SKC recommends a minimum service interval of one year for this product. The first service is due one year from the date of purchase, and then at yearly intervals on this date. However, it is the responsibility of the user to perform a risk assessment to determine the necessary frequency of servicing that is required.
Service Date Service Date Service Date
159
2610
3711
4812
Please note that SKC Ltd are the only authorised service centre in the UK, guaranteeing you access to the full range of genuine SKC replacement parts. For all other areas a full list of SKC approved distributors and service centres can be found at www.skcltd.com
SKC UK service centre - Tel: +44 (0)1258 480188 Fax: +44 (0)1258 480184 Email: info@skcltd.com
www.skcltd.com 210-PMTXM Issue L Page 1
Contents
Intrinsic Safety Information .............................................................................................................................2
Specifications ................................................................................................................................................3
General Information .......................................................................................................................................8
Diagram of the Pocket Pump .......................................................................................................................10
Pocket Pump LCD Screen ...........................................................................................................................11
Getting Started ............................................................................................................................................ 12
Operating the Pocket Pump in Constant Flow Mode ...................................................................................17
Operating the Pocket Pump in Constant Pressure Mode .............................................................................20
Through Flow Sampling with the Twin Port Pocket Pump ............................................................................22
Troubleshooting ...........................................................................................................................................26
Care of the Battery Pack ..............................................................................................................................28
Pocket Pump MTX Components .................................................................................................................30
Pocket Pump MTX Replacement Parts ........................................................................................................31
Pocket Pump Accessories ...........................................................................................................................32
Pocket Pump DataTrac Software .................................................................................................................34
Intrinsic Safety Certification ..........................................................................................................................36
Warranty Information ...................................................................................................................................52
Page 2 210-PMTXM Issue L www.skcltd.com
Intrinsic Safety Information
The Pocket Pump MTX air sampling pump range
Complies with the EU ATEX Directive 2014/34/EU on equipment intended for use in potentially explosive atmospheres, as intrinsically safe to Ex ia M1 and Ex ia IIB T4, for use in Europe.
EC type examination certificate: INERIS 03 ATEX 0177X.
European (EN) standards applied: Refer to Intrinsic Safety Certification on pages 36 to 50.
The equipment may be used in zones 0, 1 and 2 with flammable gases and vapours with apparatus groups
II
A & IIB and with temperature classes T1,T2,T3,T4.
The equipment is only certified for use in ambient temperatures in the range -20 to +40°C and should not be used outside this range.
The battery pack should not be charged in a hazardous area.
Use only SKC approved chargers designated for the model.
Do not connect to the DataTrac PC interface port whilst in a hazardous location.
The equipment has not been assessed as a safety related device (as referred to in Directive 2014/34/EU Annex II, clause 1.5).
• The equipment should not be used if damaged in a way that could invalidate intrinsic safety. Such defects might include cracking of the battery pack enclosure and internal encapsulant such that internal components or cells are exposed. It is the responsibility of the user to ensure that the pump is in an acceptable condition for use in hazardous locations.
Important note about intrinsic safety
If you are unsure as to whether the Universal pump you have purchased is suitable for your environment, check with your site manager or responsible person BEFORE USE that the intrinsic safety rating on the product meets your site requirements. SKC personnel are unable to recommend the appropriate safety rating for your site.
www.skcltd.com 210-PMTXM Issue L Page 3
Specifications
All models
Weight: 170 g
Casing IP rating: IP20
Constant Flow Mode:
1) Flow range: 20 - 225 ml/min
2) Compensation range: 0 - 20 inches of water at 20 - 225 ml/min flow
3) Flow compensation accuracy: ±5% of flow set point
Constant Pressure Mode:
1) Pressure range: 1 - 20 inches of water
2) Pressure control accuracy: ±0.5 inches of water (±0.25 mmHg)
Timer display: 0 to 9999 minutes
Timer accuracy: ±1%
Battery pack: NiMH rechargeable, 1.0 Ah, 2.4 V
Charging time: up to 6 hours (battery fitted to pump) / up to 16 hours (battery only)
Charging temperature: 0 to +45°C
Storage & operating temperature: -20°C to +40°C
Operating humidity: 0 to 95% RH
55mm 35mm
112.5mm
Page 4 210-PMTXM Issue L www.skcltd.com
Specifications
Typical run times:
Back Pressure
Run Time
Flow = 20 ml/min Flow = 100 ml/min Flow = 200 ml/min
10 inches of water 14 hours 13 hours 11 hours
20 inches of water 12 hours 12 hours 10 hours
Note: Run times quoted are based on a new, fully charged battery.
Note:
SKC Limited reserve the right to make changes to the specification and design of this product at any time without prior notice to the end user.
www.skcltd.com 210-PMTXM Issue L Page 5
Specifications
Pump Features
Battery charging options
SKC offer two battery charger options for the Pocket Pump MTX series pumps, a single charger (Part No. 223-229A) and a five station charger (Part No. 223-107A). When the battery pack is fitted into the pump, a fast charge mode is enabled providing a charge time of up to 6 hours. If the battery is charged external to the pump then the charge time will be up to 16 hours.
Mains power option
The 223-229A single charger model can also be used as a mains adaptor to run the pump for indefinite periods whilst connected to the electrical mains supply. Note that it is recommended to ensure that the battery is fully charged prior to commencing sampling.
Warning - The pump must not be used in potentially explosive areas when the charger is connected.
Keypad cover
The pump controls are situated beneath a sliding cover to prevent accidental actuation of the keypad during a sample run.
LCD screen LCD screen indicates run-time data, operating and fault modes and battery charge state.
Constant flow mode Provides compensated constant flow control for single tube sampling applications.
Constant pressure mode Provides constant pressure control for multiple tube sampling applications.
Sample hold function Enables pausing and restarting of the pump during a sample.
Low battery shutdown
Automatic pump shutdown in the event of a low battery condition. The low battery shutoff voltage is selected to prevent over-discharge of the battery which can cause degradation of the battery performance. The pump retains the run-time data in the event of a low battery shutdown.
Page 6 210-PMTXM Issue L www.skcltd.com
Pump Features
Flow fault function
Indicates flow fault due to obstructed tubing or excessive filter loading. Shuts the pump down and enters ‘HOLD’ mode if the condition persists for longer than 15 seconds. Automatically attempts to restart every five minutes, until the flow fault condition clears in which case normal running will resume.
Particulate trap
Built in replaceable filter to trap particles that would otherwise contaminate the pump mechanism.
PC Connectivity
With optional DataTrac USB adapter cable and PC software. Enables programming of timed sample runs, delayed starts and intermittent sampling. Enables retrieval of pump run-time data and history to the PC.
Twin port model available
The 210-1003MTX twin port Pocket Pump includes an exhaust port enabling the pump to be used for sample bag filling and similar applications.
Specifications
www.skcltd.com 210-PMTXM Issue L Page 7
Blank Page
Page 8 210-PMTXM Issue L www.skcltd.com
1) Pump Models
210-1002MTX Standard ATEX approved pump with NiMH battery pack
210-1003MTX Twin port ATEX approved pump with NiMH battery pack
2) Care of Pocket Pump MTX Series Pumps
Always use the correct SKC battery pack and battery chargers designated for the Pocket Pump MTX series pumps.
Never run the pump long term without a tube or filter medium in place.
When carrying out sampling using long term colour change tubes always use a tandem tube holder with trap tube. This will prevent the aggressive fumes generated by these tubes from entering and damaging the pump mechanism.
The Pocket Pump MTX series pump cases are IP20 rated, they are not rated as water or splashproof and therefore must not be used where it is possible for water to enter the pump casing.
Pocket Pump MTX series pumps are fitted with a particulate filter which is easy to replace. For general maintenance replace the filter every 2-3 months or if it appears dirty. New filters are white in colour (order Part No. P40010).
If the sampling methodology to be used requires the collection of the sample from the outlet of the pump (210­1003MTX twin port model only), i.e. the sample is passing through the pump mechanism, ensure that the sample air is dry and does not contain corrosive constituents. Failure to do so could lead to contamination of the pump mechanism, degradation of performance or even failure of the pump.
Warning - Failure to follow these guidelines will void the product warranty.
General Information
www.skcltd.com 210-PMTXM Issue L Page 9
General Information
3) Non ATEX Certified Variants of the Pocket Pump
The Pocket Pump is also produced in a variant range which is UL certified for intrinsic safety and these pumps are therefore not suitable for use in potentially explosive atmospheres in Europe where ATEX approval is mandatory.
Pump components vary between the UL and ATEX certified variants, therefore components must not be interchanged between these pumps. If in any doubt please contact SKC Ltd customer services for advice.
4) Sampling Methods
This instruction manual provides the necessary information to set up and operate the Pocket Pump MTX series pumps. For more detailed information on specific sampling methods please refer to SKC’s Step-By-Step Guide to Air Sampling (Part No. 224-G1). To obtain a free copy please contact SKC Ltd customer services on +44 (0) 1258 480188 or download at www.skcltd.com.
5) The WEEE Directive
This product is marked with the crossed out wheelie bin symbol, which identifies that it falls within the scope of the EC Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). At the end of it’s useful life, this product must be disposed of in an environmentally sound way as detailed in the Directive. Note that the battery pack must be separated from the pump and disposed of as detailed in the Batteries Directive (see below). Please contact your local distributor or SKC Ltd for further details on how to comply with the requirements of the WEEE Directive. SKC Ltd’s producer registration number is WEE/KH0054TQ.
6) The Batteries Directive
The NiMH battery pack supplied with this pump and any spare battery packs purchased for it, fall within the scope of the EC Directive 2006/66/EC on batteries and accumulators and waste batteries and accumulators. At the end of the battery pack’s life it must be disposed of in an environmentally sound way as detailed in the Directive. Please contact your local distributor or SKC Ltd for further details on how to comply with the requirements of the Batteries Directive. SKC Ltd’s batteries producer registration number is BPRN00454.
Page 10 210-PMTXM Issue L www.skcltd.com
Air Inlet Port Air Inlet Port Air Exhaust Port
(210-1003MTX only)
Belt Clip
Slide Cover
(Open Position)
Keypad
LCD Screen
PC Interface
Connector
Inlet
Particulate
Filter*
*At base of inlet port
Battery Pack
Charging Jack
Socket
Diagram of the Pocket Pump
www.skcltd.com 210-PMTXM Issue L Page 11
Pocket Pump LCD Screen
Operating Indicators
Display Units
Numerals
Flow Fault Indicator
Battery Charge Status
Operating Indicators
PROG
Active when a program is loaded into the pump memory using the DataTrac interface and software
HOLD
Flashes when the pump is the HOLD state
ADJ
Flashes when adjusting the pump flow rate during flow calibration
FLOW
Active when the pump LCD screen displays the flow rate
VOL
Active when the pump LCD screen displays the volume of air sampled
SET
Flashes when setting the pump flow rate or back pressure setting
Display Units
°C or °F Sample air temperature in degrees Centigrade or Farenheit (Enhanced Display Mode only)
ins or mm Pump back pressure in inches of water or millimetres of mercury (Enhanced Display Mode only)
mL/min
Pump flow rate in millilitres per minute
mL or L Total volume of air sampled in millilitres or litres since last reset
min
Run time in minutes since last reset
Page 12 210-PMTXM Issue L www.skcltd.com
Getting Started
1) Charging the Battery Pack
The Pocket Pump MTX series pumps incorporate an intelligent charging function that monitors the battery pack during charging and automatically switches to a trickle charging rate when the battery pack is fully charged to prevent damage due to over-charging. A full charge will take up to 6 hours dependent on the charge state of the battery pack at the start of charging. The charging function also includes a feature that enables full charge rate only when the battery pack temperature is within the range +5 to +38°C. When the temperature is outside this range only trickle charging rate is enabled.
Pocket Pump battery packs can also be charged when not fitted to the pump. In this case charging occurs only at the trickle charging rate and a full charge will take up to 24 hours.
Use only the correct SKC chargers (Part Nos. 223-229A - single charger, 223-107A - five station charger). The chargers are supplied with mains input plugs suitable for use in the UK, Europe, USA and Australia / New Zealand.
Prior to first use the battery pack should be fully charged, ideally overnight. It will take 2 – 3 full charge / discharge cycles for the battery pack to achieve optimum capacity. If a new battery pack repeatedly exhibits a charging fault as detailed below it is recommended to condition the battery pack by running the pump until it shuts down due to low battery, then remove the battery pack from the pump and charge for 24 hours.
To charge the battery pack select the correct mains input plug and fit it to the charger. Plug the charger into the electrical mains supply and switch on the power. Plug the charger output jack plug into the mating socket at the base of the pump. The LED indicator on the charger will illuminate to indicate that the battery pack is connected.
During charging all three bars of the battery status icon on the pump LCD screen will flash. At the end of charging the battery status icon will be on (not flashing) and showing three bars to indicate full charge.
If the battery icon shows one flashing bar at the end of charging, this indicates a charging fault. It is recommended to disconnect the charger, wait for the battery pack temperature to stabilise to the ambient temperature then reconnect the charger. If the charging fault condition re-occurs this would indicate a fault with the pump, battery pack or charger. Contact SKC Limited customer services for further advice.
www.skcltd.com 210-PMTXM Issue L Page 13
Getting Started
When fully charged disconnect the charger jack plug from the battery pack.
2) Battery Status Indicator
The battery status indicator on the pump LCD screen shows the current battery charge level:
Fully charged. 3 bars displayed from approximately 100% to 75% capacity. Note: It is strongly recommended to ensure that the battery is fully charged before starting a sample run.
2 bars displayed from approximately 75% to 25% capacity.
1 bar displayed below approximately 25% capacity.
Low battery. No bars and flashing outline indicates low battery. Pump automatically switches to HOLD mode, and then SLEEP mode after 1 minute.
Battery charging. When the battery charger is connected, the battery status indicator flashes all 3 bars to indicate charging. At the end of charging the battery status indicator will stop flashing and show 3 bars continuously.
Battery charging error. Bottom 2 bars showing continuously and top bar flashing at the end of charging indicates a charging fault. Refer to text on page 10.
Page 14 210-PMTXM Issue L www.skcltd.com
Getting Started
3) Accessing the Pump Keypad
To access the pump keypad, slide the slide cover downwards until the buttons are exposed.
4) Operating the Three Button Keypad
The Pocket Pump operates by pressing various sequences of the three keypad buttons:
Star Button -
Scrolls through run time data on the LCD screen.
Sets up the pump operating parameters when used with other buttons.
Up and Down Arrow Buttons -
Increases or decreases either the flow rate (in constant flow mode) or the pump back pressure (in constant pressure mode) during setup.
Underlined Sequence -
All buttons in the sequence must be pressed consecutively within 10 seconds of the previous command.
Bracketed Sequence - [
]
All buttons within the brackets must be pressed simultaneously.
Security code -
The security code sequence is required to access the operating parameters, thus preventing unauthorised changes to the parameters and flow rate or back pressure settings.
5) SLEEP Mode
If the pump is left in HOLD mode for longer than five minutes the pump will automatically set itself to a low
www.skcltd.com 210-PMTXM Issue L Page 15
Getting Started
power SLEEP mode, with the LCD screen switched off. To wake the pump from SLEEP mode simply press any of the three buttons and the pump LCD screen will display the pump serial number followed by the internal software version number before switching to HOLD mode.
The pump will also automatically wake from SLEEP mode when the battery charger is connected.
6) HOLD and RUN Modes
To switch from HOLD mode to RUN mode press [ ]. The pump will start to run and the run-time data will be updated continuously in memory.
To switch from RUN mode to HOLD mode press [
]. The pump will stop and retain the run-time data in memory. The temperature and back pressure readings are still active in HOLD mode, and can be displayed on the LCD screen (in Enhanced Display mode).
7) Flow Fault
If pump operation is interrupted due to blocked or restricted flow, the flow fault indicator will flash. If the flow fault persists for 15 seconds the pump will stop and switch to HOLD mode, with the flow fault indicator on continuously. The pump will then wait 5 minutes before automatically switching to RUN mode to continue sampling. If the flow remains restricted the pump will return to HOLD mode, and attempt to restart every 5 minutes.
The accumated run time and and sample volume readings are not updated whilst the pump is in flow fault.
8) Resetting the Run-Time Data to Zero
To clear the run-time data including elapsed run time and accumulated sample volume, the following sequence is required:
With the pump running, press [
] to switch to HOLD mode, press , and then .
Loading...
+ 39 hidden pages