Sirius SEM7, SEM8 User Manual

COMMERCIAL INFORMATION FOR THE CONSUMER
GB
INSTALLATION, USE AND MAINTENANCE INSTRUCTION
SEM1-SEM2-SEM5-SEM7-SEM8
TECHNICAL INFORMATION
TYPE:FSED
2
GB
3
GB
Warnings!
The air outlet of the appliance must not be connected to a ue which is used for exhausting other fumes from appliances, such as a central heating, boilers etc.. For the external exhausting of the fumes, comply with the regulations in force. Ventilate the room suitably according to the laws in force when the appliance is working to­gether with gas, oil or coal burning appliances, at the same time. The motor of the peripheral exhausting group is powered by the cooker-hood placed in the kitchen. Before connecting the cooker hood to the mains supply, make sure that the voltage indicated in the rating plate corresponds to the mains voltage in the home. Before carrying out any sort of maintenance or cleaning operation, make sure that the appliance is disconnected from the electrical mains. An appropriate maintenance ensures a good working and a good performance in the long run.
Usefulwarnings:
- Use an air outlet pipe with a maximum length not higher than 5 meters.
- Limit the number of bends in the exhausting pipe as every bend reduces the performance up to one linear meter. (If you use 2 90° bends, than the length of the pipe has not to be higher than 3 meters).
- The material for the pipe has to be approved by an authorized company.
- It is important to avoid changes in the diameter (we recommend a diameter of 150mm).
- Read carefully the manual of instructions and installation of the unit.
- Sirius will not be responsible for problems of capacity and/ or noise level due to the missed respect of the warnings included in the manual of instructions.
- SEM6/7 are equipped with a 200mm diameter hole for the exhausting pipe. If the unit that has to be connected to the remote fan is already equipped with a 200mm diameter hole, the nit is recommended to use a pipe with the same diameter in order to get good performances. Otherwise, if the unit is equipped with a 150mm diameter hole, than it is recommended to use the joint (from 200mm to 150mm), already supplied with the unit. The electric box cable should not be cut or joined together with other cables, since it could compromise the proper working and the safety conditions of the appliance. Furthermore, this will invalidate the manufacturer’s warranty coverage.
Warnings!
The SEM6 suction centrals can be connected to any other products from the same manufacturer if they are equipped with the External Motor version. In case they are connected to products from other suppliers. The manufacturer cannot be held responsible for damages caused by a dierent use. No gua­rantee or indemnity will be due.
4
SEM1(dis.1)-SEM8(dis.1a)
Warning!Theperipheralexhaustinggroup(remotettedextractionmotor)isbuiltinclass II(symbolontheratingplate),thereforeitmustnotbeearthed.
The appliance is designed to exhaust fumes and odours very silently and in the best way. It must be installed in the house and connected to the cooker-hood, which is in the kitchen (g.
2)
Typesofinstallation: to make the installation easy, the appliance can be xed on the wall, on the ceiling or on the oor in a horizontal position (g. 3 ) or vertically (g. 4) to the xing level.
Note:intheverticalxing,thebracketssuppliedcanbeusedonlyonthelongestside(g.6).
Installationoftheappliance: after deciding the position and the type of installation, insert the
anti-vibration rubber caps in the holes of the brackets supplied (g. 5C).
Therubbercapsmustbeputonthesideswhichareincontactwiththewall.
Put the brackets (g. 5A) on the remote tted extraction motor by matching its holes with those of the brackets. Fix with the screws supplied (g. 5B). Put the group on the point previously chosen for the installation and mark the points on the wall where the holes must be drilled. Insert the dowels supplied in the holes (g. 6A). Put the remote tted extraction motor on the wall by matching the holes of the brackets with the plastic dowels. Screw with the screws sup­plied (g. 6B).
Connectionofthepipes: the appliance is endowed with an entrance and an outlet to connect the pipes. Before connecting the exhaust pipes, check the direction of the air showed on the external label (g. 7). Connect the pipes and x them with appropriate metal clamps (exhaust pipes and metal clamps have to be supplied by the installer). The pipe (g. 7A) must be con­nected with the cooker-hood placed in the kitchen, and the pipe (g. 7B) must be directed outside the building.
Electricalconnection ofthe hoodSEM 1: the appliance is equipped with a 7m electrical ca­ble with a six- pin connection at one end. Insert it into the hood’s connection (External Motor version)
ElectricalconnectiontothehoodSEM8:the unit is supplied with a pipe 7 meters long. After having let the cable pass through the plastic pipe (g. 12E) placed in the wall (g. 12D), placed it closed to the unit and connect the 6 poles connector (g. 12E) and the 2 poles connector (g. 12G).
5
SEM2(g.9)
Warning!Theremotettedexhaustinggroup(externalmotor)isbuiltinclassIplate,the­reforeitneedstheearthconnection.
The appliance was designed to exhaust odours and vapours in the best way. The appliance is to be installed on the outside wall of the house and connetted to the cooker-hood which is in the kitchen (g. 10)
Installation: the mounting of the appliance is to be made by qualied technicians. Using the appropriate drilling jig (g. 11) drill all the holes marked on it into the external wall, by paying attention not to damage water pipes or power lines.
Theholesonthewallaretobedrilledwitha8mm.bit.Insert,stepbystep,thefollowing partsintheholesdrilled:
- the corresponding plastic dowels supplied (g. 11A)
- the two telescopic pipes in the hole of 160 mm.
- the plastic pipe of 40 mm. diameter. Before leaning the appliance against the wall, insert the supply cord in the plastic pipe. Fix the appliance without the stainless steel external body, which was previously removed from the motor block, by matching the holes of the motor block with the holes on the wall. Tighten with the screws supplied (g.11B).
Connectionofthepipes: the appliance is endowed with an air entrance to be connected with the telescopic pipes and an air outlet. After xing the appliance on the external wall, connect the two telescopic pipes, which are pla­ced inside the wall, with the cooker-hood through the exible pipes (g. 12). The xing between the pipes have to be made with appropriate metal clamps (pipes and clamps are supplied by the installer).
Electricalconnectiontothehood:
the unit is supplied with a pipe 7 meters long. After having let the cable pass through the plastic pipe (g. 12E) placed in the wall (g. 12D), placed it closed to the unit and connect the 6 poles connector (Fig. 12E) and the 2 poles connector (Fig. 12G).
In order to avoid water inltrations, please apply silicone on the product perimeter, close to the wall.
Installationofthestainlesssteelexternalbody: put the stainless steel body again, by ma­tching the air exhausting grid with the air outlet of the motor block (g. 13).
6
Loading...
+ 14 hidden pages