Sinclair ASV-35AS WIFI, ASV-25AS, ASV-25AS WIFI, ASV-35AS User Manual

Page 1
USER'S MANUAL
EN
CAMPER TRAILER
ASV-25AS (WIFI), ASV-35AS (WIFI)
Page 2
CONTENTS
A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT .......................................1
ELECTRICAL DATA ..............................................................................................................1
ELECTRIC DIAGRAM ...........................................................................................................2
PACKING LIST ......................................................................................................................3
PARTS NAME........................................................................................................................4
CONTROL PANEL ..............................................................................................................12
INSTALLATION INSTRUCTION..........................................................................................13
STEP 1-SELECTING AN INSTALLATION LOCATION & INSTALLING THE ROOF TOP AIR CONDITIONER ......13
STEP 2-MOUNTING OUTDOOR UNIT..........................................................................................16
STEP 3-INSTALLING THE CEILING ASSEMBLY .............................................................................17
STEP 4-ELECTRICAL WIRING
STEP 5-COMPLETING THE INSTALLATION
TROUBLESHOOTING GUIDE ............................................................................................21
NOTE CONCERNING PROTECTION OF ENVIRONMENT................................................24
INFORMATION CONCERNING USED REFRIGERANT MEDIUM.....................................24
PRODUCER ........................................................................................................................24
REPRESENTATIVE, TECHNICAL SUPPORT....................................................................24
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabiliti
..................................................................................................18
.................................................................................20
es
,
or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user mainte
To be in compliance with IEC/EN 61000-3-11, impedance value of power-supply
nance shall
not be made by children without supervision.
system connected to product must be less than or equal to the allowable maximum value of Zsys in the following sheet:
models
ASV-25AS ASV-35AS
max Zsys unit:ohms
0.316Ω
Page 3
INSTALLATION PRECAUTION
WARNING:
Observe all governing codes and ordinances.
Do not use damaged or non-standard power cord. Be caution during installation and maintenance. Prohibit incorrect operation
to prevent electric shock, casualty and other accidents.
Otherwise, the cool air can’t be blown out and there will be condensate water on the horizontal louver.
Working temperature range
Suggested working temperature range: +4 ~ 46 Outdoor unit may stop operation.
due to various kinds of protection within working temperature range.
. (heating:+4~24 /cooling:+18~46 )℃ .
Selection of Installation Location
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable, please consult the local dealer:
1. The place with strong heat sources, vapors, flammable or explosive gas, or volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment). The place near coast area.
3.
4.
The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. This air conditioner unit is only used for the vehicle without concave and convex surface on the top of it.
8. Prohibit operating this air conditioner unit when starting up the vehicle or when the vehicle is driving.
9. Prohibit supplying the power for the air conditioner unit with the vehicle power supply.
Requirement of air conditioner
1. Air inlet should be far away from obstacles and do not put any objects near air outlet. Otherwise, it will affect the radiation of heat-removal pipe.
2. Select a location where the noise and outflow air emitted by the outdoor unit will not affect neighborood.
3.Please try your best to keep far away from fluorescent lamp.
4.The appliance shall not be installed in the laundry.
Page 4
INSTALLATION PRECAUTION
Requirements Forelectric Connection
Safety precaution
1.
Must follow the electric safety regulations when installing the unit.
For appliances with type Y attachment,the instructions shall contain the
3. substance of the following.If the supply cord is damaged,it must be replaced by
avoid a hazard.
Properly connect the live wire, neutral wire and grounding wire of power socket.
4. Be sure to cut off the power supply before proceeding any work related t o electricity and safety.
5.
with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
8. The yellow-green wire or green wire in air conditioner is grounding wire, which
can't be used for other purposes.
9.
The grounding resistance should comply with national electric safety regulations.
10. The appliance shall be installed in accordance with national wiring regulations
Page 5
A FEW WORDS ABOUT YOUR NEW
AIR CONDITIONING UNIT
Thank you for choosing the Recreational Vehicle Air Conditioner.
This manual will supply you with all the information for installation, operation and maintenance.
Take a few minutes to discover how to get the most in cooling comfort and economic operation
from your new air conditioner.
Please keep this manual well for future reference.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.
ELECTRICAL
1.
All wiring must be complied with local and national electrical codes. All wiring must be installed by qualified electricians. If you have following instructions, contact a qualified
2.
Check the available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3.
This air conditioner is designed to operate from a 220-240V AC, 50Hz, 1 Phase power supply.
4.
The wiring diagrams are located on the cover of the control box. The assembly unit wire diagrams are located on the ceiling panel.
5.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
electrician.
DATA
any questions about the
6.
The Electric schematic diagram are subject to change without notice. Please refer to which one on the unit.
- 1 -
Page 6
Ceiling Assembly
ELECTRIC DIAGRAM
AP1
DISPLAY
BOARD
CN1
CONNECTOR
AP2
Roof Top Air Conditioner
DISP2
DISP1
DISPLAY
MODULE
ROOM
SENSOR
AP3
WIFI
MODULE
RT1
OUTDOOR UNIT
CONNECTOR
INDOOR UNIT
L N
POWER
PE
BN BU
YEGN
YEGN
PE
ELECTRIC BOX
PE
TUBE SENSOR
CN4
WIFI_CON DISP1 DISP2
N1
BU
BU
OUTDOOR
RT1
(20K)
(WH)
AC-L1
CAP.
S
R
COMP.
TUBE
CN5
RT3
(15K)
OUTROOM
SENSOR
VT VT
4WAY N
SENSOR
RT2
(20K)
(BK)
AP1 MAIN BOARD
WH
COMP
K1
COMP
RD
C
YEGN
PE
OUT_FAN
M2
YEGN
PE
4-WAY VALVE
4YV
OUT_FAN
MOTOR
YEGN
PE
IN_FAN
OUT_FAN1
M3
YEGN
PE
IN_FAN
MOTOR
M1
OUT_FAN
MOTOR
- 2 -
Page 7
PACKING LIST
Packing List of Indoor Unit
owner’s manual
Packing List of Outdoor Unit
LED
TIMER ON
clasp(10)
Double-sided gummed paper
Foam (up) Foam (accessory)
Bolt sub-assy
M8X135 (4)
battery (2)
(AAA 1.5V)
remote controller
Remote controller holder
Sponge (foam accessory)
Tapping screw (8)
Sunk screw (2)
(remote controller holder)
Mounting plate sub-assy
Insulating sheath Bolt sub-assy(4)
M6X25
Tapping screw(4) ST4.2X25 MA
- 3 -
Sponge and Bundle (2)
Page 8
PARTS NAME
Indoor Unit
Filter sub-assy Air-in grille
LED indicator
Control panel (membrane)
(Display content or position may be different from above graphics, please refer to actual products)
Air-outgrille
TIMER ON
remote controller
LED
LIGHT
Outdoor Unit
Outer case
Air-in grille
Drainage outlet
Chassis
NOTICE:
Actual product may be different from above graphics, please refer to actual products.
- 4 -
Page 9
OPERATION OF WIRELESS REMOTE CONTROLLER
Buttons on remote controller
Note: This remote controller is the universal remote controller. Some function is not
available for this unit.
1
ON/OFF button
MODE button
2
- button
3
+ button
4
5
FAN button
1
3
5
7
9
12
13
ON/OFF MODE
_
FAN
CLOCK
TIMER ON
TURBO
TEMP
SLEEP
+
LED
TIMER OFF
LIGHT
2
4
6
8
10
11
14
10
11
12
13
14
Introduction for icons on display screen
Operation mode
Auto mode Cool mode
Dry mode
Fan mode
Heat mode
Clock
Sleep mode
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
6
7
8
9
button
CLOCK button
LED button
TIMER ON button
TEMP button
TIMER OFF button
TURBO button
SLEEP button
LIGHT button
Set fan speed
Send signal Set temperature
This is a general remote controller. Some models have this function while some do not. Please refer to the actual models.
Turbo mode Set time
TIMER ON / TIMER OFF
Child lock Light
Up & down swing
- 5 -
Page 10
Introduction for buttons on remote controller
Note:
● This is a general use remote controlle , it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
" "
● After putting through pow r, air conditioner will give out a sound and operation indicator
(red indicator). You can operate the air conditioner through the remote controller.
is ON
At ON status, after each pressing button on remote controller, the signal icon " "
flash once.Air conditioner will give out a sound,which
● Under ff status, set temperature and clock icon will be displayed on the display of remote controller (If timer on, timer off and light functions are set, the corre-sponding icons will be displayed on the display of remote controller at the same
ON/OFF button
1
time); Under on status, the display will show the corresponding set function icons.
indicates the signal has been sent to air conditioner.
on remote controller will
Press this button, the unit will be turned on, press it once more, the unit will be turned off. When turning on or turning off the unit, the Timer, Sleep function will be canceled, but the presetting time is still remained.
MODE button
2
Press this button, Auto, Cool, Dry, Fan, Heat mode can be selected circularly. Auto mode is default while power on. Under Auto mode, the temperature will not be displayed; Under Heat mode, the initial value is 28℃(82℉); Under other modes, the initial value is 25
(77℉).
AUTO COOL DRY FAN HEAT
(Only for cooling and heating unit. As for cooling only unit, it won’t have any action when it receives the signal of heating operation.)
- button
3
Presetting temperature can be decreased. Press this button, the temperature can be set up, continuously press this button and hold for two seconds, the relative contents can quickly
℃(℉
change, until unhold this button and send the order that the
) signal will be displayed all the time. The temperature adjustment is unavailable under the Auto mode, but the order can be sent by if pressing this button.
+ button
4
For presetting temperature increasing. Press this button, can set up the temperature, when unit is on. Continuously press and hold this button for more than 2 seconds, the corresponding contents will be changed rapidly, until unpress the button then send the information,
℃(℉
) is displlaying all along. In Auto mode, the temperature can not be set up, but operate this button can send the signal. Centigrade setting range: 16-30; Fahrenheit scale setting range 61-86.
- 6 -
Page 11
FAN button
5
Press this button, Auto, Low, Middle, High speed can be circularly selected. After powered on, Auto fan is not available for this mode. When pressing AUTO button, the fan speed will not change.
AUTO
Middle fanLow fan
Note: Under the Dry mode, the fan speed isn't adjustable, low fan speed is imperative,
but when operating this button, the wireless adjustable, low fan speed is imperative.
6
Press this button turn on swing function; 4s later, press this button to turn off the swing and it will operate like that circularly. Other air conditioners, press this button, to set up swing angle, which circularly changes as below:
This is an universal use remote controller. If remote controller sends the following three kinds of status that the swing status of main unit will be:
When the guide louver start to swing up and down, if turn off the Swing, the air guide louver will stop at current position.
button
OFF
High fan
which indicates the guide louver swings up and down between that all five positions.
CLOCK button
7
Press this button, the clock can be set up, signal blink and display. Within 5 seconds, the value can be adjusted by pressing + or - button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten place of Minute will be increased
. During blinking, repress the Clock button, signal will be constantly displayed and1.
denotes the setting succeeded. After powered on,12:00 is defaulted to display and signal
will be displayed. If there is signal be displayed that denotes the current time value
is Clock value, otherwise is Timer value.
LED button
8
Press this button can turn on or turn off the LED light on the panel.
TIMER ON button
9
Timer On setting: Signal “ON” will blink and display, signal will conceal, the numerical section will become the timer on setting status. During 5 seconds blink, by pressing + or
- button to adjust the time value of numerical section, every press of that button, the value will be increased or decreased 1 minute. Hold pressing + or - button, 2 seconds later, it
- 7 -
Page 12
quickly change, the way of change is: During the initial 2.5 seconds, ten numbers change
in the one place of minute, then the one place is constant, ten numbers change in the tens place of minute at 2.5 seconds speed and carry. During 5s blink, press the Timer button, the timer setting succeeds. The Timer On has been set up, repress the timer On button, the Timer On will be canceled. Before setting the Timer, please adjust the Clock to the current actual time.
10
Press this button, could select displaying the indoor setting temperature or indoor ambient temperature. When the indoor unit firstly power on it will display the setting temperature, if the temperature's displaying status is changed from other status to " ", displays the ambient temperature, 5s later or within 5s, it receives other remote control signal that will return to display the setting temperature. if the users haven't set up the temperature displaying status, that will display the setting temperature. (This function is applicable to partial of models)
After powered on, the setting temperature displaying is defaulted, (according to cust­omers requirements to display, if there is no requirement that will default to display the presetting temperature and there is no icon displayed on wireless remote control). Press this button, (When displaying ), will display presetting temperature; (when displaying ) will display indoor ambient temperature, current displaying status will not be changed. If current displays indoor ambient temperature, if received the other remote control signal, it will display presetting temperature, 5s later, will back to display the ambient temperature.
TEMP button
(This function is applicable to partial of models)
11
Once press this key to enter into TIMER OFF setup, in which case the TIMER OFF icon will blink. The method of setting is the same as for TIMER ON.
12
In Cool or Heat mode, press this button can turn on or turn off the Turbo function. After turned on the Turbo function, its signal will be displayed. When switching the mode or changing fan speed, this function will be canceled automatically.
13
Press this button, Sleep On and Sleep Off can be selected. After powered on, Sleep Off is defaulted. After the unit is turned off, the Sleep function is canceled. After Sleep function set up, the signal of Sleep will display.In this mode, the time of timer can be
TIMER OFF button
TURBO button
SLEEP button
adjusted. Under Fan and Auto modes, this function is not available.
- 8 -
Page 13
14
LIGHT button
Press this button to select LIGHT on or off in the displayer. When the LIGHT on is set, the icon will be displayed and the indicator light in the displayer will be on. When the LIGHT off is set, the icon will be displayed and the indicator light in the displayer will be off.
Introduction for special function
About AUTO RUN
When AUTO RUN mode is selected, the setting temperature will not be displayed on the LCD, the unit will be in accordance with the room temp. automatically to select the suitable running method and to make ambient comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so that the ambient temp. approachs the preset temp. as soon as possible.
About Blow over heat (This function is applicable to partial of models)
When the unit is running in Heat mode or Auto Heat mode, compressor and indoor fan is running, to turn the unit off, the compressor, outdoor fan will stop running. The upper and lower guide board rotate to horizontal position, then the indoor fan will run at low fan speed, 10s later, the unit will turn off.
WIFI Function
Press "MODE" and "TURBO" button simultaneously to turn on or turn off WIFI function. When WIFI function is turned on, the " " icon will be displayed on
remote controller; Long press "MODE" and "TURBO" buttons simultaneously for 10s, remote controller will send WIFI reset code and then the WIFI function will be turned on. WIFI function is defaulted ON after energization of the remote controller.
(This function only applicable for some models. )
Wi-Fi Application:
Google Play EWPE Smart
- 9 -
Page 14
Operation guide
General operation
1.
. After powered on, press ON/OFF button, the unit wi
start to run. (Note: when it is powered on, the guide louver of main unit will close automatically.)
2.. Press MODE button, select desired running mod
3.
. Pressing + or - button,to set the desired temperatur
(It isunnecessary to set the temp. at AUTO mode.)
4.
. Pressing FAN button, set fan speed, can sele
LOW, MID and HIGH.
5.. Pressing button, to select the swin
Optional operation
1.. Press SLEEP button, to set slee
. Press TIMER ON and TIMER OFF button, can
2.
set the scheduled timer on or timer off.
3.
. Press LIGHT button, to control the on and off of t
displaying part of the unit (This function may be not available for some units).
4.
. Press TURBO button, can realize the ON and O
LED
TIMER ON
LIGHT
LED
TIMER ON
LIGHT
of TURBO function.
5.. Press LED button,can turn on or turn off the light the panel.
- 10 -
Page 15
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
reinstall
battery
remove
make sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
Cover of battery box
NOTICE
● During operation, point the remote control signal sender at the receiving window on indoor unit.
● The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles between them.
or wireless telephone; remote controller should be close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the batteries.
● If the display on remote controller is fuzzy or there’s no display, please replace batteries.
- 11 -
Page 16
CONTROL PANEL
Note: If the remote controller is missing, operate on the control panel.
6
ON/OFF indicator
5 4
1
ON/OFF button
Operation starts when pressing this button, and stops when pressing this button again.
temp. indicator
3
COOL indicator
receiver window
2 1
5
MODE button
Select the operation mode, COOL,FAN,
HEAT.
HEAT indicator
2
LIGHT button
Press this button to turn on or turn off display light on indoor unit.
3
(+/-) button
Press the + button to increase the set(operating) temperature of the unit,and press the - button to decrease the set(operating) temperature of the unit. the temperature setting range is from 16~30
(61~86 F).
4
FAN SPEED button
Select the fan speed LOW, MED, HIGH and TURBO in sequence.
o
6
FILTER CHECK indicator
This feature is a reminder of cleaning the air filter(normal maintenance) for more efficient operation. The light will turn on automatically after the fan works more than 250 hours. If the light is on, turn off and power off the unit, take the air filter out and clean it, then re-install the air filter, power on and turn on the unit, the light will still be on, press + button for 5s,the light will turn off.
- 12-
Page 17
INSTALLA TION INSTRUCTION
BEFORE INSTALLATION
T
estrun the unit with proper power supply. Refer to the operation instruction section in the Owner’s Manual Operation & Installation. Make sure all the controls operate correctly then disconnect the power supply of the unit.
● Before installation, please check whether the unit is assembled
with three pieces of rubber pads and square sealing strip.
Moving parts may cause personal injury. Be careful when test the unit. Do not operate the unit
with exterior cover removed.
!
WARNING
STEP 1-SELECTING AN INSTALLATION LOCATION & INSTALLING THE ROOF TOP AIR CONDITIONER
Your air conditioner has been designed for use in recreational vehicles.
Check the roof of the vehicle to determine if it can support both the roof top unit and the ceiling assembly without additional support. Make sure the interior ceiling mounting area will not interfere with existing structures.
Once the location for your air conditioner has been determined. A reinforced and framed roof
hole opening must be cut (if there is no hole) or you may use existing vent holes.
CASE A.
If a roof vent is already present in the desired mounting location for the air conditioner, the following steps must be performed:
1.
Remove all screws which secure the roof vent to the vehicle. Remove the vent and any additional trim. Carefully remove all chalking from around the opening so the surface is clear.
2.
It may be necessary to seal some of the old roof vent mounting screw holes which may fall outside of the air conditioner basepan gasket.
3.
Examine the roof opening size, if the opening is small than 356x356mm, the opening must be enlarged. If the opening exceeds 356x356mm, a mounting plate (frame) must be fabricated to reduce the opening size (See Figure 1).
- 13 -
Page 18
CASE B.
If a roof vent opening is not used,a new opening(see figure 1)will be cut into the vehicl roof. A matching opening will also have to be cut into the interior vehicle ceiling,be careful when cutting the ceiling opening because if the ceiling opening is carpeted,snagging could occur. After the opening in the roof and interior ceiling are the correct size,a framed support structure must be placed between the exterior roof top and interior ceiling.The reinforced framed structure must follow the follwing guidelines:
1. It must be capable of supporting both the
356
weight of the roof top air conditioner and the interior ceiling assembly.
356
19
Figure 1
Hole for Wires
25
2.
It must be capable of holding the roof outer surface and interior ceiling apart and supporting them, so that when the roof top air conditioner and ceiling assembly are bolted together,no collapsing occurs. A
typical support frame is shown in Figure 1.
There must be an opening through the
3.
frame for the power supply wiring.Route the supply wiring through the frame at the same time the support frame is being installed.
CAUTION
1. The roof top air conditioner must be mounted on a level plane from front to rear and side to
side when the vehicle is parked on a level plane. Figure 2 shows maximum allowable degrees that the unit can be mounted above or below level.
2. If the roof of the vehicle is sloped (not level) such that the roof top air conditioner cannot be
mounted within the maximum allowable degree specifications, an exterior leveling shim will need to be added to make the unit level. A typical leveling shim is shown in Figure 3.
3.
Once the roof top air conditioner has been leveled, some additional shimming may be required above the interior ceiling assembly. The roof top air conditioner and the interior ceiling assembly must be square with each other before they are secured together.
4. After the mounting hole area is properly prepared, remove the carton and shipping pads from
around the roof top air conditioner. Carefully lift the unit on top of the vehicle. Do not use the outer plastic shroud for lifting. Place the roof top air conditioner over the prepared mounting hole.
5. The point end (nose) of the shroud must face toward the front of the vehicle.
- 14 -
Page 19
Note: Try you best to put the unit on the horizontal surface for operation. The unit can only operate for a short
Black rubber gasket 400×400 mm
time at the maximum sloping angle of 5º for preventing water leakage.
Above Level 5° Max Below Level 0° Max
Level
Level
Figure 2
356
356
Height Varies to Make Unit Level
Figure 3
Above or Below Level 5° Max
Level
Level
NOTE AIR CONDITIONER DIMENSIONS (ROOF OF UNIT)
- 15 -
Page 20
STEP 2-MOUNTING OUTDOOR UNIT
1.Open the package and take out the outdoor unit
1) When taking out the outdoor unit
after unpacking, do not lift the air outlet grille at the back of outer case (see F igure4-1).
Figure4-1
2.Fix the outdoor unit at the roof of vehicle and then drill holes.
1) Place the outdoor unit at the roof
Figure4-2
of vehicle; lift the outdoor unit and then place the outdoor unit after
drilling holes at the roof of vehicle. Do not drag the outdoor unit. Otherwise, the sealing strip may fall off (see F igure4-2).
- 16 -
Page 21
STEP 3-INSTALLING THE CEILING ASSEMBLY
Make sure that you have properly matched the roof top air conditioner and interior ceiling assembly.Caution before tightening bolts:
1.The applicable thickness of vehicle roof ranges from 30mm~80mm.
2.
Before tightening bolts, screw in the four bolts manually and prohibit screwing forcibly.
3.When screwing bolts, you can use automatic tool. Do not tighten one bolt completely and then
tighten other bolts, in order to prevent sticking of screw thread.
4.The max torque for tightening ranges from 2.3Nm~2.5Nm.
The following step by step instructions must be performed in the following sequence to ensure proper installation.
Carefully take the ceiling assembly out of
1.
the carton (The remote control packed with the ceiling assembly).
Remove the ceiling grille from the ceiling
2.
assembly.
Before installing the outdoor unit of recre-
3.
ational vehicle air conditioner on the vehicle’s top, preinstall the plate of air vent and foam (upper) on the chassis of the
outdoor unit with 4pc of screws (25mm long) (See fig.5-1) .
Then carry the outdoor unit to the vehicle’s
4.
top and align with the openings on the vehicle’s top. Use 2 sets of mounting plate
assembly and 4 screw bolts to mount the outdoor unit (See fig. 5).
You must start (thread) themounting bolts
5.
by hand to avoid cross-threading. DO NOT START THE MOUNTING BOLTS WITH AN AIR GUN. The mounting bolts should
be tightened, process is completed when the basepan gasket has been evenly compressed.
Before installing the air duct assembly of
6.
the indoor unit of recreational vehicle air conditioner, assemble the foam assembly
according to the thickness of the vehicle’s top. After simulated installation, use an appropriate amount of sponge and foam
assembly. Stick the sponge and foam assembly with double faced adhesive tape (prepared by user) (See fig.5-2, 5-3).
Install the foam assembly on the air duct
7.
assembly. Use 4 screw bolts to fix the air duct assembly onto the mounting plate. After connecting the outdoor unit with indoor unit, check whether the foam
assembly has come loose (See fig.5).
Thickness of vehicle roof is from 30mm-80mm
4 bolt
(Max torque is from
2.3Nm~2.5Nm)
fig 5 4 bolt fig 5-1
Gasket
installtion board
bubble
wind-path
Outdoor Unit
Gasket
foam(top)
Plate of air vent
4 screw
- 17 -
Page 22
sponge(Num3,5mm)
foam
foam(Num 3, 14mm)
fig 5-2
foam
foam(under)
fig 5-3
wind-path
STEP 4-ELECTRICAL WIRING
ROUTING 220-240V AC WIRING
!
WARNING
Make sure that all power supply to the unit is disconnected before performing any work on the unit to avoid the possibility of shock or injury and/or damage to the equipment. After the interior ceiling assembly frame is properly secured to the roof top air conditioner, the following electrical connections must be performed.
As shown in fig.7, the outdoor unit has two
1.
sets of outgoing wires, which are power cord (high current) and the control signal wires respectively. The former one should be directly connected to the power supply terminal while
the latter one should be connected to the control signal wire of the indoor unit.
As shown in the picture, connect the
3.
wiring terminals of indoor and outdoor units one by one. Then use a piece of sponge to wrap the wiring terminals together, with each terminal separately encircled by the sponge. Avoid gaps between each wire.
As shown in fig.8, the indoor unit has one
2.
set of control signal wires, with 4 wiring terminals in total.
outdoor electrical wire
fig7 outdoor connect wire
indoor electrical wire
fig8 display board
fig9
- 18 -
Page 23
fig9-1
fig9-2
fig9-3 fig9-4
4 shown in the picture, use a piece of thermal insulating jacket to enclose the wiring
terminals and sponge. Then glue the thermal insulating jacket and fasten it with
cable ties.
Note: 1. Cable ties must be attached to the area with both sponge and thermal
insulating jacket; 2. Before installing the front panel of indoor unit, put the thermal
insulating jacket on top of the air duct.
Insulating sheath
wind-path
fig9-5
fig9-6
front panel
- 19 -
Page 24
STEP 5-COMPLETING THE INSTALLATION
To complete the installation and system checkout requirements, the following steps must be
performed.
Check the thermostat position. Make sure the thermostat is routed through the holding guide
1.
and is not touching any metal surface.
Secure the ceiling grille to the ceiling assembly wind-path with 4 screws. (see Figure 10).
2.
Install the healthy filter and air intake grill. Press “PUSH” and lock with clasps.
3.
Switch on the power supply and check the unit work or not.
4.
Once the indoor unit is assembled, if the gap between the panel and the top of
5.
vehicle is not even, please ask the manufacturer to adjust it according to the
assembly status.
4 screw
front panel
fig 10 filter
wind-path
front grill
- 20 -
Page 25
TROUBLESHOOTING GUIDE
If you have problems with your recreational vehicle air conditioner, check this guide before
contacting your service representative.
TROUBLE SOLUTION
The unit can not start
The unit can not cool the room
The unit is making noise
The unit may not be connected to the power supply correctly.
The roof top air conditioner is not level.
The temperature setting is too high.
The air filter is dirty.
The room was already very hot before the unit was turned on.
The unit is click and gurgle.
POSSIBLE CAUSE
Check the power supply of the vehicle and make sure it is provided correctly.
Mount the roof top air conditioner as level as possible from front to rear and side to side when the vehicle is parked.Make sure that the mounting of the air conditioner is correct and level.
Reset the remote control to a lower temperature setting.
Remove and clean the filter.
Allow a sufficient amount of time for unit to cool the room.
These noise are normal during the operation of the unit.
The unit has water dripping inside
The unit has ice or frost on the coils
The basepan gasket has not been evenly compressed.
The temperature is low inside.
The filter is dirty.
- 21 -
Mounting bolts should be tightened evenly by compressing the basepan gasket.
Select FAN mode at HIGH fan speed.
Remove and clean the filter.
Page 26
NORMAL MAINTENANCE PROCEDURES
ACTIVETY
Remove the cover and wash the condenser coil Twice a year.
Clean the filter (More frequent cleaning may be necessary depending on the air quality)
When the air conditioner FILTER CHECK light on.
HOW TO REMOVE THE AIR FILTER
Push both sides of the air intake grill on the positions marked with “PUSH”. Open the air intake grill and
then take out the healthy filter.
FREQUENCY
front grill
filter.
HOW TO CLEAN THE AIR FILTER
Wash away dust from the air filters with clean water or vacuum the filter with an electric household vacuum cleaner.
HOW TO DISMANTLE CLASP
1.
Concrete dismantle method: use the similar tool in Figure b, align the clasp core and insert it, as Figure a is shown. The inserted depth is about 3mm, as shown in Figure c, which the clasp is detachable. When
you hear a sound, buckle the clasp base with your hands to take out the clasp.
Note: If you insert it too deep, the clasp might be blocked, compulsory dismantle will damage the clasp and it might be invalid. At this moment, use the tool whose diameter is smaller than the clasp to completely
insert the core axis to separate the clasp base and core axis, then it is dismantled.
- 22 -
Page 27
2. Sketch map of claspdismantle tool
Length of handle
(choose appropriate length that fits your hand feeling)
Figure a
Choose appropriate size that fits your hand feeling
Figure b
3.
Sketch map of clasp in different status
Clasp core
Clasp base
about 3mm
Before Demountable status
FAILURE TO FOLLOWING INSTRUCTIONS COULD RESULT IN SERIOUS PERSONAL INJURY
Don’t touch the capacitor terminals without the electric discharge, the capacitor still may have
1.
the high voltage even though the power supply is turned off.
2.
Be careful when you maintain the refrigeration system, which has the high internal pressure.
After
Figure c
!
WARNING
Do not block the filter and the indoor air inlet badly to prevent water leakage.
3.
- 23 -
Page 28
NOTE CONCERNING PROTECTION OF ENVIRONMENT
re-
This product must not be disposed of via normal household waste after its service life, but must be taken to a collection product, the operating instructions or the packaging indicate such disposal procedures. The materials
are recyclable in accordance with their respective symbols. By means of any other form of recycling old appliances you are making an important contribution to the protection
of our environment.
INFORMATION CONCERNING USED REFRIGERANT MEDIUM
This unit is containing fluorinated gases included in the Kyoto protocol. The maintanance and the liquidation must be carried out by qualified personel. Type of refrigerant: R410A The composition of the cooling medium
The quantity of the refrigerant: please see the unit label. Hermetically sealed system.
The value GWP: GWP = Global Warming Potential
2088
station for the recycling of electrical and electronic devices. The symbol on the
use, material recycling or
Please ask your local council where your nearest disposal station is located.
- .
R410A (50% HFC-32, 50% HFC-125)
In case of quality problem or other please contact your local supplier or authorized service center.
Eme
rgency number: 112
PRODUCER
SINCLAIR CORPORATION Ltd.
4 Argyll St.
1
­LONDON W1F 7LD United Kingdom
www.sinclair-world.com This product was manufactured in China (Made in China).
REPRESENTATIVE, TECHNICAL SUPPORT
SINCLAIR Global Group s.r.o. Purkyňova 45
612 00 Brno Czech
Tel.: +420 541 590 140 Fax: +420 541 590 124
epublic
r
sinclair-solutions.com
www. info@sinclair-solutions.com
4
-- 2
Loading...