Simpson G100, G200, G300, G400 Data Sheet

• Four model types designed to fit a wide range of applications
• One meter to measure all your values
• Easy installation - software detection/ correction of wiring errors
• Wide backlit LCD display for easy viewing
• Easy to use - four keys select all parameters
• Use for single or three-phase applications
• Modbus communication option available
3-phase, 3 or 4 wire unbalanced load 120/208, 120/240, 277/480, 63/110 20% to 120% 5 amp from external CTs Fully Isolated 5% to 120% 45 to 65 Hz Up to the 30th harmonic
Less than 0.1VA per phase Less than 0.1VA per phase
x2 for 2 seconds max. x40 for .5 second max.
115V±15% 45-65Hz 230V±15% 45-65Hz Custom backlit supertwist LCD 3 lines of .47” (12mm) digits plus .15” (3.8mm) legends Once/Second
14°F to 149°F (-10°C to 65°C) operating <75% RH non-condensing
5amp to 6500 amp 60v to 50,000v 2
Wh (G200, G300 & G400 only) Total varh (G300 & G400 only) 100ms to 20 seconds
2.2KV (50V Output No. 1 to Output No. 2) Settable 1, 10 or 100 pulse output rate
INPUT System Voltages
Measurement range
Current
Measurement range
Operating Frequency Harmonics Input Loading
Voltage Current
Overload
Voltage Current
Auxiliary Supply
Standard Optional
Display General Update Rate
ENVIRONMENTAL Temperature Humidity Programming
CT Primary VT Primary
Pulse Outputs Function
Output No. 1 Output No. 2
Pulse Length
Isolation Scaling
ACCURACY
Note:
MECHANICAL
Bezel Depth Panel Cutout Weight
*Rdg = Reading
3.79” x 3.79” (w/ .29” lip)
3.35”
3.62” x 3.62” 14 oz.
Specifications
A
15
Parameter
Phase Current
Neutral Current
Phase Voltage
Voltage LL
Phase Watts
Phase VA
Phase var
Phase PF
System Watts
System VA
System var
System PF
Frequency
% THD Amps
% THD Volts
Spec Range Spec
5% to 120% lb ±0.2% lb (1% Rdg) ±1 Digit
5% to 120% lb ±0.6% lb (2% Rdg) ±1 Digit
20% to 120% Vb ±0.2% Vb (1% Rdg) ±1 Digit
20% to 120% Vb ±0.3% Vb (1% Rdg) ±1 Digit
5% to 120% FS ±0.4% FS (1% Rdg) ±1 Digit
5% to 120% FS ±0.6% FS (1.5% Rdg) ±1 Digit
5% to 120% FS ±0.8% FS (2% Rdg) ±1 Digit
±0.2 Degrees
5% to 120% FS ±0.6% FS (1% Rdg) ±1 Digit
5% to 120% FS ±1% FS (1.5% Rdg) ±1 Digit
5% to 120% FS ±1.5% FS (2% Rdg) ±1 Digit
±0.2 Degrees
45Hz to 65Hz ±.05 Hz
5% to 120% lb ±0.5 Hz
20% to 120% Vb ±0.5 Hz
more >>
Models & Parameters
Accessories - Three-Phase Current Transformer
A three-phase terminal style current transformer must be used with GIMA® three phase meters.
The current transformer is equipped with terminals to permit easy con­nection to the GIMA units. These terminals are #8-32 brass studs and come with a flatwasher, lockwasher and a regular nut (leads are not provided).
Catalog Number
37026 37027 37028 37029 37030
Current Ratio
50:5 100:5 150:5 200:5 300:5
Accuracy @ 60Hz
± 3% ± 1% ± 1% ± 1% ± 1%
Burden VA @ 60 Hz
2.0
2.0
4.0
5.0
10.0
Ordering Information
Ordering Information
BBaassiicc UUnniitt
PPoowweerr
VVoollttaaggee IInnppuuttss
OOtthheerr
CCuurrrreenntt IInnppuutt
100 200 300 400
1 2
1
0 1
1 2 3 4
G
For other Voltage and Current Inputs, contact Simpson Electric Company
* RS485/422 communications
BBaassiicc UUnniitt
GIMA 100 Meter GIMA 200 Meter GIMA 300 Meter GIMA 400 Meter
PPoowweerr SSuuppppllyy
115 VAC @ 45-65Hz 230 VAC @ 45-65 Hz
VVoollttaaggee IInnppuutt
120/208V 120/240V - Split Phase 277/480V
63/110V
CCuurrrreenntt IInnppuutt
5 amp
OOtthheerr
None Modbus Communication*
Mounting Requirements
Panels should be .04 to .16 inches (1mm to 4mm) thick with a square cut-out of 3.62” x 3.62” (92mm x 92mm.) A minimum depth of 2.83” (72mm) should be allowed behind the panel for the meter. Remove the panel mounting clips and insert the meter into the cut­out from the front of the panel. Push the meter home. Ensure the screws in each panel mount clip are fully retracted and insert the clips as shown in the diagram below. Tighten the screws to secure the meter firmly in the panel.
Do not overtighten.
A
16
G100 G200 G300 G400
Phase Amps XXXX
Line Volts XXXX
Per Phase kW XXXX
Per Phase kVA X
3 Phase kW XXXX
3 Phase kVA X
KWh X X X
Inductive kvarh X X
Import kvarh X
Voltage Demand XXXX
Peak Amps X
Peak Current Demand XXXX
Neutral Current X
Phase Volts X X X X
Per Phase PK X X X X
Per Phase kvar X X
3 Phase PF X X X X
3 Phase kvar X X
Frequency XXXX
Capacitive kvarh X X
Total kvarh X X
Current Demand XXXX
kW Demand X X
Peak Phase Volts X
Peak Voltage Demand XXXX