SMC PNEUMATIK ITV2050-31F3N-Q Datasheet [it]

Series ITV2000 Series ITV3000
Series
ITV009
Series
ITV209
Series
ITV
Electro-Pneumatic Regulator Electronic Vacuum Regulator
Reduced wiring
Reduced wiring
Compact & light Weight:
350
g
Note 1)
(ITV1000)
Power consumption:
4
W
Note 1)
or less
Compact & light Weight:
350
g
Note 1)
(ITV1000)
Power consumption:
4
W
Note 1)
or less
Electro-Pneumatic Regulators
Electro-Pneumatic Regulators
Maximum flow rate
6
l
/
min (ANR)
Set pressure: 0.6 MPa Supply pressure: 1.0 MPa
Maximum flow rate
200
l
/
min (ANR)
Set pressure: 0.6 MPa Supply pressure: 1.0 MPa
Non-grease model (wetted parts)
Maximum flow rate
1500
l
/
min (ANR)
Set pressure: 0.6 MPa Supply pressure: 1.0 MPa
Maximum flow rate
4000
l
/
min (ANR)
Set pressure: 0.6 MPa Supply pressure: 1.0 MPa
RoHS compliant
IP65
Electronic Vacuum Regulators
Electronic Vacuum Regulators
Note 2) ITV1000. Dimensions in parentheses ( ) are for CC-Link or PROFIBUS DP.
Series ITV0000 Series ITV1000
Built-in communication board, so no converter needed.
N
e
w
New
ITV009/209 are IP65 equivalent.
Now with RS-232C serial communications capability!
Now with RS-232C serial communications capability!
Note 1) Value for communications type. (PROFIBUS DP)
50
50
98(108)
Note 2)
Stepless control of air pressure proportional to an electrical signal Fieldbus compatibility added to
Series
ITV1000/2000/3000
specifications!
Stepless control of air pressure proportional to an electrical signal Fieldbus compatibility added to
Series
ITV1000/2000/3000 specifications!
CAT.EUS60-15E-UK
New
New
New
New
Series
ITV
Electro-Pneumatic Regulator Electronic Vacuum Regulator
Electro-Pneumatic RegulatorElectronic Vacuum Regulator
Page
Series Model
Regulating pressure range
Port size
ITV001
ITV003
ITV005
0.001 to 0.1 MPa
0.001 to 0.5 MPa
0.001 to 0.9 MPa
Built-in
One-touch fittings
Metric size: ø4
Inch size: ø5/32
1
9
Series ITV2000
ITV201
ITV203
ITV205
0.005 to 0.1 MPa
0.005 to 0.5 MPa
0.005 to 0.9 MPa
1/4, 3/8
9
Series ITV1000
ITV101
ITV103
ITV105
0.005 to 0.1 MPa
0.005 to 0.5 MPa
0.005 to 0.9 MPa
1/8, 1/4
9
Series ITV3000
ITV301
ITV303
ITV305
0.005 to 0.1 MPa
0.005 to 0.5 MPa
0.005 to 0.9 MPa
1/4, 3/8, 1/2
Series ITV0000
ITV009
–1 to –100 kPa
Built-in
One-touch fittings
Metric size: ø4
Inch size: ø5/32
27
Series ITV009
ITV209
–1.3 to –80 kPa 1/4
34
Series ITV209
Stepless control of air pressure proportional to an electrical signal.
Input signal
Current type:
4 to 20 mA DC
Current type:
0 to 20 mA DC
Voltage type:
0 to 5 V DC Voltage type: 0 to 10 V DC
Current type:
4 to 20 mA DC
(Sink type)
Current type:
0 to 20 mA DC
(Sink type)
Voltage type:
0 to 5 V DC Voltage type: 0 to 10 V DC
Preset input
New
CC-Link compatible
New
DeviceNet™ compatible
New
PROFIBUS DP compatible
New
RS-232C communication
Current type:
4 to 20 mA DC
Current type:
0 to 20 mA DC
Voltage type:
0 to 5 V DC Voltage type: 0 to 10 V DC
Current type:
4 to 20 mA DC (Sink type)
Current type:
0 to 20 mA DC (Sink type)
Voltage type:
0 to 5 V DC Voltage type: 0 to 10 V DC
Preset input
New
CC-Link compatible
New
DeviceNet™ compatible
New
PROFIBUS DP compatible
New
RS-232C communication
Features 2
How to Order
ITV
Pressure range
3
0
1 0
1 3 5
0.1 MPa
0.5 MPa
0.9 MPa
S Q
0 1 2
2 3 4 5
MPa
kgf/cm
2
bar psi
kPa
Input signal
0 1 2 3
4 CC DN PR RC
Cable connector type
S L N
Straight type 3 m
Right angle type 3
m
Without cable connector
Bracket
B C
Without bracket
Flat bracket
L-bracket
Monitor output
0 1 2 3 4
Thread type
N T F
Rc
NPT
NPTF
G
Port size
1 2 3 4
1/8 (1000 type)
1/4 (1000, 2000, 3000 type)
3/8 (2000, 3000 type)
1/2 (3000 type)
Power supply voltage
0 1
24 VDC
12 to 15 VDC
Model
1 2 3
1000 type 2000 type 3000
type
Note)
Note)
Current type 4 to 20 mA (Sink type) Current type 0 to 20 mA (Sink type)
Voltage type 0 to 5 VDC
Voltage type 0 to 10 VDC
Preset input
CC-Link
DeviceNet™
PROFIBUS DP
RS-232C communication
None (for communication models)
None (for preset input)
Analogue output 1 to 5V DC
Switch output/NPN output Switch output/PNP output
Analog output 4 to 20 mA (Sink type)
Note) Communication
models are availa­ble only for 24 V DC
Pressure display unit
Made to Order Specifications
See pages 11, 25, and 26 for details.
CE compliant
Q
CE compliant
∗ For detailed information on
CE marked models, refer to SMC's website.
Note) Only for overseas sales (SI units are
to be used inside Japan). No units are displayed on communication models.
Note) Communication cable (other than RS-
232C) should be obtained separately. See below.
Application
CC-Link compatibility
DeviceNet™ compatibility
PROFIBUS DP compatibility
Communication cable part number
PCA-1567720 (Socket type) PCA-1567717 (Plug type) PCA-1557633 (Socket type) PCA-1557646 (Plug type) PCA-1557688 (Socket type) PCA-1557691 (Plug type)
Remarks
Dedicated Bus adapter supplied with the product.
T-branch connector not supplied.
T-branch connector not supplied.
For communication cables, use the parts listed below (refer to the catalogue [M8/M12 Connector] CAT.EUS100-73-UK for details) or order the product certified for the respective protocol (with M12 connector) separately.
Electro-Pneumatic Regulator
Series
ITV1000/2000/3000
Model
Maximum supply pressure
Minimum supply pressure
24 VDC ± 10%, 12 to 15 VDC
Set pressure +0.1 MPa
Set pressure range
Note 1)
0.2 MPa
Input signal
Input impedance
Output pressure display
Note 4)
Weight
Note 9)
Accuracy
Minimum unit
ITV10 ITV20

ITV30

Ambient and fluid temperature
Enclosure
1.0 MPa
0.005 to 0.1 MPa 0.005 to 0.5 MPa 0.005 to 0.9 MPa
JIS Symbol
4 to 20 mA, 0 to 20 mA (Sink type)
0 to 5 VDC, 0 to 10 VDC
4 points
250
or less
Note 6)
Approx. 6.5 k
Approx. 2.7
k
Linearity
Hysteresis
Repeatability
Sensitivity
Temperature characteristics
Power supply
Voltage Current
consumption
Within ±1% (Full span)
Within 0.5% (Full span)
Within
±0.5% (Full span)
Within 0.2% (Full span)
Within ±0.12% (Full span)/°C
±3% (Full span)
MPa: 0.01, kgf/cm
2
: 0.01, bar: 0.01, PSI: 0.1
Note 5)
, kPa: 1
0 to 50
°C (No condensation)
IP65
Approx. 250 g (without options)
Approx. 350 g (without options)
Approx. 645 g (without options)
NPN open collector output: Max. 30 V, 30 mA
PNP open collector output: Max. 30 mA
Power supply voltage 24 VDC type: 0.12 A or less
Power supply voltage 12 to 15 VDC type: 0.18 A or less
ITV105 ITV205
ITV305
ITV103
ITV203
ITV303
ITV101
ITV201
ITV301
1 to 5 VDC (Load impedance: 1 k or more)
4 to 20 mA (Sink type) (Load impedance: 250
or less)
Output accuracy within
±6% (Full span)
Input/output characteristics chart
Input signal (%F.S.)
0
0 100
Output pressure
(MPa)
This range is outside of the control (output).
0.005MPa
Rated pressure
ITV3000 Fieldbus-compatible
model
ITV2000ITV1000
Note 1) Please refer to Figure 1 for the relationship between set pressure and input. Because the maximum set pres-
sure differs for each pressure display, refer to Appendix 7. Additionally, refer to page 18 for the set pressure range by units of standard measured pressure.
Additionally, refer to page 18 as maximum set pressure differs on unit of standard measure. Note 2) 2-wire type 4 to 20 mA is not available. Power supply voltage (24 VDC or 12 to 15 VDC) is required. Note 3) Select either analogue output or switch output.
Further, when switch output is selected, select either NPN output or PNP output. Note
4)
Adjustment of numerical values such as the zero/span adjustment or preset input type is set based on the mi-
nimum units for output pressure display (e.g. 0.01 to 0.50 MPa). Note that the unit cannot be changed. Note 5) The minimum unit for 0.9 MPa (130 psi) types is 1 psi. Note 6)
Value for the state with no over current circuit included. If an allowance is provided for an over current circuit,
the input impedance varies depending on the input current. This
is 350 or less for an input current of 20
mA DC. Note 7) The above characteristics are confined to the static state. When air is consumed on the output side, the pres-
sure may fluctuate. Note 8) For communication models, the maximum current consumption is 0.16 A or less. Note 9) For communication models, add roughly 80 g to the weight (100 g for the PROFIBUS DP). Note 10) The ITV1000 series is a non-grease model (Wetted parts).
Standard Specifications
Note 10) Note 10) Note 10)
Current type
Note 2)
Voltage type
Preset input
Current type
Voltage type
Preset input
Switch output
Analogue output
Output signal (monitor output)
Note 3)
Protocol
Version
Note 1)
Configulation file
Note 2)
I/O occupation area (input/output data)
Communication data resolution
Fail safe
Note 4)
Terminating resistance
Communication speed
Communication Specifications
Model
ITV00-CC
CC-Link
Ver 1.10
12 bit (4096 resolution)
ITV00-DN
DeviceNet™
Release2.0
EDS
16 bit/16 bit
12 bit (4096 resolution)
ITV00-PR
PROFIBUS DP
DP-V0
GSD
16 bit/16 bit
12 bit (4096 resolution)
CLEAR
ITV00-RC
RS-232C
9.6 kbps
10 bit (1024 resolution)
HOLD
Note 1) Note that this version information is subject to change. Note 2) Configulation files can be downloaded from SMC's website: http://www.smc.eu Note 3) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data. Note 4) It shows the insulation between electric signal for communication and the ITV supply power.
156 k/625 k
2.5 M/5 M/10 M bps
125 k/250 k/500 k bps
9.6 k/19.2 k/45.45
k
93.75 k/187.5 k/500
k
1.5 M/3 M/6 M/12 M bps
Built into the product
(Switch setting)
HOLD/CLEAR
(Switch setting)
4 word/4 word, 32 bit/32 bit
(per station, remote device station)
HOLD
Note 3)
/CLEAR
(Switch setting)
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
9
Electro-Pneumatic Regulator
Standard Specifications
Series ITV1000/2000/3000
ITV2000ITV1000
ITV3000 Fieldbus-compatible
model
JIS Symbol
Rated pressure
(MPa)
Output pressure
0.005MPa 0
This range is outside of the control (output).
0 100
Input signal (%F.S.)
Input/output characteristics chart
Communication Specifications
Note 10) Note 10) Note 10)
ITV101
Model
Minimum supply pressure
Maximum supply pressure
Set pressure range
Note 1)
Voltage
Power supply
Current consumption
Note 2)
Current type
Input signal
Voltage type
ITV201
ITV301
Set pressure +0.1 MPa
0.2 MPa
0.005 to 0.1 MPa 0.005 to 0.5 MPa 0.005 to 0.9 MPa
24 VDC ± 10%, 12 to 15 VDC
Power supply voltage 24 VDC type: 0.12 A or less
Power supply voltage 12 to 15 VDC type: 0.18 A or less
4 to 20 mA, 0 to 20 mA (Sink type)
0 to 5 VDC, 0 to 10 VDC
Preset input
Note 3)
Current type
Voltage type
Preset input
Analogue output
Switch output
Input impedance
Output signal (monitor output)
Linearity
Hysteresis
Repeatability
Sensitivity
Temperature characteristics
Note 4)
Accuracy
Minimum unit
Output pressure display
Ambient and fluid temperature
1 to 5 VDC (Load impedance: 1 k or more)
4 to 20 mA (Sink type) (Load impedance: 250
Output accuracy within ±6% (Full span)
NPN open collector output: Max. 30 V, 30 mA
PNP open collector output: Max. 30 mA
MPa: 0.01, kgf/cm
250
Approx. 6.5 k
Approx. 2.7
Within ±1% (Full span)
Within 0.5% (Full span)
Within
Within 0.2% (Full span)
Within
±0.12% (Full span)/°C
±3% (Full span)
2
: 0.01, bar: 0.01, PSI: 0.1
0 to 50
°C (No condensation)
Enclosure
ITV10
Note 9)
Weight
Note 1) Please refer to Figure 1 for the relationship between set pressure and input. Because the maximum set pres-
sure differs for each pressure display, refer to Appendix 7. Additionally, refer to page 18 for the set pressure range by units of standard measured pressure.
Additionally, refer to page 18 as maximum set pressure differs on unit of standard measure. Note 2) 2-wire type 4 to 20 mA is not available. Power supply voltage (24 VDC or 12 to 15 VDC) is required. Note 3) Select either analogue output or switch output.
Further, when switch output is selected, select either NPN output or PNP output. Note
4)
Adjustment of numerical values such as the zero/span adjustment or preset input type is set based on the mi-
nimum units for output pressure display (e.g. 0.01 to 0.50 MPa). Note that the unit cannot be changed. Note 5) The minimum unit for 0.9 MPa (130 psi) types is 1 psi.
Value for the state with no over current circuit included. If an allowance is provided for an over current circuit,
Note 6)
the input impedance varies depending on the input current. This
mA DC. Note 7) The above characteristics are confined to the static state. When air is consumed on the output side, the pres-
sure may fluctuate. Note 8) For communication models, the maximum current consumption is 0.16 A or less. Note 9) For communication models, add roughly 80 g to the weight (100 g for the PROFIBUS DP). Note 10) The ITV1000 series is a non-grease model (Wetted parts).
ITV20 ITV30
 
Approx. 250 g (without options)
Approx. 350 g (without options)
Approx. 645 g (without options)
ITV103 ITV203
ITV303
1.0 MPa
4 points
or less
Note 6)
k
±0.5% (Full span)
IP65
is 350 or less for an input current of 20
ITV105 ITV205 ITV305
or less)
Note 5)
, kPa: 1
 
Model
Protocol
Note 1)
Version
Communication speed
Configulation file
Note 2)
I/O occupation area (input/output data)
Communication data resolution
Fail safe
Note 4)
Terminating resistance
Note 1) Note that this version information is subject to change. Note 2) Configulation files can be downloaded from SMC's website: http://www.smc.eu Note 3) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data. Note 4) It shows the insulation between electric signal for communication and the ITV supply power.
ITV00-CC
CC-Link
Ver 1.10
156 k/625 k
2.5 M/5 M/10 M bps
4 word/4 word, 32 bit/32 bit
(per station, remote device station)
12 bit (4096 resolution)
Note 3)
HOLD
(Switch setting)
/CLEAR
ITV00-DN
DeviceNet™
Release2.0
125 k/250 k/500 k bps
EDS
16 bit/16 bit
12 bit (4096 resolution)
HOLD/CLEAR
(Switch setting)
ITV00-PR
PROFIBUS DP
9.6 k/19.2 k/45.45
93.75 k/187.5 k/500
1.5 M/3 M/6 M/12 M bps
12 bit (4096 resolution)
Built into the product
(Switch setting)
DP-V0
GSD
16 bit/16 bit
CLEAR
ITV00-RC
RS-232C
k
k
9.6 kbps
10 bit (1024 resolution)
HOLD
10
Combinations
ITV10 models are not applicable.
ITV10 models are not applicable.
Specifications
1
3
5
02
03
04
B
C
N02
N03
N04
F02
F03
F04
Symbol
Applicable model
ITV20

ITV30

Modular Products and Accessory Combinations
Accessory (Option)/Part No.
q Air filter w Mist separator e L-bracket r
Spacer
t Spacer with L-bracket (e + r) y
Spacer with T-bracket
ITV20

AF30
AFM30
B310L
Y30
Y30L
ITV30

AF40
AFM40
B410L
Y40
Y40L
Y40T
Applicable products and accessories
Applicable model
178
SMC REGULATOR
ITV2000
Approx. 133
Approx. 189
Approx. 172
Approx. 243
234
REGULATOR
ITV3000
qAF40 wAFM40
qAF30 wAFM30
ITV20

ITV30

eL-bracket
rSpacer
Flat bracket
Dimensions
L-bracket
1.6
12
20
60
40
84
40
22
36
52
100
22
4 x ø5.5
8 x ø4.5
4 x ø7
2.3
40 5
22
40
36
7
36
70
22 14
50
4 x ø5.5
8 x ø4.5
(8.5)
7
4
x
R3.5
15
33
10
50
25
Or
de
r
Made
Made to Order
(Refer to pages 25 and 26 for details.)
Symbol
CE-compliant
Specifications
16 points preset input type
Digital input type
Reverse type
High pressure type (SUP 1.2 MPa, OUT 1.0 MPa)
Set pressure range 1 to 100 kPa (Except Series ITV3000)
High speed response type (Except Series ITV3000)
For manifold mounting (Except Series ITV3000)
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
X156
X157
X321
X322
X323
X154
X153
Acces-
sories
Standard
specifications
Optional
specifications
Set pressure max. 0.1 MPa
Set pressure max. 0.5 MPa
Set pressure max. 0.9 MPa
Connection Rc 1/4
Connection Rc 3/8
Connection Rc 1/2
Bracket
Bracket
Connection NPT1/4
Connection NPT3/8
Connection NPT1/2
Connection G 1/4
Connection G 3/8
Connection G 1/2
Note 1)
Manifolds are compatible with 2 to 8 stations. Consult with SMC for 9 stations or more.
Note 2)
Products without symbols are also compatible. Consult with SMC separately.
Combination possible
Combination not possible
Standard specifications
ITV10 ITV20 ITV30
L-bracket assembly (including mounting screws)
Straight type 3
m
Right angle type 3 m
Straight type 3
m
Right angle type 3
m
Straight type 3
m
Right angle type 3
m
Straight type 3 m
Right angle type 3
m
ITV
--Q
ITV
-PR-Q
ITV
-RC-Q
ITV-DN-Q
ITV
-CC-Q
Power cable connector
Description
KT-ITV-F2
KT-ITV-L2
P398010-12
P398010-13
P398020-500-3
P398020-501-3
P398020-504-3
P398020-505-3
P398020-500-3
P398020-501-3
EX9-ACY00-MJ
Part No.
KT-ITV-F1
KT-ITV-L1
Flat bracket assembly (including mounting screws)
Bus adapter (CC-Link model only)
Series ITV1000/2000/3000
Supply pressure
q
Air supply solenoid valve
w
Exhaust solenoid valve
r Diaphragm Pilot valve
u
Pressure sensor
i
Control circuit
Input signal Output pressure
When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF. Therefore, supply pressure passes through the air supply solenoid valve q and is applied to the pilot chamber e. The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r. As a result, the air supply valve t linked to the diaphragm r opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u. Here, a correct operation functions until the output pressure is proportional to the input signal, making possible to obtain output pressure proportional to the input signal always.
ITV2000, 3000
Pressure display
Power supply
Input signal
q Air supply
solenoid valve
r Diaphragm
y Exhaust
valve
t Supply
valve
w Exhaust
solenoid valve
Output signal
u Pressure
sensor
e Pilot
chamber
i Control
circuit
SUP OUT
EXH
EXH
ITV1000
SUP
EXH
OUT
EXH
t Supply valve
w Exhaust
solenoid valve
u Pressure sensor
q Air supply
solenoid valve
Input signal
Power supply Output signal
r Diaphragm
e Pilot chamber
Pressure display
i Control
circuit
Working Principle Diagram
Block diagram
Working Principles
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
11
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Working Principles
When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF. Therefore, supply pressure passes through the air supply solenoid valve q and is applied to the pilot chamber e. The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r. As a result, the air supply valve t linked to the diaphragm r opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u. Here, a correct operation functions until the output pressure is proportional to the input signal, making possible to obtain output pressure proportional to the input signal always.
Working Principle Diagram
Pressure display
Pressure display
Power supply Output signal
Input signal
q Air supply
solenoid valve
r Diaphragm
SUP
i Control
circuit
ITV1000
w Exhaust
solenoid valve
EXH
u Pressure sensor e Pilot chamber
t Supply valve
OUT
EXH
Power supply
Input signal
q Air supply
solenoid valve
r Diaphragm
y Exhaust
valve
t Supply
valve
SUP OUT
i Control
circuit
ITV2000, 3000
Output signal
w Exhaust
solenoid valve
EXH
u Pressure
sensor
e Pilot
chamber
EXH
Block diagram
Supply pressure
Air supply solenoid valve
q
Input signal Output pressure
i
Control circuit
w
Exhaust solenoid valve
u
Pressure sensor
r Diaphragm Pilot valve
12
Series ITV101
Series
ITV201
Pressure characteristics
Flow characteristics
Linearity Hysteresis
0 25 50 75
0.01
0.00
0.03
0.02
0.04
0.08
0.07
0.06
0.05
0.09
0.10
100
0 25 50 7
5
1.0
0.5
0.0
0.5
1.0
100
0.0 0.1 0.2
0.5
0.3
0.0
0.5
1.0
1.0 0 200 400 600
0.05
0.10
0.15
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPaSet pressure: 0.05 MPa
Relief flow characteristics
Repeatability
0 2 64 8
1.0
0.5
0.0
0.5
1.0
10
0 200 400 800
0.05
600
0.10
0.15
0.25
0.20
0.00
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Pressure characteristics
Linearity
Hysteresis
0 25 50 75 100
0 25 50 7
5
1.0
0.5
0.0
0.5
1.0
100
0.0 0.1 0.2
0.5
0.3
0.0
0.5
1.0
1.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure: 0.05 MPa
Relief flow characteristics
Repeatability
0 2 64 8
1.0
0.5
0.0
0.5
1.0
10
0 20 40 8
0
0.05
60
0.10
0.15
0.25
0.20
0.00
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Set point
Out
Return
Flow characteristics
0 20 40 60 80 100
0.05
0.10
0.15
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
0.10
0.08
0.06
0.04
0.02
0.00
0.01
0.03
0.07
0.05
0.09
0.11
Set point
Out
Return
Series ITV1000/2000/3000
Series ITV301
Pressure characteristics
Flow characteristics
Linearity
Hysteresis
0 25 50 75
0.00
0.05
0.04
0.03
0.02
0.01
0.07
0.06
0.09
0.08
0.10
100
0 25 50 75
1.0
0.5
0.0
0.5
1.0
100
0.0 0.1 0.2
0.5
0.3
0.0
0.5
1.0
1.0 0 500 1000 1500 2000
0.05
0.10
0.15
0.00
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Set pressure: 0.05 MPa
Relief flow characteristics
Repeatability
0 2 64 8
1.0
0.5
0.0
0.5
1.0
10
0 500 1000 20001500
0.10
0.05
0.15
0.25
0.20
0.00
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Out
Return
Set point
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
13
Series ITV301
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Linearity
0.10
0.09
0.08
0.07
0.06
0.05
0.04
0.03
Set pressure (MPa)
0.02
0.01
0.00 0 25 50 75
Pressure characteristics
1.0
0.5
0.0
0.5
Output deviation factor (%F.S.)
1.0
0.0 0.1 0.2
Input signal (%F.S.)
Set pressure: 0.05 MPa
Supply pressure (MPa)
100
Set point
0.3
Hysteresis
1.0
0.5
Out
0.0
0.5
Output deviation factor (%F.S.)
1.0 0 25 50 75
Input signal (%F.S.)
Flow characteristics
0.15
0.10
0.05
Set pressure (MPa)
0.00 0 500 1000 1500 2000
Flow rate (l/min (ANR))
Supply pressure: 0.2 MPa
Return
100
Repeatability
1.0
0.5
0.0
0.5
Output deviation factor (%F.S.)
1.0 0 2 64 8
Relief flow characteristics
0.25
0.20
0.15
0.10
Set pressure (MPa)
0.05
0.00 0 500 1000 20001500
Repetition
Supply pressure: 0.2 MPa
Flow rate (l/min (ANR))
10
14
Series
ITV203
Pressure characteristics
Flow characteristics
Linearity
Hysteresis
0 25 50 75
0.0
0.1
0.2
0.4
0.3
0.6
0.5
100 0 25 50 75
1.0
0.5
0.
0
0.
5
1.0
100
0.2 0.4 0.6
0.5
0.8
0.0
0.5
1.0
1.0 0 500 1000 1500 2000
0.4
0.3
0.2
0.1
0.5
0.6
0.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Set pressure: 0.2 MPa
Relief flow characteristics
Repeatability
0 2 64 8
1.0
0.5
0.0
0.5
1.0
10
0 500 1000 2000
0.3
0.2
0.1
1500
0.5
0.4
0.6
0.7
0.8
0.0
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Series ITV103
Linearity
Pressure characteristics
0.2 0.4 0.6
0.5
0.8
0.0
0.5
1.0
1.0
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure: 0.2 MPa
Flow characteristics
0 50 100 150 200 250
0.2
0.1
0.0
0.4
0.3
0.6
0.5
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
0 25 50 75 100
Set pressure (MPa)
Input signal (%F.S.)
0.5
0.6
0.4
0.3
0.2
0.1
0.0
Hysteresis
0 25 50 75
1.0
0.5
0.0
0.5
1.0
100
Output deviation factor (%F.S.)
Input signal (%F.S.)
Repeatability
0 2 64 8
1.0
0.5
0.0
0.5
1.0
10
Output deviation factor (%F.S.)
Repetition
Relief flow characteristics
0 50 100 200150
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Set point
Set point
Out
Return
Out
Return
Series ITV1000/2000/3000
Series ITV303
Pressure characteristics
Flow characteristics
Linearity
Hysteresis
0 25 50 75
0.1
0.0
0.2
0.4
0.3
0.6
0.5
100 0 25 50 75
1.0
0.5
0.0
0.5
1.0
100
0.2 0.4 0.6
0.5
0.8
0.0
0.5
1.0
1.0 0 1000 2000 3000 4000 5000 6000
0.2
0.1
0.4
0.3
0.6
0.5
0.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Set pressure: 0.2 MPa
Relief flow characteristics
Repeatability
0 2 64 8
1.0
0.5
0.0
0.5
1.0
10
0 1000 2000 3000
0.1
50004000
0.3
0.2
0.5
0.4
0.6
0.8
0.7
0.0
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
Set point
Out
Retirm
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
15
Series ITV303
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Linearity
0.6
0.5
0.4
0.3
0.2
Set pressure (MPa)
0.1
0.0 0 25 50 75
Input signal (%F.S.)
Pressure characteristics
1.0
0.5
0.0
0.5
Output deviation factor (%F.S.)
1.0
0.2 0.4 0.6
Supply pressure (MPa)
Set pressure: 0.2 MPa
Hysteresis
1.0
0.5
Out
0.0
Retirm
0.5
Output deviation factor (%F.S.)
100 0 25 50 75
1.0
Input signal (%F.S.)
Flow characteristics
0.6
0.5
Set point
0.8
0.4
0.3
0.2
Set pressure (MPa)
0.1
0.0 0 1000 2000 3000 4000 5000 6000
Flow rate (l/min (ANR))
100
Supply pressure: 0.7 MPa
Repeatability
1.0
0.5
0.0
0.5
Output deviation factor (%F.S.)
1.0 0 2 64 8
Repetition
Relief flow characteristics
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Set pressure (MPa)
0.1
0.0 0 1000 2000 3000
Flow rate (l/min (ANR))
Supply pressure: 0.7 MPa
10
50004000
16
Series ITV105
Series ITV205
Pressure characteristics
Linearity Hysteresis
0 25 50 75
0.1
0.0
0.3
0.2
0.4
0.7
0.6
0.5
0.8
1.0
0.9
100
0 25 50 75
1.0
0.5
0.0
0.5
1.0
100
0.4 0.6 0.8
0.5
1.0 1.2
0.0
0.5
1.0
1.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure: 0.4 MPa
Relief flow characteristics
Repeatability
0 2 64 8
0.5
0.25
0
0.25
0.5
10
0
500 1000 2000 2500
0.2
0.1
1500
0.5
0.4
0.3
0.7
0.6
1.0
0.9
0.8
0.0
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Flow characteristics
0
500 1000 1500 2000 2500
0.5
0.4
0.3
0.2
0.1
0.7
0.6
1.0
0.9
0.8
0.0
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Pressure characteristics
0.4 0.6 0.8 1 1.2
0.5
0.0
0.5
1.0
1.0
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure: 0.4 MPa
Flow characteristics
0 50 100 150 200 250 300 350
0.2
0.1
0.0
0.4
0.3
0.6
0.7
0.8
0.9
1.0
0.5
Supply pressure: 1.0 MPa
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Linearity
0 25 50 75 100
Set pressure (MPa)
Input signal (%F.S.)
0.6
0.7
0.8
0.9
1.0
0.5
0.4
0.3
0.2
0.1
0.0
Hysteresis
0 25 50 75
1.0
0.5
0.0
0.5
1.0
100
Output deviation factor (%F.S.)
Input signal (%F.S.)
Repeatability
0 2 64 8
1.0
0.5
0.0
0.5
1.0
10
Output deviation factor (%F.S.)
Repetition
Relief flow characteristics
0 50 100 150 200 250 300
0.8
0.9
1.0
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Set point
Set point
Out
Return
Out
Return
Series ITV1000/2000/3000
Series ITV305
Pressure characteristics
Flow characteristics
Linearity
Hysteresis
0 25 50 75
0.0
0.3
0.2
0.1
0.4
0.7
0.6
0.5
1.0
0.9
0.8
100 0 25 50 75
1.0
0.5
0.0
0.5
1.0
100
0.4 0.6
0.5
0.8 1.0 1.2
0.0
0.5
1.0
1.0 0
1000 2000 3000 4000 5000 6000 7000
0.4
0.3
0.2
0.1
0.7
0.6
0.5
1.0
0.9
0.8
0.0
Set pressure (MPa)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Input signal (%F.S.)
Output deviation factor (%F.S.)
Supply pressure (MPa)
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Set pressure: 0.4 MPa
Relief flow characteristics
Repeatability
0 2 64 8
1.0
0.5
0.0
0.5
1.0
10
0
1000 2000 5000 6000
0.3
0.2
0.1
3000 4000
0.5
0.4
0.7
0.6
1.0
0.9
0.8
0.0
Output deviation factor (%F.S.)
Repetition
Set pressure (MPa)
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
Set point
Out
Return
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
17
Series ITV305
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Linearity
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Set pressure (MPa)
0.1
0.0 0 25 50 75
Input signal (%F.S.)
Pressure characteristics
1.0
0.5
0.0
0.5
Output deviation factor (%F.S.)
1.0
0.4 0.6
Supply pressure (MPa)
Set pressure: 0.4 MPa
Set point
0.8 1.0 1.2
Hysteresis
1.0
0.5
0.0
0.5
Output deviation factor (%F.S.)
100 0 25 50 75
1.0
Flow characteristics
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
Set pressure (MPa)
0.2
0.1
0.0 0
1000 2000 3000 4000 5000 6000 7000
Out
Return
Input signal (%F.S.)
Supply pressure: 1.0 MPa
Flow rate (l/min (ANR))
100
Repeatability
1.0
0.5
0.0
0.5
Output deviation factor (%F.S.)
1.0 0 2 64 8
Repetition
Relief flow characteristics
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
Set pressure (MPa)
0.2
0.1
0.0 0
1000 2000 5000 6000
Flow rate (l/min (ANR))
Supply pressure: 1.0 MPa
3000 4000
10
18
ITV10
Flat bracket
L-bracket
Note) Do not attempt to rotate, as the cable connector does not turn.
Dimensions
100
84
52
40
50
Mounting hole
4 x ø7
Setting part
Cable connector (4 wire)
Right angle type
(33)
Cable connector (4 wire)
Straight type
(Option)
KT-ITV-F1
Flat bracket
19.5
11
SUP port, OUT port
2 x Rc1/8, 1/4
Exhaust port
Rc 1/8
Solenoid valve EXH
EXH (3)
12.5
Cable connection threads
M12 x 1
40
Mounting hole
4 x M4 x 0.7 thread depth 6 mm through
SUP (1)
M3 x 0.5
Solenoid valve
EXH
Rc 1/8 Pressure gauge
connection port
(11)71
12
OUT (2)
(Option)
KT-ITV-L1
L-bracket
(Option)
KT-ITV-F1
Flat bracket
45
22
2.3
SUP port, OUT port
2
x
Rc1/8, 1/4
(8.5)
7
R3.5
15
33
10
50
25
(Option)
KT-ITV-L1
L-bracket
Series ITV1000/2000/3000
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
CC-Link/ITV100-CC DeviceNet™/ITV100-DN
PROFIBUS DP/
ITV100-PR
RS-232C/
ITV100-RC
With power cable connector
ITV100-
common dimensions
CC DN PR RC
Dimensions not shown are as on P.19.
Note) Communication cable (other than RS-232C) should be obtained separately. (See P.9.)
Dimensions not shown are as on P.19.
Dimensions not shown are as on P.19.
Note) Do not attempt to rotate, as the cable connector does not turn.
Dimensions not shown are as on P.19.
(53)
(11)10812
40
M12 x 1 Power cabl
e
connection thread
Rc 1/8 Pressure gauge connection port
M3 x 0.5
Solenoid valve
EXH
SUP (1) OUT (2)
M12 x 1 Communication cable
connection thread
BUS adapter
10 10
M12 x 1 Reverse connector
M12 x 1
8.5
19.5
11
EXH (3)
Solenoid valve
EXH
Rc 1/8 Exhaust
port
2 x Rc 1/8, 1/4 SUP port, OUT port
(11)9812
10 10
40
M12
x 1
Power cable connection thread
Rc 1/8 Pressure gauge connection port
M3 x 0.5
Solenoid valve
EXH
SUP (1) OUT (2)
M12 x 1 Communication cable
connection thread
10.5 11.5
(11)
(16)
10812
40
M12 x 1 Power cable
connection thread
Rc 1/8 Pressure gauge connection port
M3 x 0.5
Solenoid valve
EXH
SUP (1) OUT (2)
M12 reverse connector Communication cable
connection thread
19.5
11
Rc 1/8 Exhaust
port
2 x Rc 1/8, 1/4 SUP port, OUT port
EXH (3)
Solenoid valve
EXH
9.5
(11)12
10 10
40
M12
x 1
Power cable connection thread
Rc 1/8 Pressure gauge connection port
M3 x 0.5
Solenoid valve
EXH
SUP (1) OUT (2)
M12 x 1 Communication cable connection thread
98
19.5
11
8.5
Rc 1/8 Exhaust
port
2 x Rc 1/8, 1/4 SUP port, OUT port
EXH (3)
Solenoid valve
EXH
19.5
11
8.5
Rc 1/8 Exhaust
port
2 x Rc 1/8, 1/4 SUP port, OUT port
EXH (3)
Solenoid valve
EXH
Cable connector (4 wire)
Straight type
Cable connector (4 wire)
Right angle type
(33)
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
19
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
CC-Link/ITV100-CC DeviceNet™/ITV100-DN
M12 x 1 Reverse connector
BUS adapter
M12 x 1
8.5
M12 x 1 Communication cable
connection thread
10 10
(53)
M12 x 1 Power cabl
connection thread
e
(11)10812
8.5
M12 x 1 Communication cable
connection thread
x 1
M12 Power cable
connection thread
10 10
(11)9812
M3 x 0.5
Solenoid valve
EXH
19.5
11
2 x Rc 1/8, 1/4 SUP port, OUT port
Dimensions not shown are as on P.19.
PROFIBUS DP/
9.5
Solenoid valve
EXH
19.5
11
Solenoid valve
EXH
Rc 1/8 Exhaust
port
EXH (3)
ITV100-PR
M3 x 0.5
Solenoid valve
EXH
Rc 1/8 Exhaust
port
EXH (3)
SUP (1) OUT (2)
40
Rc 1/8 Pressure gauge connection port
M12 reverse connector Communication cable
connection thread
10.5 11.5
(16)
SUP (1) OUT (2)
M12 x 1 Power cable
connection thread
(11)
10812
M3 x 0.5
Solenoid valve
Rc 1/8 Exhaust
port
EXH (3)
Rc 1/8 Exhaust
port
EXH (3)
EXH
Solenoid valve
EXH
19.5
11
2 x Rc 1/8, 1/4 SUP port, OUT port
Dimensions not shown are as on P.19.
RS-232C/
Solenoid valve
EXH
19.5
11
ITV100-RC
8.5
SUP (1) OUT (2)
40
Rc 1/8 Pressure gauge connection port
M12 x 1 Communication cable connection thread
M3 x 0.5
Solenoid valve
EXH
M12
x 1
Power cable connection thread
10 10
SUP (1) OUT (2)
(11)12
98
2 x Rc 1/8, 1/4 SUP port, OUT port
Dimensions not shown are as on P.19.
Rc 1/8 Pressure gauge connection port
With power cable connector
Note) Communication cable (other than RS-232C) should be obtained separately. (See P.9.)
40
ITV100-
(33)
2 x Rc 1/8, 1/4 SUP port, OUT port
Dimensions not shown are as on P.19.
CC DN
common dimensions
PR RC
Cable connector (4 wire)
Right angle type
Note) Do not attempt to rotate, as the cable connector does not turn.
40
Rc 1/8 Pressure gauge connection port
Cable connector (4 wire)
Straight type
20
50
40
52
84
100
Flat bracket
KT-ITV-F2
(Option)
Flat bracket
KT-ITV-F2
(Option)
36
(11)
SUP (1)
12
OUT (2)
93
12.5
19
13.5
EXH (3)
4 x ø7 Mounting hole
M5 x 0.8 Solenoid valve
EXH
Solenoid valve
EXH
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
SUP port, OUT port
2 x Rc 1/4, 3/8
Exhaust port
Rc 1/4
L-bracket
M12 x 1
Cable connection thread
45
2.3
36
L-bracket
KT-ITV-L2
(Option)
19
(33)
Cable connector (4 wire)
Straight type
Cable connector (4 wire)
Right angle type
Note) Do not attempt to rotate, as the cable connector does not turn.
2 x Rc 1/4, 3/8 SUP port, OUT port
(8.5)
7
R3.5
15
33
10
50
25
L-bracket
KT-ITV-L2
(Option)
Series ITV1000/2000/3000
ITV20
Flat bracket
Dimensions
19 13.5
8.5
Rc1/4 Exhaust
port
2 x Rc 1/4,3/8 SUP port, OUT port
EXH(3)
Solenoid valve
EXH
(11)120
36
12
10 10
M12 x 1 Power cabl
e
connection thread
M5 x 0.8
Solenoid valve
EXH
SUP(1)
OUT(2)
M12 x 1 Communication cable
connection thread
19 13.5
Rc1/4 Exhaust
port
2 x Rc 1/4,3/8 SUP port, OUT port
EXH(3)
Solenoid valve
EXH
9.5
(11)
(16)
(53)
13012
36
10.5 11.5
M12 x 1 Power cabl
e
connection thread
M5 x 0.8
Solenoid valve
EXH
SUP(1) OUT(2)
(11)13012
36
10 10
M5 x 0.8
Solenoid valve
EXH
SUP(1)
OUT(2)
19 13.5
8.5
EXH(3)
Solenoid valve
EXH
Rc1/4 Exhaust
port
2 x Rc 1/4,3/8 SUP port, OUT port
(11)120
36
10 10
M12 x 1 Power cabl
e
connection thread
M5 x 0.8
Solenoid valve
EXH
SUP(1) OUT(2)
M12 x 1 Communication cable
connection thread
12
19 13.5
8.5
Rc1/4 Exhaust
port
2 x Rc 1/4,3/8 SUP port, OUT port
EXH(3)
Solenoid valve
EXH
M12 x 1
BUS adapter
M12 x 1 Communication cable
connection thread
M12 x 1 Reverse connector
M12 x 1 Power cabl
e
connection thread
M12 reverse connector Communication cable
connection thread
CC-Link/ITV200-CC DeviceNet™/ITV200-DN
PROFIBUS DP/ITV200-PR RS-232C/ITV200-RC
With power cable connector
ITV200-
common dimensions
CC DN PR RC
Note) Communication cable (other than RS-232C) should be obtained separately. (See P.9.)
Dimensions not shown are as on P.21.
Dimensions not shown are as on P.21.
Dimensions not shown are as on P.21.
Dimensions not shown are as on P.21.
Note) Do not attempt to rotate, as the cable connector does not turn.
Cable connector (4 wire)
Straight type
(33)
Cable connector (4 wire)
Right angle type
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
21
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
CC-Link/ITV200-CC DeviceNet™/ITV200-DN
M12 x 1 Reverse connector
BUS adapter
8.5
Solenoid valve
EXH
19 13.5
2 x Rc 1/4,3/8 SUP port, OUT port
Dimensions not shown are as on P.21.
M12 x 1
M5 x 0.8
Solenoid valve
EXH
Rc1/4 Exhaust
port
EXH(3)
M12 x 1 Communication cable
connection thread
10 10
(53)
SUP(1)
M12 x 1 Power cabl
connection thread
36
OUT(2)
e
(11)13012
Solenoid valve
EXH
Dimensions not shown are as on P.21.
8.5
19 13.5
2 x Rc 1/4,3/8 SUP port, OUT port
M5 x 0.8
Solenoid valve
EXH
Rc1/4 Exhaust
port
EXH(3)
PROFIBUS DP/ITV200-PR RS-232C/ITV200-RC
9.5
M12 reverse connector Communication cable
connection thread
10.5 11.5
(16)
M12 x 1 Power cabl
connection thread
e
(11)
8.5
M12 x 1 Communication cable
connection thread
10 10
SUP(1) OUT(2)
36
M12 x 1 Communication cable
connection thread
10 10
M12 x 1 Power cabl
connection thread
M12 x 1 Power cabl
connection thread
e
(11)120
12
e
(11)120
M5 x 0.8
Solenoid valve
EXH
Rc1/4 Exhaust
port
Solenoid valve
19 13.5
EXH
2 x Rc 1/4,3/8 SUP port, OUT port
Dimensions not shown are as on P.21.
SUP(1) OUT(2)
EXH(3)
With power cable connector
Note) Communication cable (other than RS-232C) should be obtained separately. (See P.9.)
36
ITV200-
(33)
13012
Solenoid valve
EXH
Dimensions not shown are as on P.21.
CC DN
common dimensions
PR RC
Cable connector (4 wire)
Right angle type
19 13.5
2 x Rc 1/4,3/8 SUP port, OUT port
Cable connector (4 wire)
Straight type
M5 x 0.8
Solenoid valve
EXH
Rc1/4 Exhaust
port
EXH(3)
SUP(1)
OUT(2)
36
12
Note) Do not attempt to rotate, as the cable connector does not turn.
22
30
50
66
40
52
84
100
36
Flat bracket
KT-ITV-F2
(Option)
Flat bracket
KT-ITV-F2
(Option)
(11)
12
114
SUP (1)
OUT (2)
Rc 1/4
Solenoid valve
EXH
12.5
25
22 8
35.7
EXH (3)
Mounting hole
4 x ø7
Cable connector (4 wire)
Right angle type
Cable connection thread
M12
x 1
Rc 1/2 Exhaust port
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
Cable connector (4 wire)
Straight type
Note) Do not attempt to rotate, as the cable connector does not turn.
Pressure gauge connection por
t
L-bracket
(33)
L-bracket
KT-ITV-L2
(Option)
22
25
36
45
2.3
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
30
(8.5)
7
R3.5
15
33
10
50
25
L-bracket
KT-ITV-L2
(Option)
Series ITV1000/2000/3000
ITV30
Flat bracket
Dimensions
M5 x 0.8 Solenoid valve EXH
(11)151
10
10
M12 x 1 Power cabl
e
connection thread
12
36
Rc 1/4 Pressure gauge
connection port
SUP (1)
OUT (2)
M12 x 1 Communication cable connection thread
8.5
22
EXH (3)
Rc 1/2 Exhaust
port
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
8
(11)141
10 10
M12 x
1
Power cable connection thread
12
36
Rc 1/4 Pressure gauge
connection port
SUP (1) OUT (2)
22 8
M12 x 1 Communication cable
connection thread
8.5
EXH (3)
Rc 1/2 Exhaust
port
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
(11)
(16) (53)
151
10.5 11.5
M12 x
1
Power cable connection thread
12
36
Rc 1/4 Pressure gauge
connection port
SUP (1)
OUT (2)
M12 reverse connector Communication cable connection thread
9.5
EXH (3)
Rc 1/2 Exhaust
port
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
22 8
(11)141
10 10
M12 x
1
Power cable connection thread
36
12
Rc 1/4 Pressure gauge
connection port
SUP (1) OUT (2)
M12 x 1 Communication cable
connection thread
8.5
EXH (3)
Rc 1/2 Exhaust
port
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
22 8
M12 x 1
M12 x 1 Reverse connector
35.7
Solenoid valve
EXH
35.7
Solenoid valve
EXH
35.7
Solenoid valve
EXH
35.7
Solenoid valve
EXH
BUS adapter
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
4 x M5 x 0.8 thread depth 6 mm through Mounting hole
PROFIBUS DP/
ITV30-PR
RS-232C/
ITV30-RC
With power cable connector
ITV30-
common dimensions
CC DN
PR
RC
Dimensions not shown are as on P.23.
Dimensions not shown are as on P.23.
Dimensions not shown are as on P.23.
Dimensions not shown are as on P.23.
Note) Do not attempt to rotate, as the cable connector does not turn.
CC-Link/ITV30-CC DeviceNet™/ITV30-DN
Cable connector (4 wire)
Straight type
Cable connector (4 wire)
Right angle type
(33)
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
23
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C)
CC-Link/ITV30-CC DeviceNet™/ITV30-DN
M12 x 1 Reverse connector
BUS adapter
M12 x 1
8.5
M12 x 1 Communication cable connection thread
10
10
M12 x 1 Power cabl
connection thread
e
(11)151
M12 x 1 Communication cable
connection thread
8.5
M12 x 1 Power cable
connection thread
10 10
(11)141
Solenoid valve
EXH
Rc 1/2
35.7
8
22
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
Dimensions not shown are as on P.23.
PROFIBUS DP/
9.5
Solenoid valve
EXH
35.7
22 8
Exhaust port
EXH (3)
ITV30-PR
Rc 1/2 Exhaust
port
EXH (3)
SUP (1)
36
Rc 1/4 Pressure gauge
connection port
M12 reverse connector Communication cable connection thread
SUP (1)
10.5 11.5
(16) (53)
OUT (2)
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
M12 x Power cable
connection thread
OUT (2)
12
1
(11)
151
Solenoid valve
EXH
Rc 1/2
35.7
22 8
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
Dimensions not shown are as on P.23.
RS-232C/
Solenoid valve
EXH
35.7
22 8
ITV30-RC
M12 x 1 Communication cable
connection thread
8.5
Exhaust port
EXH (3)
Rc 1/2 Exhaust
port
EXH (3)
SUP (1) OUT (2)
36
Rc 1/4 Pressure gauge
connection port
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
M12 x 1 Power cable connection
thread
10 10
SUP (1) OUT (2)
12
(11)141
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
Dimensions not shown are as on P.23.
With power cable connector
CC
ITV30-
DN PR RC
common dimensions
36
Rc 1/4 Pressure gauge
connection port
(33)
12
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
Cable connector (4 wire)
Right angle type
36
2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port
Dimensions not shown are as on P.23.
Cable connector (4 wire)
Straight type
Note) Do not attempt to rotate, as the cable connector does not turn.
Rc 1/4 Pressure gauge
connection port
4 x M5 x 0.8 thread depth 6 mm through
Mounting hole
12
24
Parallel input type with digital 10 bit.
Digital Input Type
2
ITV20
X157
ITV30
4
ITV10
X1574
4
0
0
S
N
S
N
S
N
0 X157
0
0
0
Able to control 16-point-pressure by 4 bit switching input
16 Points Preset Input Type
1
ITV20
16 points preset type
X156
ITV30
4
ITV10 X156
4
2 3
2 3
2 3
4
0
0
0
X156
In compliance with the input, inverse proportional pressure is displayed.
Reverse Type
3
ITV20 X321
ITV10 X321
ITV30 X321
High Pressure Type (SUP 1.2 MPa, OUT 1.0 MPa)
4
ITV20 X322
ITV10 X322
ITV30 X322
0
0 100
Output pressure
(MPa)
This range is outside of the control (output).
0.005 MPa
Rated
pressure
5
5
5
Set Pressure Range 1 to 100 kPa
5
ITV20 X323
ITV10 X323
1
1
0
0
0
Digital input type
Note 1) in part number is the same model no. for the standard products. Note 2) Right angle type cable connectors cannot be selected.
Note 1)
in part number is the same model no. for the standard products.
Note 2) Except for preset input type.
Input/output characteristics chart
Input signal (%F.S.)
Reverse type
High pressure type (SUP 1.2 MPa, OUT 1.0 MPa)
Set pressure range 1 to 100 kPa
Made to Order Specifications 1
Series ITV1000/2000/3000
Contact SMC regarding detailed dimensions, specifications and delivery times.
Note 1) in part number is the same model no. for
the standard products.
Note 2) Monitor output is switch output type only.This
cannot be selected for types without a moni
-
tor output or with analogue output.
Note 3) Values can be adjusted starting from the mini-
mum output pressure display units.
MPa
0.01
kgf/cm
2
0.01
bar
0.01
psi
0.1
kPa
1
130 psi type: 1 psi
Made to
Orde
r
2 through 8 station manifold.
How to Order Manifolds
IITV20 02 5
Manifold Specifications
(Except Series ITV3000)
7
How to Order Manifold Assemblies
Example
1
2
3
Stations
Pressure response with no load is approx. 0.1 sec.
High-Speed Response Time Type
6
ITV X1542 0 1 0 S0 1 2
Pressure display unit
2 3 4 5
MPa
kgf/cm
2
bar psi
kPa
Model
1 2
1000 type 2000 type
Pressure range
1 3 5
0.1 MPa
0.5 MPa
0.9 MPa
Power supply
voltage
0 1
24 VDC
12 to 15 VDC
Input signal
0 1 2 3
Current 4 to 20 mA (Sink type) Current 0 to 20 mA (Sink type)
Voltage 0 to 5 VDC
Voltage 0 to 10 VDC
1
Analogue output 1 to 5 VDC
Monitor output
Thread type
N
T F
Rc
NPT
NPTF
G
Port size
1 2 3
1/8 (1000 type)
1/4 (1000, 2000 type)
3/8 (2000 type)
Bracket
B C
Without bracket
Flat bracket
L-bracket
Cable connector type
S L
N
Straight type 3 m
Right angle type 3
m
Without cable connector
ITV1000, 2000
02 03
OUT port size
Connection thread type
1/4 3/8
N F
PT
NPT
PF
2
8
Valve stations
2 stations
8 stations
Note) Refer to the table below for possible mixed combination.
Model
ITV101
ITV103
ITV105
ITV201
ITV203
ITV205
ITV101ITV103ITV105ITV201ITV203ITV205
IITV20-02-3 ……………………
ITV1030-311S-X26 …………
P398020-13 ………………… ITV2050-212S-X26 …………
1 set (3 station manifold base part no.) 1 set (Electro-pneumatic regulator part no.)
Note 2)
1 set (Blanking plate assembly part no.) 1 set (Electro-pneumatic regulator part no.)
Note 2)
The is the symbol for mounting. Add the symbol at the beginning of part numbers for electro-pneumatic regulators, etc. to be mounted on the base.
Note 1) Electro-pneumatic regulators are counted starting from station 1 on
the left side with the OUT ports in front.
Note
2)
The port size for mounted electro-pneumatic regulators is Rc 1/8 (ITV1000), Rc 1/4 (ITV2000) only.
Note 3) When there
is a large number of stations, use piping with the largest
possible inside diameter for the supply side, such as steel piping.
Note
4)
The use of the straight type cable connector is recommended. To mount right angle
type, be certain to check that no possible
interference occurs.
Note
5)
When mounting a blanking plate and the regulator with different pressure set, please inform SMC of the order of a manifold station beside a purchase order.
ITV1030-311S-X26
Electro-pneumatic regulator
P398020-13
Blanking plate assembly
ITV2050-212S-X26
Electro-pneumatic regulator
IITV20-02-3
Manifold base (3 stations)
Note 1)
Only for overseas sales (SI units are to be used inside Japan).
High-speed response time specifications
Made to Order Specifications 2
Series ITV1000/2000/3000
Contact SMC regarding detailed dimensions, specifications and delivery times.
Made to
Order
25
Series ITV1000/2000/3000
Made to Order Specifications 2
Contact SMC regarding detailed dimensions, specifications and delivery times.
6
High-Speed Response Time Type
Pressure response with no load is approx. 0.1 sec.
ITV X1542 0 1 0 S0 1 2
Made to
Order
Model
1 2
1000 type 2000 type
Pressure range
Power supply
voltage
24 VDC
0
12 to 15 VDC
1
0 1 2 3
7
Manifold Specifications
2 through 8 station manifold.
How to Order Manifolds
0.1 MPa
1
0.5 MPa
3
0.9 MPa
5
Input signal
Current 4 to 20 mA (Sink type) Current 0 to 20 mA (Sink type)
Voltage 0 to 5 VDC
Voltage 0 to 10 VDC
Monitor output
Analogue output 1 to 5 VDC
1
Thread type
N
T F
Rc
NPT
NPTF
G
(Except Series ITV3000)
Port size
1 2 3
Pressure display unit
2 3 4 5
Only for overseas sales (SI units are to be used inside Japan).
MPa
kgf/cm
bar psi
kPa
2
Cable connector type
S L N
Straight type 3 m
Right angle type 3 m
Without cable connector
Bracket
Without bracket
1/8 (1000 type)
1/4 (1000, 2000 type)
B C
Flat bracket
L-bracket
3/8 (2000 type)
How to Order Manifold Assemblies
High-speed response time specifications
IITV20 02 5
Valve stations
2
8
ITV1000, 2000
IITV20-02-3 ……………………
ITV1030-311S-X26 …………
P398020-13 …………………ITV2050-212S-X26 …………
The is the symbol for mounting. Add the symbol at the beginning of part numbers for electro-pneumatic regulators, etc. to be mounted on the base.
Note) Refer to the table below for possible mixed combination.
Model
ITV101 ITV103 ITV105 ITV201 ITV203 ITV205
ITV101ITV103ITV105ITV201ITV203ITV205
     
1 set (3 station manifold base part no.) 1 set (Electro-pneumatic regulator part no.) 1 set (Blanking plate assembly part no.) 1 set (Electro-pneumatic regulator part no.)
OUT port size
02 03
1/4 3/8
Connection thread type
PT
N
NPT
F
PF
2 stations
8 stations
Note 2)
Note 2)
Example
Electro-pneumatic regulator
ITV1030-311S-X26
Manifold base (3 stations)
IITV20-02-3
Note 1) Electro-pneumatic regulators are counted starting from station 1 on
the left side with the OUT ports in front.
2)
The port size for mounted electro-pneumatic regulators is Rc 1/8
Note
(ITV1000), Rc 1/4 (ITV2000) only.
Note 3) When there
possible inside diameter for the supply side, such as steel piping.
4)
The use of the straight type cable connector is recommended. To
Note
mount right angle interference occurs.
5)
When mounting a blanking plate and the regulator with different
Note
pressure set, please inform SMC of the order of a manifold station beside a purchase order.
1
is a large number of stations, use piping with the largest
Blanking plate assembly
P398020-13
Electro-pneumatic regulator
ITV2050-212S-X26
2
3
Stations
type, be certain to check that no possible
Note 1)
26
Safety Instructions
Limited warranty and Disclaimer/Compliance Requirements
The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”. Read and accept them before using the product.
1. The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Caution
Limited warranty and Disclaimer
1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.
Note 2)
Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.
2.
For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.
3.
Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified
catalogue for the particular products.
Note 2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.
Compliance Requirements
1.
The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or
any other weapon is strictly prohibited.
2.
The exports of SMC products or technology from one country to another are governed by the relevant security laws
and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.
Back page 2
Air Supply
Caution
Handling
Caution
Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed care­fully, as incorrect wiring can cause damage.
Further, use DC power with sufficient capacity and a low ripple.
Caution
Specific Product Precautions 1
Series ITV0000/1000/2000/3000
Wiring
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
A right angle type cable is also available. The entry direction for the right angle type con
­nector is to downwards (SUP port side). Never turn the connector as it is not designed to turn. Using force to turn the connector will damage the connector cou
­pling.
3: (Blue)
1: (Brown)
2: (White)
4: (Black)
Wiring Diagrams
Current signal type
Analogue output, voltage type
Vs
A
Voltage signal type
Monitor output voltage
Vs
Vin
Vs: Power Supply 24 V DC ±10% 12 to 15 V DC A : Input signals 4 to 20 mA DC 0 to 20 mA DC
Vs : Power Supply 24 V DC ±10% 12 to 15 V DC Vin: Input signals 0 to 5 V DC 0 to 10 V DC
1 Brown Power
2 White Signal
3
Blue
COM
4
Black
Monitor
Terminal No. Lead wire colour Wiring
Monitor output wiring diagram
Body
Note)
Brown
Blue
White
Black
Series ITV0000/009Precautions
1. Do not use a lubricator on the supply side of this product, as this can cause malfunction. When lubrication of the terminal equipment is necessary, connect a lubricator on the output side of this equipment.
2. If electric power is shut off while pressure is being applied, pressure will be retained on the output side.
However, this output pressure is held only temporarily and is not gua­ranteed.
If exhausting of this pressure is desired, shut off the power after reducing the set pressure, and discharge the air using a residual pressure exhaust valve, etc.
3. If power to this product is cut off due to a power failure, etc. when
it is in a controlled state, output pressure will be retai­ned temporarily. Handle carefully when operating with output pressure released to the atmosphere, as air will continue to flow out
.
4. If supply pressure to this product is interrupted while the power is
still on, the internal solenoid valve will continue to operate
and a humming noise may be generated.
Since the life of the product may be shortened, shut off the power supply also when supply pressure is shut off.
5. This product is adjusted for each specification at the time of shipment from
the factory. Avoid careless disassembly or remo-
val of parts, as this can lead to malfunction.
6. The optional cable connector is a 4 wire type. When the moni­tor output (analogue output or switch output) is not being used, keep it from touching the other wires as this can cause malfunction.
7. Please note that the right angle cable does not rotate and is li­mited to only one entry direction.
8. Take the following steps to avoid malfunction due to noise.
1) Remove power supply noise during operation by installing a line fil-
ter, etc. in the AC power line.
2) For avoiding the influence of noise or static electricity, install this
product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc.
3) Be sure to implement protective measures against load surge for in
-
duction loads (solenoid valves, relays, etc.).
9. The product characteristics are confined to the static state. The pressure may not reach the set pressure and the life of the product may extremely be shortened with buzzing of the solenoid valve when air is consumed on the output side, es­pecially when it is used with a system which has a large amount of leakage.
10.
For details on the handling of this product, refer to the
instruction manual which is included with the product
.
11. In locations where the body is exposed to water, dust, etc., there is a possibility that moisture or dust could enter the body through the breathing hole.
Mount a fitting and tube (M-3AU-3 fitting and TIU01m-mm tube recommended) onto the breat­hing hole and run the tube to a location not expo­sed to moisture or dust, etc.
12. If this product will be used in a sealed environment, such as in­side an inspection box, a ventilation fan should be installed to ensure adequate ventilation as this product can generate heat in some operating conditions.
When the power is turned on, a noise may be generated as a means of checking the operating condition of the solenoid valve. This noise is normal and does not indicate a fault.
2
Breathing hole
M3 x 0.
5
1. Install an air filter near this product on the supply side. Select a filtration degree of 5 µm or less.
2. Compressed air containing large amounts of drainage can cause malfunction of this product and other pneu­matic equipment. As a countermeasure, install an af­tercooler, air dryer or Drain Catch, etc.
3. If large amounts of carbon dust are generated by the compressor, it can accumulate inside this product and cause malfunction.
For details on the above compressed air quality, refer to SMC's "Air Preparation Systems".
Note)
Brown
Blue
White
Black
Brown
Blue
White
Black
Brown
Blue
White
Black
Specific Product Precautions 2
1.
Screw piping together with the recommended proper torque while holding the side that has female threads.
Looseness or faulty sealing will occur if tightening torque is in- sufficient, while thread damage will result if the torque is ex- cessive. Furthermore, if the side with the female threads is not held while tightening, excessive force will be applied directly to the piping brackets, etc. causing damage or other problems.
2. Do not allow twisting or bending moment to be ap- plied other than the weight of the equipment itself.
Provide separate support for external piping, as damage may otherwise occur.
3. Since excessive moment loads and the propagation of vibrations, etc. can easily result from inflexible piping made of materials such as steel, avoid these problems by using flexible tubing for intermediate connections.
Piping
Warning
1. Preparation before piping
Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and ot- her debris from inside the pipe.
2. Wrapping of pipe tape
When screwing together pipes and fittings, etc., be sure that chips from the pipe threads and sealing material do not get in- side the piping.
Also, when pipe tape is used, leave 1.5 to 2 thread ridges ex- posed at the end of the threads.
Wrapping direction
Pipe tape
Expose approx.
2
threads
Caution
1. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, or where there will be contact with them.
2. Do not operate in locations where vibration or im- pact occurs.
Operating Environment
1. Employ suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc.
2. Consult with
SMC when used in power plants, or if
instrumentation related.
Air Supply
Warning
Warning
Caution
Recommended proper torque: N.m
Connection thread
Torque
1/8
1/4 3/8 1/2
7 to 9 12 to 14 22 to 24 28 to 30
REGULATOR
ITV2000
Series ITV0000/1000/2000/3000
Caution
REGULATOR
ITV2000
Series ITV1000/2000/3000/209Precautions
1. In locations where the body is exposed to water, steam, dust, etc., there is a possibility that moisture or dust could enter the body through the EXH (sole- noid) ports, thereby causing problems.
2. To overcome this, simply install tubing to each port, using the fittings, and extend the tubing so that the other end is at a location where no water splash, etc. occurs. Make sure not to bend, or block the I.D. of the tubing as this
will have a detrimental effect
on the pressure control.
3.
Do not operate in locations where vibration or im- pact occurs.
4. In locations which receive direct sunlight, provide a protective cover, etc.
5.
In locations near heat sources, block off any radia- ted heat.
6. In locations where there is contact with spatter from water, oil or solder etc., implement suitable protecti- ve measures.
1. Install an air filter near this product on the supply side. Select a filtration degree of 5
µm or less.
2. Compressed air containing large amounts of drai- nage can cause malfunction of this product and ot- her pneumatic equipment. As a countermeasure, install an aftercooler, air dryer or Drain Catch, etc.
3. If large amounts of carbon dust are generated by the compressor,
it can accumulate inside this pro- duct and cause malfunction. For details on the abo- ve compressed air quality, refer to SMC's "Air Pre- paration Systems".
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 3
Specific Product Precautions 2
1.
Screw piping together with the recommended proper torque while holding the side that has female threads.
Looseness or faulty sealing will occur if tightening torque is in­sufficient, while thread damage will result if the torque is ex­cessive. Furthermore, if the side with the female threads is not held while tightening, excessive force will be applied directly to the piping brackets, etc. causing damage or other problems.
2. Do not allow twisting or bending moment to be ap­plied other than the weight of the equipment itself.
Provide separate support for external piping, as damage may otherwise occur.
3. Since excessive moment loads and the propagation of vibrations, etc. can easily result from inflexible piping made of materials such as steel, avoid these problems by using flexible tubing for intermediate connections.
Piping
Warning
1. Preparation before piping
Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and ot­her debris from inside the pipe.
2. Wrapping of pipe tape
When screwing together pipes and fittings, etc., be sure that chips from the pipe threads and sealing material do not get in­side the piping.
Also, when pipe tape is used, leave 1.5 to 2 thread ridges ex­posed at the end of the threads.
Wrapping direction
Pipe tape
Expose approx.
2
threads
Caution
1. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, or where there will be contact with them.
2. Do not operate in locations where vibration or im­pact occurs.
Operating Environment
1. Employ suitable protective measures in locations
where there is contact with water droplets, oil or welding spatter, etc.
2. Consult with
SMC when used in power plants, or if
instrumentation related.
Air Supply
Warning
Warning
Caution
Recommended proper torque: N.m
Connection thread
Torque
1/8
1/4 3/8 1/2
7 to 9 12 to 14 22 to 24 28 to 30
REGULATOR
ITV2000
Series ITV0000/1000/2000/3000
Caution
REGULATOR
ITV2000
Series ITV1000/2000/3000/209Precautions
1. In locations where the body is exposed to water, steam, dust, etc., there is a possibility that moisture or dust could enter the body through the EXH (sole­noid) ports, thereby causing problems.
2. To overcome this, simply install tubing to each port, using the fittings, and extend the tubing so that the other end is at a location where no water splash, etc. occurs. Make sure not to bend, or block the I.D. of the tubing as this
will have a detrimental effect
on the pressure control.
3.
Do not operate in locations where vibration or im-
pact occurs.
4. In locations which receive direct sunlight, provide a protective cover, etc.
5.
In locations near heat sources, block off any radia-
ted heat.
6. In locations where there is contact with spatter from water, oil or solder etc., implement suitable protecti­ve measures.
1. Install an air filter near this product on the supply side. Select a filtration degree of 5
µm or less.
2. Compressed air containing large amounts of drai­nage can cause malfunction of this product and ot­her pneumatic equipment. As a countermeasure, install an aftercooler, air dryer or Drain Catch, etc.
3. If large amounts of carbon dust are generated by the compressor,
it can accumulate inside this pro­duct and cause malfunction. For details on the abo­ve compressed air quality, refer to SMC's "Air Pre­paration Systems".
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 4
Specific Product Precautions 3
Series ITV0000/1000/2000/3000
1. Do not use a lubricator on the supply side of this product, as this can cause malfunction. When lubri­cation of terminal equipment is necessary, connect a lubricator on the output side of this equipment.
2. If electric power is shut off while pressure is being applied, pressure will be retained on the output si­de. However, this output pressure is held only tempora­rily and is not guaranteed. If exhausting of this pressure is desired, shut off the power after redu­cing the set pressure, and discharge the air using a residual pressure exhaust valve, etc.
3. If power to this product is cut off due to a power fai­lure, etc. when it is in a controlled state, output pressure will be retained temporarily. Handle care­fully when operating with output pressure released to the atmosphere, as air will continue to flow out.
4. If supply pressure to this product is interrupted whi­le the power is still on, the internal solenoid valve will continue to operate and a humming noise may be generated. Since the life of the product may be shortened, shut off the power supply also when supply pressure is shut off.
5. In this product, the output side pressure cannot be completely relieved within the range of 0.005 MPa or less. If it is desired to reduce the pressure comple­tely to 0 MPa, install a 3 way valve or other device on the output side to exhaust the pressure.
6. This product is adjusted for each specification at the time of shipment from the factory. Avoid care­less disassembly or removal of parts, as this can lead to malfunction.
7. The optional cable connector is a 4 wire type. When the monitor output (analogue output or switch out­put) is not being used, keep it from touching the ot­her wires as this can cause malfunction.
8. Please note that the right angle cable does not rota­te and is limited to only one entry direction.
9. Take the following steps to avoid malfunction due to noise.
1) Remove power supply noise during operation by installing a
line filter, etc. in the AC power line.
2) For avoiding the influence of noise or static electricity, install
this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc.
3) Be sure to implement protective measures against load sur-
ge for induction loads (solenoid valves, relays, etc.).
Handling
Caution
10. Due to the large volume of the output side, a loud exhaust noise will be produced when being used for the purpose of a relief function. Therefore, install a silencer
(SMC Series AN200 or AN400) on the ex-
haust port
(EXH port). The port sizes are Rc 1/8, Rc
1/4 and Rc 1/2.
11. Specifications on page 10 is in case of static envi­ronment. Pressure may fluctuate when air is consu­med at the output side.
12. For details on the handling of this product, refer to the instruction manual which is included with the product.
Handling
Caution
Series ITV1000/2000/3000/209Precautions
Design and Selection
Caution
1. The direct-current power supply to combine should be UL authorized power supply.
(1) Limited voltage current circuit in accordance with UL 508.
A circuit in which power is supplied by the secondary coil of a transformer that meets the following conditions.
• Maximum voltage (with no load): 30 Vrms (42.4 V peak) or less
• Maximum current: (1) 8 A or less (including when short circuited) (2) limited by circuit protector (such as fuse) with the follow-
ing ratings.
(2) A circuit using max. 30 Vrms or less (42.4 V peak), which is
powered by UL1310 or UL1585 compatible Class-2 power supply.
2. Operate these products only within the specified voltage.
Using voltages beyond the specified levels could cause faults or malfunctions.
3.
Use 0 V as the baseline for the power supplied to the unit for output, control and input.
0 V
Output power
Control/input power
+24
V
+24
V
0 V
Output power
Control/input power
–24
V
+24
V
No load voltage (V peak)
0 to 20 [V]
Above 20 to 30 [V]
Max. current rating
5.0
100
Peak voltage
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Specific Product Precautions 4
Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple.
Caution
Brown
Blue
White
Black
Note)
Body
Wiring diagram
Current signal type
Analogue output: Voltage type
Switch output: NPN type
Switch output: PNP type
Vs
Vs
A
Voltage signal type
Monitor output voltage
Blue
Brown
White
Black
Vs
Vin
Vs : Power supply 24 VDC
12 to 15 VDC
A : Input signal 4 to 2
0 mADC
0 to 2
0 mADC
Vs : Power supply 24 VDC
12 to 15 VDC
Vs : Power supply
24 VDC
12 to 15 VDC
Vin
: Input signal
0 to 5 VDC 0 to 10 VDC
RESET
Preset input type
S1 S2
Preset pressure
OFF OFF
P1
ON
OFF
P2
OFF
ON
P3
ON ON P4
S2
S1
Monitor output wiring diagram
Monitor output voltage
Series ITV0000/1000/2000/3000
DeviceNet Power
2
2
3
1
4
1
4
5
3
Pin No.
1 2 3 4 5
CC-Link
SLD
DB
DG
DA
NC
PROFIBUS DP
NC
RxD/TxD-N
NC
RxD/TxD-P
NC
RS-232C
NC TxD RxD
GND
NC
DeviceNet
DRAIN
V+
V– CAN_H CAN_L
Pin No.
1 2 3 4
CC-Link
Vcc
FG
GND
NC
PROFIBUS DP
Vcc NC
GND
NC
RS-232C
Vcc NC
GND
FG
DeviceNet
Vcc
No connection
GND
No connection
Power supply connector
Communication connector
Power supply connector
DeviceNet, RS-232C
PROFIBUS DP
CC-Link
Trademark Information
DeviceNet™ is a trademark of ODVA.
Communication connector
Power supply connector
Power supply connector
2
1
3
5
4
3
2
1
4
4
4
4
1
1
1
5
2
2
2
3
3
3
Communication connector
3: (Blue) 1: (Brown)
2: (White)
4: (Black)
1 2 3 4
Current Signal Type Voltage Signal Type
Brown
White
Blue
Black
Power supply Input signal GND (COMMON) Monitor output
1 2 3 4
Brown
White
Blue
Black
Power supply Input signal 1 GND (COMMON) Input signal 2
Preset Input Type
Brown
Blue
White
Black
Brown
Blue
White
Black
Brown
Blue
White
Black
One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.
When 30 mADC or more is applied, detecting device for overcu-
rrentstarts activating and then emits an error signal. (Error number “5”)
Blue
Brown
White
Black
Load
Blue
Brown
White
Black
Load
Blue
Brown
White
Black
IN/OUT communication connector
The cable is also available in a right-angle type. A right-angle type connector is attached facing left (towards the SUP port). On communication models, the connector faces backwards (to
- wards the EXH port). Do not attempt to rotate, as the connector does not turn.
Note)
Series ITV1000/2000/3000/209Precautions
Wiring
For safety reasons, it is recommended that one of the preset pressures
be set to 0 MPa.
Preset pressures are set based on the minimum unit for output display.
· Note that this is 1 psi for 130-psi types.
MPa
0.01
kgf/cm
2
0.01
bar
0.01
psi
0.1
kPa
1
Analogue output: Current type (Sink type)
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 5
Specific Product Precautions 4
Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple.
Caution
Brown
Blue White Black
Note)
Body
Wiring diagram
Current signal type
Analogue output: Voltage type
Switch output: NPN type
Switch output: PNP type
Vs
Vs
A
Voltage signal type
Monitor output voltage
Blue
Brown
White
Black
Vs
Vin
Vs : Power supply 24 VDC
12 to 15 VDC
A : Input signal 4 to 2
0 mADC
0 to 2
0 mADC
Vs : Power supply 24 VDC
12 to 15 VDC
Vs : Power supply
24 VDC
12 to 15 VDC
Vin
: Input signal
0 to 5 VDC 0 to 10 VDC
RESET
Preset input type
S1 S2
Preset pressure
OFF OFF
P1
ON
OFF
P2
OFF
ON
P3
ON ON
P4
S2
S1
Monitor output wiring diagram
Monitor output voltage
Series ITV0000/1000/2000/3000
DeviceNet Power
2
2
3
1
4
1
4
5
3
Pin No.
1 2 3 4 5
CC-Link
SLD
DB DG DA NC
PROFIBUS DP
NC
RxD/TxD-N
NC
RxD/TxD-P
NC
RS-232C
NC
TxD
RxD
GND
NC
DeviceNet™
DRAIN
V+ V–
CAN_H
CAN_L
Pin No.
1 2 3 4
CC-Link
Vcc
FG
GND
NC
PROFIBUS DP
Vcc
NC
GND
NC
RS-232C
Vcc NC
GND
FG
DeviceNet™
Vcc
No connection
GND
No connection
Power supply connector
Communication connector
Power supply connector
DeviceNet, RS-232C
PROFIBUS DP
CC-Link
Trademark Information
DeviceNet™ is a trademark of ODVA.
Communication connector
Power supply connector
Power supply connector
2
1
3
5
4
3
2
1
4
4
4
4
1
1
1
5
2
2
2
3
3
3
Communication connector
3: (Blue) 1: (Brown)
2: (White)
4: (Black)
1 2 3 4
Current Signal Type Voltage Signal Type
Brown
White
Blue
Black
Power supply Input signal GND (COMMON) Monitor output
1 2 3 4
Brown
White
Blue
Black
Power supply Input signal 1 GND (COMMON) Input signal 2
Preset Input Type
Brown
Blue
White
Black
Brown
Blue
White
Black
Brown
Blue
White
Black
One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.
When 30 mADC or more is applied, detecting device for overcu-
rrentstarts activating and then emits an error signal. (Error number “5”)
Blue
Brown
White
Black
Load
Blue
Brown
White
Black
Load
Blue
Brown
White
Black
IN/OUT communication connector
The cable is also available in a right-angle type. A right-angle type connector is attached facing left (towards the SUP port). On communication models, the connector faces backwards (to
­wards the EXH port). Do not attempt to rotate, as the connector does not turn.
Note)
Series ITV1000/2000/3000/209Precautions
Wiring
For safety reasons, it is recommended that one of the preset pressures
be set to 0 MPa.
Preset pressures are set based on the minimum unit for output display.
· Note that this is 1 psi for 130-psi types.
MPa
0.01
kgf/cm
2
0.01
bar
0.01
psi
0.1
kPa
1
Analogue output: Current type (Sink type)
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 6
Specific Product Precautions 5
Regulating pressure range, by unit of standard measured pressure
Unit
MPa
kgf/cm
2
bar
psi
kPa
Set Pressure Range
CE Mark
The regulating pressure range, by unit of standard measured pressure, is shown in the table below.
In case that a CE marked ITV (including a special product) is used with a cable which is purchased separately, mount a ferrite core to the cable if it is necessary according to the table below.
ITV01
ITV03
Regulating pressure range
ITV05
0.005 to 0.1
0.05 to 1
0.05 to 1
0.7 to 15
5 to 100
0.005 to 0.5
0.05 to 5
0.05 to 5
0.7 to 70
5 to 500
Model Ferrite core
Recommended power cable part No.
ITV0000--Q
ITV0000 series
Not necessary M8-4DSX3MG4
(Straight type)
ELWIKA-KV4408 PVC025 2M
(Right angle type)
Model Ferrite core
Recommended power cable part No.
ITV--Q
ITV1000/2000/3000 series
Necessary
ITV-CC-Q
Not necessary
ITV-DN-Q
Necessary
(Ferrite core is
attached to the body)
ITV-PR-Q
ITV-RC-Q
Necessary
(Ferrite core is
attached to the body)
P398010-12 (Straight type)
(With ferrite core)
P398010-13 (Right angle
type) (With ferrite core)
P398020-500-3
(Straight type)
P398020-501-3
(Right angle type)
P398020-504-3
(Straight type)
P398020-505-3
(Right angle type)
P398020-500-3
(Straight type)
P398020-501-3
(Right angle type)
0.005 to 0.9
0.05 to 9
0.05 to 9
0.7 to 130
5 to 900
Series ITV0000/1000/2000/3000
ITV209
–1.3 to –80
Note) Length of the recommended cable is 3m (however, ELWIKA­KV4408 PVC025 2M is 2 metres. Consult SMC for length of other cables)
Series ITV1000/2000/3000/209Precautions
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Specific Product Precautions 6
Series ITV0000/1000/2000/3000
Handling
1. Connect the vacuum pump to the port, which is la- beled “VAC”.
2. Pressure adjustment changes from “atmospheric pressure to vacuum pressure” when the input sig- nal is increased, and from “vacuum pressure to at- mospheric pressure” when the input signal is de- creased.
3. When adjusting the vacuum pressure, be careful not to block the atmospheric pressure inlet port labeled “ATM”.
4. Since this product is designed exclusively for use with negative pressure, be careful not to apply posi- tive pressure in error.
5. In cases where the vacuum pump being used has a relatively small capacity, or the piping has a small inside diameter, etc., large variations in the set pressure (the range of pressure variation when changing from no flow to flow state) may appear. In this situation, the vacuum pump or the piping, etc. should be changed. In cases where it is not practi- cal to change the vacuum pump, install a capacity tank (volume depending on the operating condi- tions) on the VAC side.
6. The vacuum pressure response time after a change in the input signal is influenced by the internal volu- me on the setting side (including piping). Since the capacity of the vacuum pump also influences the response time, give careful consideration to these points before operation.
7. If the electric power is shut off when in a control state, the pressure on the setting side will go into a holding condition. However, this setting side pres- sure will be held only temporarily and is not guaran- teed. In addition, when atmospheric pressure is de- sired, shut off the power after reducing the set pres- sure, and then introduce atmospheric pressure by using a vacuum release valve, etc.
8. If the power for this product is cut off by a power failure, etc. when it is in a controlled state, the set- ting side pressure will be held temporarily. Further, if operated without sealing the setting side so that atmospheric air is sucked in, handle with care as air will continue to be sucked in.
9.
If the VAC side pressure to this product is interrup- ted while the power is still on, the internal solenoid valve
will continue to operate and may cause a humming noise. Since this may shorten the life of the product, be sure to shut off the power when the VAC side pressure is shut off.
10.
The setting side pressure cannot be completely re- leased from this product in the range below –1.3 kPa. In cases where the pressure needs to be redu- ced completely to 0 kPa, install a 3 port valve, etc. on the setting side to discharge the residual pressu- re.
11.
This product is adjusted for each specification at the factory before shipment. Avoid careless disas
-
sembly or removal of parts, as this can cause failu
-
re.
12. The optional cable connector is a 4-wire type. When the monitor output (analog output, switch output) is not being used, keep
it from touching the other wi-
res, as this can cause malfunction.
13.
Use caution that the right angle cable does not rota-
te and is limited to only one entry direction.
14.
Take the following steps to avoid malfunction due to noise.
1) Eliminate power supply noise during operation by installing
a line filter, etc. in the AC power line.
2) For avoiding the influence of noise or static electricity, install
this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc.
3) Make sure to take protective measures against load surge
for an induction load (solenoid valves, relays, etc.).
15. Refer to the instruction manual included with the product for details on its handling.
Caution
Series ITV009/209Precautions
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 7
Specific Product Precautions 6
Series ITV0000/1000/2000/3000
Handling
1. Connect the vacuum pump to the port, which is la­beled “VAC”.
2. Pressure adjustment changes from “atmospheric pressure to vacuum pressure” when the input sig­nal is increased, and from “vacuum pressure to at­mospheric pressure” when the input signal is de­creased.
3. When adjusting the vacuum pressure, be careful not to block the atmospheric pressure inlet port labeled “ATM”.
4. Since this product is designed exclusively for use with negative pressure, be careful not to apply posi­tive pressure in error.
5. In cases where the vacuum pump being used has a relatively small capacity, or the piping has a small inside diameter, etc., large variations in the set pressure (the range of pressure variation when changing from no flow to flow state) may appear. In this situation, the vacuum pump or the piping, etc. should be changed. In cases where it is not practi­cal to change the vacuum pump, install a capacity tank (volume depending on the operating condi­tions) on the VAC side.
6. The vacuum pressure response time after a change in the input signal is influenced by the internal volu­me on the setting side (including piping). Since the capacity of the vacuum pump also influences the response time, give careful consideration to these points before operation.
7. If the electric power is shut off when in a control state, the pressure on the setting side will go into a holding condition. However, this setting side pres­sure will be held only temporarily and is not guaran­teed. In addition, when atmospheric pressure is de­sired, shut off the power after reducing the set pres­sure, and then introduce atmospheric pressure by using a vacuum release valve, etc.
8. If the power for this product is cut off by a power failure, etc. when it is in a controlled state, the set­ting side pressure will be held temporarily. Further, if operated without sealing the setting side so that atmospheric air is sucked in, handle with care as air will continue to be sucked in.
9.
If the VAC side pressure to this product is interrup­ted while the power is still on, the internal solenoid valve
will continue to operate and may cause a humming noise. Since this may shorten the life of the product, be sure to shut off the power when the VAC side pressure is shut off.
10.
The setting side pressure cannot be completely re­leased from this product in the range below –1.3 kPa. In cases where the pressure needs to be redu­ced completely to 0 kPa, install a 3 port valve, etc. on the setting side to discharge the residual pressu­re.
11.
This product is adjusted for each specification at the factory before shipment. Avoid careless disas
-
sembly or removal of parts, as this can cause failu
-
re.
12. The optional cable connector is a 4-wire type. When the monitor output (analog output, switch output) is not being used, keep
it from touching the other wi-
res, as this can cause malfunction.
13.
Use caution that the right angle cable does not rota­te and is limited to only one entry direction.
14.
Take the following steps to avoid malfunction due to noise.
1) Eliminate power supply noise during operation by installing
a line filter, etc. in the AC power line.
2) For avoiding the influence of noise or static electricity, install
this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc.
3) Make sure to take protective measures against load surge
for an induction load (solenoid valves, relays, etc.).
15. Refer to the instruction manual included with the product for details on its handling.
Caution
Series ITV009/209Precautions
Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions.
Back page 8
SMC CORPORATION
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362
Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
ARGENTINA, AUSTRALIA, BOLIVIA, BRASIL, CANADA, CHILE,
CHINA, HONG KONG, INDIA, INDONESIA, MALAYSIA, MEXICO,
NEW ZEALAND, PHILIPPINES, SINGAPORE, SOUTH KOREA,
TAIWAN, THAILAND, USA, VENEZUELA
OTHER SUBSIDIARIES WORLDWIDE:
© DiskArt1988
© DiskArt™
UK
SMC Pneumatics (UK) Lt
d Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN Phone: +44 (0)845 121 5122 Fax: +44 (0)1908-555064 E-mail: sales@smcpneumatics.co.uk http://www.smcpneumatics.co.uk
Austria
SMC Pneumatik GmbH (Austria). Girakstrasse 8, A-2100 Korneuburg Phone: +43 2262-622800, Fax: +43 2262-62285 E-mail: office@smc.at http://www.smc.at
Czech Republic
SMC Industrial Automation CZ s.r.o. Hudcova 78a, CZ-61200 Brno Phone: +420 5 414 24611, Fax: +420 5 412 18034 E-mail: office@smc.cz http://www.smc.cz
Portugal
SMC Sucursal Portugal, S.A. Rua de Engº Ferreira Dias 452, 4100-246 Porto Phone: +351 226 166 570, Fax: +351 226 166 589 E-mail: postpt@smc.smces.es http://www.smc.eu
Belgium
SMC Pneumatics N.V./S.A. Nijverheidsstraat 20, B-2160 Wommelgem Phone: +32 (0)3-355-1464, Fax: +32 (0)3-355-1466 E-mail: info@smcpneumatics.be http://www.smcpneumatics.be
Lithuania
SMC Pneumatics Lietuva, UAB Oslo g.1, LT-04123 Vilnius Phone: +370 5 2308118, Fax: +370 5 2648126 E-mail: info@smclt.lt http://www.smclt.lt
Latvia
SMC Pneumatics Latvia SIA Dzelzavas str. 120g, Riga LV-1021, LATVIA Phone: +371 67817700, Fax: +371 67817701 E-mail: info@smclv.lv http://www.smclv.lv
Sweden
SMC Pneumatics Sweden AB
Ekhagsvägen 29-31, S-141 71 Huddinge Phone: +46 (0)8-603 12 00, Fax: +46 (0)8-603 12 90 E-mail: post@smcpneumatics.se http://www.smc.nu
France
SMC Pneumatique, S.A. 1, Boulevard de Strasbourg, Parc Gustave Eiffel Bussy Saint Georges F-77607 Marne La Vallee Cedex 3 Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010 E-mail: contact@smc-france.fr http://www.smc-france.fr
Finland
SMC Pneumatics Finland Oy PL72, Tiistinniityntie 4, SF-02231 ESPOO Phone: +358 207 513513, Fax: +358 207 513595 E-mail: smcfi@smc.fi http://www.smc.fi
Estonia
SMC Pneumatics Estonia OÜ Laki 12, 106 21 Tallinn Phone: +372 6510370, Fax: +372 65110371 E-mail: smc@smcpneumatics.ee http://www.smcpneumatics.ee
Greece
SMC Hellas EPE Anagenniseos 7-9 - P.C. 14342. N. Philadelphia, Athens Phone: +30-210-2717265, Fax: +30-210-2717766 E-mail: sales@smchellas.gr http://www.smchellas.gr
Turkey
Entek Pnömatik San. ve Tic. A*. Perpa Ticaret Merkezi B Blok Kat:11 No: 1625, TR-34386, Okmeydani, Istanbul Phone: +90 (0)212-444-0762, Fax: +90 (0)212-221-1519 E-mail: smc@entek.com.tr http://www.entek.com.tr
Poland
SMC Industrial Automation Polska Sp.z.o.o. ul. Poloneza 89, PL-02-826 Warszawa, Phone: +48 22 211 9600, Fax: +48 22 211 9617 E-mail: office@smc.pl http://www.smc.pl
Netherlands
SMC Pneumatics BV De Ruyterkade 120, NL-1011 AB Amsterdam Phone: +31 (0)20-5318888, Fax: +31 (0)20-5318880 E-mail: info@smcpneumatics.nl http://www.smcpneumatics.nl
Ireland
SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin Phone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500 E-mail: sales@smcpneumatics.ie http://www.smcpneumatics.ie
Hungary
SMC Hungary Ipari Automatizálási Kft. Torbágy út 19, H-2045 Törökbálin
t Phone: +36 23 511 390, Fax: +36 23 511 391 E-mail: office@smc.hu http://www.smc.hu
Switzerland
SMC Pneumatik AG Dorfstrasse 7, CH-8484 Weisslinge
n Phone: +41 (0)52-396-3131, Fax: +41 (0)52-396-3191 E-mail: info@smc.ch http://www.smc.ch
Italy
SMC Italia S.p.A Via Garibaldi 62, I-20061 Carugate, (Milano) Phone: +39 (0)2-92711, Fax: +39 (0)2-9271365 E-mail: mailbox@smcitalia.it http://www.smcitalia.it
Germany
SMC Pneumatik GmbH Boschring 13-15, D-63329 Egelsbach Phone: +49 (0)6103-4020, Fax: +49 (0)6103-402139 E-mail: info@smc-pneumatik.de http://www.smc-pneumatik.de
Sloveni
a
SMC industrijska Avtomatika d.o.o. Mirnska cesta 7, SI-8210 Trebnj
e Phone: +386 7 3885412 Fax: +386 7 3885435 E-mail: office@smc.si http://www.smc.si
Slovakia
SMC Priemyselná Automatizáciá, s.r.o
. Fatranská 1223, 01301 Teplicka Nad Váhom Phone: +421 41 3213212 - 6 Fax: +421 41 3213210 E-mail: office@smc.sk http://www.smc.sk
Romania
SMC Romania sr
l Str Frunzei 29, Sector 2, Bucharest Phone: +40 213205111, Fax: +40 213261489 E-mail: smcromania@smcromania.ro http://www.smcromania.ro
Norway
SMC Pneumatics Norway A/
S Vollsveien 13 C, Granfos Næringspark N-1366 Lysaker Tel: +47 67 12 90 20, Fax: +47 67 12 90 21 E-mail: post@smc-norge.no http://www.smc-norge.no
Denmark
SMC Pneumatik A/S Egeskovvej 1, DK-8700 Horsens Phone: +45 70252900, Fax: +45 70252901 E-mail: smc@smcdk.com http://www.smcdk.com
Russia
SMC Pneumatik LLC. 4B Sverdlovskaja nab, St. Petersburg 195009 Phone.:+7 812 718 5445, Fax:+7 812 718 5449 E-mail: info@smc-pneumatik.ru http://www.smc-pneumatik.ru
Spain
SMC España, S.A. Zuazobidea 14, 01015 Vitoria Phone: +34 945-184 100, Fax: +34 945-184 124 E-mail: post@smc.smces.es http://www.smc.eu
http://www.smc.eu
http://www.smcworld.com