This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If it needs to install, move or maintain the air conditioner, please contact dealer or local service
center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed
unit. Otherwise, it may cause serious damage or personal injury or death.
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.
Indicates important but not hazard-related information,
used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
Appliance filled with flammable gas R32.
Before use the appliance, read the owner’s manual first.
Before install the appliance, read the installation manual first.
Before repair the appliance, read the service manual first.
The Refrigerant
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R32, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion
under certain conditions. But the flammability of the refrigerant is very low. It can
be ignited only by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
WARNING:
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nearest authorized Service Centre. Any repairs carried out by unqualified personnel
may be dangerous. The appliance shall be stored in a room without continuously
operating ignition sources. (for example: open flames, an operating gas appliance
or an operating electric heater.) Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a floor area larger
than X m .
Refrigerant" for Space X.)
Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s
instructions only. Be aware that refrigrants not contain odour. Read specialist’s
manual.
2
(Please refer to table "a" in section of " Safety Operation of Inflammable
1
Precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid
electric shock.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
2
.
Precautions
WARNING
Maintenance must be performed by qualified
professionals. Otherwise, it may cause personal injury
or damage.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause
malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
If the air conditioner operates under abnormal conditions,
it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.
3
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note
magnet buckle
the circuit-short and
the following table.Air switch should be included
and heating buckle function, it can protect
overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner.Unstable power supply or
incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
4
Precautions
WARNING
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
The appliance must be positioned so that the plug is
accessible.
All wires of indoor unit and outdoor unit should be
connected by a professional.
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.
5
Precautions
WARNING
For the air conditioner with plug, the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Instructions for installation and use of this product are
provided by the manufacturer.
Working temperature range
For some models:
Indoor side DB/WB(℃)Outdoor side DB/WB(℃)
Maximum cooling32/2343/26
Maximum heating27/-24/18
NOTICE:
● The operating temperature range (outdoor temperature) for cooling only unit is
-15℃~ 43℃; for heat pump unit is -15℃~ 43℃.
For some models:
Indoor side DB/WB(℃)Outdoor side DB/WB(℃)
Maximum cooling32/2343/26
Maximum heating27/-24/18
NOTICE:
● The operating temperature range (outdoor temperature) for cooling only unit is
-15℃~ 43℃; for heat pump unit is -20℃~ 43℃.
6
Parts Name
Indoor Unit
(Display content or position may be different from above
graphics, please refer to actual products)
air inlet
panel
filter
aux.button
horizontal louver
air outlet
remote control
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
7
Parts Name
Display
For some model:
cooling
indicator
heating
indicator
For some model:
heating
indicator
cooling
indicator
For some model:
power
indicator
temp.
indicator
For some model:
drying
indicator
temp.
indicator
receiver
window
display
receiver
window
display
W R G
drying
indicator
temp.
indicator
power
indicator
receiver
window
display
For some model:
heating
indicator
cooling
indicator
power
indicator
temp.
indicator
drying
indicator
For some model:
Power indicatior
temp.
indicator
receiver
window
Power LED color indicator:
Green-status-ON.
Red -status-OFF.
Mode LED color indicator:
White-W-Cool Mode-
Red-R-Heat ModeGreen-G-Dry Mode-
W
(only for heating model)
R
G
display
receiver
window
display
temp.
indicator
receiver
window
W R O
Display content or position may be different from above graphics, please refer to actual
products.
Power LED color indicator:
Green-status-ON.
Red -status-OFF.
Mode LED color indicator:
White-W-Cool ModeRed-R-Heat Mode-
Orange-O-Dry Mode-
W
(only for heating model)
R
O
8
Buttons on remote controller
1
2
4
7
9
11
3
5
6
8
10
12
10
11
12
1
ON/OFF button
2
MODE button
3
FAN button
4
SWING button
5
TURBO button
6
7
8
9
▲
▲/ button
SLEEP button
TEMP button
WiFi button
LIGHT button
CLOCK button
TIMER ON / TIMER OFF
button
Introduction for icons on display screen
I feel
Operation mode
Auto mode
Cool mode
Dry mode
Fan mode
Heat mode
Clock
Sleep mode
Light
:Set temp.
Temp. display type
:Outdoor ambient temp.
:Indoor ambient temp.
9
Set fan speed
Send signal
Turbo mode
8℃ heating function
Set temperature
This is a general remote controller.Some
WiFi
models have this function while some
{
do not. Please refer to the actual models.
Set time
TIMER ON /
TIMER OFF
Child lock
Up & down swing
Introduction for buttons on remote controller
Note:
● This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press
the corresponding button on the remote controller that the unit will keep the
original running status.
● After putting through the power, the air conditioner will give out a sound.
Operation indictor is ON (red indicator, the colour is different for different models).
After that, you can operate the air conditioner by using remote controller.
●
Under on status, pressing the button on the remote controller, the signal icon " "
on the display of remote controller will blink once and the air conditioner will give
out a “de” sound, which means the signal has been sent to the air conditioner.
● Under off status, set temperature and clock icon will be displayed on the display
of remote controller (If timer on, timer off and light functions are set, the corre sponding icons will be displayed on the display of remote controller at the same
time); Under on status, the display will show the corresponding set function icons.
ON/OFF button
1
Press this button to turn on the unit. Press this button again to turn off the unit.
MODE button
2
Press this button to select your required operation mode.
AUTOCOOLFANDRYHEAT
● When selecting auto mode, air conditioner will operate automatically according
to ex-factory setting. Set temperature can’t be adjusted and will not be displayed
as well. Press "FAN" button can adjust fan speed. Press "SWING" button can
adjust fan blowing angle.
● After selecting cool mode, air conditioner will operate under cool mode. Cool
indicator on indoor unit is ON(This indicator is not available for some models).
Press "▲" or " " button to adjust set temperature. Press "FAN" button to adjust
fan speed. Press "SWING" button to adjust fan blowing angle.
● When selecting dry mode, the air conditioner operates at low speed under dry
mode. Dry indicator on indoor unit is ON(This indicator is not available for some
models). Under dry mode, fan speed can’t be adjusted. Press "SWING" button
to adjust fan blowing angle.
● When selecting fan mode, the air conditioner will only blow fan, no cooling and
no heating. Press "FAN" button to adjust fan speed. Press "SWING" button to
adjust fan blowing angle.
● When selecting heating mode, the air conditioner operates under heat mode.
Heat indicator on indoor unit is ON(This indicator is not available for some models).
▲
10
Introduction for buttons on remote controller
Press "▲" or " " button to adjust set temperature. Press "FAN" button to adjust
fan speed. Press "SWING" button to adjust fan blowing angle. (Cooling only unit
won’t receive heating mode signal. If setting heat mode with remote controller,
press ON/OFF button can’t start up the unit).
Note:
● For preventing cold air, after starting up heating mode, indoor unit will delay 1~5
minutes to blow air (actual delay time is depend on indoor ambient temperature).
● Set temperature range from remote controller: 16~30℃; Fan speed: auto, low
speed, medium speed, high speed.
FAN button
3
Pressing this button can set fan speed circularly as: auto (AUTO), low( ) ,medium
( ), high( ).
Note:
● Under AUTO speed, air conditioner will select proper fan speed automatically
according to ex-factory setting.
● Fan speed under dry mode is low speed.
●
X-FAN function
displayed and the indoor fan will continue operation for a few minutes in order to dry
the indoor unit even though you have turned off the unit. After energization, X-FAN
OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
This function indicates that moisture on evaporator of indoor unit will be blowed
after the unit is stopped to avoid mould.
●
Having set X-FAN function on: After turning off the unit by pressing ON/OFF
button indoor fan will continue running for a few minutes. at low speed. In this
period, Hold fan speed button for 2s to stop indoor fan directly.
●
Having set X-FAN function off: After turning off the unit by pressing ON/OFF
button, the complete unit will be off directly.
▲
Auto
Hold fan speed button for 2s in COOL or DRY mode, the icon “ ” is
SWING button
4
Press this button can select up&down swing angle. Fan blow angle can be selected
circularly as below:
no display
(horizontal louvers stops
at current position)
11
Introduction for buttons on remote controller
● When selecting " ", air conditioner is blowing fan automatically. Horizontal
louver will automatically swing up & down at maximum angle.
● When selecting " 、 、 、
、
● When selecting " 、
● Hold " " button above 2s to set your required swing angle. When reaching your
required angle, release the button.
、
Note:
" 、 、 " may not be available. When air conditioner receives this signal, the
air conditioner will blow fan automatically.
TURBO button
5
Under COOL or HEAT mode, press this button to turn to quick COOL or quick
HEAT mode. " " icon is displayed on remote controller. Press this button again
to exit turbo function and " " icon will disappear.
▲
▲/ button
6
● Press "▲" or " " button once increase or decrease set temperature 1℃.
Holding "▲" or " " button, 2s later, set temperature on remote controller will
change quickly. On releasing button after setting is finished, temperature indica-
tor on indoor unit will change accordingly. (Temperature can’t be adjusted under
auto mode)
● When setting TIMER ON, TIMER OFF or CLOCK, press "▲" or " " button to
adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons) When setting
TIMER ON, TIMER OFF or CLOCK, press "▲" or " " button to adjust time. (Refer
to CLOCK, TIMER ON, TIMER OFF buttons)
▲
▲
▲
▲
SLEEP button
7
Under COOL or HEAT mode, press this button to start up sleep function.
" " icon is displayed on remote controller. Press this button again to cancel sleep
function and " " icon will disappear.
TEMP button
8
By pressing this button, you can see indoor set temperature, indoor ambient temperature or outdoor ambient temperature on indoor unit’s display. The setting on
remote controlleris selected circularly as below:
no display
12
Introduction for buttons on remote controller
● When selecting " " or no display with remote controller, temperature indicator
on indoor unit displays set temperature.
● When selecting " " with remote controller, temperature indicator on indoor unit
displays indoor ambient temperature.
● When selecting " " with remote controller, temperature indicator on indoor unit
displays outdoor ambient temperature.
Note:
●
Outdoor temperature display is not available for some models. At that time, indoor
unit receives " " signal, while it displays indoor set temperature.
● It’s defaulted to display set temperature when turning on the unit. There is no
display in the remote controller.
● Only for the models whose indoor unit has dual-8 display.
● When selecting displaying of indoor or outdoor ambient temperature, indoor
temperature indicator displays corresponding temperature and automatically turn
to display set temperature after three or five seconds.
WiFi button
9
Press " WiFi " button to turn on or turn off WiFi function. When WiFi function is
turned on, the " WiFi " icon will be displayed on remote controller; Under status
of remote controller off, press "MODE" and " WiFi " buttons simultaneously for 1s,
WiFi module
● This function is only available for some models.
will restore to factory default setting.
LIGHT button
10
Press this button to turn off display light on indoor unit. " " icon on remote
controller disappears. Press this button again to turn on display light. " " icon is
displayed.
CLOCK button
11
Press this button to set clock time. " " icon on remote controller will blink. Press
"▲" or " " button within 5s to set clock time. Each pressing of "▲" or " " button,
clock time will increase or decrease 1 minute. If hold "▲" or " " button, 2s later,
time will change quickly. Release this button when reaching your required time.
▲▲
▲
Note:
● Clock time adopts 24-hour mode.
● The interval between two operation can’t exceeds 5s. Otherwise, remote contro-
ller will quit setting status. Operation for TIMER ON/TIMER OFF is the same.
TIMER ON / TIMER OFF button
12
13
Introduction for buttons on remote controller
● TIMER ON button
"TIMER ON" button can set the time for timer on. After pressing this button, " "
icon disappears and the word "ON" on remote controller blinks. Press "▲" or
▲
" "button to adjust TIMER ON setting. After each pressing "▲" or " " button,TIMER ON setting will increase or decrease 1min. Hold "▲" or " " button, 2s
later, the time will change quickly until reaching your required time.
resumes displaying. Cancel TIMER ON: Under the condition that TIMER ON is
started up, press "TIMER ON" button to cancel it.
● TIMER OFF button
"TIMER OFF" button can set the time for timer off. After pressing this button," "
icon disappears and the word "OFF" on remote controller blinks. Press "▲" or
▲
" " button to adjust TIMER OFF setting. After each pressing "▲" or " " button, TIMER OFF setting will increase or decrease 1min. Hold "▲" or " " button, 2s
later, the time will change quickly until reaching your required time.
Press "TIMER OFF" word "OFF" will stop blinking. " " icon resumes displaying.
Cancel TIMER OFF. Under the condition that TIMER OFF is started up, press
"TIMER OFF" button to cancel it.
Note:
● Under on and off status, you can set TIMER OFF or TIMER ON simultaneously.
● Before setting TIMER ON or TIMER OFF, please adjust the clock time.
● After starting up TIMER ON or TIMER OFF, set the constant circulating valid.
After that, air conditioner will be turned on or turned off according to setting time.
ON/OFF button has no effect on setting. If you don’t need this function, please
use remote controller to cancel it.
▲
▲
▲
▲
Health function
Health function will be set during operation of indoor fan.
Turn off the unit will also turn off health function.
This function is only available for some models.
Function introduction for combination buttons
Energy-saving function
Under cooling mode, press "TEMP" and " CLOCK" buttons simultaneously to
start up or turn off energy-saving function. When energy-saving function is started
up, "SE" will be shown on remote controller, and air conditioner will adjust the set
temperature automatically according to ex-factory setting to reach to the best
energy-saving effect. Press "TEMP" and "CLOCK" buttons simultaneously again to
exit energy-saving function.
Note:
● Under energy-saving function, fan speed is defaulted at auto speed and it can’t
be adjusted.
●
Under energy-saving function, set temperature can’t be adjusted. Press "TURBO"
button and the remote controller won’t send signal.
14
Function introduction for combination buttons
● Sleep function and energy-saving function can’t operate at the same time. If
energy-saving function has been set under cooling mode, press sleep button will
cancel energy-saving function. If sleep function has been set under cooling
mode, start up the energy-saving function will cancel sleep function.
8℃ heating function
Under heating mode, press "TEMP" and "CLOCK" buttons simultaneously to start
up or turn off 8
will be shown on remote controller, and the air conditioner keep the heating status
at 8
heating function.
. Press "TEMP" and "CLOCK" buttons simultaneously again to exit 8
℃
Note:
● Under 8℃ heating function, fan speed is defaulted at auto speed and it can’t be
adjusted.
● Under 8℃ heating function, set temperature can’t be adjusted. Press "TURBO"
button and the remote controller won’t send signal.
● Sleep function and 8℃ heating function can’t operate at the same time. If 8
heating function has been set under cooling mode, press sleep button will cancel
8℃ heating function. If sleep function has been set under cooling mode, start up
the 8℃ heating function will cancel sleep function.
● Under ℉ temperature display, the remote controller will display 46℉ heating.
Child lock function
Press "▲" and " " simultaneously to turn on or turn off child lock function. When
child lock function is on, " " icon is displayed on remote controller. If you operate
the remote controller, the " " icon will blink three times without sending signal to
the unit.
heating function. When this function is started up, " " and "8℃"
℃
℃
▲
℃
Temperature display switchover function
Under OFF status, press " " and "MODE" buttons simultaneously to switch temperature display between ℃ and ℉.
▲
I FEEL Function
Press "▲" and "MODE" buttons simultaneously to start I FEEL function and " "
will be displayed on the remote controller. After this function is set, the remote
controller will send the detected ambient temperature to the controller and the unit
will automatically adjust the indoor temperature according to the detected tempera-
ture. Press this two buttons simultaneously again to close I FEEL function and " "
will disappear.
● Please put the remote controller near user when this function is set. Do not put
the remote controller near the object of high temperature o
order to avoid detecting inaccurate ambient temperature.When I FEEL function
is turned on, the remote controller should be put within the area where indoor
unit can receive the signal sent by the remote controller.
r low temperature in
15
Operation guide
After putting through the power, press "ON/OFF" button on remote controller to
1.
turn on the air conditioner.
Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN,
2.
HEAT.
Press "▲" or " " button to set your required temperature. (Temperature can’t
3.
be adjusted under auto mode).
Press "FAN" button to set your required fan speed: auto, low, medium and high
4.
speed.
Press "SWING" button to select fan blowing angle.
5.
▲
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
with " ", as shown in the fig, and then push out
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
signal senderbattery
reinstall
remove
Cover of battery box
NOTICE
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
● Signal may be interfered easily in the room where there is fluorescent lamp
or wireless telephone; remote controller should be close to indoor unit during
operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please
replace batteries.
16
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button
WARNING:
Use insulated object to press the auto button
Clean and maintenance
WARNING
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
NOTICE:
● Do not remove the panel when cleaning it.
17
Clean and Maintenance
Open panel
1
Pull out the panel to a certain ● Use dust catcher or water to
2
3
the water (below 45℃) to clean
it, and then put it in a shady
and cool place to dry.
4
panel cover tightly.
WARNING
operation environment, clean frequency can be increased.
18
Clean and Maintenance
NOTICE: Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether air switch, plug and socket are in good condition.
4. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
NOTICE: Checking after use-season
1. Disconnect power supply.
3. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
19
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
PhenomenonCheck itemsSolution
Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
has no
action.
No air
emitted
from
indoor
unit
● Whether it's interfered severely
(such as static electricity, stable
voltage)?
● Whether remote controller is
within the signal receiving
range?
● Whether there are obstacles?
● Whether remote controller is
pointing at the receiving
window?
● Is sensitivity of remote contro ller low; fuzzy display and no
display?
● No display when operating
remote controller?
● Fluorescent lamp in room?
● Air inlet or air outlet of indoor
unit is blocked?
● Under heating mode, indoor
temperature is reached to set
temperature?
● Heating mode is turned on just
now?
● Pull out the plug. Reinsert
the plug after about 3min, and
then turn on the unit again.
● Signal receiving range is 8m.
● Remove obstacles.
●
Select proper angle and point
the remote controller at the re-
ceiving window on indoor unit.
● Check the batteries. If the
power of batteries is too low,
please replace them.
● Check whether remote cont-
roller appears to be damaged.
If yes, replace it.
● Take the remote controller
close to indoor unit.
and then try it again.
● Eliminate obstacles.
● After reaching to set temper ature, indoor unit will stop bl-
owing out air.
● In order to prevent blowing
out cold air, indoor unit will be
started after delaying for sev eral minutes, which is a nor-
mal phenomenon.
20
Malfunction analysis
PhenomenonCheck itemsSolution
Air conditioner can’t
operate
Mist is emitted from
indoor unit’s
air outlet
Set temperature can’t
be adjusted
● Power failure?
● Is plug loose?
● Air switch trips off or fuse is
burnt out?
● Wiring has malfunction?
● Unit has restarted immediately
after stopping operation?
● Whether the function setting
for remote controller is
correct?
● Indoor temperature and hum idity is high?
● Unit is operating under auto
mode?
● Your required temperature
exceeds the set temperature
range?
● Wait until power recovery.
● Reinsert the plug.
● Ask professional to replace
air switch or fuse.
● Ask professional to replace it.
● Wait for 3min, and then turn
on the unit again.
● Reset the function.
● Because indoor air is cooled
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
● Temperature can’t be adju-
sted under auto mode.
Please switch the operation
mode if you need to adjust
temperature.
● Set temperature range:
16℃~30℃.
Cooling
(heating)
effect is
not good.
● Voltage is too low?
● Filter is dirty?
● Set temperature is in proper
range?
● Door and window are open?● Close door and window.
● Wait until the voltage
resumes normal.
● Adjust temperature to proper
range.
21
Malfunction analysis
PhenomenonCheck itemsSolution
Odours are
emitted
Air conditioner operates
abnormally
“Water
noise
Cracking
noise
● Whether there’s odour source,
such as furniture and cigarette,
etc.
● Whether there’s interference,
such as thunder, wireless
devices, etc.
● Air conditioner is turned on or
turned off just now?
● Air conditioner is turned on or
turned off just now?
● Eliminate the odour source.
● Disconnect power, put back
power, and then turn on the
unit again.
● The noise is the sound of
the unit, which is a normal
phenomenon.
● This is the sound of friction
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.
22
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will
ation of error code.
Error code
E5
E8
U8
H6
C5
F0
F1
F2
H3
E1
E6
Note: If there're other error codes, please contact qualified professionals for
service.
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
It
can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
Troubleshooting
WARNING
■ When below phenomenon occurs, please turn off air conditioner and discon-
for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Air switch trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
23
Safety operation of flammable refrigerant
Qualification requirement for installation and maintenance man
All the work men who are engaging in the refrigeration system should bear the
valid certification awarded by the authoritative organization and the qualification
for dealing with the refrigeration system recognized by this industry. If it needs
other technician to maintain and repair the appliance, they should be supervised
by the person who bears the qualification for using the flammable refrigerant.
It can only be repaired by the method suggested by the equipment’s manufacturer.
Installation notes
The air conditioner is not allowed to use in a room that has running fire (such as fire
source, working coal gas ware, operating heater).
It is not allowed to drill hole or burn the connection pipe.
The air conditioner must be installed in a room that is larger than the minimum room
area. The minimum room area is shown on the nameplate or following table a.
Leak test is a must after installation.
Check whether the maintenance area or the room area meet the requirement of the
nameplate.
- It’s only allowed to be operated in the rooms that meet the requirement of the
nameplate.
Check whether the maintenance area is well-ventilated.
- The continuous ventilation status should be kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance area.
- The naked flame is prohibited in the maintenance area; and the “no smoking”
warning board should be hanged.
Check whether the appliance mark is in good condition.
- Replace the vague or damaged warning mark.
Welding
If you should cut or weld the refrigerant system pipes in the process of maintaining,
please follow the steps as below:
24
Safety operation of flammable refrigerant
a. Shut down the unit and cut power supply
b. Eliminate the refrigerant
c. Vacuuming
d. Clean it with N2 gas
e. Cutting or welding
f. Carry back to the service spot for welding
The refrigerant should be recycled into the specialized storage tank.
Make sure that there isn’t any naked flame near the outlet of the vacuum pump
and it’s well-ventilated.
Filling the refrigerant
Use the refrigerant filling appliances specialized for R32. Make sure that different
kinds of refrigerant won’t contaminate with each other.
The refrigerant tank should be kept upright at the time of filling refrigerant.
Stick the label on the system after filling is finished (or haven’t finished).
Don’t overfilling.
After filling is finished, please do the leakage detection before test running; another
time of leak detection should be done when it’s removed.
Safety instructions for transportation and storage
Please use the flammable gas detector to check before unload and open the container.
No fire source and smoking.
According to the local rules and laws.
25
Installation dimension diagram
At least 15cm
Space to the ceiling
At least 15cm
Space to the wall
At least 300cm
Space to the wall
At least 15cm
Space to the obstruction
At least 250cm
26
Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions.
Warning
When installing or relocating the unit, be sure to keep the refrigerant
circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause
system pressure rise or compressor rupture, resulting in injury.
When installing or moving this unit, do not charge the refrigerant which
is not comply with that on the nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical
malfunction or even series safety accident.
When refrigerant needs to be recovered during relocating or repairing the
unit, be sure that the unit is running in cooling mode.Then, fully close the
valve at high pressure side (liquid valve).About 30-40 seconds later, fully
close the valve at low pressure side (gas valve), immediately stop the unit
and disconnect power. Please note that the time for refrigerant recovery
should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in and cause
pressure rise or compressor rupture, resulting in injury.
During refrigerant recovery, make sure that liquid valve and gas valve are
fully closed and power is disconnected before detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is not
yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
When installing the unit, make sure that connection pipe is securely
connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not
yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
Prohibit installing the unit at the place where there may be leaked corrosive
gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents.
Do not use extension cords for electrical connections. If the electric wire
is not long enough, please contact a local service center authorized
and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the
indoor and outdoor units. Firmly clamp the wires so that their terminals
receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure
wire terminals may cause electric shock or fire.
● Please contact the local agent for installation.
Selection of installation location
Basic requirement
Installing the unit in the following places maycause malfunction. If it is unavoidable,
please consult the local dealer:
1. The place with strong heat sources,
volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical
equipment).
3. The place near coast area.
4.
The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. The appliance shall nost be installed in the laundry.
Indoor unit
1. There should be no obstruction near air inlet .
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach for children.
5. The location should be able to withstand the weight of indoor unit and won't
increase noise and vibration.
6. The appliance must be installed 2.5m above floor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from fluorescent lamp.
vapors, flammable or explosive gas
, or
28
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety. For models with a power plug, make sure the plug is
within reach after installation.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnec tion cable away from the copper tube.
9.
The appliance shall be installed in accordance with national wiring regulations.
10. Appliance shall be installed, operated and stored in a room with a floor area
larger than “X”m (see table 1).
Please notice that the unit is filled with flammable gas R32. Inappropriate
treatment of the unit involves the risk of severe damages of people and
material. Details to this refrigerant are found in chapter “refrigerant”.
2
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
29
Installation of indoor unit
Step one: choosing installation location
rm it with the client.
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
Step three: open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
QB
Wall
Space
to the
wall
above
150mm
Left
Φ55mm
Rear piping hole
QD:
Wall
Space
to the
wall
above
150mm
Left
Φ55mm
Rear piping hole
Mark in the middle of it
Mark in the middle of it
Level meter
Level meter
Wall
Space
to the
wall
above
150mm
Right
Φ55mm
Rear piping hole
Wall
Space
to the
wall
above
150mm
Right
Φ55mm
Rear piping hole
QC:
Wall
Space
to the
wall
above
150mm
Left
Φ55mm
Rear piping hole
QE:
Wall
Space
to the
wall
above
150mm
Left
Φ70mm
Rear piping hole
Mark in the middle of it
Mark in the middle of it
Level meter
Level meter
Wall
Space
to the
wall
above
150mm
Right
Φ55mm
Rear piping hole
Wall
Space
to the
wall
above
150mm
Right
Φ70mm
Rear piping hole
2. Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe
position.In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
30
Installation of indoor unit
Note:
● Pay attention to dust prevention and
take relevant safety measures when
opening the hole.
● The plastic expansion particles are
not provided and should be bought
locally.
Step four: outlet pipe
1. The pipe can be led out in the
direction of right, rear right, left or
rear left.
left
rear right
right
rear left
Indoor
outdoor
Φ55/
5-10
2. When select leading out the pipe
from left or right, please cut off the
corresponding hole on the bottom
case.
leftright
cut off
the hole
Φ70
1. Aim the pipe joint at the corresponding
bellmouth.
union nutpipe joint
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
pipe
31
Installation of indoor unit
torque wrench
indoor pipe
open-end
wrench
union nut
pipe
Hex nut diameter Tightening torque (N.m)
Φ 9.52
4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and
then wrap it with tape.
Step six: install drain hose
1. Connect the drain hose to the outlet pipe of
indoor unit.
outlet pipe
2. Bind the joint with tape.
tape
Note:
● Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
● The plastic expansion particles are
not provided.
drain hose
Φ 6
Φ 12
Φ 16
Φ 19
15~20
30~40
45~55
60~65
70~75
insulating pipe
outlet
pipe
drain hose
insulating pipe
drain hose
Step seven: connect wire of indoor unit
1. Open the panel, remove the screw
on the wiring cover and then take
down the cover.
32
panel
screw
wiring cover
Installation of indoor unit
2. Make the power connection wire go
through the cable-cross hole at the back
cable-cross
hole
of indoor unit and then pull it out from
the front side.
power connection
wire
3. Remove the wire clip; connect the power connection wire to the wiring terminal
according to the color; tighten the screw and then fix the power connection wire
with wire clip.
N(1) 232
bluebrown
black
Outdoor unit connection
Note: the wiring board is for reference only, please refer to the actual one.
yellowgreen
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
33
Installation of indoor unit
drain hose
upper hook
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor and
indoor unit
outdoor power cord
gas
pipe
band
liquid pipe
drain hose
2. Reserve a certain length of drain
hose and power cord for installation
when binding them. When binding to
a certain degree, separate the indoor
power and then separate the drain
hose.
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
connection pipe
indoor power cord
band
3. Bind them evenly.
4. The liquid pipe and gas pipe should
be bound separately at the end.
Note:
● The power cord and control wire
can't be crossed or winding.
● The drain hose should be bound
at the bottom.
indoor
wall pipe
outdoor
sealing gum
lower hook of
wall-mounting frame
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
34
Check after installation
Items to be checkedPossible malfunction
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
Is water drained well?
(heating) capacity.
It may cause condensation and water
dripping.
It may cause condensation and water
dripping.
Is the voltage of power supply according to the voltage marked on the
nameplate?
Is electric wiring and pipeline installed
correctly?
Is the unit grounded securely?It may cause electric leakage.
Does the power cord follow the speci-
Is there any obstruction in the air inlet
and outlet?
The dust and sundries caused during
installation are removed?
The gas valve and liquid valve of
connection pipe are open completely?
Is the inlet and outlet of piping hole
been covered?
It may cause malfunction or damaging
the parts.
It may cause malfunction or damaging
the parts.
It may cause malfunction or damaging
the parts.
(heating) capacity.
It may cause malfunction or damaging
the parts.
(heating) capacity.
It may cause insufficient cooling
(heating) capacity or waster eletricity.
Test operation
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.
35
Configuration of connection pipe
1. Standard length of connection pipe
● 5m、7.5m、8m
2. Min length of connection pipe
For the unit with standard connection pipe of 5m, there is no limitation for the
min length of connection pipe. For the unit with standard connection pipe of
7.5m and 8m, the min length of connection pipe is 3m.
3. Max length of connection pipe
Sheet 1 Max length of connection pipe Unit: m
capacitycapacity
5000Btu/h
(1465W)
7000Btu/h
(2051W)
9000Btu/h
(2637W)
12000Btu/h
(3516W)
18000Btu/h
(5274W)
4. The calculation method of additional refrigerant oil and refrigerant charging amount
after prolonging connection pipe
After the length of connection pipe is prolonged for 10m at the basis of standard
length, you should add 5ml of refrigerant oil for each additional 5m of connection
pipe.
The calculation method of additional refrigerant charging amount (on the basis
Basing on the length of standard pipe, add refrigerant according to the
(2)
requirement as shown in the table. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See Sheet 2.
Max length of
connection pipe
1525
1530
1530
2030
2530
24000Btu/h
(7032W)
28000Btu/h
(8204W)
36000Btu/h
(10548W)
42000Btu/h
(12306W)
48000Btu/h
(14064W)
Max length of
connection pipe
36
Configuration of connection pipe
Sheet 2. Additional refrigerant charging amount for R32
Diameter of connection pipe mm
Liquid pipeGas pipe
Ф6
Ф6 or Ф9.5
Ф12
Ф16
Ф19
Ф22.2
Note: The additional refrigerant charging amount in Sheet 2 is recommended
value, not compulsory.
Ф9.5 or Ф12
Ф16 or Ф19
Ф19 or Ф22.2
Ф25.4 or Ф31.8
_
_
Indoor unit throttleOutdoor unit throttle
Cooling only,
cooling and heating
(g / m)(g / m)
16
40
80
136
200200
Cooling only
(g / m)
12
12
24
48
280280
cooling and
heating
16
40
96
96
200
280
37
Pipe expanding method
pipe
pipe
smooth surface
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
the distance of indoor unit and
outdoor unit.
● Cut the required pipe with pipe cutter.
pipe cutter
E: Expand the port
● Expand the port with expander.
hard
expander
mold
pipe
leaningunevenburr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into
the pipe.
shaper
downwards
C: Put on suitable insulating pipe
D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve;
install the union nut on the pipe.
union pipe
Note:
● "A" is different according to the
diameter, please refer to the sheet
below:
Outer diameter
(mm)
Φ6 - 6.35(1/4")
Φ9.52(3/8")
Φ12-12.7(1/2")
Φ15.8-16(5/8")
A(mm)
MaxMin
1.30.7
1.61.0
1.81.0
2.42.2
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
improper expanding
pipe
the length is equal
38
leaning
damaged
surface
crack uneven
thickness
Electric schematic diagram
ASH-09BIF/I, ASH-13BIF/I
ASH-18BIF/I, ASH-24BIF/I
Rating label
Energy label
NOTE CONCERNING PROTECTION OF
ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be
taken to a collection station for the recycling of electrical and electronic devices. The symbol on the
product, the operating instructions or the packaging indicate such disposal procedures. The materials
are recyclable in accordance with their respective symbols. By means of re-use, material recycling or
any other form of recycling old appliances you are making an important contribution to the protection
of our environment. Please ask your local council where your nearest disposal station is located.
INFORMATION CONCERNING USED REFRIGERANT
MEDIUM
This unit is containing fluorinated gases included in the Kyoto protocol. The maintenance and the liquidation must
be carried out by qualified personnel.
Type of refrigerant: R32
The quantity of the refrigerant: please see the unit label.
The value GWP: 675 (1 kg R32 = 0,675 t CO2 eq)
GWP = Global Warming Potential
Appliance filled with flammable gas R32.
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112
PRODUCER
SINCLAIR CORPORATION Ltd.
1-4 Argyll St.
London W1F 7LD
Great Britain
www.sinclair-world.com
This product was manufactured in China (Made in China).
REPRESENTATIVE
SINCLAIR EUROPE spol. s r.o.
Purkynova 45
612 00 Brno
Czech Republic
TECHNICAL SUPPORT
NEPA spol. s r.o.
Purkynova 45
612 00 Brno
Czech Republic