Sinclair ASH-09AIN PT, ASH-12AIN PT Operation Manual

Page 1
OPERATION MANUAL
ASH-09AIN PT, ASH-12AIN PT
NORDIC SERIE
Page 2
9
11
11
12
13
16
18
19
20
6
5
2
1
SINCLAIR
Page 3
Structure and operation
Name of each part
Indoor Unit
Outdoor Unit
Air in
Surface panelDisplay
power
plug
Air out
Louver
Zoom in the display
Remote control
Set Temp
Heating
Cooling
AutoPower/Run
anDrying
Drain hose
Air in
Air out
pipe and
Connection pipe and
connecting wire
Page 4
The instructions before use
Page 5
Page 6
195V
Page 7
Models & specifications
ASH-09AIN PT ASH-12AIN PT
Cool/Heat Cool/Heat
2500W (1120W~3000) 3600W (1220~4000)
2750W (1200~3200) 4100 (1310~4300)
6.2/6.3 7.0/7.2
6.7 7.2
1400/1450 1600/1650
780/760 1050/1130
550 490
R410A/0.78 R410A/1.15
42/39/36/53 42/39/38/55
8.5/35 11/38
Indoor unit 770 x 190 x 250 830 x 285 x 189
Outdoor unit 848 x 260 x 540 848 x 260 x 540
1. All above should be changed without notice; there are latest and accurate specifications on the nameplate
of your air conditioner.
2. When the unit is restarted after it was stopped, it can automatically resume in its most latest running mode,
and the outdoor unit starts a little bit later.
Working temperature range:
Indoor side DB/WB (°C) Outdoor side DB/WB (°C)
Maximum cooling 32/23 43/26
Maximum cooling 21/15 21/-
Maximum heating 27/- 24/18
Maximum heating 20/- -14/-15
IP24
T1
I
Working temperature range
Model
Air Cleaner
220-240~
50
Noise (Indoor/Outdoor) dB (A)
Climate type
Anti-electric shock protection
Weight (kg) Indoor unit/Outdoor unit
Cooling/Heating power input (W)
Recycling air Volume (m
3
/h)
Refrigerant and weight (kg)
Water proof level
Dimension (mm)
W x H x D
Functions
Accessory
Cooling capacity (W)
Heating capacity (W)
Power supply (V)
Frequency (Hz)
Cooling/Heating rated current (A)
Maximum input current (A)
Cooling/Heating rated power (W)
Page 8
Note:
Be sure that there is on obstruction. Don’t drop or throw the remote control. Don’t place the remote control in a location exposed to direct sunlight. Whe the unit is restarted after stopped,it can automatically resume its most latest runningmode,andtheoutdoorunitstartsalittlebitlater.
Romote control operation procedure
Name and Function-Remote conteol
SLEEP Button
At COOL, DRY, HEAT
mode, press the button  could start the SLEEP
FAN SPEED Button
At unit turned on, under AUTO, COOL, FAN, HEAT modes,press this
button could select 
the Auto Fan speed,  Low, Med , High fan  speed,in DRY mode,the 
MODEButton
At unit turned on,press  this button could select AUTO, COOL, DRY, FAN
CLOCK Button
Press this button once, the clock icon flash,  the time can be adjusted. When pressing TIME +, 
the one units of the 
minute will be increased
1,continuously press  1second above,the tens  place of the minute will be increased 1 in every
half second. When pre-
At COOL, DRY, FAN or  HEAT mode, press these two buttons could set up the temperature,the setting range is 16℃ -30℃,in each mode the memory function is av- ailable in Temperature
TEMP+ TEMP- Button
setting .
or HEAT mode.
fan speed is low fan
speed. Each mode.the
memory function is  available in each mode.
function, when repr-
essed, will turn off the function.
ssing the TIME -,the one  units of the minute will
be decreased 1,and cont- inuously press 1 second above,the tens place of  the minute will be dec- reased 1 in every half second.After setup com-
pleted,After setup com- pleted,press CLOCK button for confirmation.
Page 9
Note:
This type of remote control is a kind of new current.Some buttons of the control which have extra function will be described below.
Name and Function-Remote control(continue)
ON/OFF Button
Press this button once
to turn on the unit, 
T-ON Button
Press this button once, enter into T-ON setting, the T-ON icon will flash. When pressing TIME +, 
the time of T-ON will 
be increased 1 minute,
continuously press 1  1 second above, the tens 
place of the minute will be increased 1 in every
TIME+ Button
Function instruction
please refer to: T-ON
when repressed to turn
off the unit.
half second, when pressing TIME -, will decrease  1minute,continuously  press 1 second above,  the tens place of minute 
will be decreased 1 in  every half second, that will circulate in 12hours.
button, T-OFF button, CLOCK button.
Liquid crystal displayer
It shows all set contents.
Press this button once, enter  into T-OFF setting,the T-OFF icon flashes.The function
T-OFF Button
is vailable in turn ON or 
TIME- Button
The function instruction
please refer to : T-ON 
CANCEL Button
Press this button once,
cancel all Timer setting.
turn OFF state.The method of setup is the same with T-ON.
button, T-OFF button,
CLOCK button.
At operating,When it is  pressed,the louvers start
SWING Button
to rotate automatically and stop when repressed again. When press it twice in one
second,the light on the panel of indoor unit will be turned on. When press it twice in one second again,the light will be turned off.
Page 10
Don’t confuse the new and worn or different batteries. Remove batteries when not in use for a longtime. The batteries can be used for about one year. The remote control should be lm or more away from television or audio device.
Howtoinsertbatteries
1.Remove the cover from the back of the remote control.
2.Insert the two batteries(Two AAA dry-cell batteries).
3.Re-attach the cover.
NOTE:
The sketch map for batteries change
Page 11
Operation Guided
9
Plasma Technology PLASMA TEC
Plasma Air Purification Technology PLASMA TEC produces a natural bio-climate rich in active oxygen molecules, known as ions. It creates optimal quantity of positive and negative oxygen ions. Such an ion-enriched environment is notably cleaner and fresher. Plasma Technology has the capacity of breaking down bacteria into harmless particles, air purification, odor neutralization and reduction of particles in the air. All these qualities make PLASMA TEC Technology invaluable also for allergic persons.
Page 12
10
Installtion location
Installtion
Indoor Unit
9. 
10
2.3
O utdoor unit
Page 13
11
Electric wiring
Earth requirement
Page 14
Installation dimension diagram
12
230
ASH-09AIN ASH-12AIN
Page 15
13
Install the indoor unit
Electric wiring
Install the connection pipes
Install the drainage hose
Install the piping hole
Install the rear panel
12
Page 16
14
ASH-09AIN
ASH-12AIN
black
the brown one to 3
Black
Brown
Page 17
15
Install the indoor unit
Page 18
16
Install the outdoor unit
Install the connection pipe
Electric wiring connection
Black
Brown
Page 19
17
Electric heating belt
Air purging and leakage test
Page 20
18
Test operation and check after installation
Test operation
Check after installation
Page 21
Care and maintenance
Care and maintenance
19
Page 22
20
Page 23
21
Page 24
22
Page 25
ENVIRONMENTAL INFORMATION
This unit contains fluorinated gases with greenhouse effect covered by the Kyoto Protocol. Maintenance and disposal must be carried out by qualified persons only. Refrigerant gas R410A, GWP = 1730
EXTRA REFRIGERANT CHARGE
Pursuant to Regulation EC 842/2006 on certain fluorinated greenhouse gases, in case of extra refrigerant charge, it is compulsory to:
- Fill in the label accompanying the unit inserting the factory quantity of refrigerant
charge (see the technical label), the extra refrigerant charge and the total charge.
- Apply the label next to the technical label applied on the unit. For the split-type air
conditioner apply on the outdoor unit.