The symbol on the product or on its packaging indicates that this product may not be
treated as household waste. Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment. By ensuring this product
is disposed of correctly, you will help prevent potential negative consequences for the
environment and human health, which could otherwise be caused by inappropriate
waste handling of this product. For more detailed information about recycling of this
product, please contact your local city oce, your household waste disposal service or
the shop where you purchased the product. This appliance is marked according to the
European directive 2002/96/EC on waste electrical and electronic equipment (WEEE).
3
GB
Warnings!
The air outlet of the appliance must not be connected to a ue which is used for exhausting
other fumes from appliances, such as a central heating, boilers etc..
For the external exhausting of the fumes, comply with the regulations in force.
Ventilate the room suitably according to the laws in force when the appliance is working together with gas, oil or coal burning appliances, at the same time.
The motor of the peripheral exhausting group is powered by the cooker-hood placed in the
kitchen.
Before connecting the cooker hood to the mains supply, make sure that the voltage indicated in
the rating plate corresponds to the mains voltage in the home.
Before carrying out any sort of maintenance or cleaning operation, make sure that the appliance
is disconnected from the electrical mains.
An appropriate maintenance ensures a good working and a good performance in the long run.
Usefulwarnings:
- Use an air outlet pipe with a maximum length not higher than 5 meters.
- Limit the number of bends in the exhausting pipe as every bend reduces the performance up
to one linear meter. (If you use 2 90° bends, than the length of the pipe has not to be higher
than 3 meters).
- The material for the pipe has to be approved by an authorized company.
- It is important to avoid changes in the diameter (we recommend a diameter of 150mm).
- Read carefully the manual of instructions and installation of the unit.
- Sirius will not be responsible for problems of capacity and/ or noise level due to the missed
respect of the warnings included in the manual of instructions.
- SEM6/7 are equipped with a 200mm diameter hole for the exhausting pipe. If the unit that
has to be connected to the remote fan is already equipped with a 200mm diameter hole, the
nit is recommended to use a pipe with the same diameter in order to get good performances.
Otherwise, if the unit is equipped with a 150mm diameter hole, than it is recommended to use
the joint (from 200mm to 150mm), already supplied with the unit.
The electric box cable should not be cut or joined together with other cables, since it could
compromise the proper working and the safety conditions of the appliance. Furthermore, this
will invalidate the manufacturer’s warranty coverage.
Warnings!
The SEM6 suction centrals can be connected to any other products from the same manufacturer
if they are equipped with the External Motor version. In case they are connected to products
from other suppliers.
The manufacturer cannot be held responsible for damages caused by a dierent use. No guarantee or indemnity will be due.
The appliance is designed to exhaust fumes and odours very silently and in the best way. It
must be installed in the house and connected to the cooker-hood, which is in the kitchen (g.
2)
Typesofinstallation: to make the installation easy, the appliance can be xed on the wall,
on the ceiling or on the oor in a horizontal position (g. 3 ) or vertically (g. 4) to the xing
level.
Put the brackets (g. 5A) on the remote tted extraction motor by matching its holes with those
of the brackets. Fix with the screws supplied (g. 5B).
Put the group on the point previously chosen for the installation and mark the points on the wall
where the holes must be drilled.
Insert the dowels supplied in the holes (g. 6A). Put the remote tted extraction motor on the
wall by matching the holes of the brackets with the plastic dowels. Screw with the screws supplied (g. 6B).
Connectionofthepipes: the appliance is endowed with an entrance and an outlet to connect
the pipes. Before connecting the exhaust pipes, check the direction of the air showed on the
external label (g. 7). Connect the pipes and x them with appropriate metal clamps (exhaust
pipes and metal clamps have to be supplied by the installer). The pipe (g. 7A) must be connected with the cooker-hood placed in the kitchen, and the pipe (g. 7B) must be directed
outside the building.
Electricalconnection ofthe hoodSEM 1: the appliance is equipped with a 7m electrical cable with a six- pin connection at one end. Insert it into the hood’s connection (External Motor
version)
ElectricalconnectiontothehoodSEM8:the unit is supplied with a pipe 7 meters long. After
having let the cable pass through the plastic pipe (g. 12E) placed in the wall (g. 12D), placed
it closed to the unit and connect the 6 poles connector (g. 12E) and the 2 poles connector (g.
12G).
The appliance was designed to exhaust odours and vapours in the best way. The appliance is
to be installed on the outside wall of the house and connetted to the cooker-hood which is in
the kitchen (g. 10)
Installation: the mounting of the appliance is to be made by qualied technicians. Using the
appropriate drilling jig (g. 11) drill all the holes marked on it into the external wall, by paying
attention not to damage water pipes or power lines.
- the corresponding plastic dowels supplied (g. 11A)
- the two telescopic pipes in the hole of 160 mm.
- the plastic pipe of 40 mm. diameter.
Before leaning the appliance against the wall, insert the supply cord in the plastic pipe. Fix the
appliance without the stainless steel external body, which was previously removed from the
motor block, by matching the holes of the motor block with the holes on the wall. Tighten with
the screws supplied (g.11B).
Connectionofthepipes: the appliance is endowed with an air entrance to be connected with
the telescopic pipes and an air outlet.
After xing the appliance on the external wall, connect the two telescopic pipes, which are placed inside the wall, with the cooker-hood through the exible pipes (g. 12).
The xing between the pipes have to be made with appropriate metal clamps (pipes and clamps
are supplied by the installer).
Electricalconnectiontothehood:
the unit is supplied with a pipe 7 meters long. After having let the cable pass through the plastic
pipe (g. 12E) placed in the wall (g. 12D), placed it closed to the unit and connect the 6 poles
connector (Fig. 12E) and the 2 poles connector (Fig. 12G).
In order to avoid water inltrations, please apply silicone on the product perimeter, close to
the wall.
Installationofthestainlesssteelexternalbody: put the stainless steel body again, by matching the air exhausting grid with the air outlet of the motor block (g. 13).
This model has been specically studied to suction vapours and odours without noise.It should
be installed outside and connected to the hood in the kitchen (g. 22).
Roofinstallation: make a 22 x 22 cm square opening on the roof, and then insert the lower part
of the remote tted exhausting motor (g. 23).
Put the two brackets as shown in g 24A and mark the holes you are going to drill on the lower
part of the remote tted exhausting motor.
Make all the holes, and then fasten securely.
Insert the pipe connecting the hood outlet line with the upper part of the remote tted extraction motor (g.25A); the pipe should pass into the lower part of the remote tted exhausting
motor (g. 25).
Fix the pipe to the upper part of the remote tted exhausting motor with a metal hose clamp.
Assembly the upper and the lower part of the remote tted exhausting motor using the 8 screws
provided (g.25B).
Electricalconnectionofthehood: the appliance is equipped with a 7m electrical cable. Connect it to the six-pin connection of the appliance in the kitchen.
7
SEM7(dis.27)
Warning!
The remote tted exhausting group (external motor) is built in class I plate, therefore it needs
the earth connection.
The appliance was designed to exhaust odors and vapors in the best way. The appliance is to
be installed on the outside wall of the house and connected to the cooker-hood which is in the
kitchen (g. 28)
Installation:
the mounting of the appliance is to be made by qualied technicians. Using the appropriate
drilling jig (g. 29) drill all the holes marked on it into the external wall, by paying attention not
to damage water pipes or power lines. The holes on the wall are to be drilled with a 8 mm. bit.
- the corresponding plastic dowels supplied (g. 29)
- the two telescopic pipes in the hole of 200 mm.
- the plastic pipe of 40 mm. diameter.
Before leaning the appliance against the wall, please remove the stainless steel carter using the
8 perimetrical screws (g. 30), then insert the supply cord in the plastic pipe. Fix the appliance
without the stainless steel external body, which was previously removed from the motor block,
by matching the holes of the motor block with the holes on the wall. Tighten with the screws
supplied.
Connectionofthepipes:
the appliance is endowed with an air entrance to be connected with the telescopic pipes and an
air outlet. After xing the appliance on the external wall, connect the two telescopic pipes (g.
12C), which are placed inside the wall, with the cooker-hood through the exible pipes.
The xing operations have to be carried out by using suitable metallic tools (pipes and tools
have to be supplied by the installers).
Electricalconnectiontothehood:
the unit is supplied with a pipe 7 meters long. After having let the cable pass through the plastic
pipe (g. 12E) placed in the wall (g. 12D), placed it closed to the unit and connect the 6 poles
connector (Fig. 12E) and the 2 poles connector (Fig. 12G).
In order to avoid water inltrations, please apply silicone on the product perimeter, close to
the wall.
Installationoftheexternalcarter:
mount the aesthetic carter making sure that the grill will match with the block motor air outlet
(dis. 30).
8
WIRING DIAGRAM SEM1 - SEM5
9
WIRING DIAGRAM SEM2
10
WIRING DIAGRAM SEM7
11
WIRING DIAGRAM SEM8
12
SEM1
1
2
1a
3
4
5
13
6
7
8
14
OK
910
OK
OK
SEM2
OK
9
11
13
10
12
14
15
SEM5
OK
22
OK
22
22
OK
22
24
OK
22
24
21
23
25
22
24
26
16
SEM7
27
29
28
30
17
18
19
9004200486 - GM 04/12
Loading...