Sinclair CFO-12E, CFO-20E User Manual

Page 1
CFO-12E CFO-20E
DEHUMIDIFIER
USER’S
MANUAL
Page 2
Before using your dehumidifier,
please read this user’s manual carefully, in order to ensure cor­rect and safe use. After reading the manual, make sure it is stored in a safe place for future refer­ence if necessary.
Contents
Structure and principle
Operation
Maintenance
Appen-
dix
1
2
3
4
6
7
9
12
12
13
14
18
Features
Specifications
How dehumidifying works?
Structure of dehumidifier
Operation steps
Operation panel
Draining the water
Caring for the dehumidifier
Storing the dehumidifier
Notation for safe operation
Removing breakdowns
Electric Schematic Diagram
Page 3
- 1 -
Structure and Principle
Features
Quiet operation
When the dehumidifier operates in QUIET mode, the value of its noise is so low and makes your room quiet.
Powerful dehumidifying capability
Taking advantage of refrigeration principle, the de­humidifier powerfully removes partial moisture from air to drop the humidity of the room and keep indoor air dry and comfortable.
Excellent drying laundry function
The dehumidifier dries laundry quickly. This can prevent laundry and furniture from becoming damp and musty in a rainy season.
Drainage tank with a large capacity
The drainage tank capacity is large to 6 liter, this will reduce the times of your discarding water.
Using refrigerant for protecting environment
The dehumidifier uses the no CFC refrigerant for protecting environment to reduce to pollute environment.
Saving energy
The power consumption is low.
Page 4
- 2 -
Specifications
The dehumidification capacity is the value obtained after the dehumidifier was continuously run in the
room temperature of 30
with the relative humidity 80%.
The amount of dehumidification is the amount per day(24 hours.) If specifications are changed without notice for further improvement, they are data on nameplate of the unit. The work temperature is in the range 2 to 38 . If the room temperature is beyond the range, the unit can not operate normally.
Structure and Principle
Power Supply
Dehumidifying Capacity
Power Consumption
Drainage Tank Capacity
Weight
Dimension(height
width depth)
Model CFO-12E CFO-20E
220 230V, 50Hz
6.0L(automatic stop at about 5.5L)
12L/day 20L/day
220W 400W
12.5kg 14kg
545mm
380mm 261.5mm
working temperqture range of maximum charge dehumidifying:35 C DB/26 C WB.
Page 5
- 3 -
Structure and Principle
How dehumidifying works
It draws in room air, cools it with a cooling unit, and changes the humidity to drops of water.
The drops of water fall into a drainage tank. The dehumidified air is re-heated by a heating
unit and discharged.
Steps
, ,and are repeated to remove humid-
ity from the room.
After the air passes through the re-heating unit, its temperature will rise a little, so that the tempera­ture of the room will rise appreciably. This is normal phenomenon.
Cooling unit
Re-heating unit
Moist air
Dried air
Compressor
Drainage tank
Page 6
- 4 -
Structure of dehumidifier
Handle
Discharge port
Float
Louver
Operation panel
Water level gauge
Structure and Principle
Drainage tank
Plastic film
NOTE: Please take off the plastic film before using.
Page 7
- 5 -
Structure and Principle
Continuous drain­age port
Air filter (Air intake port, do not obstruct!)
Power supply plug
Page 8
- 8 -
Operation
Operation steps:
1. Plug the power supply plug into the outlet.
2. Open the louver by hand.
3. Press the power suitch.
4. Select operation mode or let it run in the default mode.
5. Press the power switch once again to stop operation.
- 6 -
Page 9
- 6 -
Operation
Operation panel
Indicator lamp
1.Tank full indicator lamp It will light when the drainage tank is full or positioned incorrectly. Empty the water out of the drainage tank, and make sure the tank is positioned properly.
2.Power indicator lamp It will light when the unit is plugged in.
3.mode indicator lamp When “ ” lamp or
” lamp or ” lamp is lighted, it respectively indicates that operation is in DEHUMI-
DIFY, LAUNDRY or QUIET mode.
4.Humidity indicator lamp When “50%” lamp, “60%” lamp or “70%” lamp is lighted, it respectively indicates that the current setting humidity is “50%”, “60%” or “70%”. “CON”: Continuously dehumidity indicator lamp When “CON” lamp is lighted, it indicates that the operation is in CONTINUOUS mode.
- 7 -
Page 10
- 7 -
Operation
Switch function
5. “ ” switch Press the switch once to start operation, press it again to stop operation.
6. “ ” switch Each time the switch is pressed, the operation mode changes in the order of “DEHUMIDIFY”, “LAUN­DRY” and “QUIET” and the corresponding mode indicator lamp will change with the operation mode. The default is “DEHUMIDIFY”. when the indoor temperature is above 35
, the protection device is
actuated, the unit only can operate in LAUNDRY mode and pressing “ ” switch is ineffective.
7. “ ” switch Press the switch to set the humidity of the room, which can be set in order of “50%”, “60%” “70%” and “continuous”, the defanlt is “continuous”. When the relative humidity of the room is lower than your setting humidity, the operation will stop automatically.
- 8 -
Page 11
- 9 -
Operation
Draining the water
If the drainage tank becomes full (approx. 5.5 liters), the “ ” lamp lights to alert the user, operation stops automatically. Empty the water from the drainage tank and discard it.
1. Remove the drainage tank Lightly pressing on the sides of the tank with both hands, pull it gently out.
Do not remove the bubble packing from the float on the unit, in order to prevent water from leaking from the water tank onto household furniture. This can cause electrical shock and/or short-circuiting.
If the drainage tank is dirty, wash it with cold or lukewarm water. Do not use detergent, scouring pads, chemically treated dustcloths, gasoline, benzene, thinner, or other solvents to clean it, as these can scratch and damage the tank and cause water to leak.
T ake hold of the handle, and then remove the tank, discard the water.
Drainage steps Notation for drainage
When place back the drainage tank, press the tank
firmly into place with both hands. If the tank is not positioned properly, the Ò Tank FullÓ sensor will be activated, and the dehumidifier will not operate. Check to make sure the guards are firmly attached to the tank. If they are not, the drainage tank will be harder to remove.
Wait at least 30 minutes before removing the drain­age tank, in order to prevent the water which still in the cooling unit from dripping out on the base plane. (If water has dripped, wipe it up.)
Page 12
- 10 -
The unit has a continuous drainage port. Using a commercial hose (with an inner diameter of 15mm), the water in the drainage tank can be continuously drained out of the continuous port of the unit. When setting up the equipment for continuous drainage, always stop operation first and unplug the power supply plug.
Operation
Draining the water
Continuous drainage of water
2. Push the hose into the continuous drainage port
Pass a commercial hose (with an inner diameter of 15mm) through the continuous drainage port, and press it firmly into the drainage port in the main unit, make sure water does not leak. The level height of drain piping should al­ways be not higher than the one of the drainage port, also drain piping should always be not plugged up, so the con­densed water can be drained out successfully.
3.Return the drainage tank to its original position
Check the hose periodically to make sure it is still connected and has not been obstructed.
1. Disconnect the drainage tank and open the con­tinuous drainage port.
Use nippers or a similar tool to cut away the continuous drainage port in the side of the main unit.
Page 13
- 11 -
Please stop working and discard the water before move the dehumidifier. T ilt it within range of 30 degrees.
Note:
Make sure at lease some place is provided around it when the unit is operating.
Operation
Page 14
- 12 -
Storing the dehumidifier
When the unit is not to be used for a long period of time
4. Store the unit Package the unit to keep it free of dust, and keep it upstanding and store it at a cool and dry place.
1. Fold up the power supply cord and secure it to the holder.
2. Discard any water left in the drainage tank and wipe away any remaining drops with a cloth.
3. Clean the air filter.
Clean the air filter
The air filter should be cleaned approximately once two week. First, Remove the air filter, then run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the air filter is very
dirty, wash it with warm water and a neutral cleaning solvent and dry it thoroughly, attach the airfilter.
Caring for the dehumidifier
Maintenance
Page 15
- 13 -
Maintenance
Notation for safe operation
When use the unit, please observe the following safety precautions:
1.When the unit works in LAUNDRY mode, keep it an appropriate distance away from the clothings, and prevent the water from dropping onto it.
2.Before clean the unit or when do not use it for along period of time, unplug the power supply cord.
3.Do not wash the unit with water also put the unit close to water,explosive or flammable things.
4.Do not set the unit close to heat-generating devices or near inflammable and dangerous article.
5.Never put your fingers or objects into the intake or discharge ports.
6.Do not sit or stand on the unit.
7.Discard water that has collected in the tank timely.
8.Do not run the dehumidifier in an closed area such as inside closets, or fire can take place.
9.
Do not use the unit for special purposes such as edible items, objects of art or scientific materials are stored.
10.
Install drain piping in a downhill grade to make sure that condensed water can be drained continuously.
11.
If the supply cord is damaged, it must be replaced by the manufacture or its service agent or a similarly qualified person in order to avoid a hazard.
Page 16
- 14 -
The unit does not operate.
Has the power supply cord been disconnected?
Is the “ ” lamp blinking?(The tank is full or in a wrong position.)
Plug the power supply cord into the outlet.
Discard the water in the drainage tank, and then reposition the tank.
The protection device is actuated and the unit can not be started in case operation is under the bad environment (in that case,please do not use the dehumidifier).
Is the temperature of the room above 38
or below 2 .
If a condition listed below occurs, please check the following items to help you to save your time and cost.
Condition Cause What to do
Maintenance
Removing breakdowns
Page 17
- 15 -
Maintenance
The dehumidifying function does not work.
No air is discharged.
Is the air filter clogged?
Is air intake port or discharge port obstructed?
Clean the air filter as instructed un­der “Caring for the dehumidifier”.
Remove whatever is obstructing the discharge port or intake port.
Is the air filter clogged?
Clean the air filter as instructed un­der “Caring for the dehumidifier”.
Use the unit in a stable, sturdy location. Prompt: Put a cushion under the unit and help to reduce operation noise.
Operation is noisy.
Has the unit been poorly installed so it is tilted or unsteady?
Is the air filter clogged?
Clean the air filter as instructed un­der “Caring for the dehumidifier”.
After the above condition has occurred and corresponding step is used but the breakdown can not be removed or other breakdown occurs, please contact the authorized service centers.
Page 18
- 16 -
The operation noise suddenly increases during use.
The operation noise increases when the compressor is activated.
The humidity do not drop.
Is the room too big for the unit? Are windows or doors opened and closed frequently? Is there a device in the room such as a kerosene stove, which emits steam?
Very little dehumidifying takes place, or none takes place.
This happens if the temperature and/or humidity of the room is low.
When the unit is first used, the dis­charged air smells musty.
Because the temperature of the head exchanger rises abruptly, an unusual or musty odor may be produced for a moment.
The following symptoms do not indicate a breakdown
Symptom Reason
Maintenance
Removing breakdowns
Page 19
- 17 -
Maintenance
The unit echoes.
If the unit is used in a room with wood flooring or in a small room, it may echo.
When operation is started or the opera­tion mode is changed, an unusual noise is heard in main unit.
The refrigerant may take some sound until circulation stabilizes.
There are some stains left in the drain­age tank.
The unit only can run in laundry mode and it is ineffective to press mode switch.
This is water left from the dehumidifying test conducted at the factory, it does not indicate a problem.
The fan is running and the compressor does not work.
If the unit is started within 3 minutes after the unit stops, the protection device is actuated, so that the compressor is started automatically after a delay of 3 minutes; or the automatic defrosting operation is activated and the compressor stops.
When the temperature of the room is above 35 the protec­tion device is actuated , so that the unit only can run in LAUN­DRY mode( the fan speed is high).
Page 20
- 18 -
APPENDIX
Electric Schematic Diagram
Loading...