1.Safety Cautions 1
2.Configuration 2
3.Assemble and disassemble 4
4.Operating instrutions 10
5.Maintenance 13
7.Troubleshooting 15
8.Loading List 16
THROUGH-WALL AIR CONDITIONER
Model
AW-12AAW 12A-
Page 2
1 2
Safety cautions
Configuration
SAFETY WARNING BODY CONFIGURATION
Component configurationComponent configurationComponent configuration
1.Control Panel
2.Display Window
3. Indoor Outlet
4. Adjustable Foot pad
5. Indoor Inlet
6. Outdoor Outlet
7. Outdor Inlet
8. Drain
9. Handle
1.Drainpipe external joint
2.Drainpipe
3.Drainpipe internal joint
4.Screw
5.Cushion
6.Drainpipe Connecting rod
7.Drainpipe external joint hook
8.RemotE controller
PRECAUTIONS
Do not use this product near open flameInflammable and explosives.
To avoid the possibility of any damage ,do not beatCrush or shake this machine.
Do not cover or block the inlet and outlet in case of any potential hazard caused by over-heating of this machine
To avoid the possibility of electrical Shock, make sure this machines is not easily exposed to water
Make sure the professional Electric Personnel or service agent IS sended for maintenance When the power cord is damaged.
Do not alter the length of the power cord or share the socket with other eleCtric appliances.
To avoid the possibility of electrical shock, do not unplug with wet hands.
Do not insert sticks or other objects.
Do not use altered power cord plug. Do not allow Children playing around.
Please place this machine 1m away from the TV and radio to avoid the possibility of
electromagnetic interference.
Do not place This machine in the sun to avoid the fading of the surface.
Make sure the angle of inclination is less than 35°While transportation , 5°While operating
This macHine can not be used in certain rooms(more detailed information in the technical
parameters)
Do not use chemical solvent to clean the surface to avoid the possibility of any SCRATCH,
DAMAGE and deformation.
Make sure the condenser water IS fully discharged during Removal or inclination to avoid any leakage.
1 2
3
4
5
6
7
9
8
7
6
5
4
1
2
3
8
Page 3
3
4
Assemble And Disassemble
DISPLAY SCREEN SYMBOL SPECIFICATION DISPLAY SCREEN SYMBOL SPECIFICATIONDISPLAY SCREEN SYMBOL SPECIFICATION ■ ASSEMBLE
OPERATION BUTTON SPECIFICATION
DISPLAY SCREEN
111098
7654321
1.AUTO
1.Put the machine in Place, ADJUST the nut to keep the machine horizontal; Any inclination
will cause Inadequate passage of water in the machine.
2. Drill a hole in walls in accordance with the position of the DRAINPIPE (As illustrated in
the picture)
2.COOLING
5.FAN SPEED
3.DEHUMIDIFICATION
11.WIND DIRECTION
1.TEMPERATURE/WIND SPEED DOWN
2.TEMPERATURE/WIND SPEED UP
3.TIMING
4.SLEEP
5. AUTOMATIC SWING
6. WINDSPEED
7. MODE
8. ON/OFF
9. CONTROLLER ACCEPTANCE WINDOW
10.SLEEP
7.HEAT
6.FAN SPEED
8.SETTLE THE HOUR
9.TIMER
4.TEMPERATURE
1 2 3 4 5 6 7 8 9
Configuration
Nut4
TEMP/DOWNTEMP/DOWNTEMP/DOWN TEMP/UPTEMP/UPTEMP/UP
TIMETIMETIME
SLEEP SLEEP SLEEP
WIND WIND WIND
SPEED SPEED SPEED
MODE MODE MODE
ON/OFFON/OFFON/OFF
Page 4
5 6
Assemble And Disassemble Assemble And Disassemble Assemble And Disassemble Assemble And Disassemble
3.Place the drainpipeL=482mmIn waist-shape hole,beyong the external wall 5mm;
NOTE: The length of the drainpipe can be incised in accordance with the thickness of the wall (Ex. the thickness of the wall W=300mm, 482+23-300-5=200mm can be incised)
4.Wrench the drainpipe external joint hook into the drainpipe external joint
5.Stretch beyong the wall through the macropore in the drainpipe
6 .Pull the drainpipe external joint in walls to make it coordinate with the drainpipe;
7 .Stretch the drainpipe Connecting rod to a certain length beyond the wall Through the rail
alongside the drainpipe, then RotaTe 90°And pull inwards horizontally till the limit;
8 .Accomadate the drainpipe internal joint into the drainpipe through drainpipe connecting rod.
In walls
beyond walls
23mm
5mm
Page 5
7 8
Assemble And Disassemble Assemble And Disassemble Assemble And Disassemble Assemble And Disassemble
9.Cushion into the connecting rod for air exhaust duct, and fix screw.
10.Disconnect the excessive drainpipe connecting rod;
The following procedure can be applied when the machine is to be fixed on the wall (at the request of the customers)
1.Push hard the tab to the back of the machine, rotate the air-inlet grille and remove it;
2.Remove the filter, release the screw, and remove the air-inlet frame;
Push
Filter
Screw
Air-inlet
11.Another drainpipe connecting rod follows 7-10
12.Push the machine into the hole on the wall (the heihgt of the screw can be adjusted to
facilitate the process).
Page 6
9 10
Assemble And Disassemble Assemble And Disassemble Operating Instructions Operating Instructions
3.Push upward the front shroud and then forward, then remove it;
4.Sew on the screw st5x8 and fix it;
OPERATION BUTTION SPECIFICATION: (the buzzer will make a “D”sound when pressing The button and the operation is effective.)
1.When the electricity is on ,the machine Will make two “D D”Short Sound, press the button ,
the machine is on; press again , the machine is Off; turn on the machine after the machine halts, 3 minutes automatic protection will be on.
2.For setting the operation mode, in accordance with the following order:
4.TEMP/UP AND TEMP/DOW Nto set temperature and timing
1Set the temperature, once pressing the button TEMP/UP TEMP/DOWN, the temperature climbs or falls 1; when the indoor temperature is displayed on LED, when first pressing the button, it will switch to the display of setting temperature, after that, every time when pressing the button, the temperature climbs or falls 1;5 seconds after the operation, LED will re-display the indoor temperature; 2When in the time setting position, every time when pressing TIME/UP TIME/DOWN, the time gains or looses 1 hour, the time being 0-12 hour circulating setting,5 seconds
after the time setting, it will fall into timer position; if the current setting is 0 hour,5seconds after the time setting ,it will quit the timing position.
5. TIMER: (1To set the machine on, pressing the button can set timing shutdown, pressing the TEMP/UP TEMP/DOWN can set timing shutdown;re-pressing the button when the timing is not determined will cancel timing shutdown; during timing shutdown, the customer can shutdown the machine manually to cancel the timing shutdown;2 To set the machine off, pressing the button can set the timing start, pressing the TEMP/UP TEMP/DOWN can set the on time; press the button again when the timing is not determined can cancel the timing shutdown, the customer can shutdown the machine manually to cancel the timing shutdown;
6.SWING
Press the button will switch between automatic swing and swing halt, the swing angle being 120°;The swing wind is simultaneous with the internal wind machine switch.
7.SLEEP
(Sleep can only work when the cooling and heating mode is on, sleep will automatically cancels when restart) when the sleep is on, the internal wind machine will automatically switch to low wind.
A.When the cooling is on: after 1hour,the set temperature climbs 1;2 hour later, it climbs another 1;6 hours later, off;
b.When the heating is on; after 1hour,the set temperature falls 1;2 hour later, it falls another 1;6 hours later, off;
5. Assemb le the disassemb led parts following the compleme ntary procedures.
Disassemb le
1.If the machine is fixed on the wall, disassemble the air-inlet frame and front cover, then
wrench the screw;
2.Remo ve the ma chine;
3.Loose the screw, and remo ve the fixed connecting rod cover and drainpipe internal joint
4.Loose the drainpipe connecting rod and rotate 90°,remove alon the rail alongside the drainpipe;
5.Remo ve the drainpipe from the drainpipe;
6.Remo ve the drainpipe.
AIr-inlet
Scre
low speed wind
edium speed wind
igh speed wind
auto
cooling
ehumidification
entilation eating
3.3.
d v
h
h
m
Page 7
11 12
Remote controller operation How to assemble batteries and set the time
1.Auto
2.Cooling
3.Dehumidification
4.Ventilation
5.Temperature
6.Highspeedwind
7.Mediumspeed wind
8.Lowspeed wind
9.Auto swing on
10.Auto swing off
11.Time
12.Sleep on
13.Timer on
14.Timer off 15Timing.
1.open back cover
2.place the batteries into the slot, pay attention to the two poles.
3.press the button as illustrated in the picture
4.set the time flash
5.adjust the hour button 6press the button as illustrated in the picture again when the time is set, the setting is completed when the time display symbol stops flashing.
.
Notes:
1The positive pole and negative
pole of the battery must correspond with the respective pole on the controller. 2Do not mix the new batteries with the old ones. 3Please remove the batteries when the controller is not to be used for a while. 4To avoid environmental pollution, make sure the batteries are removed before deserted, and arrange them properly.
How to operate with the controller
There are two methods to use the controller to operate the autocoolingheating dehumidificationventilation mode:
1. Select the operation mode>> adjust the setting temperature>> adjust the wind speed >>. off (this method is same with the operating instructions of the operating panel)
16.Mode 17Temp/ up
18.Temp/ down
19.Wind speed
20.Swing
21.Time hour
22.Time minute
23.Sleep on/off
24.Timing
25.On/off
LCD display screen
Operating instructionsOperating instructions
Operating instructions Operating instructions
1
2
3
4
5
6
Page 8
13 14
Technical parametersTechnical parameters
1Remove the air-inlet grille; remove the filter from back of the machine; 2Soak the filter in 40°C or so mild water contain netural detergent to clean, dry it in the shades; 3After dried put the filter back to the back of the machine and close theair-inlet grille.
Notes:
1.To avoid the possibility of any electrical shock, make sure the machines is shutdown and the socket is unplugged before cleaning;
2.If the air output decreases due to the pile-up of dust in the filter, it is suggested the filter cleaned every other month.
Drainage
When the machine is on the cooling position, the condenser water will bedischarged into the chassis, auto-alarm will be on when the chassis is filled with water, the buzzer beeps for 20 seconds, LED display screen will display E4; meanwhile the cooling system is off. The indoor inner wind machine will shut after 3minutes, please unplug the rubber plug alongside the machine for drainage if more cooling is needed.
continuous-drainage
Please select this method when the machine will be use for a while;
1. Unplug the rubber plug alongside the machine as illustrated in the picture. Place it carefully for further usage.
2.Connect the drainpipe to the drain as illustrated in the picture. The condenser water will be discharged from the drainpipe.
4. PVC pipe with inner pathway of 8mm can be connected to the drainpipe. If the drainpipe
3. Take the drain pipe connect with drainage.
is to be lengthened. Notes; the drainpipe shall be parallel with or lower than the drain.
FILTER CLEANING
Model
Rfrigerating capacity (Btu/h)/W
12000/3500
Heating capacity(Btu/h)/W
12000/3500
Dehumidification capacity (L/h) 1.8
Heating input power (W) 1500
Refrigerating input power (W) 1300
Circulating input air (m³/h) 400
power(single-phase) (V~/ Hz) 230V/50Hz
Noise dB (A)
52
Net weight (kg) 47
body (mm) 610×285×825
Body package (mm) 685x370x885
Dimensions
Accessories package
(mm)
420X230X525
Refrigerant Charge R410A / 790g
Applicable area(m²) 20~25
Notes: since the high updating speed of the products, revision of Technical parameters will
not be otherwise notified.
AW- 12 A
MaintenanceMaintenance
Device is not intended for continuous running.
Page 9
15 16
Loading listTroubleshootingTroubleshooting
Before maintenance request, please check the machine with the following methods:
the machine can not start
The machines stops automatically
No cool air when cooling position is on
No hot air when heating position is on
LED E1
LED E2
LED E3
LED E4
LED E5
Power troubles:
1. the power cord is not plugged
2.the power cord or socket is damaged
3.The fuse is cut off
Timing off time is up or the indoor temperature is lower than the set temperature
1. Iindoor temperature is lower than the set temperature 2 The indoor temperature is too low and causes anti-frozen protecti on
.
1. Tthe indoor temperature is higher than the set temperature 2Defrosting.
lack of coolant
indoor temperature sensor out of order or damaged
indoor coil sensor out of order or damaged
chassis filled with water
outdoor coil sensor out of order or damaged
re-start after adding coolant
change indoor temperature sensor
change indoor coil sensor
Discharge the chassis
change outdoor coil sensor
1. This is normal, it will start automatically when the indoor temperature is higher than the set temperature
2. The machine will start automatically after defrosting.
This is normal, the machine will start automatically when after defrost or indoor temperature is lower than the set temperature.
Close timing shutdown or wait until machine starts
1.Plug the power cord
2. Change the power cord or socket
3. (Specification3.15A/250V).ask the local after-service agent to change the fuse
TROUBLES CAUSES SETTLEMENT
No.1
BODY PACKAGE COMPONENGS NAME
QUANTITY
1.1 Mobile air conditioner 1
1.2 Controller 1
1.3 Specifications 1
1.4 Drainpipe(1.5m) 1
No.2
ACCESSORIES PACKAGE COMPONENGS NAME
2.1 Drainpipe internal joint 1
2.2 Drainpipe external joint 1
2.3 Drainpipe 1
2.4 Drainpipe connecting rod 2
2.5 Drainpipe external joint hook 1
2.6 M3 screw cushion 2
2.7 Universal wheel 4
2.8 Spanner 1