Operating Instructions
How to Use the SKC Preloaded Coated Filters
863 Valley View Road, Eighty Four, PA 15330
Tel: 724-941-9701 Fax: 724-941-1369
www.skcinc.com
Preloaded Coated Filters
Cat. No. 225-9009
SKC coated fi lters are shipped preloaded in the cassettes with end plugs and shrink bands in place. No assembly is required; they are ready to use.
Method & Chemical: OSHA 82 for acetic anhydride
Filter & Coating: 2 glass ber lters coated with 1-(2-pyridyl) piperazine.
Four-piece 37-mm cassette. Closed-face sampling confi guration
Sample Stability: Store samples at 39.2 F (4 C) for up to 15 days.
For information on other available
coated fi lters, request SKC Publication 1219.
1. Select one coated fi lter cassette for calibrating the fl ow rate. A red plug secures the inlet, which is clearly marked “inlet,” and a blue plug secures the outlet. Set up the sampling train for calibration with the representative fi lter cassette in line. For “closed-face” sampling, remove the plugs and connect the cassette to the sampling train. For “open-face” sampling, remove the outlet plug and the cassette inlet section then connect the cassette to the sampling train. For details on setting up a sampling train, refer to the SKC Sample Setup Guide “Sampling Train - Filters and Cyclones” (SKC Publication 1166).
2. Calibrate the pump to the desired fl ow rate using a fi lm fl owmeter or calibrated precision rotameter. For details on calibrating a pump, refer to the SKC Sample Setup Guide “Calibrating a Pump Using a Film Flowmeter” (SKC Publication 1163).
3. Replace the cassette used for calibration with a fresh coated fi lter cassette for sample collection. Attach the cassette to a worker’s collar, as close to the breathing zone as possible, by using a fi lter cassette holder (SKC Cat. No. 225-1). Sample for the specifi ed time interval and record the time.
4. Remove the fi lter cassette at the end of the specifi ed sampling period and replace both end plugs (and the inlet if necessary). Recheck the fl ow rate using the same cassette and fl owmeter used for calibration (in Step 2) to ensure that the fl ow rate has not changed by more than 5%.
5. Store samples at 39.2 F (4 C) for up to 15 days. Appropriately package samples, blanks, and all pertinent data to send to a lab for analysis. Expedite shipping of samples to laboratory. Friday shipments are not recommended.