Sinclair ASH-09AIP PT, ASH-12AIP PT User Manual

Page 1
USER'S MANUAL
ASH-09AIP PT, ASH-12AIP PT
POLAR
SERIES
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Notices for use
Working temperature range
Maximum cooling
Minimum cooling
Maximum heating
Minimum heating
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28
Page 29
ASH09AIPPT ASH12AIPPT ASH18AIPPT ASH24AIPPT
cooling kW 2,65(0,453,23) 3,53(0,603,96) 5,30(1,056,50) 6,45(1,507,00)
heating kW 3,52(0,454,10) 4,10(0,605,13) 5,70(1,007,00) 7,00(1,207,80)
505050
50
MODEL
POLARSERIES
Capacity
H
z
505050
50
220240 220240 220240 220240
cooling A 6,30 6,88 11,09 11,09
heating A 6,88 7,32 11,54 11,98
cooling W 800(2001350) 1100(2201450) 1600(3602500) 1985(15007000)
Powercurrent
Powerinput
Powersupply
HzVheatingW
950(200‐1450)
1135(220‐1550)
1578(350‐2600)
1930(350‐2700)
EER 3,30 3,21 3,31 3,25
COP 3,70 3,61 3,61 3,62
Noiseindoorunit 41/38/30/24 42/39/31/25 45/40/37/32 46/42/37/32
Noiseoutdoorunit max dB(A) 51 53 54 54
W/W
dB(A)
W/W
Airflow 520 560 800 950
Dehumidifyingvolume 1,0 1,2 1,8 2,0
Refrigeranttype/charge R410a/0,7 R410a/1,0 R410a/1,3 R410a/1,4
Liquidside inch/mm ¼//6¼/6¼/6
gasside inch/mm ⅜/10 ⅜/10 ½/12 ½/12
m
3
/h
type/kg
Pipediameter
l/h
Lengthofconnectionpipe max m 15 20 25 25
Elevation/Dropheight max m 10 10 10 10
IU mm 770x283x201 770x283x201 865x305x215 1008x319x221
OU mm 710x318x550 710x318x550 955x700x396 955x700x396
IU kg 8 9 12 15
Dimension(wxhxd)
g
OU kg 28 30 52 52
cooling °C
15~46 15~46 15~48 15~48
heating °C
15~24 15~24 15~24 15~24
Thespecificationofproductsissubjecttochangebasedfurtherdevelopmentoftheunitsbytheproducerandcanbechangedwithoutprior
N
etweight
Operatingtemperaturerange
Dataarebasedonfollowingconditions:
Lengthofconnectionpipe:5m
Cooling:indoortemperature27°CDB/19°CWB,outdoortemperature35°CDB/24°CWB
notice
.
Heatingcondition:indoortemperature20°CDB/15°CWB,outdoortemperature7°CDB/6°CWB
Page 30
Page 31
63229939341
ISO9001
TUV
Sinclair Corporation Ltd, 1-4 Argyll St., London, UK
Model ASH-09AIP PT
SPLIT AIR CONDITIONER
INDOOR UNIT
Rated Voltage 220-240V~ Rated Frequency 50Hz Cooling Capacity 2650W Heating Capacity 3520W Air Flow Volum e
3
600m /h Sound Pressure Level(H) 38dB(A) Weight 8kg Manufactured Date
ISO9001
TUV
63229939342
Sinclair Corporation Ltd, 1-4 Argyll St., London, UK
Model
ASH-09AIP PT
Rated Voltage
220-240V~
(ISO 5151)
2650W
Rated Frequency
50Hz
Cooling Capacity
3520W
Climate Type
T1
Heating Capacity
800W
Weight
28kg
Cooling Power Input
950W
Isolation
I
Heating Power Input
Refrigerant
R410A
Cooling Rated Input
1420W
Refri. Charge 0.74kg Heating Rated Input
1550W
Comp. LRA 4A Sound Pressure Level
51dB(A)
3.8/1.2MPa
4MPa
Manufactured Date
Moisture Protection
I P24
Operating Pre ssure ( Discharge Side/Suction Side)
Maximum Allowable Pressure
Contains fluorinated greenhouse gases covered by the Kyoto Protocol
AIR CONDITIONER OUTDOOR UNIT
63229939343
ISO9001
TUV
Sinclair Corporation Ltd, 1-4 Argyll St., London, UK
Model
ASH-12AIP PT
SPLIT AIR CONDITIONER
INDOOR UNIT
Rated Voltage 220-240V~ Rated Frequency 50Hz Cooling Capacity 3530W Heating Capacity 4100W Air Flow Volum e
3
680m /h
Sound Pressure Level(H) 39dB(A) Weight 9kg Manufactured Date
ISO9001
TUV
63229939344
Sinclair Corporation Ltd, 1-4 Argyll St., London, UK
AIR CONDITIONER OUTDOOR UNIT
Model
ASH-12AIP PT
Rated Voltage
220-240V~
(ISO 5151)
3530W
Rated Frequency
50Hz
Cooling Capacity
4100W
Climate Type
T1
Heating Capacity
1100W
Weight
30kg
Cooling Power Input
1135W
Isolation
I
Heating Power Input
Refrigerant
R410A
Cooling Rated Input
1550W
Refri. Charge
1.0kg
Heating Rated Input
1650W
Comp. LRA
16.5A
Sound Pressure Level
53dB(A)
4.3/2.5MPa
4.3MPa
Manufactured Date
Moisture Protection
I P24
Operating Pressure ( Discharge Side/Suction Side)
Maximum Allowable Pressure
Contains fluorinated greenhouse gases covered by the Kyoto Protocol
Page 32
Energy
Manufacturer
Unit model
More efficient
Less efficient
Air cooled Water cooled
Noise
(() )
dB A re 1 pW
Further information is contained in product brochures
Norm EN 14511 Air-conditioner Energy Label Directive 2002/31/ CE
Type
Cooling only Cooling+Heating
kW
Heat output Heating performance
A: higher
G: lower
Annual Energy Consumption kWh in cooling mode
( Actual consumption will depend
on how the appliance is used and climate)
Cooling output Energy Efficiency Ratio
Full load ( the higher the better )
kW
A
A
B
C
D
E
F
G
ASH-09AIP PT
62229925972
400
2.65
3.31
3.52
A
B
CDEFG
38/51
3.7
Energy
Manufacturer
Unit model
More efficient
Less efficient
Air cooled Water cooled
Noise
(() )
dB A re 1 pW
Further information is contained in product brochures
Norm EN 14511 Air-conditioner Energy Label Directive 2002/31/ CE
Type
Cooling only Cooling+Heating
kW
Heat output Heating performance
A: higher
G: lower
Annual Energy Consumption kWh in cooling mode
( Actual consumption will depend
on how the appliance is used and climate)
Cooling output Energy Efficiency Ratio
Full load ( the higher the better )
kW
A
A
B
C
D
E
F
G
ASH-12AIP PT
62229925973
550
3.53
3.21
4.10
A
B
CDEFG
39/53
3.61
Energy
Manufacturer
Unit model
More efficient
Less efficient
Air cooled Water cooled
Noise
(() )
dB A re 1 pW
Further information is contained in product brochures
Norm EN 14511 Air-conditioner Energy Label Directive 2002/31/ CE
Type
Cooling only Cooling+Heating
kW
Heat output Heating performance
A: higher
G: lower
Annual Energy Consumption kWh in cooling mode
( Actual consumption will depend
on how the appliance is used and climate)
Cooling output Energy Efficiency Ratio
Full load ( the higher the better )
kW
A
A
B
C
D
E
F
G
ASH-18AIP PT
62229925974
800
5.30
3.31
5.70
A
BCDEF
G
55/64
3.61
Energy
Manufacturer
Unit model
More efficient
Less efficient
Air cooled Water cooled
Noise
(() )
dB A re 1 pW
Further information is contained in product brochures
Norm EN 14511 Air-conditioner Energy Label Directive 2002/31/ CE
Type
Cooling only Cooling+Heating
kW
Heat output Heating performance
A: higher
G: lower
Annual Energy Consumption kWh in cooling mode
( Actual consumption will depend
on how the appliance is used and climate)
Cooling output Energy Efficiency Ratio
Full load ( the higher the better )
kW
A
A
B
C
D
E
F
G
ASH-24AIP PT
62229925975
992.5
6.45
3.24
7.00
A
BCDE FG
42/54