SJE Rhombus EZID1W114C3A4A6A10E24E30A User Manual

EZ Series® In-Site® CL Single Phase Duplex
The new EZ InSite Connect App allows you view real time pump run time, cycle counts, tank levels and more right from your smart device. All system data including pump run times, pump cycles, alarm conditions, power outages, and more can be downloaded using the EZ InSite Connect App, and analyzed using our exclusive InSite Reporting Software.
The EZ Series® In-Site® CL duplex control panel is designed to control two (alternating) 120, 208, 240 VAC single phase pumps in water and sewage installations. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail.
The panel conguration can easily be converted in the eld to either a timed dose or demand dose using a tablet or smartphone. All system data including pump run times, pump cycles, alarm conditions, power outages, and more can be downloaded using the exclusive EZ InSite® Connect App. Data reports make diagnosing system conditions easy.
The C-Level™ sensor is a pressure transducer that senses the liquid level in the tank and sends a signal to the EZ Series® In-Site® panel. C-Level™ CL40 sensor operating range is 3-39.9 inches (7.6-101.3 cm). C-Level™ CL100 operating range is 3-99.5 inches (7.6-252.7 cm).
The new compact redesign (10” x 8” x 4”) is ideal for residential applications. The innovative internal design of components and integral mounting tabs make installation quick and simple. Includes integral padlockable latch for added safety.
PANEL COMPONENTS
1. Enclosure base measures 10 X 8 X 4 inches (25.4 X 20.32 X 10.16 cm). NEMA 4X (ultraviolet stabilized thermoplastic with integral mounting tabs for outdoor or indoor use). Includes integral locking latch as standard.
2. Red LED Alarm Beacon provides visual check of alarm condition.
3. Circuit Breakers provide pump power disconnect and branch circuit protection.
4. Safety Cover with touch safe design.
5. C-Level™ Sensor/Float Connection Terminal Block
6. Incoming Control/Alarm Power & Pump Power Terminal Block
7. Control Power Indicator light illuminates if control power is present in panel.
8. Float Status Indicator lights illuminate when oat is active.
9. Pump Run Indicator lights illuminate when pumps are called to run.
10. Pump Manual Run Switches
11. Tank Level Indicator
12. Bluetooth® Wireless module
13. Ground lug(s)
14. Auxiliary Alarm Indicator
NOTE: Wiring Diagram and Pump Specication Label are located inside the panel.
3
10 9 11
Model Shown
EZID1W114C3A4A6A10E24E30A
Reg. Cdn Pat. & TM O
C-Level™ Sensor US Patent No. 8,336,385; 8,567,242; 8,650,949
2
FEATURES
Entire control system is UL Listed to meet and/or exceed industry safety standards
Dual safety certication for the United States and Canada
Bluetooth® Wireless connection for easy conguration and data downloading to a smart mobile device
Complete with step-by-step installation instructions
Five-year limited warranty
1
4
7
12
8
14
5
13
6
NOT SHOWN:
Exterior Alarm Test/Silence Switch allows horn and light to be tested and horn
to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared.
Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating).
SEE REVERSE SIDE FOR ORDERING INFORMATION.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth® SIG, Inc. and any use of such marks by SJE Rhombus® is under license. Other trademarks and trade names are those of their respective owners. Apple and the Apple Logo are registered trademarks of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC.
1-888-DIAL-SJE • 1-218-847-1317
1-218-847-4617 Fax
email: customer.service@sjeinc.com
B.7
EZI D 1 W 1 3A 4A 6A 10E 30A
MODEL EZI
MODEL TYPE
4
D = Duplex
ALARM PACKAGE
4
1 = alarm package (includes push to test/silence switch, red light & horn)
4
ENCLOSURE RATING
W = NEMA 4X
STARTING DEVICE
1 = 120/208/240 VAC
4
PUMP FULL LOAD AMPS
0 = 0-7 FLA 1 = 7-15 FLA
2 = 15-20 FLA
PUMP DISCONNECTS
4 = circuit breaker
4
SWITCH APPLICATIONS
4
C = C-Level™ sensor (must choose 24 or 29 option) Note: Pump down applications only.
Industry practices suggest that a secondary device, such as a oat switch, be used for redundant activation of the high level alarm and pump shut o.
4 C
OPTIONS Listed below
CODE DESCRIPTION
4
3A Alarm Flasher (included as standard) 3E High water alarm oat (must select 17 option)
4
4A Redundant o (included as standard) 4D Redundant o oat
(must select 4A option) (must select 17 option)
4
6A Auxiliary alarm contact, Form A (included as standard)
4
10E Lockable latch - NEMA 4X (included as standard) 17G SJE MilliAmpMaster™/ pipe clamp l (per oat) 17H SJE MilliAmpMaster™/ externally weighted l (per oat) 24E C-Level™ CL40 sensor w/ 4' vent tube and 20' cord 24F C-Level™ CL40 sensor w/ 4' vent tube and 40' cord 24G C-Level™ CL40 sensor w/ 8' vent tube and 20' cord
CODE DESCRIPTION
24H C-Level™ CL40 sensor w/ 8' vent tube and 40' cord 24P C-Level™ CL40 sensor w/ 4' vent tube and 100' cord 24R C-Level™ CL40 sensor w/ 8' vent tube and 100' cord 24X No C-Level™ CL40 sensor 29A C-Level™ CL100 sensor w/ 10' vent tube and 20' cord 29B C-Level™ CL100 sensor w/ 10' vent tube and 40' cord 29C C-Level™ CL100 sensor w/ 10' vent tube and 100' cord 29X No C-Level™ CL100 sensor
4
30A Bluetooth® Wireless Module
l Mechanically-activated Mercury-activated
B.8
© 2018 SJE, Inc. All Rights Reserved.
SJE RHOMBUS is a trademark of SJE, Inc.
9500050H-SPEC 05/20
Loading...