SMC Networks SMC6110L2 User Manual

INSTALLATION GUIDE
ta
SMC6110L2
TigerSwitchTM 10/100 8-Port 10/100 Managed Switch plus 2 Gigabit Combo Ports
TigerSwitch 10/100 Installation Guide
From SMC’s Tiger line of feature-rich workgroup LAN solutions
January 2008
Pub. # 150200065200A
E012008-AP-R01
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice.
Copyright © 2008 by
SMC Networks, Inc.
20 Mason
Irvine, CA 92618
All rights reserved. Printed in Taiwan
Trademarks: SMC is a registered trademark; and EZ Switch, TigerStack and TigerSwitch are
trademarks of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders.
Compliances and Safety Warnings
FCC - Class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
You may use unshielded twisted-pair (UTP) for RJ-45 connections - Category 3 or better for 10 Mbps connections, Category 5 or better for 100 Mbps connections, Category 5, 5e, or 6 for 1000 Mbps connections. For fiber optic connections, you may use 50/125 or 62.5/ 125 micron multimode fiber or 9/125 micron single-mode fiber.
Industry Canada - Class A
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Department of Communications.
Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Appareils Numériques,” NMB-003 édictée par le ministère des Communications.
Japan VCCI Class A
MIC Notice (Republic of Korea Only)
i
CE Mark Declaration of Conformance for EMI and Safety (EEC)
This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied:
RFI Emission: • Limit class A according to EN 55022:1998
• Limit class A for harmonic current emission according to EN 61000-3-2/1995
• Limitation of voltage fluctuation and flicker in low-voltage supply system according to EN 61000-3-3/1995
Immunity: • Product family standard according to EN 55024:1998
• Electrostatic Discharge according to EN 61000-4-2:1995 (Contact Discharge: ±4 kV, Air Discharge: ±8 kV)
• Radio-frequency electromagnetic field according to EN 61000-4-3:1996 (80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)
• Electrical fast tran sient/burst according to EN61000-4-4:1995 (AC/DC powe r supply: ±1 kV, Data/Signal lines: ±0.5 kV)
• Surge immunity test according to EN 61000-4-5:1995 (AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)
• Immunity to conducted disturbances, Induced by radio-frequency fields: EN 61000-4-6:1996 (0.15 - 80 MHz with 1 kHz AM 80% Modulation: 3 V/m)
• Power frequency magnetic field immunity test according to EN 61000-4-8:1993 (1 A/m at frequency 50 Hz)
• Voltage dips, short interruptions and voltage variations immunity test according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30% Reduction @500 ms, >95% Reduction @5000 ms)
LVD: • EN 60950-1:2001
Caution: Do not plug a phone jack connector in the RJ-45 port. This may damage this
device.
Attention: Les raccordeurs ne sont pas utilisés pour le système téléphonique!
ii
Safety Compliance
Warning: Fiber Optic Port Safety
CLASS I
LASER DEVICE
When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on.
Avertissment: Ports pour fibres optiques - sécurité sur le plan optique
DISPOSITIF LASER
DE CLASSE I
Warnhinweis: Faseroptikanschlüsse - Optische Sicherheit
LASERGER DER KLASSE I
Ne regardez jamais le laser tant qu' il est sous tension. Ne regardez jamais directement le port TX (Transmission) à fibres optiques et les embouts de câbles à fibres optiques tant qu'ils sont sous tension.
Niemals ein Übertragungslaser betrachten, während dieses
ÄT
eingeschaltet ist. Niemals direkt auf den Faser-TX-Anschluß und auf die Faserkabelenden schauen, während diese eingeschaltet sind.
PSE Alarm
本製品に同梱いたしております電源コードセットは、 本製品専用です。本電源コードセットは、本製品以外の 製品並びに他の用途でご使用いただくことは出来ません。 製品本体に同梱された電源コードセットを利用し、他製品 の電源コードセットを使用しないで下さい。
Power Cord Safety
Please read the following safety information carefully before installing the switch: WARNING: Installation and removal of the unit must be carried out by qualified personnel
only.
• The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.
• Do not connect the uni t to an A. C. outle t (p ower suppl y) without an earth (ground) connection.
• The app li ance coupl er (the conne cto r to t he unit and not th e wall plu g) must have a configuration for mating with an EN 60320/IEC 320 appliance inlet.
• The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet.
• This unit operates under SELV (Saf ety Extra Low Voltage) conditi ons according to IEC 60950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth (ground).
Impédance à la terre
supplies. If your supplies are of IT type, this unit
iii
Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following:
Power Cord Set
U.S.A. and Canada The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor The cord set must have a rated current capacity of at least 10 A The attachment plug must be an earth- grounding type with NEMA
5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 25 0 V) configuration.
Denmark The supply plug must comply with Section 107-2-D1, Standard
Switzerland The supply plug must comply with SEV/A SE 1011. U.K. The supply plug must comply with BS1363 (3-pin 13 A) and be fitted
Europe The supply plug must comply with CEE7/7 (“SCHUKO”).
DK2-1a or DK2-5a.
with a 5 A fuse which complies with BS1362. The mains cord must be <HAR> or <BA SEC> marked and be of type
HO3VVF3GO.75 (minimum).
The mains cord must be <HAR> or <BA SEC> marked and be of type HO3VVF3GO.75 (minimum).
IEC-320 receptacle.
Veuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch: AVERTISSEMENT: L’installation et la dépose de ce groupe doivent être confiés à un
personnel qualifié.
• Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).
• Vous devez raccorder ce groupe à une sortie mi se à la terre (mise à la masse) afin de respecter les normes internationales de sécurité.
• Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale) doit respecter une configuration qui permet un branchement sur une entré e d’appareil EN 60320/IEC 320.
• La prise secteur doit se trouver à proximité de l’appareil et son accès doit être facile. Vous ne pouvez mettre l’appareil hors circuit q u’en débranchant son cordon électrique au niveau de cette prise.
• L’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
iv
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec raccordement direct à la terre (masse).
Cordon électrique - Il doit être agréé dans l e pay s d’utilisation
Etats-Unis et Canada:
Danemark: La prise mâle d’alimentation doit respecter la section 107-2 D1 de la
Suisse: La pr ise mâ le d’ alimen tatio n do it re spec ter l a no rme S EV/A SE 10 11. Europe La prise secteur doit être conforme aux normes CEE 7/7 (“SCHUKO”)
Le cordon doit avoir reçu l’homologation des UL et un certificat de la CSA.
Les spécifications minimales pour un cable flexible sont AWG No. 18, ouAWG No. 16 pour un cable de longueur inférieure à 2 mètres.
- type SV ou SJ
- 3 conducteurs Le cordon doit être en mesure d’acheminer un courant nominal d’au
moins 10 A. La prise femelle de branchemen t doit être du type à mise à la terre
(mise à la masse) et respecter la conf iguration NEMA 5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V).
norme DK2 1a ou DK2 5a.
LE cordon secteur doit porter la mention <HAR> ou <BASEC> et doit être de type HO3VVF3GO.75 (minimum).
Bitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen:
WARNUNG: Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal
erfolgen.
• Das Gerät so llte nicht an eine ungeerdete Wechselstroms teckdose angeschlossen
werden.
• Das Gerät muß an eine geerdete Steckdose angeschlossen werden, welche die
internationalen Sicherheitsnormen erfüllt.
• Der Gerätestec ker (der Anschluß an das Gerät, nicht der Wandsteckdosenstec ker)
muß einen gemäß EN 60320/IEC 320 konfigurierten Geräteeingang haben.
• Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die
Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.
• Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 60950. Diese Bedingungen sind nur gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter SELV-Bedingungen betrieben werden.
v
Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft werden:
Schweiz Dieser Stromstecker muß die SEV/ASE 1011 Bestimmungen einhalt-
Europe Das Netzkabel muß vom Typ HO3VVF3GO.75 (Mindestanforderung)
en.
sein und die Aufschrift <HAR> oder <BASEC> tragen. Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).
Warnings and Cautionary Messages
Warning: This product does not contain any serviceable user parts. Warning: Installation and removal of the unit must be carried out by qualified
personnel only.
Warning: When connecting this device to a power outlet, connect the field ground lead
on the tri-pole power plug to a valid earth ground line to prevent electrical hazards.
Warning: This switch uses lasers to transmit signals over fiber optic cable. The lasers
are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on.
Caution: Wear an anti-static wrist strap or take other suitable measures to prevent
electrostatic discharge when handling this equipment.
Caution: Do not plug a phone jack connector in the RJ-45 port. This may damage this
device. Les raccordeurs ne sont pas utilisé pour le système téléphonique!
Caution: Use only twisted-pair cables with RJ-45 connectors that conform to FCC
standards.
Warnings (in German)
Achtung: Dieses Produkt enthält keine Teile, die eine Wartung vom Benutzer
benötigen.
Achtung: Installation und Deinstallation des Gerätes müssen von qualifiziertem
Servicepersonal durchgeführt werden.
Achtung: Wenn das Gerät an eine Steckdose angeschlossen wird, muß der
Achtung: Dieses Gerät nutzt Laser zur Signalübertragung über Glasfasern. Die Laser
vi
Masseanschluß am dreipoligen Netzstecker mit Schutzerde verbunden werden, um elektrische Gefahren zu vermeiden.
entsprechen den Anforderungen an eine Lasereinrichtung der Klasse 1 und sind durch ihre Bauart im normalen Betrieb sicher für die Augen. Trotzdem sollte niemals direkt in den einen Übertragungskanal geblickt werden, wenn er eingeschaltet ist.
Environmental Statement
The manufacturer of this product endeavours to sustain an environmentally-friendly policy throughout the entire production process. This is achieved though the following means:
• Adherence to national legislation and regulations on envir onmental production
standards.
• Cons ervation of operational resources.
• Waste reduction and safe disposal of all harmful un-recyclable by-products.
• Recycling of all reusable waste content.
• Design of products to maximize recyclables at the end of the product’s life span.
• Continual monitoring of safety standards.
End of Product Life Span
This product is manufactured in such a way as to allow for the recovery and disposal of all included electrical components once the product has reached the end of its life.
Manufacturing Materials
There are no hazardous nor ozone-depleting materials in this product.
Documentation
All printed documentation for this product uses biodegradable paper that originates from sustained and managed forests. The inks used in the printing process are non-toxic.
vii
viii
About This Guide
Purpose
This guide details the hardware features of the switch, including the physical and performance-related characteristics, and how to install the switch.
Audience
The guide is intended for use by network administrators who are responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
Conventions
The following conventions are used throughout this guide to show information: Note: Emphasizes important information or calls your attention to related features or
instructions.
Caution: Alerts you to a potential hazard that could cause loss of data, or damage the
system or equipment.
Warning: Alerts you to a potential hazard that could cause personal injury.
Related Publications
The following publication gives specific information on how to operate and use the management functions of the switch:
The Management Guide Also, as part of the switch’s software, there is an online web-based help that describes all
management related features.
Revision History
This section summarizes the changes in each revision of this guide.
January 2008 Revision
This is the first revision of this guide.
ix
x
Contents
Chapter 1: Introduction 1-1
Overview 1-1
Switch Architecture 1-2 Network Management Options 1-2
Description of Hardware 1-2
10BASE-T/100BASE-TX Ports 1-2 1000BASE-T/SFP Ports 1-3 Port and System Status LEDs 1-3 Power Supply Socket 1-4
Features and Benefits 1-4
Connectivity 1-4 Expandability 1-5 Performance 1-5 Management 1-5
Chapter 2: Network Planning 2-1
Introduction to Switching 2-1 Application Examples 2-2
Collapsed Backbone 2-2 Network Edge Deployment 2-3
Application Notes 2-4
Chapter 3: Installing the Switch 3-1
Selecting a Site 3-1 Ethernet Cabling 3-1 Equipment Checklist 3-2
Package Contents 3-2 Optional Rack-Mounting Equipment 3-2
Mounting 3-3
Rack Mounting 3-3
Desktop or Shelf Mounting 3-5 Installing an Optional SFP Transceiver 3-5 Connecting to a Power Source 3-6 Connecting to the Console Port 3-7
Wiring Map for Serial Cable 3-7
xi
Contents
Chapter 4: Making Network Connections 4-1
Connecting Network Devices 4-1 Twisted-Pair Devices 4-1
Cabling Guidelines 4-1 Connecting to PCs, Servers, Hubs and Switches 4-2 Network Wiring Connections 4-2
Fiber Optic SFP Devices 4-4 Connectivity Rules 4-5
1000BASE-T Cable Requirements 4-5 1000 Mbps Gigabit Ethernet Collision Domain 4-6 100 Mbps Fast Ethernet Collision Domain 4-6 10 Mbps Ethernet Collision Domain 4-6
Cable Labeling and Connection Records 4-7
Appendix A: Troubleshooting A-1
Diagnosing Switch Indicators A-1 Power and Cooling Problems A-1 Installation A-1 In-Band Access A-2
Appendix B: Cables B-1
Twisted-Pair Cable and Pin Assignments B-1
10BASE-T/100BASE-TX Pin Assignments B-1 Straight-Through Wiring B-2 Crossover Wiring B-3 1000BASE-T Pin Assignments B-3
Fiber Standards B-4
Appendix C: Specifications C-1
Switch Features C-2 Management Features C-2 Standards C-3 Compliances C-3
Appendix D: Ordering Information D-1
Glossary
Index
xii
Tables
Table 1-1 Port Status LEDs 1-3 Table 1-2 System Status LEDs 1-4 Table 3-1 Serial Cable Wiring 3-8 Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length 4-6 Table 4-2 Maximum 1000BASE-SX Gigabit Ethernet Cable Lengths 4-6 Table 4-3 Maximum 1000BASE-LX Gigabit Ethernet Cable Length 4-6 Table 4-4 Maximum 1000BASE-LH Gigabit Ethernet Cable Length 4-6 Table 4-5 Maximum Fast Ethernet Cable Lengths 4-6 Table 4-6 Maximum Ethernet Cable Length 4-6 Table A-1 Troubleshooting Chart A-1 Table B-1 10/100BASE-TX MDI and MDI-X Port Pinouts B-2 Table B-2 1000BASE-T MDI and MDI-X Port Pinouts B-3
xiii
Figures
Figure 1-1 Front and Rear Panels 1-1 Figure 1-2 Port LEDs 1-3 Figure 1-3 Power Supply Socket 1-4 Figure 2-1 Collapsed Backbone 2-2 Figure 2-2 Network Edge Deployment 2-3 Figure 3-1 RJ-45 Connections 3-2 Figure 3-2 Attaching the Brackets 3-3 Figure 3-3 Installing the Switch in a Rack 3-4 Figure 3-4 Attaching the Adhesive Feet 3-5 Figure 3-5 Inserting an SFP Transceiver into a Slot 3-5 Figure 3-6 Power Socket 3-6 Figure 3-7 Serial Port (DB-9 DTE) Pin-Out 3-7 Figure 4-1 Making Twisted-Pair Connections 4-2 Figure 4-2 Network Wiring Connections 4-3 Figure 4-3 Making Fiber Port Connections 4-5 Figure B-1 RJ-45 Connector Pin Numbers B-1 Figure B-2 Straight-through Wiring B-2 Figure B-3 Crossover Wiring B-3
xiv

Chapter 1: Introduction

Overview

The SMC6110 L2 i s a Fas t Ethe rn et switc h wit h ei ght10BASE-T/100BASE-TX ports and two 1000BASE-T ports that operate in combination with two Small Form Factor
Pluggable (SFP) transceiver slots includes an SNMP-based management agent, which provides both in-band and out-of-band access for managing the switch.
The SMC6110L2 provides a broad range of powerful features for Layer 2 switching, delivering reliability and consistent performance for your network tr affic. It brings order to poorly performing networks by segregating them into separate broadcast domains with IEEE 802.1Q compliant VLANs, and empowers multimedia applications with multicast switching and CoS services.
*
(see Figure 1-1, Ports 9-10). The switch also
System Indicators
Console Port
Port Status Indicators
10/100 Mbps RJ-45 Ports
Power Socket
Figure 1-1 Front and Rear Panels
1000BASE-T/SFP Ports
* If an SFP transceiver is plugged in, the corresponding RJ-45 port is disabled for ports 9-10.
1-1
Introduction
1

Switch Architecture

The switch employs a wire-speed, non-blocking switching fabric. This permits simultaneous wire-speed transport of multiple packets at low latency on all ports. The switch also features full-duplex capability on all ports, which effectively doubles the bandwidth of each connection.
This switch uses store-and-forward switching to ensure maximum data integrity. With store-and-forward switching, the entire packet must be received into a buffer and checked for validity before being forwarded. This prevents errors from being propagated throughout the network.

Network Management Options

With a comprehensive array of LEDs, the switch provides “at a glance” monitorin g of network and port status. The switch can be managed over the net work with a web browser or Telnet application, or via a direct connection to the console port. The switch includes a built-in network management agent that allows it to be managed in-band using SNMP or RMON (Groups 1, 2, 3, 9) protocols. It also has an RS-232 serial port (DB-9 connector) on the rear panel for out-of-band management. A PC may be connected to this port null-modem serial cable. (See Appendix B for wiring options.)
For a detailed description of the management features, refer to the Management Guide.
for configuration and monitoring out-of-band via a

Description of Hardware

10BASE-T/100BASE-TX Ports

The switch contains eight 10BASE-T/100BASE-TX RJ-45 ports. All ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs. (See “10BASE-T/100BASE-TX Pin Assignments” on page B-1.)
Each of these ports support auto-negotiation, so the optimu m tr ansmission mode (half or full duplex), and data ra te (10 o r 100 Mbp s) ca n be sel ected aut omatic all y. If a device connected to one of these ports does not support auto-negotiation, the communication mode of that port can be configured manually.
Each port also supports IEEE 802.3x auto-negotiation of flow control, so the switch can automatically prevent port buffers from becoming saturated.
1-2