Read this manual ca
or operating your new air conditioning
unit. Make sure to save this manual for
futu
re r
efe
ence.
r
OTE:
r
efully befo
r
e installing
Page 3
To Users
Thank you for
carefully before installing and using the product, so as to master and correctly use
the product. In order to guide you to correctly install and use our product and
achieve expected operating effect, we hereby instruct as below:
(1) This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsibility for their safety. Children should
be supervised to ensure that they do not play with the appliance.
(2) This instruction manual is a universal manual, some functions are only
applicable to particular product. All the illustrations and information in the
instruction manual are only for reference, and control interface should be
subject to actual operation.
(3) In order to make the product better, we will continuously conduct improvement
and innovation. We have the right to make necessary revision to the product
from time to time due to the reason of sales or production, and reserve the right
to revise the contents without further notice.
(4) For personal injury or property loss and damage caused by improper operation
such as improper installation and debugging, unnecessary maintenance,
violation of related national laws and rules and industrial standard, and violation
of this instruction manual, etc., we will bear no liability.
(5) The final right to interpret for this instruction manual belongs to SINCLAIR
CORPORATION
selecting Sinclair’s
Ltd.
product. Please read this instruction manual
Page 4
Contents
1 Safety Notices (Please be sure to abide) ................................. .. .. .. .. .........1
Warning: If not abide strictly, it may cause severe damage to the
unit or the people.
Note: If not abide strictly, it may cause slight or medium damage to
the unit or the people.
This sign indicates that the operation must be prohibited. Improper
operation may cause severe damage or death to people.
This sign indicates that the items must be observed. Improper
operation may cause damage to people or property.
WARNING!
This product can’t be installed at corrosive, inflammable or explosive
environment or the place with special requirements, such as kitchen. Otherwise, it
will affect the normal operation or shorten the service life of the unit, or even cause
fire hazard or serious injury. As for above special places, please adopt special
product with anti-corrosive or anti-explosion function.
2 Product Composition
The kit includes the following assembly, please check before installation.
Modbus Gateway
1 set
Specification
1 set
1
Page 6
Gateway Kit
3 Function statement
When the user needs to conduct central control/remote monitor, connect the
product to the indoor unit of communication network. The gateway plays the role of
connecting the main board of indoor unit and central controller/remote monitor.
4 Product Installation
4.1 Installation location
According to the installation requirements, the box of the gateway shall be used
screws for fixing, or double sided adhesive tape shall be pasted on the unit, wall
and ceiling near the electrical box.
4.2 Network topological graph
L1 network in the fig can be connected to 255 gateways at most.
Figure 4-1 Network topological graph
2
Page 7
Gateway Kit
4.3 Wiring specification
(1) Communication cord L2 from the gateway shall be connected to the 6-core
needle holder.
(2) Open the upper cover of gateway, you can see 4 screws wiring terminals with
the mark of A, A, B and B separately.
Figure 4-2 Mark diagram of wiring terminal
3
Page 8
Gateway Kit
(3) Choose either of AB wiring terminal, connect it to the central controller/remote
monitor; if there are multiple gateways, the other AB wiring terminal shall be
connected to the next gateway.
Figure 4-3 Diagram of wiring terminal
4.4 Wire selection
Model selection of communication cord for gateway, central controller/remote
controller:
4
Page 9
Gateway Kit
Code of
communication
cord
L1
L2
Wire type
Ⅴ twisted-pair
(2-core)
--
Series
model
AWG24
Remark
When the communication
distance exceeds 800m, a
photoelectric isolation
repeater shall be added
6-core communication cord
standard configuration
5 Instruction for use
5.1 Indicator instruction
When the indicator is flashing normally, it means the gateway is operating
normally.
No.IndicatorFunction introduction
1
2
Power indicator (red)Always on after power on
Communication indicator (green)Blinking when operating
5
Page 10
Page 11
Page 12
NOTE CONCERNING PROTECTION OF
ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be
taken to a collection station for the recycling of electrical and electronic devices. The symbol on the
product, the operating instructions or the packaging indicate such disposal procedures. The materials
are recyclable in accordance with their respective symbols. By means of re-use, material recycling or
any other form of recycling old appliances you are making an important contribution to the protection
of our environment. Please ask your local council where your nearest disposal station is located.
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112
PRODUCER
SINCLAIR CORPORATION Ltd.
1-4 Argyll St.
London W1F 7LD
Great Britain
www.sinclair-world.com
This product was manufactured in China (Made in China).
REPRESENTATIVE
SINCLAIR Global Group s.r.o.
Purkynova 45
612 00 Brno
Czech Republic
TECHNICAL SUPPORT
SINCLAIR Global Group s.r.o.
Purkynova 45
612 00 Brno
Czech Republic