EZ Series® In-Site® CL Single Phase Duplex
The new EZ InSite Connect App allows you view real time pump run time, cycle
counts, tank levels and more right from your smart device. All system data
including pump run times, pump cycles, alarm conditions, power outages, and
more can be downloaded using the EZ InSite Connect App, and analyzed using
our exclusive InSite Reporting Software.
The EZ Series® In-Site® CL duplex control panel is designed to control two
(alternating) 120, 208, 240 VAC single phase pumps in water and sewage
installations. The alternating action equalizes pump wear. In addition to the
alternating pump control, this system provides override control should either
pump fail.
The panel conguration can easily be converted in the eld to either a timed
dose or demand dose using a tablet or smartphone. All system data including
pump run times, pump cycles, alarm conditions, power outages, and more can
be downloaded using the exclusive EZ InSite® Connect App. Data reports make
diagnosing system conditions easy.
The C-Level™ sensor is a pressure transducer that senses the liquid level in the
tank and sends a signal to the EZ Series® In-Site® panel. C-Level™ CL40 sensor
operating range is 3-39.9 inches (7.6-101.3 cm). C-Level™ CL100 operating range is
3-99.5 inches (7.6-252.7 cm).
The new compact redesign (10” x 8” x 4”) is ideal for residential applications.
The innovative internal design of components and integral mounting tabs make
installation quick and simple. Includes integral padlockable latch for added safety.
PANEL COMPONENTS
1. Enclosure base measures 10 X 8 X 4 inches (25.4 X 20.32 X 10.16 cm). NEMA
4X (ultraviolet stabilized thermoplastic with integral mounting tabs for outdoor
or indoor use). Includes integral locking latch as standard.
2. Red LED Alarm Beacon provides visual check of alarm condition.
3. Circuit Breakers provide pump power disconnect and branch circuit protection.
4. Safety Cover with touch safe design.
5. C-Level™ Sensor/Float Connection Terminal Block
6. Incoming Control/Alarm Power & Pump Power Terminal Block
7. Control Power Indicator light illuminates if control power is present in panel.
8. Float Status Indicator lights illuminate when oat is active.
9. Pump Run Indicator lights illuminate when pumps are called to run.
10. Pump Manual Run Switches
11. Tank Level Indicator
12. Bluetooth® Wireless module
13. Ground lug(s)
14. Auxiliary Alarm Indicator
NOTE: Wiring Diagram and Pump Specication Label are located inside the panel.
3
10 9 11
Model Shown
EZID1W114C3A4A6A10E24E30A
Reg. Cdn Pat. & TM O
C-Level™ Sensor US Patent No. 8,336,385; 8,567,242; 8,650,949
2
FEATURES
• Entire control system is UL Listed
to meet and/or exceed industry
safety standards
• Dual safety certication for the
United States and Canada
• Bluetooth® Wireless connection
for easy conguration and data
downloading to a smart mobile
device
• Complete with step-by-step
installation instructions
• Five-year limited warranty
1
4
7
12
8
14
5
13
6
NOT SHOWN:
Exterior Alarm Test/Silence Switch allows horn and light to be tested and horn
to be silenced in an alarm condition. Alarm automatically resets once alarm
condition is cleared.
Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating).
SEE REVERSE SIDE FOR ORDERING INFORMATION.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth® SIG, Inc. and any use of such marks
by SJE Rhombus® is under license. Other trademarks and trade names are those of their respective owners. Apple and
the Apple Logo are registered trademarks of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC.
1-888-DIAL-SJE • 1-218-847-1317
1-218-847-4617 Fax
email: customer.service@sjeinc.com
www.sjerhombus.com
B.7

EZI D 1 W 1 3A 4A 6A 10E 30A
MODEL EZI
MODEL TYPE
4
D = Duplex
ALARM PACKAGE
4
1 = alarm package (includes push to test/silence switch, red light & horn)
4
ENCLOSURE RATING
W = NEMA 4X
STARTING DEVICE
1 = 120/208/240 VAC
4
PUMP FULL LOAD AMPS
0 = 0-7 FLA
1 = 7-15 FLA
2 = 15-20 FLA
PUMP DISCONNECTS
4 = circuit breaker
4
SWITCH APPLICATIONS
4
C = C-Level™ sensor (must choose 24 or 29 option)
Note: Pump down applications only.
Industry practices suggest that a secondary device, such as a oat switch, be used for redundant
activation of the high level alarm and pump shut o.
4 C
OPTIONS Listed below
CODE DESCRIPTION
4
3A Alarm Flasher (included as standard)
3E High water alarm oat (must select 17 option)
4
4A Redundant o (included as standard)
4D Redundant o oat
(must select 4A option) (must select 17 option)
4
6A Auxiliary alarm contact, Form A (included as standard)
4
10E Lockable latch - NEMA 4X (included as standard)
17G SJE MilliAmpMaster™/ pipe clamp l (per oat)
17H SJE MilliAmpMaster™/ externally weighted l (per oat)
24E C-Level™ CL40 sensor w/ 4' vent tube and 20' cord
24F C-Level™ CL40 sensor w/ 4' vent tube and 40' cord
24G C-Level™ CL40 sensor w/ 8' vent tube and 20' cord
CODE DESCRIPTION
24H C-Level™ CL40 sensor w/ 8' vent tube and 40' cord
24P C-Level™ CL40 sensor w/ 4' vent tube and 100' cord
24R C-Level™ CL40 sensor w/ 8' vent tube and 100' cord
24X No C-Level™ CL40 sensor
29A C-Level™ CL100 sensor w/ 10' vent tube and 20' cord
29B C-Level™ CL100 sensor w/ 10' vent tube and 40' cord
29C C-Level™ CL100 sensor w/ 10' vent tube and 100' cord
29X No C-Level™ CL100 sensor
4
30A Bluetooth® Wireless Module
l Mechanically-activated Mercury-activated
B.8
© 2018 SJE, Inc. All Rights Reserved.
SJE RHOMBUS is a trademark of SJE, Inc.
9500050H-SPEC 05/20