RATINGS CHART – OIL BOILERS
XL-2000
BOILER MODEL
NO.
I=B=R
BURNER
CAP
ACITY
OIL INPUT
GPH BTUH
§
D.O.E.
HEATING
CAPACITY
MBH
*
WATER
I=B=R
WATER
NET
RATING
MBH
*
NOM. RECT X HEIGHT (in x in x ft)
I=B=R
CHIMNEY SIZE
I.D. ROUND
X HEIGHT
(in x ft)
AFUE %
WATER
BOILER
LENGTH
XL-20 0.65 91,000 78 68 8 x8x15 6 x 15 83.56 8
XL-30H 0.85 119,000 104 90 8 x8x15 6 x 15 86.00 12
XL-30 1.00 140,000 121 105 8 x8x15 6 x 15 85.04 12
1.15 161,000 138 120 8 x8x15 6 x 15 84.12 12
XL-40H 1.25 175,000 152 132 8 x8x15 7 x 15 86.00 15
XL-40 1.35 189,000 162 141 8 x8x15 7 x 15 85.05 5
1.55 217,000 186 162 8 x8x15 7 x 15 84.38 5
XL-50 1.80 252,000 217 189 8 x8x15 8 x 15 85.00 19
2.00 280,000 239 206 8 x8x15 8 x 15 84.19 193⁄16"913⁄16"8" 11⁄2"35
Standard working pressure 30 psi. All boilers h *
† Ratings apply to the use of light oil at 140,000 Btu per gallon and apply only with Slant/Fin
ydrostatically tested — A.S.M.E. For forced hot water heating systems where the boiler and all piping are located within the area to be heated, the boiler may be selected on the basis of gross D.O.E. capacity output. The net I=B=R output ratings shown are based on an allowance for piping and pickup of 1.15. D.O.E. heating capacity is divided b Service Department should be consulted before selecting a boiler for unusual piping and pick­up requirements such as inter
y the allo
wance to obtain net rating. The Slant/Fin Technical
mittent system operation, extensive piping, etc.
supplied burners properly adjusted to produce 13% CO
‡ Nominal clay tile liner dimensions.
§ Boiler models XL-30 and larger have two firing rates. The boiler is factory shipped at the lower firing rate. To obtain the higher firing rate, refer to the XL-2000 boiler installation instructions for the appropriate field adjustments.
¶ Oblong flue collar. Fits 6" dia. vent connectors. NOTE: All boilers under 300,000 Btuh input are tested and rated for capacity under the U.S. Department of Energy (D.O.E.) Test Procedures for Boilers.
FRONT
TO
FLUE
“A”
1
1
16" 49⁄16" 6" 1
3
3
16"65⁄16"6" 1
3
16" 65⁄16" 6" 11⁄4" 287⁄8"
11
11
16" 81⁄16" 7" 11⁄4" 323⁄8"
11
16" 81⁄16" 7" 11⁄4" 323⁄8"
3
16"913⁄16"8" 11⁄2"35
“B”
6"65⁄16"6" 1
16" 81⁄16" 7" 11⁄4" 323⁄8" 482
2
.
FLUE
COLLAR
DIA.
“C”
CIRCULATOR
SUPPLY
FLANGE “D”
NPT
1
4" 253⁄8" 304
1
4"28
1
4"28
APPROX.
OVERALL
LENGTH
“E”
7
8" 382
7
8"
7
8"
7
8"
SHIPPING
WEIGHT
(lbs.)
382
482
538
DISCONTINUED MODEL
SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600
FAX: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com