DPM Cassette with Impactor
Catalog No. 225-317
SKC Diesel Particulate Matter Cassettes are designed for sampling in atmospheres where it is necessary to separate DPM from other respirable dust (such as coal dust). Single-use SKC DPM Cassettes are tamper-evident sealed to ensure sample integrity. Each streamlined plastic cassette comprises an impactor with precision sapphire orifice, impaction substrate, and two heat-treated quartz filters. The impactor screens out respirable particles 1.0 μm. Particles less than 1.0 μm are collected on the filter. Samples are analyzed for organic and elemental carbon content using a highly sensitive Evolved Gas Analysis (EGA) technique with thermal-optical analyzer as specified in NIOSH 5040.
www.skcinc.com
Plug
Outlet
Support pad
Heat-treated quartz fi lter
Heat-treated quartz fi lter
Stainless steel ring (defi nes fi lter area)
Impactor assembly
Cassette body
Inlet
Plug
Performance Profi le
Casse e Size: 37 mm Filter: Two heat-treated quartz fi ber
Figure 1. Exploded view of
DPM Cassette
(Cat. No. 225-317)
with cellulose support pad Filter Collection Area: 8.04 cm
2
Impactor: Four-nozzle, precision sapphire orifi ces Flow Rate: Calibrated at 1.7 and 2.0 L/min for sampling of sub-micron
particles
Analysis: For organic and elemental carbon using evolved gas analysis
(EGA) with thermal-optical analyzer (NIOSH Method 5040)
Sampling Equipment
The SKC DPM Casse e is designed for use with an appropriate sample pump and cyclone that pre-selects non-respirable particles*. An SKC Universal XR, AirChek® 2000, or AirChek XR5000 sample pump can provide the specifi ed fl ow rate. Use the SKC Casse e/Cyclone Holder (Cat. No. 225-1) to secure the casse e when used with the GS-1 Cyclone.
* A cyclone is not necessary in all sampling situations. It should be used in se ings where larger particulate is likely to clog
the impactor.
Setting Up the Sampling Train with Cyclone and Holder
1. Insert stem of GS-1 Cyclone into large hole in casse e holder.
2. Orient cyclone in holder until the small round nodule on the bowl adapter rim fi ts into the notch in the casse e holder.
3. Remove inlet and outlet plugs from a DPM Casse e, pull back spring-loaded hold-down plate on casse e holder, and gently push inlet of casse e onto top of cyclone.
4. Position small hole in hold-down plate over casse e outlet.
5. Insert Luer adapter on the holder's rubber tubing into casse e outlet.
AIRCHEK
Figure 2. DPM Sampling Train with GS-1 Cyclone,
Cassette Holder, and Universal PCXR4 Pump
SAMPLER
SAMPLE PERIOD — MINUTES
START
HOLD
U
LISTED 124U
5
L
®
INTRINSICALLY SAFE PORTABLE AIR SAMPLING PUMP FOR USE IN HAZARDOUS LOCA TIONS CLASS I, GROUPS A B C D
4
AND CLASS II, GROUPS E F G
FLOW
AND CLASS III, TEMPERATURE
AND
CODE T3C.
BATTERY CHECK
ON
FLOW
ADJ
AIRCHEK SAMPLER MODEL 224-PCXR8
WARNING - SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRIN SIC SAFETY. USE ONLY UL LISTED PORTABLE AIR SAMPLING PUMP BATTERY PACK MODEL P21661
SERIAL NO. SKC INC. EIGHTY FOUR PA 15330
3
2
1
Setting Up the Sampling Train without a Cyclone
1. Remove the plug from the outlet of the casse e (Figure 1).
2. A ach one end of a length of Tygon® tubing to the casse e outlet and the other end to the inlet of an air sample pump capable of maintaining the desired fl ow rate.
3. Secure the casse e on a worker by using a cable tie and collar clip.
4. Remove plug from the casse e inlet immediately before sampling.