SMA SUNNY MINI CENTRAL 4600A, SUNNY MINI CENTRAL 5000A, SUNNY MINI CENTRAL 6000A User Manual

SMC46-60A-BA-BEN111320 | IME-SMC50A_60A | Version 2.0
EN
PV Inverter
SUNNY MINI CENTRAL 4600A/5000A/6000A
User Manual
Installer contact
ES
Operation display.
Ground fault or varistor defective. Please inform your installer.
An error has occurred. Please inform your installer immediately.
Tap to switch on the display light and switch to the next message.
Symbols on the Type Label
Beware of dangerous electrical voltage. The inverter operates at high voltages. All electrical work on the inverter may be
carried out by quali󹻭ed personnel only.
Beware of hot surface. The inverter can become hot during operation. Avoid contact during operation.
Observe the enclosed documentation.
The inverter must not be disposed of with the household waste. Further disposal information can be found in the enclosed installation guide.
CE mark. The inverter complies with the requirements of the applicable EC guidelines.
RAL quality mark for solar products. The inverter complies with the requirements of the German Institute for Quality Assurance and Labeling.
Direct Current (DC)
Alternating Current (AC)
The inverter is protected against penetration by dust particles and water jets from any angle.
The inverter has a transformer.
AC
Abbreviation for "alternating current".
DC
Abbreviation for "direct current".
Derating
A controlled reduction in performance, usually dependent on component temperatures.
Electronic Solar Switch (ESS)
The Electronic Solar Switch is part of the inverter's DC disconnection unit. The Electronic Solar Switch must be securely inserted into the bottom of the inverter and may
only be removed by quali󹻭ed personnel.
Grid impedance
The grid impedance is a characteristic grid speci󹻭cation, which is determined both by the grid
infrastructure, and by the number of power suppliers and power consumers. If the supply for the grid section should drop due to a grid shutdown of the preceding energy suppliers (medium-voltage transformers), the grid impedance will change abruptly. In order to detect this and to prevent the formation of an unwanted off-grid system, SMA Grid Guard monitors the grid impedance and disconnects the inverter from the grid in the event of a sudden impedance variation.
MPP (Maximum Power Point)
Operational point of the inverter, dependent on current/voltage of the PV generator. The actual position of the MPP changes constantly, depending on the level of solar irradiation and the cell temperature.
PV
Abbreviation for photovoltaics.
SMA Power Balancer
The SMA Power Balancer prevents the formation of an unbalanced load > 5kVA (in Italy > 6kVA) during three-phase grid feed-in. To this effect, 3 Sunny Mini Centrals are each connected via a control line to a 3-phase feeding unit.
Unbalanced load
The unbalanced load is the difference between the power fed into the grid at the individual line conductors. In Germany, this must not exceed 5 kVA. In Italy, the unbalanced load is restricted to 6 kVA.
Varistor
The varistors protect the electronics in the inverter from atmospherically coupled energy peaks, such as those that can occur when lightning strikes nearby.
EXPLANATION OF SYMBOLS GLOSSARY
CONTACT
If you have technical problems, 󹻭rst contact your installer. The following information is required in
order to provide you with the necessary assistance:
Inverter device type
Inverter serial number
Type and number of PV modules connected
Blink code or display message of the inverter
Optional equipment (e.g. communication devices)
SMA Solar Technology AG
Sonnenallee 1 34266 Niestetal, Germany www.SMA.de
SMA Serviceline
Inverters: +49 561 9522 1499 Communication: +49 561 9522 2499 Fax: +49 561 9522 4699 E-Mail: Serviceline@SMA.de
Visual Inspection
Check the inverters and the cables for visible external damage. Contact your installer if you 󹻭nd any
defects. Do not perform any repair work yourself.
Maintenance and Cleaning
Ask your installer to check for proper inverter operation at regular intervals.
VISUAL INSPECTION, MAINTENANCE AND CLEANING
If your inverter is equipped with a communication component, then numerous measuring channels and messages can be transmitted for diagnosis.
Measuring channel Description
Balancer Displays the currently active operating mode of the inverter which is set
under the operating parameter "PowerBalancer".
dZac Change of the grid impedance
Error Identi󹻭cation of the current disturbance/error.
E-total Total amount of energy fed into the grid
Event-Cnt Number of events that have occurred
Fac Grid frequency
h-On Total number of operating hours
h-total Total number of operating hours for feeding operations
Iac Grid current
Ipv DC current
Mode Display of the current operating mode
Pac Generated AC power
Power On Total number of grid switch-ons
Riso Insulation resistance of the PV system to the grid connection
Serial number Inverter serial number
Vac Grid voltage
Vpv PV input voltage
Vpv-Setpoint PV target voltage
Your inverter can be in various operating modes. These are displayed as status messages, which can vary according to the method of communication.
Message Description
Balanced The inverter has disconnected itself from the grid, or is limiting its output to
5 kVA over a 10 minute average. The inverter is part of a three-phase system with two further inverters and equipped with the Power Balancer for preventing asymmetric loads.
Derating Overtemperature in the inverter. The inverter will reduce its output to prevent
overheating. To avoid unnecessary output losses, the design of the system should be checked. Please inform your installer.
Disturbance Disturbance. This message appears for safety reasons and prevents the inverter
from connecting to the grid. Please inform your installer. Error An error has been detected. Please inform your installer. grid mon. Grid monitoring.
This display appears during the start phase, before the inverter is connected to
the grid, predominantly in the mornings and evenings when the solar irradiation
is low and after an error. MPP The inverter is operating in MPP mode. MPP is the standard display message
when operating under normal irradiation conditions. MPP Peak The inverter is operating in MPP mode above its nominal power. MPP-Search The inverter is calculating the MPP. Off Grid The inverter is in "Island" mode. This mode is specially designed for operation in
an off-grid system. offset Offset adjustment of measurement electronics. Riso Measurement of the insulation resistance of the PV system. Stop Interruption of operation. V-Const Constant voltage operation. waiting The switch-on conditions are not (yet) ful󹻭lled.
DANGER!
Electric shock caused by high voltage in the inverter.
Even when no external voltage is present, there can still be high voltages in the device.
The following work may be carried out by quali󹻭ed personnel only:
Electrical installation
Repairs
• Modi󹻭cation
CAUTION!
Risk of injury from touching the enclosure during operation. Burns to the body.
Only touch lid and display during operation.
NOTICE!
Overvoltage in the inverter if yellow LED 󹢵ashes 4 times.
Destruction of the inverter.
Inform your installer immediately if the yellow LED starts 󹻮ashing and the following display message appears.
Operation
The display shows current values of your system. The displayed values are updated every 5 seconds. The display is operated by tapping on it.
Tap once
The background illumination is switched on. After 2 minutes, the illumination switches off automatically.
Tap again
The display switches to the next message.
Display messages
In operation
Upon error-free connection of the inverter to the grid, the following
noti󹻭cations are shown in turn after approximately one minute. Each noti󹻭cation appears for 󹻭ve seconds, then the cycle starts again.
Power produced on the current day Operating condition
Current feed-in power Voltage of the PV generator
Total amount of feeding-in energy Total number of operating hours for feeding operations
Disturbance
In the event of a disturbance, the inverter will display the status "Disturbance" and an error message. Please inform your installer.
The following noti󹻭cations will be issued:
Power produced on the current day Operating condition "Disturbance"
Operating condition Error message
Measured value at time of disturbance Current measured value (only displayed if a measured value is responsible for the disturbance)
DC overvoltage
The DC input voltage connected to the inverter is too high. Please inform your installer immediately.
State Designation Function
All LEDs are onInitialization The inverter is initializing.
All LEDs are off
Deactivation The input voltage at the inverter is too low for grid
feeding.
Green LED is permanently on
Feeding operation
The inverter is feeding power into the public grid.
Green LED is
󹻮ashing
Waiting, grid monitoring
The inverter is monitoring the grid and is waiting for the DC voltage to reach a certain level so that it can start feeding the grid.
Stop Interruption of operation.
Derating Power limitation in the inverter.
Red LED is onError A ground fault has occurred or one of the thermally-
monitored varistors on the DC input site is defective. Please inform your installer.
Yellow LED is on continuously
Disturbance The inverter is operating in "Operation constantly
disabled" mode. This can have several causes. Please inform your installer.
Yellow LED is
󹻮ashing
Disturbance The inverter is indicating a disturbance. This can
have several causes. Please inform your installer.
LED MODES
SAFETY PRECAUTIONS PRODUCT OVERVIEW
Air grills
Enclosure lid
Display
LEDs
Serial number
Identi󹻭cation of the Sunny Mini Central by the type label
In operation
Ground fault or varistor defective
Disturbance
DISPLAY
STATUS MESSAGESMEASURING CHANNELS