Sinclair ASH-18AIK, ASH-09AIK, ASH-24AIK, ASH-13AIK User Manual

USER'S MANUAL
EN
KITE
ASH-09AIK, ASH-13AIK ASH-18AIK, ASH-24AIK
SERIES
“Originalinstructions”
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
Table of Contents
Owner’s Manual
0
Safety Precautions
1
Unit Specifications and Features
.............................................04
........06
SAFETY
FIRST
2
Manual Operation (Without Remote)
.......................................
11
Care and Maintenance
3
.................................................................. 12
Troubleshooting
4
5
European Disposal Guidelines
........................................................................................... 14
............................................. 18
Safety Precautions
Read Safety Precautions Before Installation
Incorrect installation due to ignoring instructions can cause serious damage or injury.
seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.
This symbol indicates that ignoring instructions may cause death or serious
WARNING
CAUTION
injury.
This symbol indicates that ignoring instructions may cause moderate injury to your person, or damage to your appliance or other property.
WARNING
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
The
INSTALLATION WARNINGS
Ask an authorized dealer to install this air conditioner. Inappropriate installation may cause water leakage, electric shock, or fire.
All repairs, maintenance and relocation of this unit must be performed by an authorized service technician. Inappropriate repairs can lead to serious injury or product failure.
WARNINGS FOR PRODUCT USE
If an abnormal situation arises (like a burning smell), immediately turn off the unit and pull the power plug. Call your dealer for instructions to avoid electric shock, fire or injury.
Do not insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.
Do not use flammable sprays such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.
Do not operate the air conditioner in places near or around combustible gases. Emitted gas may collect around the unit and cause explosion.
Do not operate the air conditioner in a wet room (e.g., bathroom or laundry room). This can cause electrical shock and cause the product to deteriorate.
Do not expose your body directly to cool air for a prolonged period of time.
ELECTRICAL WARNINGS
Only use the specified power cord. If the power cord is damaged, it must be replaced by the manufacturer or certified service agent.
Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can cause fire or electric shock.
Do not pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the cord can damage it, which can lead to fire or electric shock.
Do not use an extension cord, manually extend the power cord, or connect other appliances to the same outlet as the air conditioner. Poor electrical connections, poor insulation, and insufficient voltage can cause fire.
CLEANING AND MAINTENANCE WARNINGS
Turn off the device and pull the plug before cleaning. Failure to do so can cause electrical shock.
Do not clean the air conditioner with excessive amounts of water.
Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents
can cause fire or deformation.
CAUTION
If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
Turn off the air conditioner and unplug the unit if you are not going to use it for a long time.
Turn off and unplug the unit during storms.
Make sure that water condensation can drain unhindered from the unit.
Do not operate the air conditioner with wet hands. This may cause electric shock.
Do not use device for any other purpose than its intended use.
Do not climb onto or place objects on top of the outdoor unit.
Do not allow the air conditioner to operate for long periods of time with doors or windows open,
or if the humidity is very high.
Unit Specifications and Features
Unit Parts
Air Filter (pull out)
Front Panel
Louver
Display window
Power Cable (Some Units)
Remote Control
Remote Holder (Some Units)
“ ” for 3 seconds when:
• TIMER ON is set
• FRESH, SWING, TURBO, or SILENCE features are turned on
“ ” for 3 seconds when:
• TIMER OFF is set
• FRESH, SWING, TURBO, or SILENCE features are turned off
“ ” when anti-cold air feature is turned on
“ ” when defrosting
“ ” when unit is self-cleaning
“ ” when freeze protection is turned on
“ ” when WIFI Control feature is activated(some units)
“ ”
When ECO function(some units) is activated, the
,
,
illuminates gradually one by one as --
-- --set temperature-- ...... in one second interval.
NOT E:
In Fan mode, the unit will display the room temperature.
A guide on using the infrared remote is not included in this literature package.
In other modes, the unit will display your temperature setting.
Display Code
Meanings
Achieving Optimal Performance
Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature ranges. When your air conditioner is used outside of these ranges, certain safety protection features will activate and cause the unit to perform less than optimally.
Inverter Split Type
Room Temperature
Outdoor Temperature
Fixed-speed Type
Room
Temperature
Outdoor
Temperature
(For models with low-temp cooling systems)
(For special tropical models)
COOL mode HEAT mode DRY mode
17°C - 32°C (63°F - 90°F)
0°C - 50°C (32°F - 122°F)
-15°C - 50°C (5°F - 122°F)
(For models with low temp. cooling systems.)
COOL mode
17°-32°C (63°-90°F)
18°-43°C (64°-109°F)
-7°-43°C (19°-109°F)
18°-52°C (64°-126°F)
0°C - 30°C (32°F - 86°F)
-15°C - 30°C (5°F - 86°F)
10°C - 32°C (50°F - 90°F)
0°C - 50°C (32°F - 122°F)
HEAT mode
O°-30°C (32°-86°F)
-7°-24°C (19°-75°F)
FOR UNITS WITH AUXILARY ELECTRIC HEATER
When outside temperature is below 0°C (
32°F
), we strongly recommend keeping the unit plugged in at all timers to ensure smooth ongoing performance.
DRY mode
10°-32°C (50°-90°F)
11°-43°C (52°-109°F)
18°-43°C (64°-109°F)
18°-52°C (64°-126°F)
(For special tropical models)
To further optimize the performance of your unit, do the following:
Keep doors and windows closed.
Limit energy usage by using TIMER ON and TIMER OFF functions.
Do not block air inlets or outlets.
Regularly inspect and clean air filters.
For a detailed explanation of each function, refer to the Remote Control Manual.
Other Features
Auto-Restart
If the unit loses power, it will automatically restart with the prior settings once power has been restored.
Anti-mildew (some units)
When turning off the unit from COOL, AUTO (COOL), or DRY modes, the air conditioner will continue operate at very low power to dry up condensed water and prevent mildew growth.
Mute Operation (some units)
Press the LED button on the remote control can turn off the indoor screen display, and also turn off the air conditioner buzzer, which create a comfortable and quiet environment.
Wi-Fi Control (some units)
Wi-Fi control allows you to control your air conditioner using your mobile phone and a Wi-Fi connection.
Louver Angle Memory(some units)
When turning on your unit, the louver will automatically resume its former angle.
Refrigerant Leakage Detection (some units)
The indoor unit will automatically display “EC” when it detects refrigerant leakage.
For a detailed explanation of your unit’s advanced functionality (such as TURBO mode and its self-cleaning functions), refer to the
Remote Control Manual.
NOTE ON ILLUSTRATIONS
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.
Setting Angle of Air Flow
Setting vertical angle of air flow
While the unit is on, use the SWING /DIRECT button to set the direction (vertical angle) of airflow.
1. Press the SWING /DIRECT button once to activate the louver. Each time you press the button, it will adjust the louver by 6°. Press the button until the direction you prefer is reached.
2. To make the louver swing up and down continuously, press and hold the SWING/ DIRECT button for 3 seconds. Press it again to stop the automatic function.
Setting horizontal angle of air flow
Range
Caution: Do not keep louver at too vertical an angle for long periods of time. This can cause water condensation to drip on your furnishings.
The horizontal angle of the airflow must be set manually. Grip the deflector rod (See Fig.2.3) and manually adjust it to your preferred direction. For some units, the horizontal angle of the airflow can be set by remote control. please refer to the Remote Control Manual.
NOTE ON LOUVER ANGLES
When using COOL or DRY mode, do not set louver at too vertical an angle for long periods of time. This can cause water to condense on the louver blade, which will drop on your floor or furnishings. (See Fig. 2.2 )
When using COOL or HEAT mode, setting the louver at too vertical an angle can reduce the performance of the unit due to restricted air flow.
Do not move louver by hand. This will cause the louver to become out of sync. If this occurs, turn off the unit and unplug it for a few seconds, then restart the unit. This will reset the louver.
Fig. 2.2
CAUTION
Do not put your fingers in or near the blower and suction side of the unit. The high-speed fan inside the unit may cause injury.
Deflector rod
The louver can be taken down by releasing the lock block.
Fig. 2.3
Sleep Operation
The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control.
Press the SLEEP button when you are ready to go to sleep. When in COOL mode, the unit will increase the temperature by 1°C (2°F) after 1 hour, and will increase an additional 1°C (2°F) after another hour. When in HEAT mode, the unit will decrease the temperature by 1°C (2°F) after 1 hour, and will decrease an additional 1°C (2°F) after another hour.
It will hold the new temperature for 7 hours, then the unit will turn off automatically.
Note: The SLEEP function is not available in FAN or DRY mode.
SLEEP Operation
Set
temperature
+/- 1 C/2 F
1hr
Saving energy during sleep
+/- 1 C/2 F
Fig. 3.1
1hr
7 hours
timer off
Manual Operation (Without Remote)
How to operate your unit without the remote control
In the event that your remote control fails to work, your unit can be operated manually with the MANUAL CONTROL the indoor unit. Note that manual operation is not a long-term solution, and that operating the unit with your remote control is strongly recommended.
BEFORE MANUAL OPERATION
Unit must be turned off before manual operation.
To operate your unit manually:
1. Locate the MANUAL CONTROL button on the right-hand side panel of the unit.
2. Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
3. Press the MANUAL CONTROL again to activate FORCED COOLING mode.
4. Press the MANUAL CONTROL button a third time to turn the unit off.
button located on
CAUTION
The manual button is intended for testing purposes and emergency operation only. Please do not use this function unless the remote is lost and it is absolutely necessary. To restore regular operation, use the remote control to activate the unit.
Manual control button
Care and Maintenance
Cleaning Your Indoor Unit
BEFORE CLEANING OR MAINTENANCE
ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY BEFORE CLEANING OR MAINTENANCE.
CAUTION
Only use a soft, dry cloth to wipe the unit clean. If the unit is especially dirty, you can use a cloth soaked in warm water to wipe it clean.
Do not use chemicals or chemically treated cloths to clean the unit
Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. They can cause the plastic surface to crack or deform.
Do not use water hotter than 40°C (104°F) to clean the front panel. This can cause the panel to deform or become discolored.
Filter Tab
Cleaning Your Air Filter
A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health. Make sure to clean the filter once every two weeks.
1. Lift the front panel of the indoor unit. The air filter is under the top air inlet grill.
2. Grip the tab on the end of the filter, lift it up,then pull it towards yourself.
3. Now pull the filter out.
4. Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
5. Rinse the filter with fresh water, then shake off excess water.
6. Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
7. Close the front panel of the indoor unit.
Fig. 5.1
CAUTION
Do not touch air freshening (Plasma) filter for at least 10 minutes after turning off the unit.
CAUTION
Before changing the filter or cleaning, turn off the unit and disconnect its power supply.
When removing filter, do not touch metal parts in the unit. The sharp metal edges can cut you.
Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock.
Do not expose filter to direct sunlight when drying. This can shrink the filter.
Air Filter Reminders (Optional)
Air Filter Cleaning Reminder
After 240 hours of use, the display window on the indoor unit will flash “CL.” This is a reminder to clean your filter. After 15 seconds, the unit will revert to its previous display.
Maintenance – Long Periods of Non-Use
If you plan not to use your air conditioner for an extended period of time, do the following:
Clean all filters
Turn off the unit and disconnect the power
Remove batteries
Turn on FAN function until
unit dries out completely
from remote control
To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. If you don’t reset the reminder, the “CL” indicator will flash again when you restart the unit.
Air Filter Replacement Reminder
After 2,880 hours of use, the display window on the indoor unit will flash “nF.” This is a reminder to replace your filter. After 15 seconds, the unit will revert to its previous display.
To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. If you don’t reset the reminder, the “nF” indicator will flash again when you restart the unit.
CAUTION
Any maintenance and cleaning of outdoor unit should be performed by an authorized dealer or licensed service provider.
Any unit repairs should be performed by authorized dealer or licensed servic e
provider.
Maintenance – Pre-Season Inspection
After long periods of non-use, or before periods of frequent use, do the following:
Check for damaged wires Clean all filters
Check for leaks Replace batteries
Make sure nothing is blocking all air inlets and outlets
Troubleshooting
S AFETY P RECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately!
The power cord is damaged or abnormally warm
You smell a burning odor
The unit emits loud or abnormal sounds
A power fuse blows or the circuit breaker frequently trips
Water or other objects fall into or out of the unit
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AUTHORIZED SERVICE PROVIDER IMMEDIATELY!
Common Issues
The following problems are not a malfunction and in most situations will not require repairs.
Issue Possible Causes
Unit does not turn on when pressing ON/OFF button
The unit changes from COOL/HEAT mode to FAN mode
The indoor unit emits white mist
Both the indoor and outdoor units emit white mist
The Unit has a 3-minute protection feature that prevents the unit from overloading. The unit cannot be restarted within three minutes of being turned off.
The unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previously selected mode again.
The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctuates again.
In humid regions, a large temperature difference between the room’s air and the conditioned air can cause white mist.
When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.
Issue Possible Causes
A rushing air sound may occur when the louver resets its position.
The indoor unit makes noises
A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts.
Low hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
Both the indoor unit and outdoor unit make noises
The outdoor unit makes noises
Dust is emitted from either the indoor or outdoor unit
The unit emits a bad odor
The fan of the outdoor unit does not operate
Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.
The unit will make different sounds based on its current operating mode.
The unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by covering the unit during long periods of inactivity.
The unit may absorb odors from the environment (such as furniture, cooking, cigarettes, etc.) which will be emitted during operations.
The unit’s filters have become moldy and should be cleaned.
During operation, the fan speed is controlled to optimize product operation.
Troubleshooting
Operation is erratic, unpredictable, or unit is unresponsive
Interference from cell phone towers and remote boosters may cause the unit to malfunction.
In this case, try the following:
Disconnect the power, then reconnect.
Press ON/OFF button on remote control to restart operation.
NOTE: If problem persists, contact a local dealer or your nearest customer service center. Provide them with a detailed description of the unit malfunction as well as your model number.
Troubleshooting
When troubles occur, please check the following points before contacting a repair company.
Problem Possible Causes Solution
Temperature setting may be higher than ambient room temperature
The heat exchanger on the indoor or outdoor unit is dirty
Lower the temperature setting
Clean the affected heat exchanger
Poor Cooling Performance
The air filter is dirty
The air inlet or outlet of either unit is blocked
Doors and windows are open
Excessive heat is generated by sunlight
Too many sources of heat in the room (people, computers, electronics, etc.)
Low refrigerant due to leak or long-term use
SILENCE function is activated
Remove the filter and clean it according to instructions
Turn the unit off, remove the obstruction and turn it back on
Make sure that all doors and windows are closed while operating the unit
Close windows and curtains during periods of high heat or bright sunshine
Reduce amount of heat sources
Check for leaks, re-seal if necessary and top off refrigerant
SILENCE function can lower product performance by reducing operating frequency. Turn off SILENCE function.
Troubleshooting
Problem Possible Causes Solution
The unit is not working
The unit starts and stops frequently
Power failure
The power is turned off Turn on the power
The fuse is burned out Replace the fuse
Remote control batteries are dead
The Unit’s 3-minute protection has been activated
Timer is activated Turn timer off
There’s too much or too little refrigerant in the system
Incompressible gas or moisture has entered the system.
The compressor is broken Replace the compressor
The voltage is too high or too low
Wait for the power to be restored
Replace batteries
Wait three minutes after restarting the unit
Check for leaks and recharge the system with refrigerant.
Evacuate and recharge the system with refrigerant
Install a manostat to regulate the voltage
The outdoor temperature is lower than 7°C (44.5°F)
Poor heating performance
Indicator lamps continue flashing
Tr
Error code appears in the window display of indoor unit:
E0, E1, E2…
P1, P2, P3…
F1, F2, F3…
Cold air is entering through doors and windows
Low refrigerant due to leak or long-term use
The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn the unit on.
If the problem persists, disconnect the power and contact your nearest customer service center.
Use auxiliary heating device
Make sure that all doors and windows are closed during use
Check for leaks, re-seal if necessary and top off refrigerant
NOTE: If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact an authorized service center.
NOTE CONCERNING PROTECTION OF ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be taken to a collection station for the recycling of electrical and electronic devices. The symbol on the product, the
operating instructions or the packaging indicate such disposal procedures. The materials are recyclable in accordance with their respective symbols. By means of re-use, material recycling or any other form of recycling old appliances you are making an important contribution to the protection of our environment. Please ask your local council where your nearest disposal station is located.
INFORMATION CONCERNING USED REFRIGERANT MEDIUM
This unit is containing fluorinated gases included in the Kyoto protocol. The maintanance and the liquidation must be carried out by qualified personel. Type of refrigerant: R410A The composition of the cooling medium R410A: (50% HFC-32, 50% HFC-125) The quantity of the refrigerant: please see the unit label. The value GWP: 2088 GWP = Global Warming Potential
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112
PRODUCER
Producer: SINCLAIR CORPORATION Ltd., 1-4 Argyll St., London W1F 7LD, UK, www.sinclair-eu.com This product was manufactured in China (Made in China).
REPRESENTATIVE, TECHNICAL SUPPORT
NEPA spol. s r.o. PurkyĖova 45 612 00 Brno Czech Republic
Tel.: +420 541 590 140 Fax: +420 541 590 124 www.nepa.cz klimatizace@nepa.cz
Loading...