of the recommended cable is 3m (however, ELWIKAKV4408 PVC025 2M is 2 metres. Consult SMC for length of other cables)
Series ITV1000/2000/3000/209 Precautions
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions,
“Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Specific Product Precautions 6
Series ITV0000/1000/2000/3000
Handling
1. Connect the vacuum pump to the port, which is la-beled “VAC”.
2.Pressure adjustment changes from “atmospheric pressure to vacuum pressure” when the input sig-nal is increased, and from “vacuum pressure to at-mospheric pressure” when the input signal is de-creased.
3.When adjusting the vacuum pressure, be careful not to block the atmospheric pressure inlet port labeled “ATM”.
4.Since this product is designed exclusively for use with negative pressure, be careful not to apply posi-tive pressure in error.
5. In cases where the vacuum pump being used has a relatively small capacity, or the piping has a small inside diameter, etc., large variations in the set pressure (the range of pressure variation when changing from no flow to flow state) may appear. In this situation, the vacuum pump or the piping, etc. should be changed. In cases where it is not practi-cal to change the vacuum pump, install a capacity tank (volume depending on the operating condi-tions) on the VAC side.
6. The vacuum pressure response time after a change in the input signal is influenced by the internal volu-me on the setting side (including piping). Since the capacity of the vacuum pump also influences the response time, give careful consideration to these points before operation.
7.If the electric power is shut off when in a control state, the pressure on the setting side will go into a holding condition. However, this setting side pres-sure will be held only temporarily and is not guaran-teed. In addition, when atmospheric pressure is de-sired, shut off the power after reducing the set pres-sure, and then introduce atmospheric pressure by using a vacuum release valve, etc.
8.If the power for this product is cut off by a power failure, etc. when it is in a controlled state, the set-ting side pressure will be held temporarily. Further, if operated without sealing the setting side so that atmospheric air is sucked in, handle with care as air will continue to be sucked in.
9.
If the VAC side pressure to this product is interrup-ted while the power is still on, the internal solenoid valve
will continue to operate and may cause a humming noise. Since this may shorten the life of the product, be sure to shut off the power when the VAC side pressure is shut off.
10.
The setting side pressure cannot be completely re-leased from this product in the range below –1.3 kPa. In cases where the pressure needs to be redu-ced completely to 0 kPa, install a 3 port valve, etc. on the setting side to discharge the residual pressu-re.
12. The optional cable connector is a 4-wire type. When the monitor output (analog output, switch output) is not being used, keep
it from touching the other wi-
res, as this can cause malfunction.
13.
Use caution that the right angle cable does not rota-
te and is limited to only one entry direction.
14.
Take the following steps to avoid malfunction due to noise.
1) Eliminate power supply noise during operation by installing
a line filter, etc. in the AC power line.
2) For avoiding the influence of noise or static electricity, install
this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc.
3) Make sure to take protective measures against load surge
for an induction load (solenoid valves, relays, etc.).
15.Refer to the instruction manual included with the product for details on its handling.
Caution
Series ITV009/209 Precautions
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 7
Specific Product Precautions 6
Series ITV0000/1000/2000/3000
Handling
1. Connect the vacuum pump to the port, which is labeled “VAC”.
2. Pressure adjustment changes from “atmospheric
pressure to vacuum pressure” when the input signal is increased, and from “vacuum pressure to atmospheric pressure” when the input signal is decreased.
3. When adjusting the vacuum pressure, be careful not
to block the atmospheric pressure inlet port labeled
“ATM”.
4. Since this product is designed exclusively for use
with negative pressure, be careful not to apply positive pressure in error.
5. In cases where the vacuum pump being used has a
relatively small capacity, or the piping has a small
inside diameter, etc., large variations in the set
pressure (the range of pressure variation when
changing from no flow to flow state) may appear. In
this situation, the vacuum pump or the piping, etc.
should be changed. In cases where it is not practical to change the vacuum pump, install a capacity
tank (volume depending on the operating conditions) on the VAC side.
6. The vacuum pressure response time after a change
in the input signal is influenced by the internal volume on the setting side (including piping). Since the
capacity of the vacuum pump also influences the
response time, give careful consideration to these
points before operation.
7. If the electric power is shut off when in a control
state, the pressure on the setting side will go into a
holding condition. However, this setting side pressure will be held only temporarily and is not guaranteed. In addition, when atmospheric pressure is desired, shut off the power after reducing the set pressure, and then introduce atmospheric pressure by
using a vacuum release valve, etc.
8. If the power for this product is cut off by a power
failure, etc. when it is in a controlled state, the setting side pressure will be held temporarily. Further,
if operated without sealing the setting side so that
atmospheric air is sucked in, handle with care as air
will continue to be sucked in.
9.
If the VAC side pressure to this product is interrupted while the power is still on, the internal solenoid
valve
will continue to operate and may cause a
humming noise. Since this may shorten the life of
the product, be sure to shut off the power when the
VAC side pressure is shut off.
10.
The setting side pressure cannot be completely released from this product in the range below –1.3
kPa. In cases where the pressure needs to be reduced completely to 0 kPa, install a 3 port valve, etc.
on the setting side to discharge the residual pressure.
11.
This product is adjusted for each specification at the
factory before shipment. Avoid careless disas
-
sembly or removal of parts, as this can cause failu
-
re.
12. The optional cable connector is a 4-wire type. When
the monitor output (analog output, switch output) is
not being used, keep
it from touching the other wi-
res, as this can cause malfunction.
13.
Use caution that the right angle cable does not rotate and is limited to only one entry direction.
14.
Take the following steps to avoid malfunction due to
noise.
1) Eliminate power supply noise during operation by installing
a line filter, etc. in the AC power line.
2) For avoiding the influence of noise or static electricity, install
this product and its wiring as far as possible from strong
electric fields such as those of motors and power lines, etc.
3) Make sure to take protective measures against load surge
for an induction load (solenoid valves, relays, etc.).
15. Refer to the instruction manual included with the
product for details on its handling.
Caution
Series ITV009/209 Precautions
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions,
“Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 8
SMC CORPORATION
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362
Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
ARGENTINA, AUSTRALIA, BOLIVIA, BRASIL, CANADA, CHILE,
CHINA, HONG KONG, INDIA, INDONESIA, MALAYSIA, MEXICO,
Entek Pnömatik San. ve Tic. A*.
Perpa Ticaret Merkezi B Blok Kat:11 No: 1625, TR-34386, Okmeydani, Istanbul
Phone: +90 (0)212-444-0762, Fax: +90 (0)212-221-1519
E-mail: smc@entek.com.tr
http://www.entek.com.tr