1.3 GENERAL DATA
TABLE 3a - Nominal boiler ratings (2 minutes after lighting) for Superior 40 Ci EI
MODE OUTPUT INPUT (N.C.V.) INPUT (G.C.V.) BURNER PRESSURE
kW Btu/h kW kW Btu/h mbar inwg
CENTRAL HEATING RANGE 8.8 30,000 10.0 11.1 37,800 5.4 2.2
9.1 31,000 10.3 11.4 38,900 6.0 2.4
9.4 32,000 10.6 11.8 40,100 6.4 2.6
9.7 33,000 10.9 12.1 41,200 6.7 2.7
10.0 34,000 11.2 12.4 42,300 7.1 2.9
10.3 35,100 11.5 12.8 43,500 7.5 3.0
10.6 36,100 11.8 13.1 44,600 7.9 3.2
10.9 37,100 12.1 13.4 45,700 8.3 3.3
11.2 38,100 12.4 13.8 46,900 8.7 3.5
11.5 39,200 12.7 14.1 48,000 9.2 3.7
X* 11.8 40,200 13.0 14.4 49,100 9.6 3.9
*Factory setting
TABLE 3b - Nominal boiler ratings (2 minutes after lighting) for Superior 50 Ci EI
MODE OUTPUT INPUT (N.C.V.) INPUT (G.C.V.) BURNER PRESSURE
kW Btu/h kW kW Btu/h mbar inwg
CENTRAL HEATING RANGE 11.9 40,500 13.2 14.7 49,900 9.7 3.9
12.2 41,500 13.5 15.0 51,000 10.2 4.1
12.5 42,600 13.8 15.3 52,200 10.7 4.3
12.8 43,600 14.1 15.7 53,300 11.3 4.5
13.1 44,600 14.5 16.1 54,800 11.9 4.8
13.4 45,600 14.8 16.4 55,900 12.5 5.0
13.7 46,700 15.1 16.7 57,100 13.0 5.2
14.0 47,700 15.4 17.1 58,200 13.6 5.5
14.3 48,700 15.7 17.4 59,300 14.1 5.7
X* 14.6 49,700 16.0 17.8 60,500 14.7 5.9
*Factory setting
TABLE 3c - Nominal boiler ratings (2 minutes after lighting) for Superior 60 Ci EI
MODE OUTPUT INPUT (N.C.V.) INPUT (G.C.V.) BURNER PRESSURE
kW Btu/h kW kW Btu/h mbar inwg
CENTRAL HEATING RANGE 14.7 50,000 16.4 18.2 62,000 10.4 4.2
15.0 51,000 16.7 18.5 63,100 10.8 4.3
15.3 52,100 17.0 18.9 64,300 11.2 4.5
15.6 53,100 17.3 19.2 65,400 11.6 4.7
15.9 54,100 17.6 19.5 66,500 12.0 4.8
16.2 55,200 17.9 19.9 67,700 12.5 5.0
16.5 56,200 18.3 20.3 69,200 13.0 5.2
16.8 57,200 18.7 20.8 70,700 13.6 5.5
17.1 58,200 19.0 21.1 71,800 14.1 5.7
X* 17.5 59,600 19.4 21.5 73,300 14.7 5.9
*Factory setting