Before operation please carfully read this manual.
Page 2
Contents
Structure Principle and Usage
Install Part
and
Repair
Maintenance
Structure and Function
Important Advice 2
Specificate Model and Technical Data 5
Name and Function of Every Button of Wireless Remote Control 6
Operation Guide 8
Install Note Items 9
Install of Indoor Unit 12
Install of Outdoor Unit14
Trial Run 17
Repair and Maintenance 18
When the unit cannot run normally 19
1
Page 3
Structure Principle and Usage
◆
Structure and Function
Indoor
unit
Panel
:
Heat
:Cool/Dry
:Run
:Auto
Air in
Air out
Filter
Power plug
Wireless remote control
Drainage hose
Wire connection
cover plate
Air in
Front grill of air outlet vent
Connection pipe and wire
Outdoor
unit
Air out
Page 4
Structure Principle and Usage
Important Advance (Read the follwoing items carefully before using the unit)
WARNING
Insert power plug firm enough
For loose insert may cause electric
shock or fire.
Don't share socket with other
appliances or use prelonged hose.
Or electric shock or fire may
occur.
Don't plug out power plug
when unit is operating.
Or electric shock or fire may
occur.
Don't operate unit with wet
hand for electric shock may occur.
Don't damage wire or use the
wire that is not appointed.
Or electric shock or fire may
occur.
Don't insert finger or stick-
like thing into air inlet and outlet
vents, or damage may occur.
Danger
Don't let cooled air blows body
directly for too long, and don't
set indoor temp. too low for it is
not good for health.
If abnormal phenomenon occurs
(like burning odor etc.), cut off
power supply first, then contact
Gree Service Center. If abnormal
continues, the unit may be damaged
and cause electric shock or fire.
Cut off power
Don't repair the unit yourself
for incorrect repair may cause
electric shock or fire. So, contact
Gree Service Center to have
unit repaired.
Page 5
Structure Principle and Usage
★Earthing: Earth must be
reliable! Earth wire should be
connected on special earth settings.
If there is no such settings, have it
connected by perfessional personnel
Don't connect earth wire onto gas
pipe, water pipe, blowing pipe or
place where perfessiona personnel
considers it unrealiable.
★Don't plug out the plug by
pulling the power hose.
Otherwise, fire may be caused
for over heat of wire.
★Plug out power plug when the
unit will not be used for a long time.
★Don't let the unit blows to
heater or cooker directly. Or carbon
monoxide poisoning may occur for
incomplete burn.
★Cut off power when cleaning
the unit. Otherwise, electric shock
or damage may occur.
★Chemical sprayer must be
placed 1m away from both indoor
and outdoor unit to prevent fire
or explosionor explosion
★Note if install chassis is
damaged. If the chassis is damaged
without repair, unit may fall down
and cause injury.
★Don't stand or put things on
the outdoor unit. For people or
things may fall down and cause
injury.
★Don't block the air inlet or outlet
vent of both indoor and outdoor unit.
It would cause low performance
or stop of unit.
Page 6
Structure Principle and Usage
NOTICE
Indoor temperature should be set properly
Proper set temp. can save electricity.
Temp. dif of
indoor and outdoors
should be5℃
When the unit is running, don't open windows
or doors of the room for long time.
It would lower performance of the unit.
Don't pour water on the unit or wash it by water
for malfunction or electric shock may occur.
●Adjust airflow and direction properly
When the unit is running, adjust up and down adjusting plate
by wireless remote control can adjust vertical direction of
air, hold the adjust plate that control left and rignt direction
can adjust horizontal flow direction of air.
Left and right adjust plate
●Don't blow pets or plants directly for it is not
good for them.
Power hose of this unit adopts X type connection, don't
cut off or damage it and signal control wire. If power
hose or signal wire is damaged, please have them
changed by trained maintainer.
Up and down adjust plate
The unit allow voltage fluctuation of 230±10%V,
too low of voltage may increase libration of
compressor that cause damage on cool system.
50Hz~230V
This unit cannot be used to dry clothes or refrigerate
and store foods etc..
4
Page 7
Structure Principle and Usage
Specificate Model and Technical Data
50Hz
230V~
T1
IP×4
Indoor:101.5×29.0×15
Outdoor:84.8×54.0×32.0
2000 2500 3500
Cooling and HeatingCooling and HeatingCooling and Heating
ASH-07AF ASH-09AFASH-12AF
Function
Model
Cooling Capacity(W)
2300 2700 3700
Heating Capacity(W)
4/4 4/4 6.26/6.26
450 450 500
/h)
3
920/920 920/920 1440/1440
Rated Voltage
Rated Frequency
Air Flow(m
Cooling/Heating Rated Power (W)
Cooling/Heating Rated Currency (A)
38/52 38/53 40/54
R410A 1. 2kg R410A 1.35kg R410A 1.4kg
Name of Refrigerant and Charge Amount
Noise (Indoor/Outdoor) dB(A)
Climate Type
Water-proof Level
Electric Shork Proof Protect TypeI Weight (Indoor/Outdoor) (kg)
11/32 11/32 11/36
(W ×H ×D)(cm)
All above are tested according to standard GB/T7725-1996, cooling capacity, heating capacity and noise etc. are tested before leaving factory
Outline Diameter (Indoor/Outdoor)
If the data are changed, please refer the one offered on nameplate.
Page 8
Remote control operation procedure
Note:
Be sure that there are no obstructions between receiver and remote controller.
The remote control signal can be received at the distance of up to about 10m.
Don’t drop or throw the remote control.
Don’t let any liquid in the remote controller and put the remote controller di-
rectly under the sunlight or any place where is very hot.
SWING button
REMOTE CONTROL OPERATION PROCEDURE
When it is pressed, the louvers
start to rotate automatically and
stop when repressed.
Name and Function-Remote control
FAN button
Press this button to change
the fan speed of:
TEMP. button
SET TEMP. increases 1
pressing button once,and decreases
1
by pressing button once.
At COOL mode operation, SET
TEMP. can be selected from 16
30
.
At DRY mode oper ation, SET TEMP.
can be selected from 16
At HEAT mode operation, SET
TEMP. can be selected from 16
30
.
MODE button
press this button to change the
operation mode in order of:
ON/OFF button (1/0 is
used in some models)
Press this button to turn on
or turn off the unit.
3
Page 9
Name and Function-Remote control. (Remove the cover)
Note:This type of remote controller is a kind of new controller.
some buttons of the controller which are not available to this Air condi-
tioner will not be described below.
Operate on unmentioned buttons would not impact on the normal use.
Liquid crystal displayer It
shows all set contents.
SLEEP button
Press this button to set
SLEEP operation. And stop
when repressed.
1/0 is used in some
models
TIMER ON button
At stopping, press TIMER
ON button, set ON TIME in
range of 0 to 24 hour at the
interval of 0.5h to start the
unit automatically.
024h
Timer
cancellation
TIMER OFF button
At operating, press TIMER
OFF button, set OFF TIME
in range of 0 to 24 hour to
stop the unit automatically.
024h
Timer
cancellation
REMOTE CONTROL OPERATION PROCEDURE
4
Page 10
REMOTE CONTROL OPERATION PROCEDURE
3.Press SWING button,
COOL mode operation procedure
According to difference between room temp. and set temp., microcomputer can control cooling on or
not.
If room temp. is higher than set temp., compressor runs at COOL mode.
If room temp. is lower than set temp., compressor stops and only indoor fan motor runs.
SET TEMP. should be in range of 16
the louvers start to rotate automatically, and
stop when repressed.
to 30
4.Press FAN button, set
fan speed.
5.Press TEMP. but-
ton, set suitable SET
TEMP.
2.Press MODE button,
set operation
mode.
1.Plug in, press ON/OFF button
(1/0 is used in some models),then
air conditioner is turned on.
5
Page 11
HEAT mode operation procedure
If room temp. is lower than set temp., compressor runs at HEAT mode;
If room temp. is higher than set temp., compressor and outdoor fan motor stop, only indoor fan motor
runs, louver motor makes the louvers horizontal.
SET TEMP. should be in range of 16
to 30
3.Press SWING button, the
louvers start to rotate
automatically, and stop
when repress it.
4.Press FAN button, set
fan speed.
5.Press TEMP. but-
ton, set suitable
SET TEMP.
REMOTE CONTROL OPERATION PROCEDURE
1.Plug in, press ON/OFF button
(1/0 is used in some models),
then air conditioner is turned on.
2.Press MODE button,
set operation
mode.
6
Page 12
DRY mode operation procedure
If room temp. is lower than set temp., compr essor ,outdoor and indoor fan motor stop. If r oom temp. is
REMOTE CONTROL OPERATION PROCEDURE
between
2 of set temp., Air conditioner is drying.If room temp. is higher than set temp., it’s at
COOL mode.
SET TEMP. should be in range of 16
3.Press SWING button,
the louvers start to rotate automatically, and
stop when repress it.
to 30
4.Press TEMP.button,set
suitable SET TEMP.
2.Press MODE button,set
operation mode.
Air speed couldn’t be
changed after the “ ”
being set.
7
1.Plug in,press ON/OFF button
(1/0 is used in some models),then
air conditioner is turned on.
Page 13
AUTO mode operation procedure
Under Auto mode operation, standard SET TEMP. is 25 for COOL mode and 20for H E AT
mode.
1.Plug in,Press ON/OFF button (1/0 is used in some
models), then air conditioner
is turned on.
2.According to room temp.,microcomputer can automatically set
operation mode,so
as for best effect.
REMOTE CONTROL OPERATION PROCEDURE
8
Page 14
REMOTE CONTROL OPERATION PROCEDURE
TIMER mode operation procedure
TIMER ON button
At stopping, press TIMER
ON button, set ON TIME in
range of 0 to 24 hour to start
the unit automatically.
1/0 is used in some models
TIMER OFF button
At operating, press TIMER
OFF button, set OFF TIME
in range of 0 to 24 hour to
stop the unit automatically.
024h
Timer
cancellation
024h
Timer
cancellation
9
Page 15
SLEEP mode operation procedure
As the unit is cooling or drying, if SLEEP operation is set, SET TEMP. would increase 1 in 1 hour
and 2
in 2 hours.
As the unit is heating , if SLEEP operation is set, SET TEMP. would decrease 1
2 hours.
4.Press FAN button, set
fan speed.
3.Press SWING button, the
louvers start to rotate
automatically, and stop
when repress.
6.SLEEP button
Press it to set SLEEP
operation.
in 1 hour and 2 in
5.Press TEMP. but-
ton, set suitable
SET TEMP.
2.Press MODE button,
set or operation mode.
REMOTE CONTROL OPERATION PROCEDURE
1.Plug in, press ON/OFF button
(1/0 is used in some models),then
air conditioner is turned on.
10
Page 16
1.Remove the cover from the back
of the remote control.
2.Insert the two batteries ( Two AAA
dry - cell batteries ) and press button “ACL”.
3.Re - attach the cover.
REMOTE CONTROL OPERATION PROCEDURE
NOTE:
How to insert batteries
Don’t confuse the new
and worn or different
types of batteries.
Remove batteries when
the remote controller is
not in use for a long
time.
The remote control signal can be received at
the distance of up to
about 10m.
The lifetime of the batteries is about one year.
The remote controller
should be placed about
1m or more away from
the TV. or any other
2. Insert the AAA batteries.
1.Remove the cover.
3.Re - attach the cover.
11
electric appliances.
Bad batteries are forbidden.
Page 17
Install Part
◆ Install Note Items
Select of install location
Indoor unit
1.The air inlet and outlet vent should be far away from obstruction to ensure the air
is blowed to the entire room.
2.Select where is easy to drain condensate or connect with outdoor unit.
3.Far away from heat resource, steam and flammable gas.
4.Select where can stand weight of indoor unit without increasing running noise and librations.
5.Ensure there is enough space for maintenance, and indoor unit should be at lest 2m above floor.
6.Place the unit to where is at lest 1m away from TV, Hi-fi and other appliances.
7.Select where air filter can be taken out easily.
8.Ensure the install of indoor unit meets requirements on Install Dimension Diagram.
Outdoor unit
1.Select place where noise and airflow produced when exharsting will not annoy neighbours.
2.Ensure well ventilation of outdoor unit.
3.There is no obstruction that may impact air in and out nears outdoor unit.
4.Install place should be able to stand weight and libration of outdoor unit and let the
outdoor unit run safely.
5.Select place where there is no leakage of flammable or corrosible gas.
6.Ensure the install of outdoor unit meets requirements on Install Dimension Diagram.
9
Page 18
Install Part
Wire collocation
1.Wire should be connected according to local wiring regulation.
2.Power supply must adopt rated voltage and special circuit for air conditioner,
and size of the power wire should be big enough.
3.Please don't pull power wire forcibly.
4.Earthing should be reliable, and should be connected on special earthing settings on building,
and have them connected by professional personnel. Creepage protect switch and air switch
with enough capacitance must be set in rated circuitry (Refer to the following form). Air switch
should maintain magnetic and heat drop-out functions to ensure protect when curcuit short or overload occurs.
Model
ASH-07AF
ASH-09AF
ASH-12AF
Capacitance
of air switch
10A
10A
15A
Earth wire
min section
2
1.0mm
2
1.0mm
2
1.5mm
Power wire of unit
min. section
2
1.0mm
2
1.0mm
2
1.5mm
Earthing requirements
1.Air conditioner is type I appliance, please do conduct reliable earthing measure.
2.The yellow-green wire in the unit is earth wire, don't use it for other purpose or cut it.
Don't fix it by self tapping screw, or electric shock may occur.
3.User power supply should offer reliable earth terminal. Don't connect earth wire to
The installation must be done by professional personnel with reliability
according to this manual.
★
Contact service center before installation to avoid the malfunction due
to unprofessional installation.
★
When moving the units, you must be guided by professional personnel.
Distance between
unit and slider
Distance between unit and wall
Air in side
Distance between unit and wall
Air out side
11
Page 20
Install Part
◆ Install the indoor unit
☆ Install the rear panel
1.Always mount the rear panel horizontally.As the water drainage pipe at
the left,this side should not be too
high when adjusting the rear panel.it
had better to adjust this side a little lower.
2.Fix the rear panel on the selected location.
3.Be sure that the rear panel has been fixed firmly enough to withstand
the weight of an adult of 60kg,furthermore,the weight should be
evenly shared each screw.
☆
Install the piping hole
1.
Make the piping hole(¦Õ50) in the wall at a slight downward slant t
the outdoor side.
2.
Insert the piping-hole sleeve into the hole to prevent the connection
piping andwiring from being damaged when passing through the hole.
☆
Install the drain hose
1.For well draining, the drain hose shoule be placed
at a downward slant.
2.Do not wrench or bend the drain hose or flood its
end by water.
3.When the long drainage hose passing through indoor
should wrap the insulation materials.
☆
Install the connection pipes
Connect the connection pipes with the relevant union pipes of the indoor unit and
tighten the flare nut of the connection pipes (Shown in P19"Install the connection
pipes")
Fig.1
Wrenched
Fig.2
o
Bent
Don't soak in the water
Note:
▲
Connect the connection pipes with the indoor unit
firstly and the outdoor unit secondly.
▲
Be careful in bending the connection pipes or you
will damage the pipe.
▲
If the tightening torque is too great in tightening
the flare nuts, leakage will happen.
☆
Electric wiring
connection power inside and
outside the unit
1.Open the panel upwards.
2.Disassembly the fixing bolts of connection cover , shown in the Fig. at right side.
3.power connecting wire cross through down to up from the bottom of case.
12
cover of connection
Page 21
Install Part
4.Connect blue wire in power connect wire onto "N(1)" terminal, brown wire onto "2" terminal,
yellow-green wire (i.e. earth wire) onto " " terminal (as shown in fig.3); and press the
power connect wire by wire groove that in front of line bank that installed in electric box.
5.To heat pump type unit, signal control wire connect with indoor unit through connector
as (shown in fig.3), and tighten the control wire by wire clamp on bottom of case.
6.Install the cover plate on where it was and tighten screws.
7.Cover panel.
Signal control wire (only for heat pump units)
Line bank
Connector
Wire
blue
brown
yellow-green
gloove
Power connect
Wire clamp
wire
Fig.3
☆Install Indoor Unit
1.Please refer to the fig. (a) and (b) for routing piping type of indoor unit. When routing the
piping (wiring) from the left or right side, cut off the tailings of the pipe left from chassis
of main unit (as shown in fig.4(c)):
(1)Cut off tailings 1 when only power cord is routed;
(2)Cut off tailings 1 and 2 when connection pipe and power cord are routed.
13
Page 22
Install Part
Methods ①、②、③ are recommended piping ways.
2.After wrapped pipe and wire, pull them though the pipe hole (as shown in fig.5).
3.Hang the mounting slot behind indoor unit on the pothook of the rear panel and move
it to check if it is firm enough (as shown in fig.6).
4.Ensure the install height of indoor unit is 2m or higher.
①Right pipe
②Rear right pipe
(a)
Wrapping strap
Coonection pipe
Power connect wire
Tailings 2
Tailings 1
Fig.5
Fig.4
(c)
Fig.6
◆ Install of Outdoor Unit
(b)
Drainage hose
④Left pipe
③Rear left pipe
Signal control wire
☆Install connection pipe
1.Aligh the flare of connection pipe to the joint flare of relative valve.
2.Tighten the nuts on connection pipe forcibly then tighten ti by spanner as shown in fig.7.
Note: Too great of torque would damage nuts.
14
Page 23
Install Part
Tightening torque table
Hex nut
Ф6
9.5
12
Tightening torque table(N·m)
15~20
31~35
50~55
☆ Electric wiring connection
Nut of connection pipe
Torque wrench
Spanner
Joint
Fig.7
1.Take off handle on right side plate of outdoor unit (1 bolt).
2.Take off clamp, then connect and fix the power connect wire to wiring terminal
board.Wiring allocation should be in accordance with that of indoor unit.
3.Fix power connect wire by clamp, to cooling and heating unit, fix signal control wire too,
then connect the corresponding connector well.
4.Ensure that the wiring is done well.
5.Install handle (tightened by 1 bolt).
(3) Cut-off valves of both thick and thin pipes should be turned on.
(4) All scattered components, especially metal scrap thrum etc., should be cleared from unit.
2. Trial running mothod
(1)
Press ON/OFF on wireless remote control after connecting to power supply, unit begins running.
(2)
Press MODE to select run mode of COOL, HEAT and SWING etc. to check if it can run normally.
(3) When wireless remote control is losed, operation unit by following mode:
(a) When unit is halt, press the ON/OFF button, then unit begins running in AUTO micro-
computer select COOL, DRY, HEAT or FAN automatically according to indoor temp.
to make comfort effect. Repress ON/OFF to stop the unit from running.
(b) When unit is running, press ON/OFF to stop unit from running.
Heating indicator
Cooling indicator
ON/OFF button
Running indicator
☆ Check after installation
Items to be checked
Is the installation firm enough?
Is leakage test done?
Is heat insulation sufficient?
Is drainage smooth?
Is the power voltage the same with that in
product nameplate?
Is the install of circuit and pipeline correct?
Is the unit earthed safely?
Is model of wire fits that of regulation?
Is both the air inlet or outlet vent of indoor
and outdoor unit blocked?
Is length of refrigerant pipe and charge amount recorded
Creepage may occur
Possible malfunction
Unit may drop, shake or emit noise
It may cause insufficient of cooling (heating) capacity
Condensation or water drop may occur
Condensation or water drop may occur
Malfunction or burn out of parts may occur
Malfunction or burn out of parts may occur
Malfunction or burn out of parts may occur
Insufficient of cooling (heating)
capacity may occur.
?
Charge amount of refigerant is hard to handle.
17
Page 26
Repair and Maintenance
Repair and Maintenance
◆
Warning
▲Stop the unit and pull out the plug before cleaning the unit,or electic shock will be happened.
▲Don't get wet the unit,for it will cause the electric shock,make sure don't wash
the unit by water.
▲The volatile liquid,such as thinner or gas will damage the face of unit. (only using
the soft cloth and wet cloth with neutral cleaning fluid to clean the body of unit)
When the following circumstance occur, stop the unit from running
immediately and plug out power plug, then contact Gree Service Center.
▲Harsh noise is heard when the unit is running;
▲Air switch or creepage protect switch often trips;
▲Other things or water poured into unit or wireless
remote control carelessly;
▲Indoor water leakage occurs;
▲Power hose and power plug are extremely hot.
▲Abnormal odor is produced when the unit is running.
Please contact Gree
Service center if there
is any problem
21
Page 30
ENVIRONMENTAL INFORMATION
This unit contains fluorinated gases with greenhouse effect covered by the Kyoto Protocol.
Maintenance and disposal must be carried out by qualified persons only.
Refrigerant gas R410A, GWP = 1730
EXTRA REFRIGERANT CHARGE
Pursuant to Regulation EC 842/2006 on certain fluorinated greenhouse gases, in case of extra
refrigerant charge, it is compulsory to:
- Fill in the label accompanying the unit inserting the factory quantity of refrigerant
charge (see the technical label), the extra refrigerant charge and the total charge.
- Apply the label next to the technical label applied on the unit. For the split-type air
conditioner apply on the outdoor unit.
Page 31