Use negative ion function. Press “Ionizer” button to switch on/off the function.
Press “speed/ Mode” button to adjust the speed of fan.
IonizerSpeed/ Mode
Sleep
Turbo
Auto
What to do when you are away?
Use kid lock function. You don’t need to worry about safety risk caused by
mis-operation when they left alone
kid’s
Child Lock
Speed/ ModeReset
Sleep
Turbo
Auto
How to use in office and public place?
Use AUTO function. Air purifier will automatically work based on the actual indoor air
quality level. Press SPEED button, you can set at
SLEEP or TURBO mode.
Speed/ Mode
AUTO, SPEED 1, SPEED 2, SPEED 3,
Sleep
Turbo
Auto
Timer
When power on, press TIMER, it will switch off after 1, 2, 4, 8 hours later.
Timer
Air quality indicator:
Air quality levelLED color
CriticalRed
WarningBlue
GoodGreen
How to use when sleep?
Press SPEED button, select SLEEP function. Air purifier will work under mute, without
light. Press SPEED again, exit from SLEEP
Speed/ Mode
Sleep
Turbo
Auto
Page 3
Safety instructions
Introduction
Thank you for choosing EuropAce product! For a better understanding of product
usage and functions, safety precautions and product maintaining, please read
and follow the user manual carefully, especially content with symbols.
Content with this symbol must be followed
for safety reasons in order to avoid damage
to product and harm to humans.
Please don’t spray any painting, pesticide, alcohol and any chemical on the unit.
Otherwise it will cause crack on unit, risk of shock and fire hazard
If any chemic
be harmful to your healthy. After used pesticide in the room, please don’t use the unit
before change of air in the room.
Don’t use the unit in flammable and corrosive environment.
When the unit is working, please don’t touch air inlet and outlet. Don’t insert your
hands or other objects into the air inlet and outlet to prevent from hurt or damage the unit.
To prevent from any accident and harm, don’t sit on the
Please don’t use the unit in bathroon or wet places. It may cause fire hazard and
risk of shock.
Don’t improperly modify, disassembly, repair the unit. It ay cause fire hazard and
risk of shock.
Please don’t use if the cable and plug is broken. Don’t touch with wet hand. It may
cause fire hazard and risk of shock
Switch it off and unplug it when move the unit, undergo maintenance
Unplug the unit when not use for long time
Stop using the product if you found odor in the unit, contact after-sales service.
Before use, please check if there are objects drop inside the unit
Place the unit 50mm away from the the wall or obstacle.
If the cable is damaged, to prevent any risks, only service staff and professionals
are allowed to replace it.
al placed inside of the unit, it will release to air from air outlet. It may
Content with this symbol must be followed
for product safe usage in order to avoid
malfunctioning and harm to humans.
place any object on the u
nit
Purification system
This product has multi-stage filtration system. It can be effectively remove haze, dust,
dander, hair, pollen, smoke and other floating particles, it also removes formaldehyde,
benzene, ammonia, VOCs, nocotine and other odors. It effectively elimilate germs,
virus.
Hepa filter can elimilate multi pollutants, such as haze, smut, smoke, pollen.
silver coated on HEPA filter can quickly kill bacteria, virus, mold, mites.
Active carbon filter use high-effective coconut shell activated carbon, effectly remove
formaldehyde, benzene, ammonia, vocs and other odors.
Negative ionizer will release ions to refresh the indoor air.
Nano
Page 4
Product features
Operation Guide
Advanced feature; able to adjust according to surrounding temperature,
and regulates air to an ideal environment for people.
When power is on, the air purifier starts to count the life of filters - it will continue
to count with every power on from where it was left off. After reaching 2000 hours,
the Reset LED will flash to indicate that a replacement is needed.
Press “Reset” button for 3 seconds, after ‘beep’ sound, LED will off.
After filter is replaced - Press “Reset” button for 5 seconds, after 3 ‘beep’ sound,
LED will off and time counter will restart on the new filter.
Negative Ion
When power is on, press “Ionizer” button, the ionizing function will start, LED will on.
Press button again to switch off.
Timer
When power is on, press “Timer” button to enable purifier to switch off at
designated time. Timer range activate in an order: [ OFF ]
Operation guide
Kid-lock function
When power is on, press “Reset” + “Speed/Mode” buttons at the same time for 3 seconds
to activate lock function. LED at power button will flash every 0.5 seconds, at this time
any other buttons will not work.
Press “Reset” + “Speed/Mode” buttons at the same time again for 3 seconds to remove
lock function. LED will return to normal and buttons will work.
Speed setting
When power is on, press “Speed/Mode” button to set a speed from 6 selection.
Speed range activate in an order: [ 1 2 3 Sleep Turbo Auto ]
Speed/Mode
Speed/Mode
Sleep
Turbo
Auto
Sleep
Turbo
Auto
Speed/Mode
Speed/Mode
Sleep
Turbo
Auto
Sleep
Turbo
Auto
Speed/Mode
Speed/Mode
Sleep
Turbo
Auto
Sleep
Turbo
Auto
Page 6
Maintenance Guide
Maintenance Guide
This product is not recommended to placed on uneven surface to avoid vibration,
noise during working and prevent risk of shock.
To prevent damage, do not put any objects inside the unit.
When not in use for an extended period, unplug it and keep away from children.
To achieve better purification results, place product in an open area, refrain from
blocking air inlet and outlet of unit.
Please switch off the unit and unplug when undergoing maintenance, checks
and moving the unit.
HEPA filter and active carbon filter need to be replaced after been expired.
Please purchase from an authorised dealer.
Maintaining notes
To extend the life of unit, please regularly undergo maintenance. Before maintenance,
please switch off the unit and unplug it. After use, if the filters need to be replaced, the
filter change indicator on the control panel flashes. It reminds of user to replace with a
new filter. HEPA filter and active carbon filter need to be replaced at the same time.
Removal of PE bag
Before first time use, please open the front panel, take out the filters and remove its
PE bag wrap - or the unit will not be able to purify the air.
Clean / replace filters
Please follow the pictures on the filter below to correctly install the filter:
As shown in diagram A below: hold both upper sides of the unit, pull out the
front panel and lift it.
Note: The black sponge used in front of the HEPA filter can be washed with
water and can be re-used after dry. It is recommended to wash it every 3
months to extend the life of HEPA filter.
As shown in dragram B: pull down the strap on the filter to take out HEPA filter.
As shown in dragram C: pull down the strap on the filter to take out carbon filter.
Please hold the middle part of the front panel with both hands to install it as
shown in diagram D.
Reminder: HEPA and carbon filters cannot be washed with water.
1
Cleaning instructions
External clean
Before clean the external of the unit, please cut off the power.
- Use soft and clean cloth.
- Do not use alcohol, gasoline, benzol and other chemical cleaner.
2
Page 7
Troubleshooting & SolutionCaution
MalfunctionCheck pointSolution
Failure to
power on
Unit operating
sound very
low and weak
air output
Air outlet has
an odor
Check if switch is on
Check if plug is loose
Check if front panel is
correctly installed
Check if PE bag was
removed
Check if air outlet is
blocked
Check if there are objects
with odor placed near
unit’s air inlet
Check if the filters need
to be replaced
Switch unit on
Correctly plug it to power source
Correctly install panel to unit
Remove the PE bag and install the
filters in correct order
Switch off unit and remove any
obstruction
Remove those odor-causing objects
Replace filters for the unit
Use voltage only at 230V 50Hz. Otherwise it may cause
fire hazard and risk of shock.
Do not improperly bend, pull, twist, tie the power cable or
place it near the high temperature. Damage of the cable
may cause fire and risk of shock.
Do not use put any heavy object on it or clip it.
If the cable or plug is broken and remains loose when
plugged into the socket, please do not use it.
Do not touch the plug with wet hands.
Please do not replace or change the cable. If broken,
please contact service hotline.
Please clean away any dust or dirt on the plug and cable
ATTENTION
regularly.
Page 8
Specifications
Contacts
Product
Power input
Rated power input
Optimal room size
CADR
Temperature/Humidity applied
Dimensions
Weight netto/bruto
Air purifier SINCLAIR
-
45A
SPModel
V~
-
240
20
2
80
W
do 45 m2
340 m3
-
40 °C / 20
0
×
374
8,5
/ 8,6
50 Hz/
dB55Max Noise level
(A)
/h / 205 CFM
-
90 %
×
201
594
kg
mm
PRODUCER
SINCLAIR CORPORATION Ltd.
4 Argyll St.
1
LONDON
W1F 7LD
United Kingdom
-
www.sinclair
The device was made in China (Made in China).
PRESENTATIVE
ER
SINCLAIR Global Group s.r.o.
Purkyňova 45
Brno
612 00
world.com
, SERVI
CE
Czech republic
Phone
Phone
-
-
: +420 541 590 140sales
: +420 541 590 150 ceservi
Fax: +420 541 590 124
www.sinclair
info@sinclair
solutions.com
-
ns.comsolutio
15
Page 9
16
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.