SMC Networks SMC2552W-G2, SMC2552W-G2-17 User Manual

EliteConnect™ SMC2552W-G2
2.4GHz Wireless Access Point
The easy way to make all your network connections
38 Tesla Irvine, CA 92618 Phone: (949) 679-8000
Copyright
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice.
Copyright © 2006 by
SMC Networks, Inc.
38 Tesla
Irvine, CA 92618
All rights reserved.
Trademarks:
SMC is a registered trademark; and EliteConnect is a trademark of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders.
COMPLIANCES
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
IMPORTANT NOTE: FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters (8 inches) between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Industry Canada - Class B
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of Industry Canada.
Cet appareil numérique respecte les limites de bruits radioélectriques applicables
i
COMPLIANCES
aux appareils numériques de Classe B prescrites dans la norme sur le matérial brouilleur: “Appareils Numériques,” NMB-003 édictée par l’Industrie.
Japan VCCI Class B
Australia/New Zealand AS/NZS 4771
ACN 066 352010
EC Conformance Declaration
Marking by the above symbol indicates compliance with the Essential Requirements of the R&TTE Directive of the European Union (1999/5/ EC). This equipment meets the following conformance standards:
• EN 60950-1 (IEC 60950-1) - Product Safety
• EN 300 328 - Technical requirements for 2.4 GHz radio equipment
• EN 301 489-1 / EN 301 489-17 - EMC requirements for radio equipment
Countries of Operation & Conditions of Use in the European Community
This device is intended to be operated in all countries of the European Community. Requirements for indoor vs. outdoor operation, license requirements and allowed channels of operation apply in some countries as described below:
Note: The user must use the configuration utility provided with this
product to ensure the channels of operation are in conformance with the spectrum usage rules for European Community countries as described below.
• This device requires that the user or installer properly enter the current country of operation in the command line interface as described in the user guide, before operating this device.
ii
C
OMPLIANCES
• This device will automatically limit the allowable channels determined
by the current country of operation. Incorrectly entering the country of operation may result in illegal operation and may cause harmful interference to other systems. The user is obligated to ensure the device is operating according to the channel limitations, indoor/outdoor restrictions and license requirements for each European Community country as described in this document.
• This device may be operated indoors or outdoors in all countries of the
European Community using the 2.4 GHz band: Channels 1 - 13, except where noted below.
- In Italy the end-user must apply for a license from the national spectrum authority to operate this device outdoors.
- In Belgium outdoor operation is only permitted using the 2.46 -
2.4835 GHz band: Channel 13.
- In France outdoor operation is only permitted using the 2.4 - 2.454 GHz band: Channels 1 - 7.
iii
COMPLIANCES
Declaration of Conformity in Languages of the European Community
English Hereby, SMC, declares that this Radio LAN device is in
Finnish Valmistaja SMC vakuuttaa täten että Radio LAN device tyyppinen
Dutch Hierbij verklaart SMC dat het toestel Radio LAN device in
French Par la présente SMC déclare que l'appareil Radio LAN device est
Swedish Härmed intygar SMC att denna Radio LAN device står I
Danish Undertegnede SMC erklærer herved, at følgende udstyr Radio
German Hiermit erklärt SMC, dass sich dieser/diese/dieses Radio LAN
Greek με την παρουσα SMC δηλωνει οτι radio LAN device
Italian Con la presente SMC dichiara che questo Radio LAN device è
compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG
Bij deze SMC dat deze Radio LAN device voldoet aan de essentiële eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC.
conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE
överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.
LAN device overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF
device in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet". (BMWi)
Hiermit erklärt SMC die Übereinstimmung des Gerätes Radio LAN device mit den grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie 1999/5/EG. (Wien)
συμμορφωνεται προσ τισ ουσιωδεισ απαιτησεισ και τισ λοιπεσ σΧετικεσ διαταξεισ τησ οδηγιασ 1999/5/εκ
conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
iv
C
OMPLIANCES
Spanish Por medio de la presente Manufacturer declara que el Radio LAN
Portuguese Manufacturer declara que este Radio LAN device está conforme
device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE
com os requisitos essenciais e outras disposições da Directiva 1999/5/CE.
Safety Compliance
Power Cord Safety
Please read the following safety information carefully before installing the access point:
WARNING: Installation and removal of the unit must be carried out by qualified personnel only.
• The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.
• Do not connect the unit to an A.C. outlet (power supply) without an earth (ground) connection.
• The appliance coupler (the connector to the unit and not the wall plug) must have
a configuration for mating with an EN 60320/IEC 320 appliance inlet.
• The socket outlet must be near to the unit and easily accessible. You can only
remove power from the unit by disconnecting the power cord from the outlet.
• This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions.
• The PoE (Power over Ethernet), which is to be interconnected with other equipment that must be contained within the same building including the interconnected equipment’s associated LAN connections.
France and Peru only
This unit cannot be powered from IT unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth (ground).
Impédance à la terre
supplies. If your supplies are of IT type, this
v
COMPLIANCES
Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following:
Power Cord Set
U.S.A. and Canada
Denmark The supply plug must comply with Section 107-2-D1,
Switzerland The supply plug must comply with SEV/ASE 1011.
U.K. The supply plug must comply with BS1363 (3-pin 13 A) and
Europe The supply plug must comply with CEE7/7 (“SCHUKO”).
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A
The attachment plug must be an earth-grounding type with NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.
Standard DK2-1a or DK2-5a.
be fitted with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (minimum).
The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (minimum).
IEC-320 receptacle.
vi
C
OMPLIANCES
Veuillez lire à fond l'information de la sécurité suivante avant d'installer le access point:
AVERTISSEMENT: L’installation et la dépose de ce groupe doivent être confiés à un
personnel qualifié.
• Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).
• Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse) afin de respecter les normes internationales de sécurité.
• Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale) doit respecter une configuration qui permet un branchement sur une entrée d’appareil EN 60320/IEC 320.
• La prise secteur doit se trouver à proximité de l’appareil et son accès doit être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant son cordon électrique au niveau de cette prise.
• L’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec raccordement direct à la terre (masse).
Cordon électrique - Il doit être agréé dans le pays d’utilisation
Etats-Unis et Canada:
Danemark: La prise mâle d’alimentation doit respecter la section 107-2
Le cordon doit avoir reçu l’homologation des UL et un certificat de la CSA.
Les spécifications minimales pour un cable flexible sont AWG No. 18, ou AWG No. 16 pour un cable de longueur inférieure à 2 mètres.
- type SV ou SJ
- 3 conducteurs
Le cordon doit être en mesure d’acheminer un courant nominal d’au moins 10 A.
La prise femelle de branchement doit être du type à mise à la terre (mise à la masse) et respecter la configuration NEMA 5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V).
D1 de la norme DK2 1a ou DK2 5a.
vii
COMPLIANCES
Cordon électrique - Il doit être agréé dans le pays d’utilisation
Suisse: La prise mâle d’alimentation doit respecter la norme SEV/
Europe La prise secteur doit être conforme aux normes CEE 7/7
Bitte unbedingt vor dem Einbauen des Access Point die folgenden Sicherheitsanweisungen durchlesen
WARNUNG: Die Installation und der Ausbau des Geräts darf nur durch
Fachpersonal erfolgen.
• Das Gerät sollte nicht an eine ungeerdete Wechselstromsteckdose angeschlossen werden.
• Das Gerät muß an eine geerdete Steckdose angeschlossen werden, welche die internationalen Sicherheitsnormen erfüllt.
• Der Gerätestecker (der Anschluß an das Gerät, nicht der Wandsteckdosenstecker) muß einen gemäß EN 60320/IEC 320 konfigurierten Geräteeingang haben.
• Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.
• Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen (Sicherheitskleinstspannung) gemäß IEC 60950. Diese Bedingungen sind nur gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter
SELV-Bedingungen betrieben werden.
ASE 1011.
(“SCHUKO”) LE cordon secteur doit porter la mention <HAR> ou
<BASEC> et doit être de type HO3VVF3GO.75 (minimum).
(Germany):
viii
C
OMPLIANCES
Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft werden:
U.S.A und Kanada
Danemark Dieser Stromstecker muß die ebene 107-2-D1, der
Schweiz Dieser Stromstecker muß die SEV/ASE
Europe Das Netzkabel muß vom Typ HO3VVF3GO.75
Der Cord muß das UL gepruft und war das CSA beglaubigt.
Das Minimum spezifikation fur der Cord sind:
- Nu. 18 AWG - nicht mehr als 2 meter, oder 16 AWG.
- Der typ SV oder SJ
- 3-Leiter
Der Cord muß haben eine strombelastbarkeit aus wenigstens 10 A
Dieser Stromstecker muß hat einer erdschluss mit der typ NEMA 5-15P (15A, 125V) oder NEMA 6-15P (15A, 250V) konfiguration.
standard DK2-1a oder DK2-5a Bestimmungen einhalten.
1011Bestimmungen einhalten.
(Mindestanforderung) sein und die Aufschrift <HAR> oder <BASEC> tragen.
Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).
ix
COMPLIANCES
x
Table of Contents

Chapter 1: Introduction 1-1

Package Checklist 1-2 Hardware Description 1-2
Component Description 1-3 Features and Benefits 1-5 System Defaults 1-6
Chapter 2: Hardware Installation 2-1
Chapter 3: External Antennas 3-1
Installation Procedures 3-1
Chapter 4: Network Configuration 4-1
Network Topologies 4-2
Ad Hoc Wireless LAN (no Access Point) 4-2
Infrastructure Wireless LAN 4-3
Infrastructure Wireless LAN for Roaming Wireless PCs 4-4
Infrastructure Wireless Bridge 4-5
Infrastructure Wireless Repeater 4-6
Chapter 5: Initial Configuration 5-1
Initial Setup through the CLI 5-1
Required Connections 5-1
Initial Configuration Steps 5-2 Logging In 5-3
Chapter 6: System Configuration 6-1
Advanced Configuration 6-2
System Identification 6-3
TCP / IP Settings 6-5
RADIUS 6-7
SSH Settings 6-11
Authentication 6-12
Filter Control 6-17
xi
Contents
VLAN 6-19 WDS Settings 6-21 AP Management 6-27 Administration 6-28 System Log 6-32
SNMP 6-36
Configuring SNMP and Trap Message Parameters 6-37 Configuring SNMPv3 Users 6-42 Configuring SNMPv3 Trap Filters 6-44 Configuring SNMPv3 Targets 6-46
Radio Interface 6-48
Security 6-63
Status Information 6-83
Access Point Status 6-83 Station Status 6-86 Event Logs 6-89
Chapter 7: Command Line Interface 7-1
Using the Command Line Interface 7-1
Accessing the CLI 7-1 Console Connection 7-1 Telnet Connection 7-1
Entering Commands 7-2
Keywords and Arguments 7-2 Minimum Abbreviation 7-2 Command Completion 7-3 Getting Help on Commands 7-3 Partial Keyword Lookup 7-4 Negating the Effect of Commands 7-4 Using Command History 7-4 Understanding Command Modes 7-4 Exec Commands 7-5 Configuration Commands 7-5 Command Line Processing 7-6
Command Groups 7-6 General Commands 7-7
configure 7-8 end 7-8 exit 7-8 ping 7-9 reset 7-10 show history 7-10 show line 7-11
System Management Commands 7-11
xii
Contents
country 7-12
prompt 7-14
system name 7-14
username 7-15
password 7-15
ip ssh-server enable 7-16
ip ssh-server port 7-16
ip telnet-server enable 7-17
ip http port 7-17
ip http server 7-18
ip https port 7-18
ip https server 7-19
web-redirect 7-20
APmgmtIP 7-21
APmgmtUI 7-22
show apmagement 7-22
show system 7-23
show version 7-24
show config 7-24
show hardware 7-28 System Logging Commands 7-28
logging on 7-29
logging host 7-29
logging console 7-30
logging level 7-30
logging facility-type 7-31
logging clear 7-32
show logging 7-32
show event-log 7-33 System Clock Commands 7-33
sntp-server ip 7-34
sntp-server enable 7-34
sntp-server date-time 7-35
sntp-server daylight-saving 7-36
sntp-server timezone 7-36
show sntp 7-37 DHCP Relay Commands 7-38
dhcp-relay enable 7-38
dhcp-relay 7-39
show dhcp-relay 7-39 SNMP Commands 7-40
snmp-server community 7-41
snmp-server contact 7-41
snmp-server location 7-42
snmp-server enable server 7-42
xiii
Contents
snmp-server host 7-43 snmp-server trap 7-44 snmp-server engine-id 7-46 snmp-server user 7-46 snmp-server targets 7-48 snmp-server filter 7-49 snmp-server filter-assignments 7-50 show snmp groups 7-50 show snmp users 7-51 show snmp group-assignments 7-51 show snmp target 7-52 show snmp filter 7-52 show snmp filter-assignments 7-53 show snmp 7-54
Flash/File Commands 7-55
bootfile 7-55 copy 7-56 delete 7-57 dir 7-58 show bootfile 7-58
RADIUS Client 7-59
radius-server address 7-59 radius-server port 7-60 radius-server key 7-60 radius-server retransmit 7-61 radius-server timeout 7-61 radius-server port-accounting 7-62 radius-server timeout-interim 7-62 radius-server radius-mac-format 7-63 radius-server vlan-format 7-63 show radius 7-64
802.1X Authentication 7-65
802.1x 7-65
802.1x broadcast-key-refresh-rate 7-66
802.1x session-key-refresh-rate 7-67
802.1x session-timeout 7-67
802.1x-supplicant enable 7-68
802.1x-supplicant user 7-68 show authentication 7-69
MAC Address Authentication 7-70
address filter default 7-70 address filter entry 7-71 address filter delete 7-71 mac-authentication server 7-72 mac-authentication session-timeout 7-72
xiv
Contents
Filtering Commands 7-73
filter local-bridge 7-73
filter ap-manage 7-74
filter uplink enable 7-74
filter uplink 7-75
filter ethernet-type enable 7-75
filter ethernet-type protocol 7-76
show filters 7-77 WDS Bridge Commands 7-77
bridge role (WDS) 7-78
bridge-link parent 7-78
bridge-link child 7-79
bridge dynamic-entry age-time 7-79
show bridge aging-time 7-80
show bridge filter-entry 7-81
show bridge link 7-81 Spanning Tree Commands 7-83
bridge stp enable 7-83
bridge stp forwarding-delay 7-84
bridge stp hello-time 7-84
bridge stp max-age 7-85
bridge stp priority 7-85
bridge-link path-cost 7-86
bridge-link port-priority 7-86
show bridge stp 7-87 Ethernet Interface Commands 7-88
interface ethernet 7-88
dns server 7-89
ip address 7-89
ip dhcp 7-90
speed-duplex 7-91
shutdown 7-92
show interface ethernet 7-92 Wireless Interface Commands 7-93
interface wireless 7-95
vap 7-95
speed 7-96
multicast-data-rate 7-96
channel 7-97
transmit-power 7-97
radio-mode 7-98
preamble 7-99
antenna control 7-99
antenna id 7-100
antenna location 7-101
xv
Contents
beacon-interval 7-101 dtim-period 7-102 fragmentation-length 7-102 rts-threshold 7-103 super-g 7-104 description 7-104 ssid 7-105 closed-system 7-105 max-association 7-106 assoc-timeout-interval 7-106 auth-timeout-value 7-107 shutdown 7-107 show interface wireless 7-108 show station 7-109
Rogue AP Detection Commands 7-109
rogue-ap enable 7-110 rogue-ap authenticate 7-111 rogue-ap duration 7-111 rogue-ap interval 7-112 rogue-ap scan 7-113 show rogue-ap 7-113
Wireless Security Commands 7-114
auth 7-114 encryption 7-116 key 7-117 transmit-key 7-118 cipher-suite 7-119 mic_mode 7-120 wpa-pre-shared-key 7-121 pmksa-lifetime 7-121 pre-authentication 7-122
Link Integrity Commands 7-123
link-integrity ping-detect 7-124 link-integrity ping-host 7-124 link-integrity ping-interval 7-125 link-integrity ping-fail-retry 7-125 link-integrity ethernet-detect 7-125 show link-integrity 7-126
IAPP Commands 7-127
iapp 7-127
VLAN Commands 7-128
vlan 7-128 management-vlanid 7-129 vlan-id 7-129
WMM Commands 7-130
xvi
Contents
wmm 7-131
wmm-acknowledge-policy 7-131
wmmparam 7-132
Appendix A: Troubleshooting A-1
Appendix B: Cables and Pinouts B-1
Twisted-Pair Cable Assignments B-1
10/100BASE-TX Pin Assignments B-1
Straight-Through Wiring B-2
Crossover Wiring B-3 Console Port Pin Assignments B-3
Wiring Map for Serial Cable B-4
Appendix C: Specifications C-1
General Specifications C-1 Sensitivity C-4 Transmit Power C-4
Operating Range C-6
Glossary
Index
xvii
Contents
xviii

Chapter 1: Introduction

The 2.4 GHz Wireless Access Point is an IEEE 802.11b/g access point that provides transparent, wireless high-speed data communications between the wired LAN and fixed or mobile devices equipped with an 802.11b, or 802.11g wireless adapter.
This solution offers fast, reliable wireless connectivity with considerable cost savings over wired LANs (which include long-term maintenance overhead for cabling). Using
802.11b and 802.11g technology, this access point can easily replace a 10 Mbps Ethernet connection or seamlessly integrate into a 10/100 Mbps Ethernet LAN.
The access point supports up to eight Virtual Access Points. This allows traffic to be separated for different user groups using an access point that services one area. For each VAP, different security settings, VLAN assignments, and other parameters can be applied.
Each radio interface on the access point can operate in one of four modes:
Access Point – Providing conectivity to wireless clients in the service area.
Repeater – Providing an extended link to a remote access point from the wired
LAN. In this mode, the access point does not have a cable connection to the wired
Ethernet LAN.
Bridge – Providing links to access points operating in “Bridge” or “Root Bridge”
mode and thereby connecting other wired LAN segments.
Root Bridge – Providing links to other access points operating in “Bridge” mode
and thereby connecting other wired LAN segments. Only one unit in the wireless
bridge network can be set to “Root Bridge” mode.
In addition, the access point offers full network management capabilities through an easy to configure web interface, a command line interface for initial configuration and troubleshooting, and support for Simple Network Management Protocol tools.
Radio Characteristics – The IEEE 802.11b/g standard uses a radio modulation technique known as Orthogonal Frequency Division Multiplexing (OFDM), and a shared collision domain (CSMA/CA). It operates at the 2.4 GHz Unlicensed National Information Infrastructure (UNII) band for connections to 802.11g clients.
IEEE 802.11g includes backward compatibility with the IEEE 802.11b standard. IEEE 802.11b also operates at 2.4 GHz, but uses Direct Sequence Spread Spectrum (DSSS) and Complementary Code Keying (CCK) modulation technology to achieve a communication rate of up to 11 Mbps.
The access point supports a 54 Mbps half-duplex connection to Ethernet networks for each active channel.
1-1
Introduction
1

Package Checklist

The 2.4 GHz Wireless Access Point package includes:
• One 2.4 GHz Wireless Access Point
• One Category 5 network cable
• One RS-232 console cable
• One AC power adapter and power cord
• Four rubber feet
• User Guide CD
Inform your dealer if there are any incorrect, missing or damaged parts. If possible, retain the carton, including the original packing materials. Use them again to repack the product in case there is a need to return it.

Hardware Description

Top Panel
Antennas
LED
Indicators
1-2
Hardware Description
Rear Panel
RJ-45
Management
Port
Security Slot
5 VDC
Power Socket
Reset
Button
Console
Port

Component Description

Antennas
The access point includes integrated diversity antennas for wireless communications. A diversity antenna system uses two identical antennas to receive and transmit signals, helping to avoid multipath fading effects. When receiving, the access point checks both antennas and selects the one with the strongest signal. When transmitting, it will continue to use the antenna previously selected for receiving. The access point never transmits from both antennas at the same time.
The antennas transmit the outgoing signal as a toroidal sphere (doughnut shaped), with the coverage extending most in a direction perpendicular to the antenna. The antenna should be adjusted to an angle that provides the appropriate coverage for the service area. For further information, see “Positioning the Antennas” on 2-2.
1
LED Indicators
The access point includes three status LED indicators, as described in the following figure and table.
Power
Ethernet
Link/Activity
802.11b/g Wireless
Link/Activity
1-3
Introduction
1
LED Status Description
PWR On Indicates that the system is working normally.
Flashing Indicates running a self-test or loading the software program. Flashing (Prolonged) Indicates system errors.
Link On Indicates a valid 10/100 Mbps Ethernet cable link.
Flashing Indicates that the access point is transmitting or receiving data
11g On Indicates that the 802.11b/g radio is enabled.
Flashing Indicates that the access point is transmitting or receiving data
Off Indicates that the 802.11b/g radio is disabled.
on a 10/100 Mbps Ethernet LAN. Flashing rate is proportional to network activity.
through wireless links. Flashing rate is proportional to network activity.
Security Slot
The access point includes a Kensington security slot on the rear panel. You can prevent unauthorized removal of the access point by wrapping the Kensington security cable (not provided) around an unmovable object, inserting the lock into the slot, and turning the key.
Console Port
This port is used to connect a console device to the access point through a serial cable. This connection is described under “Console Port Pin Assignments” on page B-3. The console device can be a PC or workstation running a VT-100 terminal emulator, or a VT-100 terminal.
Ethernet Port
The access point has one 10BASE-T/100BASE-TX RJ-45 port that can be attached directly to 10BASE-T/100BASE-TX LAN segments. These segments must conform to the IEEE 802.3 or 802.3u specifications.
This port supports automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs, switches, or hubs.
The access point appears as an Ethernet node and performs a bridging function by moving packets from the wired LAN to remote workstations on the wireless infrastructure.
Note: The RJ-45 port also supports Power over Ethernet (PoE) based on the IEEE
802.3af standard. Refer to the description for the “Power Connector” for information on supplying power to the access point’s network port from a network device, such as a switch, that provides Power over Ethernet (PoE).
1-4

Features and Benefits

Reset Button
This button is used to reset the access point or restore the factory default configuration. If you hold down the button for less than 5 seconds, the access point will perform a hardware reset. If you hold down the button for 5 seconds or more, any configuration changes you may have made are removed, and the factory default configuration is restored to the access point.
Power Connector
The access point does not have a power switch. It is powered on when connected to the AC power adapter, and the power adapter is connected to a power source. The power adapter automatically adjusts to any voltage between 100-240 volts at 50 or 60 Hz. No voltage range settings are required.
The access point may also receive Power over Ethernet (PoE) from a switch or other network device that supplies power over the network cable based on the IEEE
802.3af standard.
Note that if the access point is connected to a PoE source device and also connected to a local power source through the AC power adapter, PoE will be disabled.
Features and Benefits
• Local network connection via 10/100 Mbps Ethernet ports or 54 Mbps wireless interface (supporting up to 128 mobile users)
• IEEE 802.11b, and 802.11g compliant
• Interoperable with multiple vendors based on the IEEE 802.11f protocol
• Advanced security through 64/128/152-bit Wired Equivalent Protection (WEP) encryption, IEEE 802.1X authentication via a RADIUS server, Wi-Fi Protected Access (WPA), and MAC address filtering features to protect your sensitive data and authenticate only authorized users to your network
• Provides seamless roaming within the IEEE 802.11b and 802.11g WLAN environment
• Scans all available channels and selects the best channel for each client based on the signal-to-noise ratio
• Allows the country of operation to be set to match regulatory requirements (for countries outside of the United States)
1
1-5
Introduction
1

System Defaults

The following table lists some of the access point’s basic system defaults. To reset the access point defaults, use the CLI command “reset configuration” from the Exec level prompt.
Table1-1. System Defaults
Feature Parameter Default
Identification System Name SMC Administration User Name admin
Password smcadmin
General HTTP Server Enabled
HTTP Server Port 80 HTTPS Server Enabled HTTPS Server Port 443 Web Redirect Disabled
TCP/IP DHCP Enabled
IP Address 192.168.2.2 Subnet Mask 255.255.255.0 Default Gateway 0.0.0.0 Primary DNS IP 0.0.0.0 Secondary DNS IP 0.0.0.0
RADIUS (Primary and Secondary)
SSH Server Status Enabled
PPPoE PPPoE Status Disabled
IP Address 0.0.0.0 Port 1812 Key DEFAULT Timeout 5 seconds Retransmit attempts 3 Accounting Port 0 (Disabled) Interim Update Timeout 3600 seconds
Server Port 22
1-6
Table1-1. System Defaults
Feature Parameter Default
MAC Authentication MAC Disabled
Authentication Session Timeout 0 minutes (disabled) Local MAC System Default Allowed Local MAC Permission Allowed
802.1X Authentication Status Disabled Broadcast Key Refresh 0 minutes (disabled) Session Key Refresh 0 minutes (disabled) Reauthentication Refresh Rate 0 seconds (disabled) Supplicant Disabled
VLAN Man age me nt VLA N ID 1
VLAN ID (VAP Interface) 1 VLAN Tag Support Disabled
QoS QoS Mode Off
SVP (SpectraLink Voice Priority) Disabled
Filter Control Local Bridge Disabled
AP Management Enabled Ethernet Type Disabled
SNMP Status Enabled
Location null Contact null Community (Read Only) Public Community
(Read/Write) Traps Enabled Trap Destination (1-4) Disabled Trap Destination IP Address null Trap Destination Community
Name SNMP v3 Groups RO
SNMP v3 Users none
Private
Public
RWAuth RWPriv
System Defaults
1
1-7
Introduction
1
Table1-1. System Defaults
Feature Parameter Default
System Logging Syslog Disabled
Logging Host Disabled Logging Console Disabled IP Address / Host Name 0.0.0.0 Logging Level Informational Logging Facility Type 16
System Clock SNTP Server Status Enabled
SNTP Server 1 IP 137.92.140.80 SNTP Server 2 IP 192.43.244.18 Date and Time 00:00, Jan 1, 1970 (when there is no time
Daylight Saving Time Disabled
Time Zone GMT-5 (Eastern Time, US and Canada) Ethernet Interface Speed and Duplex Auto Wireless Interface
802.11b/g
IAPP Enabled
SSID SMC
Radio Mode b+g
Status Disabled
Auto Channel Select Enabled
Closed System Disabled
Transmit Power Full
Max Station Data Rate 54 Mbps
Multicast Data Rate 5.5 Mbps
Preamble Length Long
Beacon Interval 100 TUs
Data Beacon Rate (DTIM Interval) 1 beacon
RTS Threshold 2347 bytes
Association Timeout Interval 30 minutes
Authentication Timeout Interval 60 minutes
Rogue AP Detection Disabled
Antenna Control Method Diversity
server)
1-8
Table1-1. System Defaults
Feature Parameter Default
Wireless Interface
802.11b/g (contd.) Wireless Security
802.11b/g
Link Integrity Status Disabled
Antenna ID 0x0000 Antenna Location Indoor Authentication Type Open System Data Encryption Disabled WEP Key Length 128 bits WEP Key Type Hexadecimal WEP Transmit Key Number 1 WEP Keys null WPA Configuration Mode WEP Only (Disabled) WPA Key Management WPA Pre-shared Key WPA PSK Type Alphanumeric Multicast Cipher WEP
Ping Interval 30 seconds Fail Retry Count 6
System Defaults
1
1-9
Loading...