Smart Temp Australia P/L U20/1488 Ferntree Gully Road Knoxfield Vic 3180 Phone (03) 9763 0094 Fax (03) 9763 0098
www.thermostat.com.au www.smarttemp.com.au
Smart Temp
Installation
Advanced Options
The 44-101 thermo stat is a heat in g o nly
thermostat. It has been fitted with a volt free relay
with change over contacts rated at 240V, 8 Amp
maximum.
Installing the thermostat is a simple process.
Open the thermostat by placing a flat blade in the two
slots at the base of the thermostat and gently pry apart.
Take care not to twist the case excessively as this may
damage the display.
Mount the baseplate
level o n t he w a l l ,
passing the equipment
wiring through the hole
in the centre of the
thermostat base. Use
the supplied screws to
mount the base to the
wall.
Please note that the equipment wiring shows 5 terminals however
only 3 are used. Two terminals shown as “X” in the diagram above
have no connection)
Equipment Terminals
Com terminal is the relay Common, voltage applied to this terminal
will be switch out. This input will accept 240V up to 8 Amps.
NO terminal is the terminal that is OPEN when no heating has been
called. This terminal is usually wired to the equipment heat call
terminal or to open a heating valve.
NC terminal is the terminal that is CLOSED when no heating is called.
This terminal is usually used to drive a heating valve closed.
X Terminal has no connection and is used to maintain a safe distance
between the other three terminals.
Sensor terminals
Com terminal is the common terminal for both the outside and
remote temperature senors.
In terminal is the indoor remote (or averaging) sensor terminal
Out terminal is the outside air temperature sensor terminal.
NC
X
NO
X
Com
NC
X
NO
X
Com
Smart Temp Australia P/L
www.thermostat.com.au
WIRE
ACCESS
HOLE
BATTERY
COMPARTMENT
MOUNTING
HOLE
Out
Com
In
NC
X
NO
X
Com
Load
Open
Closed
A
A
N
N
Heater or Boiler
Heating Valve
The Smart temp 44-101 thermostat has an advanced installer menu that
permits you to tune the performance of the thermostat to suit the
specific needs of your customer.
To enter this menu, press and hold the top left (Clock) and bottom right
(mode) of the thermostat. The display will change and show the first
option in the installer menu. Advance forward through the menu by
pressing the Mode button, move backwards through the menu by
pressing the Fan button, and adjust the menu options with the Up/Down
buttons. To exit the menu wait, or press and hold the MODE button.
1:PR Sets the number of daily programming events.
4 - Morning - Day - Evening - Night.
2 - Day - Night .
0 -Manual (no temperature programming).
2:Pd Sets Programming method.
7 - 7 day individual programming.
5 + 2. Weekday / weekend block programming.
5:Lc Sets the key lock to prevent tampering
OFF = All Functions Unlocked. 1 = Program Locked 2 = Mode
Locked. 4 = UP / DOWN Arrows Locked. 5 = Clock Locked
7 = Program & Mode Locked. 8 = Program / Mode / Clock
Locked. 9 = All Functions Locked.
7:HL Heating limit.
Sets the maximum permitted user heating set temperature.
8:Td Temperature Display
Sets deg C or deg F display modes.
9:CL Clock
Sets the clock mode. 12 or 24 hour.
10:St Show (set) Temperature
Turns the set temperature display ON or OFF.
11:BL Back light
Turns the back light function On or OFF.
12:rc Recovery
Enables adaptive recovery that starts the heating prior to
the program time so that the temperature is at the correct
value at the programmed time.
14:Sp Span
Sets how far below the set point the heating turns on.
15:CA Calibration
Permits the temperature sensor to be calibrated by up to
+/- 5c on 0.1c increments.
16:TT Temperature Terminal
Sets the remote Temperature Terminal function.
RS - replace the onboard sensor with the remote sensor.
AV - Average the onboard sensor and remote sensor.
20:Bp Beeper
Turns the onboard beeper on or off.
21:Rs Reset
Forces the 44-101 to default to factory settings. Set to on
then exit the menu to enable the forced factory reset.
Out
SC
In
RS-1
SENSOR
RS-1
SENSOR
INDOOR SENSOROUTDOOR SENSOR
Outside air or inside remote sensors can be fitted to the 44-101.
Smart temp offer a range of remote sensors for this application. The