From SMC’s Tiger line of feature-rich workgroup LAN solutions
20 Mason
Irvine, CA 92618
Phone: (949) 679-8000
January 2008
Pub. # 150200065200A
E012008-AP-R01
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and
reliable. However, no responsibility is assumed by SMC for its use, nor for any
infringements of patents or other rights of third parties which may result from its use. No
license is granted by implication or otherwise under any patent or patent rights of SMC.
SMC reserves the right to change specifications at any time without notice.
Trademarks:
SMC is a registered trademark; and EZ Switch, TigerStack and TigerSwitch are
trademarks of SMC Networks, Inc. Other product and company names are trademarks or
registered trademarks of their respective holders.
Compliances and Safety Warnings
FCC - Class A
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
You are cautioned that changes or modifications not expressly approved by the party
responsible for compliance could void your authority to operate the equipment.
You may use unshielded twisted-pair (UTP) for RJ-45 connections - Category 3 or better
for 10 Mbps connections, Category 5 or better for 100 Mbps connections, Category 5, 5e,
or 6 for 1000 Mbps connections. For fiber optic connections, you may use 50/125 or 62.5/
125 micron multimode fiber or 9/125 micron single-mode fiber.
Industry Canada - Class A
This digital apparatus does not exceed the Class A limits for radio noise emissions from
digital apparatus as set out in the interference-causing equipment standard entitled
“Digital Apparatus,” ICES-003 of the Department of Communications.
Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux
appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur:
“Appareils Numériques,” NMB-003 édictée par le ministère des Communications.
Japan VCCI Class A
MIC Notice (Republic of Korea Only)
i
CE Mark Declaration of Conformance for EMI and Safety (EEC)
This information technology equipment complies with the requirements of the Council
Directive 89/336/EEC on the Approximation of the laws of the Member States relating to
Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain
voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the
compliance with these Directives, the following standards were applied:
RFI Emission: • Limit class A according to EN 55022:1998
• Limit class A for harmonic current emission according to EN 61000-3-2/1995
• Limitation of voltage fluctuation and flicker in low-voltage supply system
according to EN 61000-3-3/1995
Immunity:• Product family standard according to EN 55024:1998
• Electrostatic Discharge according to EN 61000-4-2:1995
(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)
• Radio-frequency electromagnetic field according to EN 61000-4-3:1996
(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)
• Electrical fast tran sient/burst according to EN61000-4-4:1995 (AC/DC powe r
supply: ±1 kV, Data/Signal lines: ±0.5 kV)
• Surge immunity test according to EN 61000-4-5:1995
(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)
• Immunity to conducted disturbances, Induced by radio-frequency fields:
EN 61000-4-6:1996 (0.15 - 80 MHz with 1 kHz AM 80% Modulation: 3 V/m)
• Power frequency magnetic field immunity test according to
EN 61000-4-8:1993
(1 A/m at frequency 50 Hz)
• Voltage dips, short interruptions and voltage variations immunity test
according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30%
Reduction @500 ms, >95% Reduction @5000 ms)
LVD:• EN 60950-1:2001
Caution: Do not plug a phone jack connector in the RJ-45 port. This may damage this
device.
Attention: Les raccordeurs ne sont pas utilisés pour le système téléphonique!
ii
Safety Compliance
Warning: Fiber Optic Port Safety
CLASS I
LASER DEVICE
When using a fiber optic port, never look at the transmit laser while it is
powered on. Also, never look directly at the fiber TX port and fiber cable
ends when they are powered on.
Avertissment: Ports pour fibres optiques - sécurité sur le plan optique
Ne regardez jamais le laser tant qu' il est sous tension. Ne regardez
jamais directement le port TX (Transmission) à fibres optiques et les
embouts de câbles à fibres optiques tant qu'ils sont sous tension.
Niemals ein Übertragungslaser betrachten, während dieses
ÄT
eingeschaltet ist. Niemals direkt auf den Faser-TX-Anschluß
und auf die Faserkabelenden schauen, während diese
eingeschaltet sind.
Please read the following safety information carefully before installing the switch:
WARNING: Installation and removal of the unit must be carried out by qualified personnel
only.
• The unit must be connected to an earthed (grounded) outlet to comply with
international safety standards.
• Do not connect the uni t to an A. C. outle t (p ower suppl y) without an earth (ground)
connection.
• The app li ance coupl er (the conne cto r to t he unit and not th e wall plu g) must have
a configuration for mating with an EN 60320/IEC 320 appliance inlet.
• The socket outlet must be near to the unit and easily accessible. You can only
remove power from the unit by disconnecting the power cord from the outlet.
• This unit operates under SELV (Saf ety Extra Low Voltage) conditi ons according to
IEC 60950. The conditions are only maintained if the equipment to which it is
connected also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the
secondary connection point labelled Neutral, connected directly to earth (ground).
†
Impédance à la terre
†
supplies. If your supplies are of IT type, this unit
iii
Important! Before making connections, make sure you have the correct cord set. Check
it (read the label on the cable) against the following:
Power Cord Set
U.S.A. and CanadaThe cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A
The attachment plug must be an earth- grounding type with NEMA
5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 25 0 V) configuration.
DenmarkThe supply plug must comply with Section 107-2-D1, Standard
SwitzerlandThe supply plug must comply with SEV/A SE 1011.
U.K.The supply plug must comply with BS1363 (3-pin 13 A) and be fitted
EuropeThe supply plug must comply with CEE7/7 (“SCHUKO”).
DK2-1a or DK2-5a.
with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BA SEC> marked and be of type
HO3VVF3GO.75 (minimum).
The mains cord must be <HAR> or <BA SEC> marked and be of type
HO3VVF3GO.75 (minimum).
IEC-320 receptacle.
Veuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch:
AVERTISSEMENT: L’installation et la dépose de ce groupe doivent être confiés à un
personnel qualifié.
• Ne branchez pas votre appareil sur une prise secteur (alimentation électrique)
lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).
• Vous devez raccorder ce groupe à une sortie mi se à la terre (mise à la masse) afin
de respecter les normes internationales de sécurité.
• Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale) doit
respecter une configuration qui permet un branchement sur une entré e d’appareil
EN 60320/IEC 320.
• La prise secteur doit se trouver à proximité de l’appareil et son accès doit être
facile. Vous ne pouvez mettre l’appareil hors circuit q u’en débranchant son cordon
électrique au niveau de cette prise.
• L’appareil fonctionne à une tension extrêmement basse de sécurité qui est
conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si
l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
iv
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos
alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une
tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 1:1, avec
un point secondaire de connexion portant l’appellation Neutre et avec raccordement
direct à la terre (masse).
Cordon électrique - Il doit être agréé dans l e pay s d’utilisation
Etats-Unis et
Canada:
Danemark:La prise mâle d’alimentation doit respecter la section 107-2 D1 de la
Suisse:La pr ise mâ le d’ alimen tatio n do it re spec ter l a no rme S EV/A SE 10 11.
EuropeLa prise secteur doit être conforme aux normes CEE 7/7 (“SCHUKO”)
Le cordon doit avoir reçu l’homologation des UL et un certificat de la
CSA.
Les spécifications minimales pour un cable flexible sont AWG No. 18,
ouAWG No. 16 pour un cable de longueur inférieure à 2 mètres.
- type SV ou SJ
- 3 conducteurs
Le cordon doit être en mesure d’acheminer un courant nominal d’au
moins 10 A.
La prise femelle de branchemen t doit être du type à mise à la terre
(mise à la masse) et respecter la conf iguration NEMA 5-15P (15 A,
125 V) ou NEMA 6-15P (15 A, 250 V).
norme DK2 1a ou DK2 5a.
LE cordon secteur doit porter la mention <HAR> ou <BASEC> et doit
être de type HO3VVF3GO.75 (minimum).
Bitte unbedingt vor dem Einbauen des Switches die folgenden
Sicherheitsanweisungen durchlesen:
WARNUNG: Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal
erfolgen.
• Das Gerät so llte nicht an eine ungeerdete Wechselstroms teckdose angeschlossen
werden.
• Das Gerät muß an eine geerdete Steckdose angeschlossen werden, welche die
internationalen Sicherheitsnormen erfüllt.
• Der Gerätestec ker (der Anschluß an das Gerät, nicht der Wandsteckdosenstec ker)
muß einen gemäß EN 60320/IEC 320 konfigurierten Geräteeingang haben.
• Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die
Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels
aus der Netzsteckdose unterbrochen werden.
• Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 60950. Diese Bedingungen sind nur
gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter
SELV-Bedingungen betrieben werden.
v
Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft werden:
SchweizDieser Stromstecker muß die SEV/ASE 1011 Bestimmungen einhalt-
EuropeDas Netzkabel muß vom Typ HO3VVF3GO.75 (Mindestanforderung)
en.
sein und die Aufschrift <HAR> oder <BASEC> tragen.
Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).
Warnings and Cautionary Messages
Warning: This product does not contain any serviceable user parts.
Warning: Installation and removal of the unit must be carried out by qualified
personnel only.
Warning: When connecting this device to a power outlet, connect the field ground lead
on the tri-pole power plug to a valid earth ground line to prevent electrical
hazards.
Warning: This switch uses lasers to transmit signals over fiber optic cable. The lasers
are compliant with the requirements of a Class 1 Laser Product and are
inherently eye safe in normal operation. However, you should never look
directly at a transmit port when it is powered on.
Caution:Wear an anti-static wrist strap or take other suitable measures to prevent
electrostatic discharge when handling this equipment.
Caution:Do not plug a phone jack connector in the RJ-45 port. This may damage this
device. Les raccordeurs ne sont pas utilisé pour le système téléphonique!
Caution:Use only twisted-pair cables with RJ-45 connectors that conform to FCC
standards.
Warnings (in German)
Achtung: Dieses Produkt enthält keine Teile, die eine Wartung vom Benutzer
benötigen.
Achtung: Installation und Deinstallation des Gerätes müssen von qualifiziertem
Servicepersonal durchgeführt werden.
Achtung: Wenn das Gerät an eine Steckdose angeschlossen wird, muß der
Achtung: Dieses Gerät nutzt Laser zur Signalübertragung über Glasfasern. Die Laser
vi
Masseanschluß am dreipoligen Netzstecker mit Schutzerde verbunden
werden, um elektrische Gefahren zu vermeiden.
entsprechen den Anforderungen an eine Lasereinrichtung der Klasse 1 und
sind durch ihre Bauart im normalen Betrieb sicher für die Augen. Trotzdem
sollte niemals direkt in den einen Übertragungskanal geblickt werden, wenn
er eingeschaltet ist.
Environmental Statement
The manufacturer of this product endeavours to sustain an environmentally-friendly policy
throughout the entire production process. This is achieved though the following means:
• Adherence to national legislation and regulations on envir onmental production
standards.
• Cons ervation of operational resources.
• Waste reduction and safe disposal of all harmful un-recyclable by-products.
• Recycling of all reusable waste content.
• Design of products to maximize recyclables at the end of the product’s life span.
• Continual monitoring of safety standards.
End of Product Life Span
This product is manufactured in such a way as to allow for the recovery and disposal of all
included electrical components once the product has reached the end of its life.
Manufacturing Materials
There are no hazardous nor ozone-depleting materials in this product.
Documentation
All printed documentation for this product uses biodegradable paper that originates from
sustained and managed forests. The inks used in the printing process are non-toxic.
vii
viii
About This Guide
Purpose
This guide details the hardware features of the switch, including the physical and
performance-related characteristics, and how to install the switch.
Audience
The guide is intended for use by network administrators who are responsible for installing
and setting up network equipment; consequently, it assumes a basic working knowledge
of LANs (Local Area Networks).
Conventions
The following conventions are used throughout this guide to show information:
Note: Emphasizes important information or calls your attention to related features or
instructions.
Caution: Alerts you to a potential hazard that could cause loss of data, or damage the
system or equipment.
Warning: Alerts you to a potential hazard that could cause personal injury.
Related Publications
The following publication gives specific information on how to operate and use the
management functions of the switch:
The Management Guide
Also, as part of the switch’s software, there is an online web-based help that describes all
management related features.
Revision History
This section summarizes the changes in each revision of this guide.
Figure 1-1Front and Rear Panels 1-1
Figure 1-2Port LEDs 1-3
Figure 1-3Power Supply Socket 1-4
Figure 2-1Collapsed Backbone 2-2
Figure 2-2Network Edge Deployment 2-3
Figure 3-1RJ-45 Connections 3-2
Figure 3-2Attaching the Brackets 3-3
Figure 3-3Installing the Switch in a Rack 3-4
Figure 3-4Attaching the Adhesive Feet 3-5
Figure 3-5Inserting an SFP Transceiver into a Slot 3-5
Figure 3-6Power Socket 3-6
Figure 3-7Serial Port (DB-9 DTE) Pin-Out 3-7
Figure 4-1Making Twisted-Pair Connections 4-2
Figure 4-2Network Wiring Connections 4-3
Figure 4-3Making Fiber Port Connections 4-5
Figure B-1RJ-45 Connector Pin Numbers B-1
Figure B-2Straight-through Wiring B-2
Figure B-3Crossover Wiring B-3
xiv
Chapter 1: Introduction
Overview
The SMC6110 L2 i s a Fas t Ethe rn et switc h wit h ei ght10BASE-T/100BASE-TX ports
and two 1000BASE-T ports that operate in combination with two Small Form Factor
Pluggable (SFP) transceiver slots
includes an SNMP-based management agent, which provides both in-band and
out-of-band access for managing the switch.
The SMC6110L2 provides a broad range of powerful features for Layer 2 switching,
delivering reliability and consistent performance for your network tr affic. It brings
order to poorly performing networks by segregating them into separate broadcast
domains with IEEE 802.1Q compliant VLANs, and empowers multimedia
applications with multicast switching and CoS services.
*
(see Figure 1-1, Ports 9-10). The switch also
System Indicators
Console Port
Port Status Indicators
10/100 Mbps RJ-45 Ports
Power Socket
Figure 1-1 Front and Rear Panels
1000BASE-T/SFP Ports
* If an SFP transceiver is plugged in, the corresponding RJ-45 port is disabled for ports 9-10.
1-1
Introduction
1
Switch Architecture
The switch employs a wire-speed, non-blocking switching fabric. This permits
simultaneous wire-speed transport of multiple packets at low latency on all ports.
The switch also features full-duplex capability on all ports, which effectively doubles
the bandwidth of each connection.
This switch uses store-and-forward switching to ensure maximum data integrity.
With store-and-forward switching, the entire packet must be received into a buffer
and checked for validity before being forwarded. This prevents errors from being
propagated throughout the network.
Network Management Options
With a comprehensive array of LEDs, the switch provides “at a glance” monitorin g of
network and port status. The switch can be managed over the net work with a web
browser or Telnet application, or via a direct connection to the console port. The
switch includes a built-in network management agent that allows it to be managed
in-band using SNMP or RMON (Groups 1, 2, 3, 9) protocols. It also has an RS-232
serial port (DB-9 connector) on the rear panel for out-of-band management. A PC
may be connected to this port
null-modem serial cable. (See Appendix B for wiring options.)
For a detailed description of the management features, refer to the Management Guide.
for configuration and monitoring out-of-band via a
Description of Hardware
10BASE-T/100BASE-TX Ports
The switch contains eight 10BASE-T/100BASE-TX RJ-45 ports. All ports support
automatic MDI/MDI-X operation, so you can use straight-through cables for all
network connections to PCs or servers, or to other switches or hubs. (See
“10BASE-T/100BASE-TX Pin Assignments” on page B-1.)
Each of these ports support auto-negotiation, so the optimu m tr ansmission mode
(half or full duplex), and data ra te (10 o r 100 Mbp s) ca n be sel ected aut omatic all y. If
a device connected to one of these ports does not support auto-negotiation, the
communication mode of that port can be configured manually.
Each port also supports IEEE 802.3x auto-negotiation of flow control, so the switch
can automatically prevent port buffers from becoming saturated.
1-2
Description of Hardware
1000BASE-T/SFP Ports
These are combination Gigabit RJ-45 ports with shared Small Form Factor
Pluggable (SFP) transceiver slots. If an SFP transceiver (purchased separately) is
installed in a slot and has a valid link on the port, the associated RJ-45 port is
disabled.
The 1000BASE-T RJ-45 ports support automatic MDI/MDI-X operation, so you can
use straight-through cables for all network connections to PCs or servers, or to other
switches or hubs. (See “1000BASE-T Pin Assignments” on page B-3.)
Port and System Status LEDs
The switch includes a display panel for key system and port indications that simplify
installation and network troubleshooting. The LEDs , which are located on the front
panel for easy viewing, are shown below and described in the following tables.
Port Status LEDsSystem Status LEDs
1
Figure 1-2 Port LEDs
Table 1-1 Port Status LEDs
LEDConditionStatus
Fast Ethernet Ports (Ports 1-8)
(Link/Activity)On/Flashing
Port has established a valid 10 Mbps network connection.
Flashing indicates activ ity.
Port has established a valid 100 Mbps network connection.
Flashing indicates activ ity.
Port has established a valid 10/100 Mbps network connection.
Flashing indicates activ ity.
Port has established a valid 1000 Mbps network connection.
Flashing indicates activ ity.
1-3
Introduction
1
Table 1-2 System Status LEDs
LEDConditionStatus
PWROn GreenThe unit’s internal power supply is operating normally.
OffThe unit has no power connected.
DiagOn GreenThe system diagnostic test has completed successfully.
Flashing GreenThe system diagnostic test is in progress.
On AmberThe system diagnostic test has detected a fault.
Power Supply Socket
There is one power socket on the rear panel of the switch. The standard power
socket is for the AC power cord.
Figure 1-3 Power Supply Socket
Features and Benefits
Connectivity
• Eight du al-speed ports for easy Fast Ethernet integration and for prot ection of your
investment in legacy LAN equipment.
• Auto-negotiation enables each RJ-45 port to automatically select the optimum
communication mode (half or full duplex) if this feature is su pported by the
attached device; otherwise the port can be configured manually.
• RJ-45 10/100BASE-TX ports with auto MDI/MDI-X.
• Unshielded (UTP) cable supported on all RJ-45 ports: Category 3 or better for
10 Mbps connections, Category 5 or better for 100 Mbps connections, and
Category 5, 5e or 6 for 1000 Mbps connections.
• IEEE 802.3-200 5 Ethernet, Fast Ethernet, Gigabit Ethernet compliance ensures
compatibility with standards-based hubs, network cards and switc hes from any
vendor.
1-4
Features and Benefits
Expandability
• Two Small Form Factor Pluggable (SFP) transceiver slots (shared with
1000BASE-T ports)
• Supports 1000BASE-SX, 1000BASE-LX and 1000BASE-LH SFP transceivers.
Performance
• Transparent bridging
• Aggregate duplex bandwidth of up to 5.6 Gbps
• Switching table with a total of 8K MAC address entries
• Provides store-and-forward switching
• Wire-speed filtering and forwarding
• Su pports flow control, us ing back pressure for h alf duplex and IEEE 802 .3x for full
A network switch allows simultaneous transmission of multiple packets via
non-crossbar switching. This means that it can partition a network more efficiently
than bridges or routers. The switch has, therefore, been recognized as one of the
most important building blocks for today’s networking technology.
When performance bottlenecks are caused by congestion at the network access
point (such as the network card for a high-volume file server), the device
experiencing congestion (server, power user, or hub) can be attached directly to a
switched port. And, by using full-duplex mode, the bandwidth of the dedicated
segment can be doubled to maximize throughput.
When networks are based on repeater (hub) technology, the distance between end
stations is limited by a maximum hop count. However, a switch turns the hop count
back to zero. So subdividing the network into smaller and more manageable
segments, and linking them to the larger network by means of a switch, removes thi s
limitation.
A switch can be easily configured in any Ethernet, Fast Ethernet, or Gigabit Et hernet
network to significantly boost bandwidth while using conventional cabling and
network cards.
2-1
Network Planning
2
Application Examples
The switch is not only designed to segment your network, but also to provide a wi de
range of options in setting up network connections. Some typi cal applications are
described below .
Collapsed Backbone
The switch is an excellent choice for mixed Ethernet, Fast Ethernet, and Gigabit
Ethernet installations where significant growth is expected in the near future. You
can easily build on this basic configuration, adding direct full-duplex connections to
workstations or servers. When the time comes for f urth er expansion, just connect to
another hub or switch using one of the Fast Ethernet ports built into the front panel
or a Gigabit Ethernet port on a plug-in SFP transceiver.
In the figure below , t he switch i s operating as a colla psed backbone for a small L AN.
It is providing dedicated 10 Mbps full-duplex connections to workstations, 100 Mbps
full-duplex connections to power users, and 1 Gbps full-duplex connections to
servers.
2-2
...
Servers
1 Gbps
Full Duplex
...
Workstations
100 Mbps
Full Duplex
Figure 2-1 Collapsed Backbone
...
Workstations
10 Mbps
Full Duplex
Application Examples
Network Edge Deployment
With 8 1000 Mbps parallel bridging ports (i.e., 8 distinct collision domains), this
switch can function as an efficient bridged node that is ideal for a meeting room
environment. Zero noise makes the switch inobtrusive for such a setting.
In the figure below, the SMC6110L2 is connected to a central wiring closet via a
1000BASE-SX connection. The 1000BASE-T RJ-45 ports on the switch are
providing 10/100 Mbps full-duplex connections for PCs and notebooks.
2
Figure 2-2 Network Edge Deployment
2-3
Network Planning
2
Application Notes
1.Full-duplex operation only applies to point-to-point access (such as when a
switch is attached to a workstation, server or another switch). When the switch
is connected to a hub, both devices must operate in hal f-duplex mode.
2.Avoid using flow control on a port connected to a hub unless it is actually
required to solve a problem. Otherwise back pressure jamming signals may
degrade overall performance for the segment attached to the hub.
3.As a general rule the length of fiber optic cable for a singl e switched l ink sh ould
not exceed:
• 1000BASE-SX: 550 m (1805 ft) for multimode fiber.
• 1000BASE-LX: 5 km (3.1 miles) for single-mode fiber.
• 1000BASE-LH: 70 km (43.5 miles) for single-mode fiber.
However, power budget constraints must also be considered when calculating
the maximum cable length for your specific environment.
2-4
Chapter 3: Installing the Switch
Selecting a Site
Switch units can be mounted in a standard 19-inch equipment rack or on a flat
surface. Be sure to follow the guidelines below when choosing a location.
• The site should:
- be at the center of all the devices you want to link and near a power outlet.
- be able to maintain its temperature within 0 to 50 °C (32 to 122 °F) and its
humidity within 10% to 90%, non-condensing
- provide adequate space (approximately two inches) on all sides for proper air
flow
- be accessible for installing, cabling and maintaining the devices
- allow the status LEDs to be clearly visible
• Make sure t wisted-pair cable is al ways routed away from power lines, fluorescent
lighting fixtures and other sources of electrical interference, such as radios and
transmitters.
• Make sure that the unit is connected to a separate grounded power outlet that
provides 100 to 240 VAC, 50 to 60 Hz, is wit hin 2 m (6. 6 fee t) of each device and
is powered from an independent circuit breaker. As with any equipment, using a
filter or surge suppressor is recommended.
Ethernet Cabling
To ensure proper operation when i nstalli ng the switch int o a network, make sure that
the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T
operation. Check the following criteria against the current installation of your
network:
• Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables
with RJ-45 connectors; Category 3 or better for 10BASE-T, Category 5 or better
for 100BASE-TX, and Category 5, 5e or 6 for 1000BASE-T.
• Protection from radio frequency interference emissions
• Elect rical surge suppression
• Separat ion of electrical wires (switch related or other) and electromagnetic fields
from data based network wiring
• Safe connections with no damaged cables, connectors or shields
3-1
Installing the Switch
3
RJ-45 Connector
Figure 3-1 RJ-45 Connections
Equipment Checklist
After unpacking this switch, check the contents to be sure you have received all the
components. Then, before beginning the installation, be sure you have all other
necessary installation equipment.
Package Contents
• TigerSwitch 10/100, SMC6110L2
• Four adhesive foot pads
• Bracket Mounting Kit containing two brackets and eight screws for attaching the
brackets to the switch
• Power Cord—either US, Continental Europe or UK
• RS-232 console cable
• This Installation Guide
• Management Guide CD
Optional Rack-Mounting Equipment
If you plan to rack-mount the switch, be sure to have the following equipment
available:
• Fo ur mount ing s crews for each d evice you pl an to instal l i n a rac k—these are no t
included
• A screwdriver (Phillips or flathead, depending on the type of screws used)
3-2
Mounting
Mounting
The switch can be mounted in a standard 19-inch eq uipment rack or on a deskto p or
shelf. Mounting instructions for each type of site follow.
Rack Mounting
Before rack mounting the switch, pay particular attention to the following factors:
• Temperature: Since the temperature within a rack assembly may be higher than
the ambient room temperature, check that the rack-environment temperature is
within the specified operating temperature range. (See page C-1.)
• Mechanical Loading: Do not place any equipment on top of a rack-mounted unit.
• Circuit Overloading: Be sure that the supply circuit to the rack assembly is not
overloaded.
• Grounding: Rack-mounted equipment should be properly grounded. Particular
attention should be given to supply connections other than direct connections to
the mains.
To rack-mount devices:
1.Attach the brackets to the device using the screws provided in the Bracket
Mounting Kit.
3
Figure 3-2 Attaching the Brackets
3-3
Installing the Switch
3
2.Mount the device in the rack, using four rack-mounting screws (not provided).
Be sure to secure the lower rack-mounting screws first to prevent the bracket s
being bent by the weight of the switch.
Figure 3-3 Installing the Switch in a Rack
3.If installing a single switch only, turn to “Connecting to a Power Source” at the
end of this chapter.
4.If installing multiple switches, mount them in the rack, one below the other, in
any order.
3-4
Installing an Optional SFP Transceiver
Desktop or Shelf Mounting
1.Attach the four adhesive feet to the bottom of the first switch.
Figure 3-4 Attaching the Adhesive Feet
2.Set the device on a flat surface near an AC power source, making sure there
are at least two inches of space on all sides for proper air flow.
3.If installing a single switch only, go to “Connecting to a Power Source” at the
end of this chapter.
3
4.If installing multiple switches, atta ch four adhesive feet to ea ch one. Place each
device squarely on top of the one below, in any order.
Installing an Optional SFP Transceiver
Figure 3-5 Inserting an SFP Transceiver into a Slot
3-5
Installing the Switch
3
The SFP slots support the following optional SFP transceivers:
• 1000BASE-SX
• 1000BASE-LX
• 1000BASE-LH
To install an SFP transceiver, do the following:
1.Consider network and cabling requirements to select an appropriate SFP
transceiver type.
2.Insert the transceiver with the optical connector facing outward and the slot
connector facing down. Note that SFP transceivers are keyed so they can only
be installed in one orientation.
3.Slide the SFP transceiver into the slot until it clicks into place.
Note: SFP transceivers are hot-swappable. The switch does not need to be powered off
before installing or removing a transceiver. However, always first disconnect the
network cable before removing a transceiver.
Note: SFP transceivers are not provided in the switch package.
Connecting to a Power Source
To connect a switch to a power source:
1.Insert the power cable plug directly into the AC socket located at t he back of the
switch.
Figure 3-6 Power Socket
2.Plug the other end of the cable into a grounded, three-pin, AC power source.
Note: For International use, you may need to change the AC line cord. You must
use a line cord set that has been approved for the receptacle type in your
country.
3.Check the front-panel LEDs as the device is powered on to be su re the Power
LED is lit. If not, check that the power cable is correctly plugged in.
3-6
Connecting to the Console Port
Connecting to the Console Port
The DB-9 serial port on the switch’s back panel is used to connect to the switch for
out-of-band console configuration. The command-line-driven configuration program
can be accessed from a terminal or a PC runni ng a terminal emul ation progra m. The
pin assignments used to connect to the serial port are p rovided in the fol lowing t able.
3
1
5
69
Figure 3-7 Serial Port (DB-9 DTE) Pin-Out
Wiring Map for Serial Cable
Table 3-1 Serial Cable Wiring
Switch’s 9-Pin
Serial Port
2 RXD (receive data)<---------------------------- 3 TXD (transmi t data)
3 TXD (transmit data)-----------------------------> 2 RXD (receive data)
5 SGND (signal ground) ------------------------------ 5 SGND (signal ground)
No other pins are used.
The serial port’s configuration requirements are as follows:
• Default Baud rate—9,600 bps
• Character Size—8 Characters
• Parity—None
• Stop bit—One
• Data b its—8
• Flow cont rol—none
Null ModemPC’s 9-Pin
DTE Port
3-7
Installing the Switch
3
3-8
Chapter 4: Making Network Connections
Connecting Network Devices
The switch is designed to be connected to 10 or 100 Mbps network cards in PCs and
servers, as well as to other switches and hubs. It may also be connected to remote
devices using optional 1000BASE-SX, 1000BASE-LX, or 1000BASE-LH SFP
transceivers.
Twisted-Pair Devices
Each device requires an unshielded twisted-pair (UTP) cable with RJ-45 connectors
at both ends. Use Category 5, 5e or 6 cable for 1 000BASE-T connections, Category
5 or better for 100BASE-TX connections, and Category 3 or better for 10BASE-T
connections.
Cabling Guidelines
The RJ-45 ports on the switch support automatic MDI/ MDI-X pinout confi guration, so
you can use standard straight-through twisted-pair cables to connect to any other
network device (PCs, servers, switches, routers, or hubs).
See Appendix B for further information on cabling.
Caution: Do not plug a phone jack connector into an RJ-45 port. This will damage the
switch. Use only twisted-pair cables with RJ-45 connectors that conform to
FCC standards.
4-1
Making Network Connections
4
Connecting to PCs, Servers, Hubs and Switches
1.Attach one end of a twisted-pair cable segment to the device’s RJ-45
connector.
Figure 4-1 Making Twisted-Pair Connections
2.If the device is a network card and the switch is in the wiring closet, attach the
other end of the cable segment to a mo dular wall outl et that is con nected to th e
wiring closet. (See the section “Network Wiring Connections.”) Otherwise,
attach the other end to an available port on the switch.
Make sure each twisted pair cable does not exceed 100 meters (328 ft) in
length.
Note: Avoid using flow control on a port connected to a hub unless it is actually required
to solve a problem. Otherwise back pressure jamming signals may degrade
overall performance for the segment attached to the hub.
3.As each connection is made, the Link LED (on the switch) corresponding to
each port will light green (1000 Mbps) or amber (10/100 Mbps) to indicate that
the connection is valid.
Network Wiring Connections
Today, the punch-down block is an integral part of many of the newer equipment
racks. It is actually part of the patch p anel. Instructions f or making connections in the
wiring closet with this type of equipment follows.
1.Attach one end of a patch cable to an available port on the switch, and the other
end to the patch panel.
2.If not already in place, attach one end of a cable segment to the back of the
patch panel where the punch-down block is located, and the other end to a
modular wall outlet.
4-2
Twisted-Pair Devices
3.Label the cables to simplify future troubleshooting. See “Cable Labeling and
Connection Records” on page 4-7.
4
Switch
Patch Panel
Figure 4-2 Network Wiring Connections
Equipment Rack
(side view)
Punch-Down Block
Wall
4-3
Making Network Connections
4
Fiber Optic SFP Devices
An optional Gigabit SFP transceiver (1000BASE-SX, 1000BASE-LX or
1000BASE-LH) can be used for a backbone connection between switches, or for
connecting to a high-speed server.
Each single-mode fiber port requires 9/125 micron single-mode fi ber optic cable with
an LC connector at both ends. Each multimode fiber optic port requires 50/125 or
62.5/125 micron multimode fiber optic cabling with an LC connector at both ends.
Warning:This switch uses lasers to transmit signals over fiber optic cable. The lasers are
Warning:When selecting a fiber SFP device, considering safety, please make sure that it
compliant with the requirements of a Class 1 Laser Product and are inherently
eye safe in normal operation. However, you should never look directly at a
transmit port when it is powered on.
can function at a temperature that is not less than the recommended maximum
operational temperature of the product. You must also use an approved Laser
Class 1 SFP transceiver.
Hinweis: Bei der Wahl eines Glasfasertransceivers muß für die Beurteilung der
1.Remove and keep the LC port’s rubber plug. When not connected to a fiber
2.Check that the fiber terminators are clean. You can clean the cable plugs by
3.Connect one end of the cable to the LC port on the switch and the other end to
Gesamtsicherheit beachtet werden, das die maximale Umgebungstemperatur
des Transceivers für den Betrieb nicht niedriger ist als die für dieses Produkts.
Der Glasfasertransceiver muß auch ein überprüftes Gerät der Laser Klasse 1
sein.
cable, the rubber plug should be replaced to protect the optics.
wiping them gently with a clean tissue or cotton ball moistened with a little
ethanol. Dirty fiber terminators on fiber optic cab les wil l imp a ir t he qualit y o f the
light transmitted through the cable and lead to degraded performance on the
port.
the LC port on the other device. Since LC connectors are keyed, the cable can
be attached in only one orientation.
4-4
Connectivity Rules
46
Figure 4-3 Making Fiber Port Connections
4.As a connection is made, check the Link LED on the switch corresponding to
the port to be sure that the connection is valid.
The 1000BASE-SX, 1000BASE-LX, 1000BASE-LH fiber optic ports operate at
1 Gbps, full duplex, with auto-negotiation of flow control. The maximum length for
fiber optic cable operating at Gigabit speed will depend on t he fiber type as listed
under “1000 Mbps Gigabit Ethernet Collision Domain” on page 4-6.
Connectivity Rules
4
When adding hubs (repeaters) to your network, please follow the connectivity rules
listed in the manuals for these products. However, note that because switches break
up the path for connected devices into separate collision domains, you should not
include the switch or connected cabling in your calculations for cascade length
involving other devices.
1000BASE-T Cable Requirements
All Category 5 UTP cables that are used for 100BASE-TX connections should also
work for 1000BASE-T, providing that all four wire pairs are connected. Howev er, it is
recommended that for all critical connections, or any new cable ins tallations,
Category 5e (enhanced Category 5) or Category 6 cable should be used. The
Category 5e and 6 specifications include test parameters that are only
recommendations for Category 5. Therefore, the first step in preparing existing
Category 5 cabling for running 1000BASE-T is a simple test of the cable installation
to be sure that it complies with the IEEE 802.3-2005 standards.
4-5
Making Network Connections
4
1000 Mbps Gigabit Ethernet Collision Domain
Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length
Cable TypeMaximum Cable LengthConnector
Category 5, 5e, or 6 100-ohm UTP or STP 100 m (328 ft)RJ-45
Table 4-2 Maximum 1000BASE-SX Gigabit Ethernet Cable Lengths
160 MHz/km2-220 m (7-722 ft)LC
200 MHz/km2-275 m (7-902 ft)LC
400 MHz/km2-500 m (7-1641 ft)LC
500 MHz/km2-550 m (7-1805 ft)LC
N/A2 m - 5 km (7 ft - 3.2 miles) LC
N/A2 m - 70 km
(7 ft -43.5 miles)
LC
100 Mbps Fast Ethernet Collision Domain
Table 4-5 Maximum Fast Ethernet Cable Lengths
TypeCable TypeMax. Cable Length Connector
100BASE-TX Category 5 or better 100-ohm UTP or STP 100 m (328 ft)RJ-45
10 Mbps Ethernet Collision Domain
Table 4-6 Maximum Ethernet Cable Length
TypeCable TypeMax. Cable Length Connector
10BASE-TCategory 3 or better 100-ohm UTP100 m (328 ft)RJ-45
4-6
Cable Labeling and Connection Records
Cable Labeling and Connection Records
When planning a network installation, it is essential to label the opposing ends of
cables and to record where each cable is connected. Doing so will enable you to
easily locate inter-connected devices, isolate faults and change your topology
without need for unnecessary time consumption.
To best manage the physical implementations of your network, follow these
guidelines:
• Clearly label the opposing ends of each cable.
• Using your building’s floor plans, draw a map of the location of all
network-connected equipment. For each piece of equipme nt, identi fy the dev ices
to which it is connected.
• Note the length of each cable and the maximum cable length supported by the
switch ports.
• For ease of understanding, use a location-based key when assigning prefi xes to
your cable labeling.
• Use sequential numbers for cables that originate from the same equipment.
• Differentiate between racks by naming accordingly.
• Label each separate piece of equipment.
• Displa y a copy of your equipment map, including keys to a ll abbreviations at ea ch
equipment rack.
4
4-7
Making Network Connections
4
4-8
Appendix A: Troubleshooting
Diagnosing Switch Indicators
Table A-1 Troubleshooting Chart
SymptomAction
Power LED is Off• Check connections between the switch, the power cord and the wall outlet.
• Contact your dealer for assistance.
Diag LED is Amber• Power cycle the switch to try and clear the condition.
• If the condition does not clear, contact your dealer for assistance.
Link LED is Off• Verify that the switch and attached device are powered on.
• Be sure the cable is plugged into both the swit ch and corresponding device.
• If the switch is installed in a rack, check the connections to the punch-down
block and patch panel.
• Verify that the proper cable type is used and its length does not exceed
specified limits.
• Check the adapter on the attached device and cable connections for
possible defects. Replace the defective adapter or cable if necess ary.
Power and Cooling Problems
If the power indicator does not turn on when the power cord is plugged in, you may
have a problem with the power outlet, power cord, or internal power supply.
However, if the unit powers off after running for a while, check for loose power
connections, power losses or surges at the power outlet. If you still cannot isolate
the problem, the internal power supply may be defective.
Installation
Verify that all system components have been properly installed. If one or more
components appear to be malfunctioning (such as the power cord or network
cabling), test them in an alternate environment where you are sure that all the other
components are functioning properly.
A-1
A
Troubleshooting
In-Band Access
You can access the management agent in the switch from anywhere within the
attached network using Telnet, a web browser, or other network management
software tools. However, you must first configure the switch with a valid IP address,
subnet mask, and default gateway. If you have trouble establishing a link to the
management agent, check to see if you have a valid network connection. Then
verify that you entered the correct IP address. Also, be sure the port through which
you are connecting to the switch has not been disabled. If it has not been disabled,
then check the network cabling that runs between your remote location and the
switch.
Note: The management agent accepts up to four simultaneous Telnet sessions. If the
maximum number of sessions already exists, an additional Telnet connection will
not be able to log into the system.
A-2
Appendix B: Cables
Twisted-Pair Cable and Pin Assignments
For 10/100BASE-TX connections, the twisted-pair cable must have two pairs of
wires. For 1000BASE-T connections the twisted-pair cable must have four pairs of
wires. Each wire pair is identified by two different colors. For example, one wire
might be green and the other, green with white stripes. Also, an RJ-45 connector
must be attached to both ends of the cable.
Caution:DO NOT plug a phone jack connector into any RJ-45 port. Use only
twisted-pair cables with RJ-45 connectors that conform with FCC standards.
Caution:Each wire pair must be attached to the RJ-45 connectors in a specific
The figure below illustrates how the pins on the RJ-45 connector are numbered. Be
sure to hold the connectors in the same orientation when attaching the wires to the
pins.
orientation.
8
1
Figure B-1 RJ-45 Connector Pin Numbers
8
1
10BASE-T/100BASE-TX Pin Assignments
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45
connections: 100-ohm Category 3 or better cable for 10 Mbps connections, or
100-ohm Category 5 or better cable for 100 Mbps conn ections. Also be sure
length of any twisted-pair connection does not exceed 100 meters (328 feet).
The RJ-45 ports on the switch base unit suppo rt automati c MDI/MDI-X operation , so
you can use straight-through cables for all network connections t o PCs or servers, or
to other switches or hubs. In straight-throu gh cable, pins 1, 2, 3, and 6, at o ne end of
the cable, are connected straight through to pins 1, 2, 3, and 6 at the other end of
the cable. When using any RJ-45 port on this switch, you can use either
straight-through or crossover cable.
that the
B-1
B
Cables
Table B-1 10/100BASE-TX MDI and MDI-X Port Pinouts
PinMDI Signal NameMDI-X Signal Name
1Transmit Data plus (TD+)Receive Data plus (RD+)
2Transmit Data minus (TD-)Receive Data minus (RD-)
3
6
4,5,7,8
Receive Data plus (RD+)Transmit Data plus (TD+)
Receive Data minus (RD-)Transmit Data minus (TD-)
Not usedNot used
Note: The “+” and “-” signs represent the polarity of the wires that make
up each wire pair.
Straight-Through Wiring
If the twisted-pair cable is to join two ports and only one of the ports has an internal
crossover (MDI-X), the two pairs of wires must be straight-through. (When
auto-negotiation is enabled for any RJ-45 port on this switch, you can use either
straight-through or crossover cable to connect to any device type.)
You must connect all four wire pairs as shown in the following diagram to support
Gigabit Ethernet.
EIA/TIA 568B RJ-45 Wiring Standard
10/100BASE-TX Straight-through Cable
B-2
End A
White/Orange Stripe
Orange
1
2
3
4
5
6
7
8
White/Green Stripe
Blue
White/Blue Stripe
Green
White/Brown Stripe
Brown
1
2
3
4
5
6
7
8
End B
Figure B-2 Straight-through Wiring
Twisted-Pair Cable and Pin Assignments
B
Crossover Wiring
If the twisted-pair cable is to join two por ts and either both ports are labeled with an
“X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover must be
implemented in the wiring. (When auto-negotiation is enabled for any RJ-45 port on
this switch, you can use either straight-throug h o r crossover ca ble t o conne ct to any
device type.)
You must connect all four wire pairs as shown in the following diagram to support
Gigabit Ethernet.
EIA/TIA 568B RJ-45 Wiring Standard
10/100BASE-TX Crossover Cable
White/Orange Stripe
Orange
End A
1
2
3
4
5
6
7
8
White/Green Stripe
Blue
White/Blue Stripe
Green
White/Brown Stripe
Brown
Figure B-3 Crossover Wiring
1
2
3
4
5
6
7
8
End B
1000BASE-T Pin Assignments
All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use
straight-through cables for all network connections to PCs or servers, or to other
switches or hubs.
The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports
require that all four pairs of wires be connected. Note that for 1000BASE-T
operation, all four pairs of wires are used for both transmit and receive.
Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or shielded
twisted-pair (STP) cable for 1000BASE-T connections. Also be sure
of any twisted-pair connection does not exceed 100 meters (328 feet)
Table B-2 1000BASE-T MDI and MDI-X Port Pinouts
PinMDI Signal NameMDI-X Signal Name
1Bi-directional Data One Plus (BI_D1+)Bi-directional Data Two Plus (BI_D2+)
2Bi-directional Data One Minus (BI_D1-)Bi-directional Data Two Minus (BI_D2-)
3Bi-directional Data Two Plus (BI_D2+)Bi-directional Data One Plus (BI_D1+)
4Bi-directional Data Three Plus (BI_D3+)Bi-directional Data Four Plus (BI_D4+)
that the length
.
B-3
B
Cables
Table B-2 1000BASE-T MDI and MDI-X Port Pinouts
PinMDI Signal NameMDI-X Signal Name
5Bi-directional Data Three Minus (BI_D3-)Bi-directional Data Four Minus (BI_D4-)
6Bi-directional Data Two Minus (BI_D2-)Bi-directional Data One Minus (BI_D1-)
7Bi-directional Data Four Plus (BI_D4+)Bi-directional Data Three Plus (BI_D3+)
8Bi-directional Data Four Minus (BI_D4-)Bi-directional Data Three Minus (BI_D3-)
Cable Testing for Existing Category 5 Cable
Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk
(NEXT), and Far-End Crosstalk (FEXT). This cable testing information is spec ified in
the ANSI/TIA/EIA-TSB-67 standard. Additionally, cables must also pass test
parameters for Return Loss and Equal-Level Far-End Crosstalk (ELFEXT). These
tests are specified in the ANSI/TIA/EIA-TSB-95 Bulletin, “The Additional
Transmission Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.”
Note that when testing your cable installation, be sure to include all patch cables
between switches and end devices.
Adjusting Existing Category 5 Cabling to Run 1000BASE-T
If your existing Category 5 installation does not meet one of the test parameters for
1000BASE-T, there are basically three measures that can be applied to try and
correct the problem:
1.Replace any Category 5 patch cables with high-performance Category 5e or
Category 6 cables.
2.Reduce the number of connectors used in the link.
3.Reconnect some of the connectors in the link.
Fiber Standards
The current TIA (Telecommunications Industry Association) 568-A specification on
optical fiber cabling consists of o ne recognized cable typ e for horizont al subsys tems
and two cable types for backbone subsystems.
Horizontal 62.5/125 micron multimode (two fibers per outlet).
Backbone 62.5/125 micron multimode or single-mode.
TIA 568-B will allow the use of 50/125 micron multimode optical fiber in both the
horizontal and backbone in addition to the types listed above. All optical fiber
components and installation practices must meet applicable building and safety
codes.
B-4
Appendix C: Specifications
Physical Characteristics
Ports
8 10/100BASE-TX, with auto-negotiation
2 10/100/1000BASE-T shared with two SFP transceiver slots
Network Interface
Ports 1-10: RJ-45 connector, auto MDI/X
10BASE-T: RJ-45 (100-ohm, UTP cable; Category 3 or better)
100BASE-TX: RJ-45 (100-ohm, UTP cable; Category 5 or better)
1000BASE-T: RJ-45 (100-ohm, UTP or STP cable; Category 5, 5e or 6)
*Maximum Cable Length - 100 m (328 ft)
Buffer Architecture
2 Mbits
Aggregate Bandwidth
5.6 Gbps
Switching Database
8K MAC address entries
LEDs
System: Power, Diag (Diagnostic),
Port:
status (link, speed, and activity)
Weight
1.8 kg (3.97 lbs)
Size
33.0 x 20.4 x 4.3 cm (12.99 x 8.03 x 1.73 in.)
Temperature
Operating: 0°C to 50°C (32°F to 122°F)
Storage: -40°C to 70°C (-40°F to 158°F)
Humidity
Operating: 10% to 90% (non-condensing)
C-1
C
Specifications
AC Input
100 to 240 V, 50-60 Hz, 0.4A
Power Supply
Internal, auto-ranging transformer: 100 to 240 VAC, 50 to 60 Hz
Power Consumption
13.2 Watts maximum
Maximum Current
0.4 A @ 100 VAC
0.2 A @ 240 VAC
Switch Features
Forwarding Mode
Store-and-forward
Throughput
Wire speed
Flow Control
Full Duplex: IEEE 802.3x
Half Duplex: Back pressure
Management Features
In-Band Management
SSH, Telnet, SNMP, or HTTP
Out-of-Band Management
RS-232 DB-9 console port
Software Loading
TFTP in-band, or XModem out-of-band
C-2
Standards
IEEE 802.3-2005
Ethernet, Fast Ethernet, Gigabit Ethernet
Full-duplex flow control
Link Aggregation Control Protocol
IEEE 802.1D Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Protocol
ISO/IEC 8802-3
Compliances
Emissions
Industry Canada Class A
EN55022 (CISPR 22) Class A
EN 61000-3-2/3
FCC Class A
VCCI Class A
CE Mark
MIC Class A (Republic of Korea Only)
Immunity
EN 61000-4-2/3/4/5/6/8/11
Standards
C
Safety
UL 60950-1 & CSA 60950-1
IEC 60950-1 & EN 60950-1
C-3
C
Specifications
C-4
Appendix D: Ordering Information
Table D-1 TIgerSwitch 10/100 Products and Accessories
Product NumberDescription
SMC6110L2
SMC1GSFP-SX
SMC1GSFP-LX
SMC1GSFP-ZXSingle-port 1000BASE-ZX Small Form Pluggable (SFP)
8-port 10/100 Managed Switch with 2 Gigabit Combo ports
Single-port 1000BASE-SX Small Form Pluggable (SFP)
mini-GBIC transceiver
Single-port 1000BASE-LX Small Form Pluggable (SFP)
mini-GBIC transceiver
mini-GBIC transceiver
D-1
D
Ordering Information
D-2
Glossary
10BASE-T
IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or 5
UTP cable.
100BASE-FX
IEEE 802.3 specification for 100 Mbps Ethernet over two strands of 50/125, 62.5/
125 micron, or 9/125 micron core fiber cable.
100BASE-TX
IEEE 802.3u specification for 100 Mbps Ethernet over two pairs of Category 5 UTP
cable.
1000BASE-LX
IEEE 802.3z specification for Gigabit Ethernet over two stran ds of 50/125, 62.5/125
or 9/125 micron core fiber cable.
1000BASE-LH
Specification for long-haul Gigabit Ethernet over two strands of 9/125 micron core
fiber cable.
1000BASE-SX
IEEE 802.3z specification for Gigabit Ethernet over two strands of 50/125 or
62.5/125 micron core fiber cable.
1000BASE-T
IEEE 802.3ab specification for Gigabit Ethernet over 100-ohm Category 5, 5e or 6
twisted-pair cable (using all four wire pairs).
Auto-Negotiation
Signalling method allowing each node to select its optimum operational mode (e.g.,
speed and duplex mode) based on the capabilities of the node to which it is
connected.
Bandwidth
The difference between the highest and lowest frequencies available for network
signals. Also synonymous with wire speed, the actual speed of the data
transmission along the cable.
Glossary-1
Glossary
Collision
A condition in which packets transmitted over the cable interfere
Their interference makes both signals unintelligible.
with each other.
Collision Domain
Single CSMA/CD LAN segment.
CSMA/CD
CSMA/CD (Carrier Sense Multiple Access/Collision Detect) is the communication
method employed by Ethernet, Fast Ethernet, and Gigabit Ethernet.
End Station
A workstation, server, or other device that does not forward traffic.
Ethernet
A network communication system developed and standardized by DEC, Intel, and
Xerox, using baseband transmission, CSMA/CD access, logical bus topology, and
coaxial cable. The successor IEEE 802.3 standard provides for int egration into the
OSI model and extends the physical layer and media with repeaters and
implementations that operate on fiber, thin coa x a nd twisted-pair cable.
Fast Ethernet
A 100 Mbps network communication system based on Ethernet and the CSMA/CD
access method.
Full Duplex
Transmission method that allows two network devices to transmit and receive
concurrently, effectively doubling the band width of that link.
Gigabit Ethernet
A 1000 Mbps network communication system based on Ethernet and the CSMA/CD
access method.
IEEE
Institute of Electrical and Electronic Engineers.
IEEE 802.3
Defines carrier sense multiple access with collision detection (CSMA/CD) access
method and physical layer specifications.
IEEE 802.3ab
Defines CSMA/CD access method and physical layer specifications for
1000BASE-T Gigabit Ethernet. (Now incorporated in IEEE 802.3-2002.)
Glossary-2
Glossary
IEEE 802.3u
Defines CSMA/CD access method and physical layer specifications for
100BASE-TX Fast Ethernet. (Now incorporated in IEEE 802.3-2002.)
IEEE 802.3x
Defines Ethernet frame start/stop requests and timers used for flow control on
full-duplex links. (Now incorporated in IEEE 802.3-2002.)
IEEE 802.3z
Defines CSMA/CD access method and physical layer specifications for 1000BASE
Gigabit Ethernet. (Now incorporated in IEEE 802.3-2002.)
LAN Segment
Separate LAN or collision domain.
LED
Light emitting diode used for monitoring a device or network condition.
Local Area Network (LAN)
A group of interconnected computer and support devices.
Media Access Control (MAC)
A portion of the networking protocol that governs access to the transmission
medium, facilitating the exchange of data between network nodes.
MIB
An acronym for Management Information Base. It is a set of database objects that
contains information about the device.
Modal Bandwidth
Bandwidth for multimode fiber is referred to as modal bandwidth because it varies
with the modal field (or core diameter) of the fiber. Modal bandwidth is specified in
units of MHz per km, which indicates the amoun t of bandwid th supported by t he fiber
for a one km distance.
Network Diameter
Wire distance between two end stations in the same collision domain.
Redundant Power Supply (RPS)
A backup power supply unit that automatically takes over in case the primary po wer
supply should fail.
Glossary-3
Glossary
RJ-45 Connector
A connector for twisted-pair wiring.
Switched Ports
Ports that are on separate collision domains or LAN segments.
TIA
Telecommunications Industry Association
Transmission Control Protocol/Internet Protocol (TCP/IP)
Protocol suite that includes TCP as the primary transport protocol, and IP as the
network layer protocol.
UTP
Unshielded twisted-pair cable.
Virtual LAN (VLAN)
A Virtual LAN is a collection of network nodes that share the same collision domain
regardless of their physical location or connection point in the network. A VLAN
serves as a logical workgroup with no physical barriers, allowing users to share
information and resources as though located on the same LAN.