Page 1
PUMPS
PUMP
MANUAL
PUMP
MANUAL
Care and Instructions
SP-75, SP-130, SP-160
VP-300, VP -600, VP-1150, VP -1650, VP-2250
SUBMERSIBLE PRO
VARIABLE PRO
SP Series
VP Series
For further information on this or other products,
please contact Smart Solar customer service.
Tel: 813.343.5775 • Email: ussupport@smartsolar.com • www.smartsolar.com
©2009 Smart Solar Inc. All Rights Reserved
®
®
Page 2
Infinity™ Magnetic Drive Variable Flow Performance Pump Kits
SP Submersible Series and VP In-line & Submersible Series
The Infinity SP and VP series of pumps are high quality products designed using the latest technological improvements in water gardening today. These pumps are suitable for use in ponds, aquariums, fountains, filters, statuary and aquatic gardens. These pumps have been developed on the basis of synchronous technology whereby the electrical parts have been fully encapsulated in epoxy resin.
The pumps have an economical, powerful and reliable motor. The SP series is suitable to be used submersibly in fresh water. The Infinity VP series of pumps are suitable for installation on dry land for in-line use or they can be used submersibly in fresh and salt water. The VP series are equipped with a ceramic shaft which allows for their use in salt water applications.
Infinity pumps are carefully inspected and tested to insure both safety and operating performance. However, failure to follow the instructions and warnings in this manual may result in pump damage and/or serious injury. Be sure to read and save this manual for future reference.
WARNING
The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying electric water pumps and other pond/ aquatics equipment. For any information regarding
the proper installation required for this pump please contact your local electrical supplies dealer or a licensed electrician.
Do not remove the grounding pin from the plug.
Do not connect to any voltage other than that shown on the pump.
Do not pump any liquids other than fresh water (fresh or salt for VP series) as specifically noted in the owner’s manual.
Do not use with water above 86°F (30°C.)
Some models of Infinity pumps are equipped with an internal thermal protector switch that will automatically turn off the pump in the case of overheating. Once the pump is cooled, the unit will restart provided that no irreversible damage has occurred.
Risk of electric shock: This pump is supplied with a grounding connector and grounding type attachment plug. To reduce the risk of electric shock, be certain that the pump is connected only to a properly grounded, grounding-type electrical receptacle.
NOTE: Insure that the electrical cord loops below the electrical outlet to form a “Drip Loop”. This will prevent water from running down the cord and into the electrical outlet.
CAUTION & SAFETY WARNINGS
Check that the power supply is properly rated and fused. If the pump or the power cable does not comply with your local electrical code standards – DO NOT connect the pump to the equipment.
To reduce the risk of electrical shock, unplug the power cord from the receptacle before handling the pump at any time.
Always disconnect the power before cleaning the pump or when performing maintenance on the pond or water area where the pump is being used. This includes draining or changing the water in your aquatic feature or putting any part of your body into the water.
Do not connect the pump to the electrical supply while the pump is out of the water.
Do not lift the pump by the power cord or by pulling on the cable.
The electrical supply cord of this pump cannot be replaced. If the power cord is damaged, the pump should be discarded. Never remove the plug or shorten the cable. Your guarantee is invalidated if you attempt to alter the construction of the unit in any way.
Operate the pump completely submerged for proper cooling (SP Series and VP Series when not used in-line).
Never let the pump run dry as this will damage the impeller and may also overheat the pump and burn out the electrical coil.
Never allow the water level in your water feature to fall below the top of the pump body. Do not use this product in bathrooms.
Do not use this product if the body of the unit becomes damaged, swollen or cracked in any way.
If the pump becomes noisy, replace the impeller since this is a wearable part.
Keep the connection (plug and socket) dry at all times.
The pump is NOT suitable for use in swimming pools, swimming ponds or other situations where people could make bodily contact with the water.
Infinity™ Pumps - Care & Instructions Infinity™ Pumps - Care & Instructions
PUMP BODY
IMPELLER
IMPELLER COVER
FRONT COVER
PUMP BODY
IMPELLER
IMPELLER COVER
FRONT COVER
FILTER
SP Series Parts Diagram
VP Series Parts Diagram
Page 3
Infinity™ Pumps - Care & Instructions Infinity™ Pumps - Care & Instructions
Infinity™ SP Series of Submersible Variable Flow Pumps Models SP-75, SP-130 & SP-160
Please be sure to read these instructions carefully before you begin installation and use.
1. Place the pump in a suitable location using the
rubber suction feet as additional support if possible. The unit must be fully submerged in the water since this will cool the unit.
2. Place the pump in a location where water can be
circulated around the pump.
3. Turn the flow control valve clockwise to increase
the water flow, turn the flow control valve counter­clockwise to reduce the water flow.
4. Clean the impeller at least every month. The impeller
is situated in the pump housing and can be accessed by holding the pump body and rotating the impeller cover and pulling the pump cover away from the main body.
5. Clean the impeller in fresh water and the housing
with cotton buds or similar to remove any and all accumulated debris from the pump and then re-assemble.
The electricity supply cord must extend below the plug socket; this is to prevent water drops from making contact with the plug or electricity supply outlet – this is called a “drip loop”. See diagram in the WARNING section.
Infinity™ VP Series of In-line/ Submersible Variable Flow Pumps Models VP-300, VP-600, VP-1150, VP-1650 & VP-2250
Please be sure to read these instructions carefully before you begin installation and use.
1. Place the pump in a suitable location using the
rubber suction feet as additional support if possible. Never let the pump run dry.
2. Place the pump at least 6” and no more than 36”
below the water on a stable surface that is free from sludge, sand and other debris. Allow for adequate water circulation around the pump for maximum performance.
3. Add fountain extension pipes so that the fountain
head is above the surface of the water.
4. Turn the flow control valve clockwise to increase
the water flow, turn the flow control valve counter­clockwise to reduce the water flow.
The cascading water bell nozzle (if so equipped and provided) is adjusted by turning the top piece of the head higher for a smaller bell and by turning the top piece of the head lower for a wider shaped bell.
MAINTENANCE & CLEANING
The Infinity Series of pumps do not require lubrication or special maintenance. The following maintenance and cleaning will improve your pump’s performance and life.
Carry out routine maintenance when the pump flow is visibly reduced. Switch off the electricity and remove the pump for the water source (DO NOT use the cable to lift the pump out) and firmly pull off the pre-filter cage from the pump motor (Fig. 1). Remove pre-filter foam and clean thoroughly in fresh water. A blocked foam filter will reduce the pump flow rate. Regular maintenance: remove the impeller cover by turning the in-line housing counter-clockwise while pushing in to release the lock (Fig. 2). Once unlocked, firmly pull the cover away from the pump motor (Fig. 3). Carefully remove the impeller locator (small round washer if applicable) and the impeller unit (Fig. 4). Wash parts with fresh water and clean thoroughly. Once you have cleaned the pump, re-assemble in reverse order (Fig. 5). Your actual cleaning frequency will be based on your specific use conditions.
Do not allow the pump to operate in below freezing conditions (32°F) since this will cause the pump to freeze up and become inoperable. In freezing conditions, remove the pump from the use area and store in a frost-free location.
SP Series Pump
VP Series pump
Fig. 1 - Remove pre-filter cage
Fig. 2 - Unlock impeller cover Fig. 3 - Remove impeller cover
Fig. 4 - Remove impeller unit Fig. 5 - Reassemble
Page 4
Infinity™ Pumps - Care and Instructions Technical Information
TROUBLESHOOTING
If the pump fails to operate, check the following:
Check the circuit breaker and try another outlet to insure the pump is getting electrical power. Note: Always disconnect from electrical outlet before handling the pump.
Check the pump discharge and tubing for kinks and obstructions. Algae build-up can be flushed out with a garden hose.
Check the inlet screen or filter sponge to insure it is not clogged with debris.
Remove the pump inlet to access the impeller area. Turn the rotor to insure that it is not broken or jammed.
WARRANTY
This pump is warranted to the original purchaser against defective material and workmanship under normal use for a period of three years from the date of purchase. Replacement liability in all events is limited to the repair or replacement of the pump in the sole discretion of Smart Solar Inc. which is found to be defective in material or workmanship. Proof of purchase is required on all claims in the form of a dated purchase slip affixed to the enclosed warranty registration card.
Application: This warranty covers only properly installed and maintained units. Warranty is limited to applications pumping fresh water (SP Series) or fresh water and marine water (VP series) at temperatures above 32°F and below 86°F (0°C – 30°C), with a pH range of 5 to 9. Other liquid applications and extreme temperature uses void this warranty.
Claims handling: All USA warranty claims should be made by returning the defective pump, freight prepaid along with a copy of the completed warranty registration card to Smart Solar. Please call 813-343-5775 to obtain a return authorization and the location of the service center nearest to you. All returned items will be inspected to determine the cause of failure before warranty is approved. Removal charges: This warranty does not cover any costs associated with the installation, removal or re-installation of any products subject to warranty claims.
Disposition: Smart Solar will promptly handle your claim and advise you of disposition generally within 72 hours of receipt. In the event of products damaged in transit, Smart Solar will advise you and you will need to file a claim with the sending carrier.
Disclaimer: Any oral statements about the product(s) made by the seller, the manufacturer, the representatives or any other parties do not constitute warranties, are not part of the contract for sale and are not to be relied upon by the user. Seller’s and manufacturer’s sole obligation, and buyer’s and user’s only remedy shall be for Smart Solar to either repair or replace, at Smart Solar’s sole discretion, the Infinity pump product as described above. Neither seller or Smart Solar shall be liable for any injury, loss or damage, direct, incidental or consequential (including, but not limited to, incidental or consequential damages for lost profits, lost sales, personal injury, property damage, or any other incidental or consequential loss not specifically mentioned herein), arising from any cause whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them. Smart Solar shall not be held liable for the loss of any fish, plants or other livestock as a result of any failure or defect of this product. Before using, the buyer and user shall determine the suitability of the product for the intended use, and assumes all risk and liability whatsoever in connection therewith. The warranty and remedy described in this limited warranty is an EXCLUSIVE warranty and remedy and IN LIEU of any other warranty or remedy, expressed or implied, which other warranties and remedies are hereby expressly EXCLUDED, including but not limited to any implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. This warranty gives the buyer and the user specific legal rights, and the buyer and the user may also have other rights which vary from state to state. Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation may not apply to you.
Limitation: This warranty specifically excludes the sponge filter and the impeller unit, which are normal wear items and may require annual replacement depending on actual usage conditions. If you require replacement for these parts, please contact your dealer or Smart Solar directly at 813-343-5775.
VP Series in-line and submersible pump – Ceramic shaft, magnetic drive, sealed epoxy
Max Cable STI Max Min Height Length Impeller Fresh Salt Model Watts GPH GPH (feet) Outlet (feet) Shaft Water Water
VP-300 17 300 175 6.50 1/2” 16 Ceramic Y Y 3/4”
VP-600 40 600 250 7.50 1/2” 16 Ceramic Y Y 3/4”
VP-1150 70 1,150 300 9.0 0 3/4” 16 Ceramic Y Y 1”
VP-1650 145 1,650 500 12.50 3/4” 16 Ceramic Y Y 1”
VP-2250 226 2,250 550 16.50 3/4” 16 Ceramic Y Y 1” 1-1/4 ”
SP Fountain Series submersible pump – Stainless steel shaft, magnetic drive, sealed epoxy
SP-75 5.5 75 35 1.50 3/8” 6 Stainless Y N Steel
SP-130 10 130 45 4.30 3/8” 6 Stainless Y N 1/2” Steel
SP-160 13 160 50 5.50 3/8” 6 Stainless Y N 1/2” Steel
Page 5
SP-75 / SP-130 SP-160 VP-300
VP-600
Attachments included with the
SP-75 and SP-130 Pumps:
#1 - Connector #2 - Connector
#1
#2
Attachments included with the
SP-160 Pump:
#1 - Connector #2 - Connector #3 - Connector
#4 - Single Volcano Nozzle
#5 - Water Bell Nozzle
#6 - Flow Control #7 - Raising Pipe
Attachments included with the
VP-300 Pump:
#4 - Single Volcano Nozzle
#8 - Flow Control
#9 - Water Bell Nozzle #10 - Long Raising Pipe #11 - Long Raising Pipe #12 - Short Raising Pipe
#13 - Water Inlet #14 - Water Outlet
#15 - Water Outlet
#4
#5
#6
#7
#4
#8
#9
#10
#11
#12
#13
#14
#15
Attachments included with the
VP-600 Pump:
#14 - Water Outlet #15 - Water Outlet
#16 - Water Bell Nozzle
#17 - Double Volcano Nozzle
#18 - Single Volcano Nozzle
#19 - Flow Control #20 - Flat Cover
#21 - Water Outlet #22 - Water Outlet
#23 - Water Intake Inlet
#14 #15
#16 #17 #18
#19
#20
#21
#22
#23
NOTE: All attachments pictured are
not shown in proportional scale with attachments in the other photos. They are shown for easy identification only.
#3
#1
#2
Page 6
VP-1150
VP-2250
Attachments included with the
VP-2250 Pump:
#20 - Flat Cover
#21 - Water Outlet #22 - Water Outlet
#29 - Cascade Bell Insert for Narrow Bell Shapes
#30 - Cascade Bell with Large Bell Shape Insert
#31 - Volcano Nozzle
#32 - Water Intake Inlet #33 - Flow Control #34 - Water Outlet #35 - Water Outlet #36 - Water Outlet
Attachments included with the
VP-1650 Pump:
#16 - Water Bell Nozzle
#17 - Double Volcano Nozzle
#18 - Single Volcano Nozzle
#20 - Flat Cover
#21 - Water Outlet #22 - Water Outlet
#24 - Water Intake Inlet
#25 - Flow Control
#26 - Water Outlet #27 - Water Outlet
#28 - Foaming Nozzle
#28 #17 #18 #16
#23
#24
#25
#26 #27
#20
#21
#22
#30
#29
#31
#32
#33
#34
#35 #36
VP-1650
Attachments included with the
VP -1150 Pump:
#14 - Water Outlet #15 - Water Outlet
#16 - Water Bell Nozzle
#17 - Double Volcano Nozzle
#18 - Single Volcano Nozzle
#19 - Flow Control #20 - Flat Cover
#21 - Water Outlet #22 - Water Outlet
#23 - Water Intake Inlet
#14 #15
#16 #17 #18
#19
#20
#21
#22
#23
#20