Page 1
USER GUIDE
EZ SwitchTM 10/100/1000 16-Port Unmanaged Gigabit Ethernet PoE Switch
SMCGS1601P
Page 2
EZ Switch
TM
10/100/1000
User Guide
From SMC’s EZ line of low-cost workgroup LAN solutions
September 2012
SMC-UG-0912-01
Page 3
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or ot herwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice.
Copyright © 2012 by
SMC Networks, Inc.
No. 1, Creation Road III,
Hsinchu Science Park,
30077, Taiwan, R.O.C.
All rights reserved
Trademarks:
SMC is a registered trademark; and EZ Switch, TigerStack and TigerSwitch are trademarks of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders.
Page 4
4
W
ARRANTY AND
P
RODUCT
R
EGISTRATION
To register SMC products and to review the detailed warranty statement, please refer to the Support Section of the SMC Website at http://www.smc.com.
Page 5
– 5 –
COMPLIANCES AND SAFETY STATEMENTS
FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipm ent generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interfere nce that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
N
OTE
:
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
Page 6
C
OMPLIANCES AND SAFETY STATEMENTS
– 6 –
CE MARK DECLARATION OF CONFORMANCE FOR EMI AND SAFETY (EEC)
This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/ 68/EEC. For the ev aluation of th e compliance with these Di rectives, the foll owing standards were applied:
RFI Emission:
Limit according to EN 55022:2006+A1:2007
Limit for harmonic current emission according to EN 61000-3-
2:2006+A2:2009
Limitation of voltage fluctuation and flicker in low-voltage supply
system according to EN 61000-3-3:2008
Immunity:
Product family standard according to EN 55024:2010
Electrostatic Discharge according to EN55024 &4.2.1
Radio-frequency electromagnetic field according to EN55024 &4.2.3.1
Electrical fast trsnsient/burst according to EN55024 &4.2.2
Surge immunity test according to EN55024 &4.2.5
Immunity to conducted disturbances, Induced by radio-frequency
fields: EN55024 &4.2.3.2
Power frequency magnetic field immunity test according to EN55024
&4.2.4
Voltage dips, short interruptions and voltage variations immunity test
according to EN55024 &4.2.6
LVD:
EN60950-1:2006+A11:2009+A1:2010+A12:2011
Page 7
C
OMPLIANCES AND SAFETY STATEMENTS
– 7 –
INDUSTRY CANADA - CLASS A
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Department of Communications.Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils num ériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Appareils Numériques,” NMB-003 édictée par le ministère des Communications.
PLEASE READ THE FOLLOWING SAFETY INFORMATION CAREFULLY BEFORE
INSTALLING THE SWITCH:
W
ARNING: Installation and removal of the unit must be carried out by qualified
personnel only.
This guide is intended for use by network administrators who are
responsible for set ting up and ins talling network equipment; cons equently it assumes a basic working knowledge of LANs (Local Area Networks).
The unit must be connected to an earthed (grounded) outlet to comply with
international safety standards.
Do not connect unit to an A.C outlet (power supply) without an earth
(ground) connection.
The appliance coupler (the connector to the unit and not the wall plug)
must have a configuration for mating with an EN 60320/IEC 320 appliance inlet.
The socket outlet must be near to the unit and easily accessible. You can
only remove power from the unit by disconnecting the power cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions
according to IEC 60950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions.
Page 8
C
OMPLIANCES AND SAFETY STATEMENTS
– 8 –
SAFETY PRECAUTIONS
Read the following information carefully before operating the device. Please follow the following precaution items to protect the device from risks and damage caused by fire and electric power:
Use the power adapter that is included with the device package.
Pay attention to the power load of the outlet or prolonged lines. An
overburdened power outlet or damaged cords and plugs may cause electric shock or fire. Check the power cords regularly, if you find any damage, replace it at once.
Proper space for heat dissipation is necessary to avoid any damage caused
by device overheating. The ventilation holes on the device are designed for heat dissipation to ensure that the device works normally. Do not cover these ventilation holes.
Do not put this device close to a place where a heat source exits or high
temperature occurs. Avoid placing the device in direct sunshine.
Do not put this device close to a place which is damp or wet. Do not spill
any fluid on this device.
Please follow the instructions in the user manual/quick install guide carefully
to connect the device to your PC or other electronic product. Any invalid connection may cause a power or fire risk.
Do not place this device on an unstable surface or support.
PRÉCAUTIONS DE SÉCURITÉ
Lisez attentivement les informations suivantes avant d’utiliser votre appareil. Respectez toutes les précautions afin de protéger l’appareil des risques et dégâts provoqués par un incendie et l’alimentation électrique :
Utilisez exclusivement l’adaptateur d’alimentation fourni avec cet appareil.
Faites attention à la puissance de charge de la prise de courant ou des
rallonges électriques. Une prise surchargée ou des cordons et des fiches endommagés peuvent provoquer une électrocution ou un incendie. Vérifiez régulièrement votre câble électrique. Si vous constatiez le moindre défaut, remplacez-le immédiatement.
Il est primordial de laisser suffisamment d’espace autour de l’appareil pour
permettre la dissipation de la chaleur et éviter les dégâts provoqués par une
Page 9
C
OMPLIANCES AND SAFETY STATEMENTS
– 9 –
surchauffe de l’appareil. Les orifices de ventilat ion de l’appareil sont conçus pour permettre la dissipation thermique et garantir le bon fonctionnement de l’appareil. Ne couvrez jamais ces orifices.
Ne placez pas cet appareil à proximité d’une source de chaleur ou dans un
endroit exposé à des températures élevées. Evitez également de l’exposer à la lumière directe du soleil.
Ne placez pas cet appareil à proximité d’un lieu humide ou mouillé. Prenez
garde à ne renverser aucun liquide sur cet appareil.
Merci de suivre les instructions du manuel d'utilisateur / guide d’installation
rapide attentivement pour connecter l'appareil à votre PC ou à tout autre produit électronique. Toute connexion non valide peut provoquer un problème électrique ou un risque d'incendie.
Ne placez pas cet appareil sur une surface ou un support instable.
SICHERHEITSMAßNAHMEN
Lesen Sie vor der Inbetriebnahme des Gerätes aufmerksam die nachstehenden Informationen. Bitte befolgen Sie die nachstehenden Sicherheitsmaßnahmen, damit das Gerät nicht beschädigt wird oder Gefahren durch Brand oder elektrische Energie entstehen:
Verwenden Sie nur das beim Gerät mitgelieferte Netzteil.
Achten Sie auf die Last der Steckdose oder des Verlängerungskabels. Eine
überlastete Steckdose oder beschädigte Kabel und Stecker können Stromschläge und Brand verursachen. Prüfen Sie die Netzkabel rege lmäßig. Ersetzen Sie sie umgehend, falls sie beschädigt sind.
Achten Sie zur Vermeidung von Geräteschäden aufgrund von Überhitzung
darauf, dass genügend Freiraum zur Wärmeabfuhr vorhanden ist. Die Belüftungsöffnungen am Gerät dienen der Wärmeabfuhr und damit der Gewährleistung eines normalen Gerätebetriebs. Decken Sie diese Belüftungsöffnungen nicht ab.
Stellen Sie dieses Gerät nich t in de r Nähe v on Wärmeq uell en ode r an Orten
mit hohen Temperaturen auf. Platzieren Sie das Gerät nicht im direkten Sonnenlicht.
Stellen Sie dieses Gerät nicht an feuchten oder na ssen Orten auf. Achten
Sie darauf, keine Flüssigkeiten über dem Gerät zu verschüt ten.
Page 10
C
OMPLIANCES AND SAFETY STATEMENTS
– 10 –
Befolgen Sie die Hinweise im Benutzerhandbuch (bzw. in der Kurzanleitung)
zum Anschluß des Gerätes an einen PC oder ein anderes Elektrogerät. Jegliche unzulässige Verbindung birgt die Gefahr von Stromschlägen und Brandgefahr.
Platzieren Sie dieses Gerät nicht auf einer instabilen Oberfläche oder
Halterung.
PRECAUCIONES DE SEGURIDAD
Lea la siguiente información detenidamente antes de utilizar el dispositivo. Siga las indicaciones de precaución que se mencionan a continuación para proteger el dispositivo contra riesgos y daños causados por el fuego y la energía eléctrica:
Utilice el adaptador de alimentación incluido en el paquete del dispositivo.
Preste atención a la carga de potencia de la toma de corriente o de los
alargadores. Una toma de corriente sobrecargada o líneas y enchufes dañados pueden provocar descargas eléctricas o un incendio. Comprueb e los cables de alimentación con cierta frecuencia. Si detecta algún daño, reemplácelos inmediatamente.
Deje un espacio adecuado para que se disipe el calor y evitar así cualquier
daño en el dispositivo causado por sobrecalentamiento. Los orificios de ventilación del dispositivo est án dise ñados para disipar el calor y garantizar que dicho dispositivo funciona con normalidad. No tape estos orificios de ventilación.
No coloque este dispositivo cerca de un lugar donde haya una fuente de
calor o temperaturas elevadas. Evite exponer el dispositivo a la luz solar directa.
No coloque este dispositivo junto a un lugar húmedo o mojado. No derrame
ningún fluido sobre el dispositivo.
Por favor, siga cuidadosamente las instrucciones que figuran en el manual/
guía de instalación rápida para conectar el dispositivo a su PC o a cualquier otro producto electrónico. Cualquier conexión no válida podría causar riesgo de descarga o de incendio.
No coloque este dispositivo en una superficie o soporte inestable.
Precauções de Segurança
Page 11
C
OMPLIANCES AND SAFETY STATEMENTS
– 11 –
Leia atentamente as seguintes informações antes de utilizar o dispositivo.
Respeite as seguintes indicações de segurança para proteger o dispositivo contra riscos e danos causados por fogo e energia eléctrica:
Utilize o transformador incluído na em balagem do dispositivo.
Respeite a potência da tomada eléctrica e das extensões. Uma tomada
eléctrica sobrecarregada ou cabos e fichas danificadas podem causar choques eléctricos ou fogo. Verifique regularmente os cabos de alimentação. Caso algum se encontre danificado, substitua-o imediatamente.
É necessário deixar algum espaço livre em volta do dispositivo para
dissipação de calor, de forma a evitar danos ca u s a d os pelo sobreaquecimento do dispositivo. Os orifícios de ventilação do dispositivo foram concebidos para dissipar o calor e assegurar que o mesmo funciona normalmente. Não bloqueie esses orifícios de ventilação.
Não coloque este dispositivo junto a fontes de cal or ou em locais com
temperaturas elevadas. Evite colocar o dispositivo sob luz solar directa.
Não coloque este dispositivo junto a locais molhados ou com humidade. Não
derrame líquidos sobre o dispositivo.
Por favor siga atentamente as instruções do manual / guia de instalação
rápida para conectar o dispositivo ao seu PC ou a qualquer outro dispositivo electrónico. Atenção que qualquer tipo de ligação inválida pode originar risco de choque eléctrico ou de incêndio.
Não coloque este disp ositivo numa superfície ou s u porte instáveis.
Page 12
C
OMPLIANCES AND SAFETY STATEMENTS
– 12 –
Page 13
– 13 –
ABOUT THIS GUIDE
PURPOSE
This guide details the hardware features of the switch, including the physical and performance-related characteristics, and how to install the switch.
AUDIENCE
The guide is intended for use by network administrators who are responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
CONVENTIONS
The following conventions are used throughout this guide to show information:
REVISION HISTORY
This section summarizes the changes in each revision of this guide.
SEPTEMBER 2012 REVISION
This is the first revision of this guide.
N
OTE
:
Emphasizes important information or calls your attention to related features or instructions.
C
AUTION
:
Alerts you to a p ote nt ial haz ard th at co uld caus e lo ss of d ata,
or damage the system or equipment.
W
ARNING
:
Alerts you to a potential hazard that could cause personal
injury.
Page 14
A
BOUT THIS GUIDE
– 14 –
Page 15
– 15 –
CONTENTS
WARRANTY AND PRODUCT REGISTRATION 4
C
OMPLIANCES AND SAFETY STATEMENTS 5
A
BOUT THIS GUIDE 13
C
ONTENTS 15
1I
NTRODUCTION 17
Overview 17
Features 17 PoE Features 18 IEEE 802.1p QoS 18
2HARDWARE DESCRIPTION 21
Front Panel 21
Port and System Status LEDs 21 RJ-45 Ports 22
Rear Panel 22
AC Power Socket 22
3INSTALLING THE SWITCH 23
Package Contents 23 Precautions 23
Safety Requirements 23 Location Requirements 24
Installation 24
Desktop Installation 25 Rack Installation 25 Connecting to Ground 27
Page 16
C
ONTENTS
– 16 –
Powering On 28
Connecting Network Devices 29
Cabling Guidelines 29 Connecting to PCs, Servers, Hubs and Switches 29
4PRODUCT APPLICATION 31
Department/Workgroup PoE Switch 31 Power over Ethernet Powered Devices 32
ATROUBLESHOOTING 33
Diagnosing Switch Indicators 33
The Power LED is Off 33 The Link/Act LED is Off when a Device is Connected to the Corre-
sponding Port 33 Power and Cooling Problems 33 Installation 34
BSPECIFICATIONS 35
Physical Characteristics 35
Page 17
– 17 –
1 INTRODUCTION
OVERVIEW
The EZ Switch 10/100 SMCGS1601P PoE switch pro vi des 16 10/1 00/ 1000 Mbps auto-negotiating RJ-45 ports. Each port on the switch support auto MDI/MDI-X, which eliminates the need for crossover cables or uplink ports. The switch is plug-and-play; any port can be connected to a server, a hub, or a switch, using straight-through or crossover cable.
FEATURES
Complies with IEEE 802.3, IEEE 802.3u, and IEEE 802.3ab standards
16 10/100/1000 Mbps auto-negotiating RJ-45 ports supporting Auto-MDI/
MDIX
Supports PoE power up to 30W for each PoE port
PoE total power budget 200W for all PoE ports
Supports IEEE 802.3x flow control for full-duplex mode and backpressure
for half-duplex mode
LED indicators for monitoring power, link, activity
Rack-mountable steel case
Support for IEEE 802.3az Energy-Efficient Ethernet, which can save up to
72.23% of power consumption
Support for IEEE 802.1p QoS
Page 18
C
HAPTER
1
| Introduction
Overview
– 18 –
POE FEATURES
The SMCGS1601P can provide up to 30 W att s of power to attached devices, su ch as VoIP phones, wireless access points, surveillance cameras, etc, all over existing Cat. 5 cables. The switch can deliver up to 30 Watts on 8 ports, or 15.4 Watts on 16 ports. This eliminates the need for individual power sources for devices in the network, saving on costs for power cables and avoiding power outlet availability issues.
IEEE 802.1P QOS
The SMCGS1601P switch supports 802.1p priority queuing Quality of Service, which is an implementation of the IEEE 802.1p standard. With the 802.1p QoS function, network traffic that requires high priority, such as VoIP (Voice-over Internet Protocol), web browsing applications or video conferencing, can be forwarded before other traffic. The switch has separate hardware queues for each physical port, when packets are received with an 802.1p priority tag, they are sent to the appropriate output queue.
The illustration below shows how 802.1p priority queuing i s implemented on t he switches.
Figure 1: Mapping QoS on the Switch
There are four priority levels labeled TC0, TC1, TC2 and TC3. The untagged packets and the eight IEEE 802.1p priority tags (defined by th e standard) are mapped to the four priority queues on the switch. TC3 ha s the highe st priorit y of the four priority queues while TC0 has the lowest priority . The untagged packets and eight priority tags, specified in IEEE 802.1p, are mapped to the switch’s priority tags as follows:
Untagged packets, and packets with priority tag 1 and 2 are assigned to the
switch’s TC0 level queue.
Packets with priority tag 0 and 3 are assigned to the switch’s TC1 level
queue.
Packets with priority tag 4 and 5 are assigned to the switch’s TC2 level
queue.
Tag untag 0 1 2 3 4 5 6 7
Priority Level
Weight Value 1 2 4 8
TC0 TC1 TC2 TC3
Page 19
C
HAPTER
1
| Introduction
Overview
– 19 –
Packets with priority tag 6 and 7 are assigned to the switch’s TC3 level
queue.
The SMCGS1601P switch uses Weighted Robin Round (WRR) for scheduling. The WRR queue-scheduling algorithm schedules all the queues in turn with every queue assured a certain service time. F or both WFQ and WR R mode, the de fault weight values of TC0, TC1, TC2 and TC3 are 1:2:4:8.
Page 20
C
HAPTER
1
| Introduction
Overview
– 20 –
Page 21
– 21 –
2 HARDWARE DESCRIPTION
This chapter describes the front panel, rear panel, and LED indicators of the switch.
FRONT PANEL
The front panel of SMCGS1601P consists of switch LED indicators, and 16 10/ 100/1000 Mbps RJ-45 ports.
Figure 2: SMCGS1601P Switch Front Panel
PORT AND SYSTEM STATUS LEDS
This switch includes a display panel for key system and port indications that simplify installation and network troubleshooting. The LEDs, which are located on the front panel, are described in the following table.
Table 1: System and Port Status LEDs
LED Condition Status
PWR On Red The internal power supply is operating normally.
Off The unit has no power connected.
LiK/ACT On Green Port has established a valid 10/100 Mbps network
connection.
On Orange Port has established a valid 10/100/1000 Mbps
network connection.
Off There is no valid link on the port.
PoE In Use On Yellow A PoE device is connected.
Off No PoE device connected.
EZ Switch 10/100/1000Mbps 16-Port Gigabit Ethernet PoE Switch
Page 22
C
HAPTER
2
| Hardware Description
Rear Panel
– 22 –
RJ-45 PORTS
The switch contains 16 1000BASE-TX RJ-45 ports. All ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.
Each of these ports support auto-negotiation, so the optimum transmission mode (half or full duplex), and data rate (10/100/1000 Mbps) is selected automatically.
Each port also supports IEEE 802.3x auto-negotiation of flow control, so the switch can automatically prevent port buffers from becoming saturated.
REAR PANEL
The rear panel of the switch features a power socket.
Figure 3: SMCGS1601P Switch Rear Panel
AC POWER SOCKET
Connect the female connector of the power cord here, and the male connector to the AC power outlet. Make sure the voltage of the power supply meets the requirement of the input voltage.
100-240VAC 50-60Hz 1A
100-240 VAC
50 / 60 Hz
Page 23
– 23 –
3 INSTALLING THE SWITCH
Before installing the switch, verify that you have all the items listed under “Package Contents.” If any of the items are missing or damaged, contact your local SMC distributor. Also be sure you have all the necessary tools and cabling before installing the switch.
PACKAGE CONTENTS
The following contents should be found in your package:
One SMCGS1601P Switch
One power cord
This User Guide
Rackmount Kit
Four rubber foot pads
SMC Warranty Card
PRECAUTIONS
T o ensure a long-term and stable performance of the switch, pay attention to the following before in stallation.
SAFETY REQUIREMENTS
Before cleaning the switch, disconnect the power supply. Do not clean the
switch using a wet cloth, and never use any other liquid for cleaning.
Page 24
C
HAPTER
3
| Installing the Switch
Installation
– 24 –
Take waterproof measures during storage, transportation and operation of
the equipment.
Use only the power cord provided with the switch.
Make sure the voltage of the power supply meets the requirement of the
input voltage of the switch.
Do not push any objects into the openings of the switch.
Ensure the vent holes are well ventilated and unblocked.
Do not open or remove the cover of the switch.
LOCATION REQUIREMENTS
When you choose a location for the switch, follow these guidelines :
Install the switch on a flat and stable surface that can support the entire
weight of the switch with all fittings.
Locate the switch far from strong electromagnetic field generators (such as
motors), vibration, dust, and direct exposure to sunlight.
To ensure adequate air flow around the switch. At least 10 cm (4 i nches) of
space at the front and rear of the switch is needed for ventilation.
Make sure that the switch will be accessible and that the cables can be
easily connected.
Position the switch away from water and moisture sources, be sure to
provide an acceptable temperature and humidity operating environment.
INSTALLATION
This switch can be either installed in a standard 19-inch mountable rack or located on a desktop.
C
AUTION
:
Please unplug the power cord before installing or removing
the switch.
Page 25
C
HAPTER
3
| Installing the Switch
Installation
– 25 –
DESKTOP INSTALLATION
To install the switch on the desktop, follow these steps:
1. Set the switch on a flat surface strong enough to support the entire weight
of the switch with all fittings.
2. Remove the adhesive backing papers from the rubber feet.
3. Turn the switch over and attach the supplied rubber feet to the recessed
areas on the bottom at each corner of the switch.
Figure 4: Attaching Rubber Feet
4. Upturn the switch and set in the desired location, making sure there is
enough ventilation space on all sides for proper air flow
5. Connect the switch to a power source with the provided power cord. See
“Powering On” on page 28.
RACK INSTALLATION
To instal l the switch in an EIA standard-sized, 19-inch rack, follow the instructions described below:
1. Secure the supplied rack-mounting brackets to each side of the switch with
supplied screws, as illustrated in the following figure.
C
AUTION
:
Avoid placing anything heavy on the switch.
EZ Switch 10/100/1000Mbps
16-Port Gigabit Ethernet PoE Switch
Page 26
C
HAPTER
3
| Installing the Switch
Installation
– 26 –
Figure 5: Attaching Brackets
EZ Switch 10/100/1000Mbps
16-Port Gigabit Ethernet PoE Switch
Page 27
C
HAPTER
3
| Installing the Switch
Installation
– 27 –
2. Use suitable screws (not provided) to secure the brackets to the rack, as
illustrated in the following figur e.
Figure 6: Mounting the Switch
3. Connect the switch to a power source with the provided power cord. See
“Powering On” on page 28.
CONNECTING TO GROUND
Connecting the switch to ground protects against lightning over-voltage and over-current of the switch, which is also a necessary measure to protect the body from electric shock.
In different environments, the switch may be grounded differently . The following instructs you to connect the switch to ground through the power cord. Connect the switch to ground in the best way according to your specific operating environment.
EZ Switch 10/100/1000Mbps 16-Port Gigabit Ethernet PoE Switch
Page 28
C
HAPTER
3
| Installing the Switch
Installation
– 28 –
CONNECTING TO GROUND THROUGH THE POWER SUPPLY
If the switch is installed in a normal environment, it can be grounded through the PE (Protective Earth) wire of the AC power supply, as shown in the following figure.
Figure 7: Connecting to Ground Through the Power Supply
POWERING ON
The SMCGS1601P switch is powered by connecting to an AC power supply using a power cord. When powering on the switch, it automatically initializes and the LED indicators respond as follows:
1. All of the LED indicators flash momentarily for one second, wh ich represents
a resetting of the system.
N
OTE
:
The figure illustrates the application and principle. The power plug in the package and the socket in your situation will comply with regulations in your country, so they may differ from the figure above.
N
OTE
:
If you intend to connect the switch to ground through the PE (Protective Earth) wire of the AC power cord, make sure the PE wire in the electrical outlet is well grounded in advance.
100-240 VAC
5
0
/ 6
0
H
z
Page 29
C
HAPTER
3
| Installing the Switch
Connecting Network Devices
– 29 –
2. The Power LED indicator turns on green.
CONNECTING NETWORK DEVICES
This switch is designed to be connected to 10, or 100 Mbps network cards in PCs and servers, as well as to other switches and hubs.
CABLING GUIDELINES
The RJ-45 ports on the switch support automatic MDI/MDI-X pinout configuration, so you can use standard straight-through twisted-pair cables to connect to any other network device (PCs, servers, switches, routers, or hubs).
Each device requires an unshielded twisted-pair (UTP) cable with RJ-45 connectors at both ends. Use Category 5 or better for 100BASE- TX connec tions, and Category 3 or better for 10BASE-T connections.
CONNECTING TO PCS, SERVERS, HUBS AND SWITCHES
1. Attach one end of a twisted-pair cable segment to the device’s RJ-45
connector.
2. Attach the other end of the cable segment to an available port on the
switch.
Make sure each twisted pair cable does not exceed 100 meters (328 ft) in length.
3. As each connection is made, the relevant port LED (on the switch)
corresponding to each port will turn on green to indi cate that the connection is valid.
Page 30
C
HAPTER
3
| Installing the Switch
Connecting Network Devices
– 30 –
Page 31
– 31 –
4 PRODUCT APPLICATION
DEPARTMENT/WORKGROUP POE SWITCH
The SMCGS1601P provides 16 PoE port interfaces and can build a centrally­controlled IP phone system, IP camera system, or wireless AP group for the enterprise. Cameras can be installed around the company or campus for surveillance needs, or wireless APs can build a wireless roaming environment in the office. Without being li mited by power-socket availability, the switch makes installation of cameras or wireless APs easy and efficient .
Figure 8: Applications
Non-PoE IP Camera
PoE IP Camera
DC
PoEPoE
PoEPoE
PoE Splitter
PoE Wireless AP
Center of Surveillance
PoE IP Phone
SMCGS1601P
EZ Switch 10/100/1000Mbps
16-Port Gigabit Ethernet PoE Switch
100BASE-TX UTP
100BASE-TX UTP With PoE
1000BASE-T UTP With PoE
Power Line (DC)
PoEPoE
PoEPoE
Page 32
C
HAPTER
4
| Product Application
Power over Ethernet Powered Devices
– 32 –
POWER OVER ETHERNET POWERED DEVICES
Table 2: Power over Ethernet Powered Devices
3~5 Watts
Voice over IP phones
Enterprises can install PoE VoIP phones, ATA and other Ethernet/ non-Ethernet end-devices connect ed to a central location where an un-interruptible power supply and power control system are installed.
6~12 Watts
Wireless LAN Access Points
Museums, sightseeing spots, airports, hotels, campuses, factor ies, and warehouses can install access points anywhere without limitations.
10~12 Watts
IP Surveillance
Enterprises, museums, campuses, hospitals, and banks can install IP cameras without any location limits - no need for an electrician to install AC sockets.
3~12 Watts
PoE Splitter
A PoE splitter splits the P oE 48 VDC from t he Ethernet cable into a 5/12V DC power output. It frees device deployment from the restrictions of power outlet locati on, which eliminates the costs for additional AC wiring and reduces installation time.
Page 33
– 33 –
A TROUBLESHOOTING
DIAGNOSING SWITCH INDICATORS
THE POWER LED IS OFF
Make sure the AC power cord is connected to the switch and power source
properly.
Make sure the power source is ON.
THE LINK/ACT LED IS OFF WHEN A DEVICE IS CONNECTED TO THE C
ORRESPONDING PORT
Make sure that the cable connectors are firmly plugged into the switch and
the device.
Make sure the connected device is turned on and working properly.
The cable must be less than 100 meters long (328 feet).
Check the port on the attached device and cable connections for possible
defects. Replace the defective cable if necessary.
POWER AND COOLING PROBLEMS
If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet. If you still cannot isolate the problem, the internal power supply may be defective.
Page 34
A
PPENDIX
A
| Troubleshooting
Installation
– 34 –
INSTALLATION
Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly.
Page 35
– 35 –
B SPECIFICATIONS
PHYSICAL CHARACTERISTICS
STANDARDS
IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3ab 1000BASE-TX
TOPOLOGY
Star
PROTOCOL
CSMA/CD
DATA TRANSFER RATE
Ethernet: 10 Mbps (half duplex) Ethernet: 20 Mbps (full duplex) Fast Ethernet: 100 Mbps (half duplex) Fast Ethernet: 200 Mbps (full duplex) Gigabit Ethernet :1000 Mbps (full duplex)
NETWORK MEDIA (CABLE)
10BASE-T: UTP Category 3, 4, 5 cable (maximum 100 m) EIA/TIA-568 100 STP (maximum 100 m) 100BASE-TX: UTP Category 5, 5e cable (maximum 100 m) EIA/TIA-568 100 STP (maximum 100 m) 1000BASE-T: RJ-45 (100-ohm, UTP or STP cable; Category 5, 5e or 6 *Maximum Cable Length - 100 m (328 ft)
Page 36
A
PPENDIX
B
| Specifications
Physical Characteristics
– 36 –
NUMBER OF PORTS
16 10/100/1000 Mbps auto-negotiating RJ-45 ports
LED INDICATORS
Syste m: PWR Ports: LNK/ACT, PoE In Use
TRANSFER METHOD
Store-and-Forward
MAC ADDRESS LEARNING
Automatically learning, automatically aging
FRAME FILTER RATE
10Mbps: 14880pps 100Mbps: 148800pps 1000Mbps: 1488000pps
FRAME FORWARD RATE
10Mbps: 14880pps 100Mbps: 148800pps 1000Mbps: 1488000pps
SWITCHING DATABASE
8K MAC address entries
BUFFER MEMORY
2M bits (256 Kbytes) /device
SWITCHING CAPACITY
32 Gbps
Page 37
A
PPENDIX
B
| Specifications
Physical Characteristics
– 37 –
THROUGHOUT
24 Mpps
POE FEATURES
Supports IEEE 802.3af/at Supported Power to PD: 30W Total PoE Budget: 200W (Total Power: 240W) PoE Ports: 16 ( Ports 1-16)
POWER SUPPLY
AC input : 100~240V, 50/60Hz DC output: DC 50V, 4.5A
DIMENSIONS
44.2 x 20.8 x 4.4 cm (17.4 x 8.2 x 1.73 in.)
WEIGHT
2.56 Kg (5.65 lbs)
FEATURE
Jumbo Frames: 9216 Bytes
TEMPERATURE
Operating: 0 to 40 °C (32 to 104 °F) Storage: -40 to 70 °C (-40 to 158 °F)
HUMIDITY
Operating: 10% to 90% (non-condensing) Storage: 10% to 90% (non-condensing)
Page 38
A
PPENDIX
B
| Specifications
Physical Characteristics
– 38 –
Page 39
Page 40
20 Mason • Irvine, CA 92618 • Phn: 949-679-8000 • www.smc.com
150200062800A R02
www.edge-core.com/ www.smc.com
www.smcnetworks.co.kr
www.smc-asis.com
su www.smc.com
SMC NETWORKS TECHNICAL SUPPORT From Singapore in English and (Mon.-Fri. 9AM to 5 PM)
Tel: +65-63387667, Ext. 4
From U.S.A. and Canada (24 hours a day, 7 days a week)
Tel: +1 (800) SMC-4-YOU/+1 (949) 679-8000 Fax: +1 (949) 679-1481
563 8888
668 6 1 1 1
SMCGS1601P
Loading...