Sinclair ASH-13AIA PT, ASH-18AIA PT User Manual

Page 1
ARCTIC SERIES indoor unit
ASH-13AIA PT, ASH-18AIA PT
USER'S MANUAL
Page 2
„Original instruction“
Page 3
Specialties note
Matching of remote controller
Please done the following operation within 2m from the unit. Matching is not needed anymore once it is done.
During matching, please keep the remote controller and air conditioner under standby status. When the signal of remote controller can’t be received, please match the remote controller with the unit again.
This model adopts RF remote control. The remote controller shall be matched with the air conditioner before operation, otherwise the remote control will be invalid. Before operation, please read the instructions in this page carefully and then do the corresponding matching operation.
Note
When the unit is under standby status, please get close to the air conditioner within 2m and then hold on pressing button for 3s. The remote controller and air conditioner will enter matching automatically. If matching is done, the unit will give out three sounds; if matching is failed, please get closer to the unit and arrange matching again.
Humidify/Health
3
Page 4
Precautions
WARNING
Do not connect air conditioner to multi-purpose socket.
This appliance can be used by children aged from 8
Operation and Maintenance
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
Otherwise, it may cause fire hazard.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Do not wash the air conditioner with water to avoid electric shock.
After removing the filter, do not touch fins to avoid injury. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
.
5
Page 5
Do not block air outlet or air inlet. It may cause malfunction.
remote controller may be broken.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
contact the dealer or qualified professionals for service.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
outlet. It may cause personal injury or damage.
Precautions
WARNING
conditioner and disconnect power immediately, and then
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
Do not spill water on the remote controller, otherwise the
electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not repair air conditioner by yourself. It may cause
objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy
When below phenomenon occurs, please turn off air
Do not extend fingers or objects into air inlet or air
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury
or damage.
6
Page 6
Do install the circuit break. If not, it may cause malfunction.
of at least 3mm in all poles should be connected in fixed wiring.
magnet buckle
and heating buckle function, it can protect
the circuit-short and
overload.
power supply circuit and circuit break.
Precautions
WARNING
note
the following table.Air switch should be included
Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
An all-pole disconnection switch having a contact separation
Must follow the electric safety regulations when installing the unit.
grounding wire of power socket.
Properly connect the live wire, neutral wire and
any work related to electricity and safety.
Be sure to cut off the power supply before proceeding
Including an circuit break with suitable capacity, please
Air Conditioner should be properly grounded. Incorrect
Don't use unqualified power cord.
grounding may cause electric shock.
According to the local safety regulations, use qualified
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Attachment
7
Page 7
Installation must be performed in accordance with the
persons in order to avoid a hazard.
must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The appliance must be positioned so that the plug is accessible.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
All wires of indoor unit and outdoor unit should be connected by a professional.
national wiring regulations.
requirement of NEC and CEC by authorized personnel only.
Precautions
WARNING
wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The air conditioner is the first class electric appliance. It
keep the interconnection cable away from the copper tube.
The temperature of refrigerant circuit will be high, please
the manufacturer, its service agent or similarly qualified
If the supply cord is damaged, it must be replaced by
The yellow-green wire in air conditioner is grounding
The appliance shall be installed in accordance with
Do not put through the power before finishing installation.
8
Page 8
The indoor unit should be installed close to the wall.
reachable after finishing installation.
far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
Precautions
WARNING
place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
If you need to relocate the air conditioner to another
must be installed in the line.
For the air conditioner without plug, an circuit break
Select a location which is out of reach for children and
For the air conditioner with plug, the plug should be
Working temperature range
NOTICE:
Indoor side DB/WB(°C) Outdoor side DB/WB(°C)
Maximum cooling 32/23 54/26
Maximum heating 27/- 24/18
The operating temperature range (outdoor temperature) for cooling is -18~54; The operating temperature range (outdoor temperature) for heating is -30°C~24°C
is -15~24
Heating temperature range for the model with electric heating belt
for chassis is -20~24 .
9
Page 9
Parts name
Indoor Unit
air inlet
panel
filter
power wire
horizontal louver
remote controller
air outlet
tem.display
power
display
NOTICE:
Actual product may be different from above graphics, please refer to actual products.
10
Page 10
Buttons on remote controller
Introduction for icons on display screen
3
2
5 6
10 11
12 15
9
17
14
13
16
8
7
4
1
1 ON/OFF button 2
+/- button
3
Cool button
4
Heat button
6 I FEEL button 7
up down swing button
9
Left right swing button
14
X-fan button
15
Sleep button
Light button
16 17
WIFI button
11
Clock button
12 13
Humidity button/Health button
Air button
10
T-ON/T-OFF button
8
Mode button
5
Fan button
battery power
Send signal
8℃ heating function
I feel function
Set fan speed
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
humidity functions Temp.display type Healthy mode
Set temperature
INTELLIGENT
HOUR ON OFF
WIFI
Up & down swing Left & right swing
child lock Replacing air
Quiet mode
Auto quiet mode
X-FAN function
Turbo fan speed
Sleep mode
Set time
11
Page 11
Pressing this button can set fan speed circularly as: low(
low med
ium( ),) ,
medium ( ),medium high( ),high( ),super( ),auto(AUTO),quiet( ).
Auto
Note:
● Under AUTO speed, air conditioner will select proper fan speed automatically according to ambient temperature.
● Automatically operate slient speed when starting sleep fuction.
● Turbo function is not available under dry and auto mode.
The unit operates at low speed under dry and auto dry mode. The speed can't
be adjusted.
FAN button
5
● When setting TIMER , press "+" or " - " button to adjust time.
+/- button
2
● Press "+" or " - " button once increase or decrease set temperature 0.5
℃.
Holding "+" or " - " button, 2s later, set temperature on remote controller will
change quickly.On releasing button after setting is finished, temperature indica­ tor on indoor unit will change accordingly. (Temperature can’t be adjusted under auto mode)
Introduction for buttons on remote controller
Note:
After putting through the power, the air conditioner will give out a sound. Operation indictor " " is ON (red indicator). After that, you can operate the air conditioner by using remote controller.
Under on status, pressing the button on the remote controller, the signal icon " "
on the display of remote controller will blink once and the air conditioner will give
out a “de” sound, which means the signal has been sent to the air conditioner.
ON/OFF button
1
Press this button can turn on or turn off the air conditioner. After turning on the air conditioner, operation indicator " "on indoor unit’s display is ON (green indicator. The colour is different for different models), and indoor unit will give out a sound.
Cool button
3
● Press this button, unit will operate in cool mode.
● Press this button, unit will operate in heat mode.
Heat button
4
12
Page 12
Introduction for buttons on remote controller
7
button
no display
(stops at current position)
between simple swing mode and fixed swing mode. During switching time, “ ” icon on remote controller will flash twice.
● Under simple swing mode, press this button can turn on (display " " icon ) or turn off ( not display " " icon) left&right swing function.
● Under fixed-angle swing mode, press this button and the left and right swing status
● Under OFF status, press "+" button and " " button simultaneously can switch
will change in the sequence as below:
I FEEL button
6
Press this button to start I FEEL function and " " will be displayed on the remote controller. After this function is set, the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature. Press this button again to close I FEEL function and " " will disappear.
● Please put the remote controller near user when this function is set. Do not put the remote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature.
MODE button
8
Press this button to select your required operation mode.
AUTO COOL FANDRY HEAT
13
Page 13
Introduction for buttons on remote controller
● When selecting auto mode, air conditioner will operate automatically according to ambient temperature. Set temperature can’t be adjusted and will not be displayed as well. Press "FAN" button can adjust fan speed. Press " " / " " button can adjust fan blowing angle.
● After selecting cool mode, air conditioner will operate under cool mode. Press "+" or "-" button to adjust set temperature. Press "FAN" button to adjust
fan speed.Press " " / " " button to adjust
fan blowing angle.
● When selecting dry mode, the air conditioner operates at low speed under dry mode. Under dry mode, fan speed can’t be adjusted. Press " " / " " button to
adjust fan blowing angle.
● When selecting fan mode, the air conditioner will only blow fan,Press "FAN" button to adjust fan speed. Press " " / " " button to adjust fan blowing angle.
● When selecting heating mode, the air conditioner operates under heat mode. Press "+" or "- " button to adjust set temperature. Press "FAN" button to adjust fan speed. Press " " / " " button to adjust fan blowing angle. (Cooling only
unit won’t receive heating mode signal. If setting heat mode with remote controller,
press ON/OFF button can’t start up the unit).
Note:
● For preventing cold air, after starting up heating mode, indoor unit will delay 1~5
minutes to blow air (actual delay time is depend on indoor ambient temperature).
● Set temperature range from remote controller: 16~30℃(61-86°F);
no display
9
(horizontal louvers stops at current position)
button
● Under simple swing mode, press this button can turn on ( display " " icon) or turn off ( not display " " icon) up&down swing function.
● Under OFF status, press "+" button and " " button simultan
● Under fixed swing mode, press this button and up and down swing status will
eously can switch
change in the sequence as below:
between simple swing mode and fixed swing mode. During switching time, “ ” icon on remote controller will flash twice.
14
Page 14
T-ON button “T-ON” button can set the time for timer on. After pressing this button, " " icon
disappears and the word “ON" on remote controller blinks. Press “+” or “-”button to adjust T-ON setting. After each pressing “+” or “-”button, T-ON setting will increase or decrease 1min. Hold “+” or “-”button, 2s later, the time will change
will stop blinking. " " icon resumes displaying.Cancel TIMER ON: Under the
quickly until reaching your required time. Press“T-ON”to confirm it. The word “ON”
until reaching your required time. Press“T-OFF”to confirm it. The word “ON”will
condition that T-ON is started up, press “T-ON” button to cancel it.
T-OFF button “T-OFF” button can set the time for timer off. After pressing this button, " " icon
disappears and the word "OFF" on remote controller blinks. Press "+" or "-" button to adjust T-OFF setting. After each pressing "+" or "-" button, T-OFF setting will increase or decrease 1min. Hold "+" or "-" button, 2s later, the time will change
"OFF" will stop blinking. " " icon resumes displaying. Cancel T-OFF.Under the condition that T-OFF is started up, press “T-OFF” button to cancel it.
Note:
● Under on and off status, you can set T-OFF or T-ON simultaneously.
● Before setting T-ON or T-OFF, please adjust the clock time.
After starting up T-ON or T-OFF, set the constant circulating valid. After that,
air conditioner will be turned on or turned off according to setting time. ON/OFF button has no effect on setting. If you don’t need this function, please use remote controller to cancel it.
10
T-ON/T-OFF button
Introduction for buttons on remote controller
Press this button to set clock time. " " icon on remote controller will blink. Press "+" or "-" button within 5s to set clock time. Each pressing of "+" or "-" button, clock time will increase or decrease 1 minute. Hold "+" or "-" button, 2s later, time will change quickly. Release this button when reaching your required time. Press “CLOCK”button to confirm the time. " " icon stops blinking.
Note:
● Clock time adopts 24-hour mode.
The interval between two operations can’t exceeds 5s. Otherwise, remote
controller will quit setting status. Operation for TIMER ON/TIMER OFF is
the same.
11
CLOCK button
15
Page 15
SLEEP button
16
Pressing this button can select Sleep 1, Sleep 2,Sleep 3, Sleep 4 or cancel Sleep circularly as below:
cancel
Introduction for buttons on remote controller
12
Humdity/health button
Press this button to select your required operation mode.
Note:there is no this function for this unit. If press this button,the main unit will click,
but it also runs under original status.
INTELLIGENT INTELLIGENT
Press this button to select your required operation mode.
Note:there is no this function for this unit. If press this button,the main unit will click,
but it also runs under original status.
cancel
cancel
X-FAN button
13
Pressing this button in COOL or DRY mode, the icon " " is displayed and the indoor fan will continue operation for 2 minutes in order to dry the indoor unit even though you have turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode. This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.
● Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for about 2 min. at low speed. In this period, press X-FAN button to stop indoor fan directly.
● Having set X-FAN function off: After turning off the unit by pressing ON/OFF button, the complete unit will be off directly.
14
Air button
LIGHT button
15
Pressing this button to turn off display light on indoor unit. Press this button again to turn on display light.
16
Page 16
temperature curves.
In Sleep 1 and Sleep 2, the air conditioner will run according to a group of presetting
Sleep 3 - the sleep curve setting under DIY Sleep mode: (1) Under Sleep 3 mode, long press "AIR" button, the remote controller will enter the setting of personalized sleep. In this case, the timer zone of remote controller will display "1 hr" and the set temperature zone "88" will display the corresponding temperature of the last set sleep curve and blink (The first entering will display according to the initial curve setting value of manufacturer);
Sleep 3 - the sleep curve inquiry under DIY Sleep mode: User can inquire the set sleep curve according to the setting method of sleep curve. Enter the setting of personalized sleep but do not change the temperature. Then
Sleep 4 is Siesta mode. The set temperature will change automatically according to
Sleep function will be disabled if the air condition is restarted after power failure;
Sleep function can not be set in AUTO mode.
when sleep function is turned on, quite fan speed will be also turned on.
the features of siesta.
press "AIR" button to confirm the setting. Note: In the above setting or inquiry procedure, if there is no button pressing within 10s, remote controller will automatically exit the sleep curve setting and resume the
original display. If ON/OFF, MODE, TIMER, HUMIDIFY, SLEEP, COOLING or
HEATING button is pressed during the setting or inquiry procedure, remote controller
will also exit the sleep curve setting.
(2) Press "+" and "-" button to adjust the corresponding temperature. After adjusting, press "AIR" button to confirm it;
(3) At this time, the timer time on the remote controller will increase automatically by 1hr (that is "2 hr" or "3 hr" … or "8 hr"). The set temperature zone "88" will display the corresponding temperature of the last set sleep curve and blink;
(4)Repeat step(2) and step (3) until 8-hour temperature setting is finished, then the sleep curve is set successfully. After that, remote controller will resume displaying the original timer time and temperature zone will resume displaying the original set temperature.
Introduction for buttons on remote controller
Wifi button
17
Press this button 3s can set wifi function on or OFF.
At OFF status,press mode button and wifi button,can reset wifi mode parameter. and open wifi function.
17
Page 17
Function introduction for combination buttons
About X-FAN function
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.
indoor fan will continue running for about 2 min. at low speed. In this period, press X-FAN button to stop indoor fan directly.
1. Having set X-FAN function on: After turning off the unit by pressing ON/OFF button
the complete unit will be off directly.
2. Having set X-FAN function off: After turning off the unit by pressing ON/OFF button,
About AUTO RUN
When AUTO RUN mode is selected, the setting temperature will not be displayed on the LCD, the unit will be in accordance with the room temp. automatically to select the suitable running method and to make ambient comfortable.
About lock
Press + and - buttons simultaneously to lock or unlock the keyboard. If the remote co­ntroller is locked, the icon will be displayed on it, in which case, press any button, the mark will flicker for three times. If the keyboard is unlocked, the mark will disappear.
About switch between Fahrenheit and Centigrade
Under status of unit off, press MODE and - buttons simultaneously to switch and .
18
Page 18
1.
After putting through the power, press "ON/OFF" button on remote controller to
turn on the air conditioner.
2.
HEAT.
3.
Press "+" or " - " button to set your required temperature. (Temperature can’t
be adjusted under auto mode).
4.
Press "FAN" button to set your required fan speed: auto, low, medium and high
speed.
Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN,
5.
Press "SWING" button to select fan blowing angle.
Operation guide
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
signal sender battery
Cover of battery box
remove
reinstall
NOTICE
● During operation, point the remote control signal sender at the receiving window on indoor unit.
The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles between them.
Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone; remote controller should be close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please replace batteries.
Battery level will be displayed on the remote
replace the batteries, otherwise, remote controller can’t operate normally.
controller.When " " is flickering, please
battery level
19
Page 19
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below:
air conditioner. When the air conditioner is turned on, it will operate under auto mode.
aux. button
panel
Display panel
Clean and maintenance
Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.
NOTICE:
● Do not remove the panel when cleaning it.
WARNING
Warning:Use insulated object to press the auto button
20
Page 20
Clean and maintenance
1
2
3
4
Open panel
● Use dust catcher or water to Open the panel into a certain angle(less than 60°, do not open the panel too forcibly) along the arrow direction from the two sides of panel.
the water (below 45℃) to clean it, and then put it in a shady and cool place to dry.
panel cover tightly.
operation environment, clean frequency can be increased.
WARNING
21
Page 21
Clean and maintenance
Notice for recovery
1. Many packing materials are recyclable materials. Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or consultant service center for the correct disposal method.
1. Check whether air inlets and air outlets are blocked.
2. Check whether air switch, plug and socket are in good condition.
4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
1. Disconnect power supply.
3. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
NOTICE: Checking before use-season
NOTICE: Checking after use-season
22
Page 22
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualied professionals.
Phenomenon Check items Solution
Indoor unit can’t receive remote controller’s signal or remote controller has no action.
● Whether it's interfered severely
(such as static electricity,stable voltage)?
● Whether remote controller is
within the signal receiving range?
● Whether there are obstacles?
● Whether remote controller is
pointing at the receiving window?
● Is sensitivity of remote contro­ ller low; fuzzy display and no
display?
● No display when operating
remote controller?
● Fluorescent lamp in room?
● Pull out the plug. Reinsert
the plug after about 3min, and then turn on the unit again.
● Signal receiving range is 8m.
● Remove obstacles.
Select proper angle and point the remote controller at the re­ ceiving window on indoor unit.
● Check the batteries. If the
power of batteries is too low, please replace them.
● Take the remote controller
close to indoor unit.
● Turn off the uoresent lamp
and then try it again.
● Check whether remote cont-
roller appears to be damaged. If yes, replace it.
No air
emitted from indoor unit
● Air inlet or air outlet of indoor
unit is blocked?
● Eliminate obstacles.
● Under heating mode, indoor
temperature is reached to set temperature?
● After reaching to set temper-
ature, indoor unit will stop bl­ owing out air.
● Heating mode is turned on just
now?
● In order to prevent blowing
out cold air, indoor unit will be started after delaying for sev­ eral minutes, which is a nor­ mal phenomenon.
23
Page 23
Malfunction analysis
● Power failure?
● Is plug loose?
● Air switch trips off or fuse is
burnt out?
● Wiring has malfunction?
● Unit has restarted immediately
after stopping operation?
● Whether the function setting
for remote controller is correct?
● Reset the function.
● Wait for 3min, and then turn
on the unit again.
● Ask professional to replace it.
● Ask professional to replace
air switch or fuse.
● Reinsert the plug.
● Wait until power recovery.
Air condit­ioner can’t operate
Mist is em­itted from indoor unit’s air outlet
● Indoor temperature and hum-
idity is high?
● Because indoor air is cooled
rapidly. After a while, indoor temperature and humidity will be decrease and mist will disappear.
Phenomenon
Check items Solution
Set temper­ature can’t be adjusted
● Unit is operating under auto
mode?
● Temperature can’t be adju-
sted under auto mode. Please switch the operation mode if you need to adjust temperature.
● Your required temperature
exceeds the set temperature range?
● Set temperature range:
16℃~30℃.
Cooling (heating) effect is not good.
● Voltage is too low?
● Wait until the voltage
resumes normal.
● Filter is dirty? ● Clean the lter.
● Set temperature is in proper
range?
● Adjust temperature to proper
range.
● Door and window are open? ● Close door and window.
24
Page 24
Phenomenon Check items Solution
Odours are emitted
● Whether there’s odour source,
such as furniture and cigarette, etc.
● Eliminate the odour source.
● Clean the lter.
Air conditioner operates nor­mally suddenly
● Whether there’s interference,
such as thunder, wireless devices, etc.
● Disconnect power, put back
power, and then turn on the unit again.
Outdoor unit has vapor
● Heating mode is turned on?
● During defrosting under he-
ating mode, it may generate vapor, which is a normal phenomenon.
“Wat er
owing”
noise
● Air conditioner is turned on or
turned off just now?
● The noise is the sound of refrigerant owing inside
the unit, which is a normal phenomenon.
Cracking noise
● Air conditioner is turned on or
turned off just now?
● This is the sound of friction
caused by expansion and/or contraction of panel or other parts due to the change of temperature.
Malfunction analysis
25
Page 25
Note: If there're other error codes, please contact qualified professionals for service.
WARNING
Error code
E5
E8
E6
U8
H6
C5
F1 F2
Troubleshooting
It can be eliminated after restarting the unit. If not , please
It can be eliminated after restarting the unit. If not , please
It can be eliminated after restarting the unit. If not,please
It can be eliminated after restarting the unit. If not,please
It can be eliminated after restarting the unit. If not,please
■ When below phenomenon occurs, please turn off air conditioner and discon-
for service.
● Power cord is overheating or damaged.
There’s abnormal sound during operation.
Air switch trips off frequently.
Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
Error Code
● When air conditioner status is abnormal, temperature indictor on indoor unit will
ation of error code.
Malfunction analysis
26
Page 26
Installation dimension diagram
At least 250cm
At least 15cm
At least 300cm
Space to the ceiling
Space to the obstruction
At least 15cm
At least 15cm
Space to the wall
Space to the wall
27
Page 27
1. There should be no obstruction near air inlet and air outlet.
2. Select a location where the condensat­ ion water can be dispersed easily and won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5.
The location should be able to withstand the weight of indoor unit and won't incr­ ease noise and vibration.
6.
The appliance must be installed 2.5m
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from
Tools for installation
Selection of installation location
1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
● Please contact the local agent for installation.
Basic requirement
Indoor unit
Installing the unit in the following pla­ces maycause malfunction. If it is un­avoidable, please consult the local dealer:
1.The place with strong heat sources, ,
or volatile objects spread in the air.
2.The place with high-frequency
devices (such as welding machine, medical equipment).
3.The place near coast area.
4.
The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circums-
tances.
7.The appliance shall not be installed
in the laundry.
28
Page 28
Requirements for electric connection
Safety precaution
Grounding requirement
1. Must follow the electric safety regulations when installing the unit.
air switch.
3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnec­ tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in For models with a power plug, make
sure the plug is within reach after installation
29
Page 29
Installation of indoor unit
Step one: choosing installation location
Step two: install wall-mounting frame
rm it with the client.
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
1. Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame, shown as below.
Step three: open piping hole
2. Open a piping hole with the diameter of Φ55 on the selected outlet pipe
position.In order to drain smoothly, slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5-10°.
13K:
18K:
Left
Wall
Φ55mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55mm
Rear piping hole
Left
Wall
Φ55mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55mm
Rear piping hole
30
Page 30
1. Aim the pipe joint at the corresponding
bellmouth.
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench.
2. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case.
cut off the hole
left
right
1. The pipe can be led out in the
direction of right, rear right, left or rear left.
left
rear left
right
rear right
Step four: outlet pipe
Installation of indoor unit
union nutpipe joint
pipe
Note:
● Pay attention to dust prevention and take relevant safety measures when
opening the hole.
The plastic expansion particles are not provided and should be bought
locally.
Indoor
5-10
outdoor
Φ55
31
Page 31
4. Wrap the indoor pipe and joint of con-
nection pipe with insulating pipe, and then wrap it with tape.
Step six: install drain hose
Installation of indoor unit
torque wrench
open-end wrench
indoor pipe
pipe
union nut
Hex nut diameter Tightening torque (N.m)
Φ 6
Φ 9.52
Φ 12 Φ 16 Φ 19
30~40 45~55
60~65 70~75
15~20
insulating pipe
1. Connect the drain hose to the outlet pipe of
indoor unit.
2. Bind the joint with tape.
outlet
pipe
drain hose
drain hose
tape
outlet pipe
drain hose
insulating pipe
Note:
● Add insulating pipe in the indoor
drain hose in order to prevent condensation.
● The plastic expansion particles are
not provided.
1. Open the panel, remove the screw
on the wiring cover and then take down the cover.
wiring cover
screw
pane
Step seven: connect wire of indoor unit
32
Page 32
4.Put wiring cover back and then tighten the screw.
5.Close the panel.
Installation of indoor unit
Note:
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an circuit break must be installed in the line.
The circuit break should be all-pole parting and the contact parting distance
should be more than 3mm.
3. Remove the wire clip; connect the power connection wire to the wiring terminal
with wire clip.After finishing wiring of 18K unit, clamp the grounding wire (yellow-
green wire) into the wire-crossing groove as shown in the following figure, in order to avoid pressing the wire when closing the electric box cover.
power connection wire
cable-cross hole
2. Make the power connection wire go through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
2 3N(1)
Outdoor unit connection
13K:
blue black brown
yellow­green
2 3N(1)
Outdoor unit connection
18K:
blue black brown
yellow­green
33
Page 33
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor unit
gas pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band
2. Reserve a certain length of drain
hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.
3. Bind them evenly.
4. The liquid pipe and gas pipe should be bound separately at the end.
Note:
● The power cord and control wire can't be crossed or winding.
● The drain hose should be bound
at the bottom.
drain hose
band
connection pipe
indoor power cord
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
upper hook
lower hook of
5.Check if the indoor unit is installed firmly and closed to the wall.
wall-mounting frame
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
indoor
outdoor
wall pipe
sealing gum
34
Page 34
Leakage detection
6. Tighten the screw caps of valves and refrigerant charging vent.
7. Reinstall the handle.
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection. Apply soap water at the suspected position and keep the soap water for more than 3min. If there are air bubbles coming out of this position, there's a leakage.
Vacuum pumping
1. Remove the valve caps on
the liquid valve and gas valve and the nut of refri­ gerant charging vent.
2. Connect the charging hose
of piezometer to the refri-
gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump.
3. Open the piezometer com-
pletely and operate for 10-15min to check if the
pressure of piezometer re-
mains in -0.1MPa.
4. Close the vacuum pump
and maintain this status for 1-2min to check if the pres-
sure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
Use vacuum pump
liquid valve
gas valve
refrigerant charging vent
nut of refrigerant charging vent
vacuum pump
piezometer
valve cap
Lo Hi
inner hexagon spanner
open
close
35
Page 35
Check after installation
Test operation
● Check according to the following requirement after nishing installation.
Items to be checked Possible malfunction
Has the unit been installed rmly? The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test?
It may cause insufcient cooling
(heating) capacity.
Is heat insulation of pipeline sufcient?
It may cause condensation and water dripping.
Is water drained well?
It may cause condensation and water dripping.
Is the voltage of power supply accord­ing to the voltage marked on the nameplate?
It may cause malfunction or damaging the parts.
Is electric wiring and pipeline installed correctly?
It may cause malfunction or damaging the parts.
Is the unit grounded securely? It may cause electric leakage.
Does the power cord follow the speci­cation?
It may cause malfunction or damaging the parts.
Is there any obstruction in the air inlet and outlet?
It may cause insufcient cooling
(heating) capacity.
The dust and sundries caused during installation are removed?
It may cause malfunction or damaging the parts.
The gas valve and liquid valve of connection pipe are open completely?
It may cause insufcient cooling
(heating) capacity.
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.
36
Page 36
Conguration of connection pipe
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe): Additional refrigerant charging amount = prolonged length of liquid pipe × additional refrigerant charging amount per meter
● When the length of connection pipe is above 5m, add refrigerant according to
the prolonged length of liquid pipe. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See the following sheet.
Cooling capacity
Cooling capacity
5000Btu/h
(1465W)
24000Btu/h
(7032W)
7000Btu/h
(2051W)
28000Btu/h
(8204W)
9000Btu/h
(2637W)
36000Btu/h
(10548W)
12000Btu/h
(3516W)
42000Btu/h
(12306W)
18000Btu/h
(5274W)
48000Btu/h
(14064W)
Max height difference
Max height difference
Max length of connec­tion pipe
Max length of connec­tion pipe
15 255 10
15 305 10
15 305 20
20 3010 20
25 3010 20
2.Min. length of connection pipe is 3m.
3.Max. length of connection pipe and max. high difference.
37
Page 37
Additional refrigerant charging amount for R410A
Diameter of connection pipe
Liquid pipe(mm) Gas pipe(mm)
Φ6
Φ6 or Φ9.52
Φ12
Φ16
Φ19
Φ22.2
Φ9.52 or Φ12
Φ16 or Φ19
Φ19 or Φ22.2
Φ25.4 or Φ31.8
_
_
Cooling only(g/m) Cooling and heating(g/m)
15
15
30
60
250 250
350
350
120
120
50
20
Outdoor unit throttle
Conguration of connection pipe
38
Page 38
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:
A: Cut the pipe
● Conrm the pipe length according to
the distance of indoor unit and outdoor unit.
● Cut the required pipe with pipe cutter.
pipe
pipe cutter
leaning uneven burr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into the pipe.
downwards
pipe
shaper
C: Put on suitable insulating pipe
D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve; install the union nut on the pipe.
union pipe
pipe
E: Expand the port
● Expand the port with expander.
Note:
● "A" is different according to the
diameter, please refer to the sheet below:
expander
hard mold
pipe
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the port again according to the steps above.
the length is equal
improper expanding
leaning
damaged
surface
crack uneven
thickness
smooth surface
Outer diameter
(mm)
A(mm)
Max Min
Φ6-6.35(1/4")
Φ9.52(3/8")
Φ12-12.7(1/2")
Φ15.8-16(5/8")
1.3 0.7
1.6 1.0
1.8 1.0
2.4 2.2
39
Page 39
40
ELECTRIC SCHEMATIC DIAGRAM
ASH-13AIA PT indoor
ASH-18AIA PT indoor
Page 40
41
RATING LABEL
Page 41
42
ENERGY LABEL
Page 42
43
NOTE CONCERNING PROTECTION OF ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be taken to a collection station for the recycling of electrical and electronic devices. The symbol on the product, the
operating instructions or the packaging indicate such disposal procedures. The materials are recyclable in accordance with their respective symbols. By means of re-use, material recycling or any other form of recycling old appliances you are making an important contribution to the protection of our environment. Please ask your local council where your nearest disposal station is located.
INFORMATION CONCERNING USED REFRIGERANT MEDIUM
This unit is containing fluorinated gases included in the Kyoto protocol. The maintanance and the liquidation must be carried out by qualified personel. Type of refrigerant: R410A The composition of the cooling medium R410A: (50% HFC-32, 50% HFC-125) The quantity of the refrigerant: please see the unit label. The value GWP: 2088 GWP = Global Warming Potential
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112