Skytech II AF 4000PEHH Users manual

Draft
z Button
Function Dscription
AUX1 button
Use this key to enter into & set Program mode
set timer & cancel timer function
On/Off button for Manual mode
AUX2 button
Thermo mode
A long push (5 seconds) of A1 & A2 buttons at the same time will start the Initial Set-up. At this time, a separate push for A1 &A2 buttons does not light any operations on the
LCD.
A short push of P button will enter into PROGRAM mode. A long push (5 seconds) of P button will enter into the setting for PROGRAM mode.
*A long push (5 seconds) of TIMER & THERMO mode at the same time will activate or de-activate the CP feature.
Draft
z LCD icon:
Set temperature thermo
Timer
Manual ON
Program
Thermostat
Thermostat NOT
Pacific energy company icon
Set Temperature: This will ONLY appear when the THERMOSTAT is activated
- Timer: Timer Mode will appear and activate the Timer.
Battery low
Flame UP
FLAME
Flame down
AUX1
AUX2
Program mode setting and display area
CP:Chil d Proof
- Manual ON: When manual ON , the MAN Icon will appear and when manual OFF the MAN icon will be eliminated
- Program Mode: This icon will appear when the program is working
- Thermostat : This icon will appear only when the Thermostatic Function is operating the fireplace.
- Thermostat NOT : Tthis icon will ONLY appear(for 5 seconds) on the LCD screen when the Thermostatic function has been de-activated and someone will try to push the Thermostatic function button of the transmitter. This will show the user the thermostatic function is de-activated.
Draft
Notes:
The range for the room temperature readout is 32-99 degree F.
The room temperature always displays on the LCD. The range for set temperature is 45- 99 90degree F. The High Limit temperature for PROGRAM mode is 90 degree F.
This High Limit termperature can not be changed by the users and
Will only activate under PROGRAM mode. There is no High
Limit temp for MANUAL & THERMO modes.
The room temperature ( ) always displays on the LCD
The AUX1 and AUX 2 ( ) do not light any operations on the LCD at this time.
NOTE: Very Important to note
Only one function can be going on at one time. You will have only one operation at a time going on with this system. The pressing of one of the function buttons will stop the operation that is going on with the fireplace and start the new function.
Definition of Functions: Timer, Manual ON/OFF, Thermostat, and Program.
Timer” is considered an independent function.
The users are unable to set “Timer” function under Manual & Thermo modes.
The users can adjust the Flame (operate the motor drive) under Manual ON,
THERMO, TIMER & PROGRAM modes.
SWING:
Pacific Energy after discussion would like to have the following in the swing without the user having the ability to adjust this swing in any way.
- Above the Room Temperature 1degree F and .5 degree C, 1 degree swing above
- Below the Room Temperature 2 degree F and 1 degree C, 2 degree swing down
THESE SETTING CANNOT BE CHANGED, IT IS SET AT THE FACTORY AND IN THE PROGRAM. It is not necessary to display SWING on the LCD..