INSTALLATION INSTRUCTIONS FOR OPTIMA SENSOR ACTIVATED LAVATORY
FAUCETS WITH THE OPTIMA CONTROL BOX
DECK MOUNTED OPTIMA FAUCETS
Code No. 0816843
Rev. 1 (06/18)
ETF-600 Low-height, hardwired
EBF-650 Low-height, battery
ETF-610 Low-height,hardwired
EBF-615 Low-height, battery
GOOSENECK DECK MOUNTED OPTIMA FAUCETS
ETF-770 Hardwired with
side sensor
EBF-775 Battery with
side sensor
ETF-700 Hardwired
EBF-750 Battery
ETF-700-S Hardwired
with surgical bend
EBF-750-S Battery
with surgical bend
CONTROL BOX FOR ALL FAUCETS
ETF-660 Low-height,
hardwire with side sensor
EBF-665 Low-height,
battery w/side sensor
WALL MOUNTED OPTIMA FAUCETS
ETF-500 Hardwired
EBF-550 Battery
ETF-80 Mid-height, hardwired
EBF-85 Mid-height, battery
ETF-500-S Hardwired
with surgical bend
EBF-550-S Battery
with surgical bend
ETF-880 Mid-height, hardwired
EBF-187 Mid-height, battery
ETF-800 Hardwired
EBF-850 Battery
Control Box w/o Turbine
TABLE OF CONTENTS
• Prior to install...............................................2.
• Mixing valve installation................................2.
• Important.................................................... 2.
• Quick connect tee........................................2.
• Tools required..............................................2.
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship
for a period of three (3) years (1 year for SF faucets, special finish and PWT electronics and 30 days on PWT software) from date of first purchase. During this period, Sloan Valve
Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole
and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs.
This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does
not cover the life of the battery.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES
OF ANY MEASURE WHATSOEVER.
Control Box w/ 0.5 gpm Turbine
LIMITED WARRANTY
1
Control Box w/1.5 gpm Turbine
• Deck mounted rough-in...................................4.
• Wall mounted rough-in.................................. 5.
• Dimensional Data.......................................... 5.
• Troubleshooting instructions.............................7.
• Care and cleaning instructions ........................8.

PRIOR TO INSTALLATION
Prior to installing the Sloan Optima Faucet, install the items listed below. Also, refer to rough-in illustrations on pages 4 and 5.
• Lavatory/sink
• Drain line
• Hot and cold water supply lines or pre-tempered water supply line
MIXING VALVE
When installing the faucet with a Sloan mixing valve, these Installation Instructions AND the Installation Instructions packaged with the mixing valve
MUST be followed.
IMPORTANT
• ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.
• FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
• KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON
COMPRESSION FITTINGS.
QUICK CONNECT BAK CHEK® FILTER TEE USAGE
A QUICK CONNECT BAK-CHEK® FILTER TEE MUST BE USED WITH EACH INSTALLATION.
When connecting a Sloan Optima Faucet to both hot and cold water supplies, a two inlet Quick Connect Bak-Chek® Filter Tee is provided and
required as Illustrated. Water temperature can be controlled by adjusting the supply stops. When connecting the faucet to a single line water supply or
a pre-tempered water supply, a single inlet Quick Connect Bak-Chek® Filter Tee must be used. A Quick Connect Bak-Chek® Filter Tee must also be
used when a Temperature Mixing Valve is included with the faucet.
TOOLS REQUIRED FOR INSTALLATION
Gather the required tools and parts before starting installation. Additional parts may be required, depending on your installation. Check local codes.
Check existing electrical supply.
1. Open end wrenches for hex sizes: 1/2”,
2. Basin wrench 3. Phillips head screwdriver, #2
9/16”, 5/8”, 15/16”
4. Hammer (if installing plastic or hollow wall
anchors to mount valve module)
5. 1/4” drill bit (if plastic wall anchors are
used to mount valve module)
6. 5/16” drill bit (if hollow wall anchors are
used to mount valve module)
7. 3/8” drill bit (if toggle nut anchors are
used to mount valve module)
8. Spray head key
(supplied with some models)
2

Stops
Stops
Stops
Thermostatic
Mixing Valve
Mechanical
Mixing Valve
Y-Filter
Flexible
Supply
Hose
Flexible
Supply
Hose
Flexible
Supply
Hose
Faucet
Faucet
Faucet
Single Inlet
Filter Assembly
Single Inlet
Filter Assembly
Manifold
Assembly
Quick Connect
Clip
Stops
Stops
Quick Connect
Clip
Quick Connect
Clip
Assembly
Quick Connect
Clip
Quick Connect
Clip
Quick Connect
Clip
Manifold
Assembly
Manifold
Assembly
Stops
Stops
Stops
Thermostatic
Mixing Valve
Single Inlet
Filter Assembly
Quick Connect
Clip
Quick Connect
Clip
Stops
Stops
Thermostatic
Mixing Valve
Flexible
Supply
Hose
Faucet
Single Inlet
Filter Assembly
Quick Connect
Clip
Quick Connect
Clip
Manifold
Assembly
MANIFOLD INSTALLATION
A. Ensure there is enough clearance for the exible supply hose from
the spout to connect to the control module
B. Secure control module to wall using the included mounting
accessories. The control module must be mounted on a level
Anchors
Mounting Slot
Access
Stainless Steel
Quick Connect Clips
Screws
vertical surface with the Sloan logo on the manifold facing
outwards on the top right side of the manifold. Do not mount the
Solenoid
manifold in any other position.
C. Insert the exible supply hose from the bottom of the spout into
the top of the mounted manifold.Insert the Filter “T” tting into
the bottom of the mounted manifold. Ensure that the stainless
nchors
steel clips on both the top and bottom of the manifold are secured.
NOTE: NEVER OPEN STAINLESS STEEL CLIPS WHEN WATER
Stainless Steel
Quick Connect Clips
Quick Change
Manifold Cover Assembly
SUPPLY IS TURNED ON.
NOTE: FOR UNITS WITH TURBINES, USE ONLY 0.5GPM / 1.9 LPM CONTROL BOXES WITH SPOUTS RATED FOR THE SAME FLOW AND USE
ONLY 1.5 GPM / 5.7 LPM CONTROL BOXES WITH SPOUTS RATED FOR THAT SAME FLOW. DO NOT USE THESE CONTROL BOXES ON
ANY OTHER FLOW RATES. CONTROL BOXES WITHOUT TURBINES MAY BE USED WITH ANY SPOUT UP TO 2.2 GPM / 8.3 LPM
D. Connect water supply lines from the stops to the Filter “T” tting. If a mixing valve is being used, connect water supply lines to the mixing valve.
Connect the mixing valve to the single inlet lter tee using the supplied tting.
E. Attach sensor cable and solenoid cable to the appropriate connections on the manifold.
F. Insert the battery assembly.
G. This unit can use batteries alone, or accept 6 VDC or 24 VAC power to function as a hardwired unit with battery back up.
H. If a 6 VDC plug-in transformer is used, plug it into the appropriate connection on the manifold to convert the faucet into a “plug-in with battery
back-up”.
I. If 24 VAC hardwires are being used, use the supplied adapter piece to connect the wires to the appropriate connection on the manifold.
J. If the unit contains an optional turbine, connect the plug from the turbine assembly into the appropriate connection on the manifold.
K. If ganging multiple units in a “daisy chain” conguration to a single power supply use the SFP35 gang adapter kit.
L. Inspect and tighten all connections. Place the manifold cover onto the unit.
M. Turn on water.
BELOW DECK CONFIGURATION
Control Module with
Double Inlet Tee Filter
Assembly.
Quick Connect
Clip
Single Inlet
Filter Assembly
Mechanical
Mixing Valve
Stops
Faucet
Manifold
Assembly
Control Module with Single
Inlet Tee Filter Assembly
and Below Deck Manual
Mixing Valve (BDM)
3
Flexible
Supply
Hose
Quick Connect
Clip
Stops
Control Module with Single
Inlet Tee Filter Assembly
and Below Deck Thermostatic
Mixing Valve (BDT)