Revision Date Software Version Description of Change
1.1 14 March 2006 2.39.14 L or higher
1.0 14 October 2004 2.39.14 L or higher Initial ve rs ion.
F1 and F2 codes added to ‘Remote
control keycodes’ section and Zoom and
Focus codes moved t o ‘Di r ect access
codes’ section.
2
Page 3
K
S
RS-232C CONTROL SPECIFICATION
SIM2 HT300 E-LIN
1. Introduction
This document describes the communicati on and data formats used to control SIM2 HT300 E-LINK projector
via RS-232C port.
2. Connection
Switch off your Personal Computer and Projector before connecting RS 232C cable.
Use a standard serial cable with 9 pin female to the Personal Computer and 9 pin male to the Projector: pin 2
connects to pin2, pin 3 to pin 3 and pin 5 to pin 5.
SIM2 HT300 E-LINK RS-232C Port is described as follows.
SIM 2 HT300 E-LINK RS-232C Control Port:
D-SUB 9-pin
(female)
51
96
Pin No Signal Definition
1 N/A Not used
2 TD Transmit data
3 RD Receive data
4 N/A Not used
5 GND Ground
6 N/A Not used
7 N/A Not used
8 N/A Not used
9 N/A Not used
Switch on the Personal Computer and, after start up, switch on the Projector.
Load a suitable communication software onto your Personal Computer, and set the Serial Port Parameters as
shown below.
Communication Parameters:
Parameter Value
Transfer Rate 19200 bps
Data Bits 8
Parity Bit None
Stop Bit 1
Flow Control None
Set Send Mode and Read Mode to HEX.
3
Page 4
K
S
RS-232C CONTROL SPECIFICATION
SIM2 HT300 E-LIN
3. Communication Protocol
The communication protocol is packet oriented. Packets consists of Header and Payload.
There are two types of packets: Event and Operation.
The packet header size is fixed (7 bytes), while the packet payload type and content varies based on the type
of packet: Event payload size is 6 bytes, while Operation payload size is 25 bytes.
The entire packet size is variable, being the sum of the fixed-size packet header and variable-sized packet
payload: Event packet size is 13 bytes and Operation packet size is 32 bytes.
Each packet received by the projector is acknowledged with a return code:
06: Acknowledged with no error
-
15: Acknowledged, but an error has occurred.
-
Header
All Packets use the same Packet Header format.
The Packet Header size is fixed at seven bytes.
0xEFBE is a fixed value that is used to insure packet alignment if there are partial packets received or byte
lost. The ls-byte of the word 0xBE is sent first, then the ms-byte 0xEF.
The Packet Type is a number (a byte in length) that defines the type of data in the packet.
The Packet Payload Size is a number (two bytes) that defines the size of the payload portion of the packet.
For a given Packet Type, Packet Size is fixed.
The Packet Checksum (two bytes) is the CRC value for the entire packet (Header and Payload).
0 1 2 3 4 5 6
BEEF
Packet Type Packet Payload Size Packet Checksum (CRC)
Payload
The packet payload format depends on the packet type.
The Event packet payload size is 6 bytes, while the Operation packet payload size is 25 bytes.
Event Packet Format:
0 1 2 3 4 5
Event
Operation Packet Format:
0 1 2 3 4 5 6 7 8 9 10 11 12
Op TypeOp ID
13 14 15 16 17 18 19 20 21 22 23 24
00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00
00 00
Op Target
4
00 00
Op Value
0000
Page 5
K
S
RS-232C CONTROL SPECIFICATION
SIM2 HT300 E-LIN
4. Commands
Remote Control Keycodes
The following commands send simulated Remote Control input to SIM2 HT300 E-LINK proje ctor.
Remote Control Keycodes:
Key Command
STAND BY
(1)
0
(2)
1
(2)
2
(2)
3
(2)
4
(2)
5
(2)
6
(2)
7
(2)
8
(2)
9
(2)
10
(2)
11
(2)
12
ESC
CURSOR UP
CURSOR LEFT
CURSOR RIGHT
CURSOR DOWN
MENU LEFT (-)
MENU RIGHT (+)
FREEZE
MEMORY
F1
F2
INFO
AUTO
ASPECT NORMAL
ASPECT ANAMORPHIC
ASPECT LETTERBOX
ASPECT PANORAMIC
ASPECT PIXEL TO PIXEL
BE EF 02 06 00 51 E4 48 01 00 00 00 00
BE EF 02 06 00 6B E6 52 01 00 00 00 00
BE EF 02 06 00 80 E5 49 01 00 00 00 00
BE EF 02 06 00 B3 E5 4A 01 00 00 00 00
BE EF 02 06 00 62 E4 4B 01 00 00 00 00
BE EF 02 06 00 D5 E5 4C 01 00 00 00 00
BE EF 02 06 00 04 E4 4D 01 00 00 00 00
BE EF 02 06 00 37 E4 4E 01 00 00 00 00
BE EF 02 06 00 E6 E5 4F 01 00 00 00 00
BE EF 02 06 00 89 E7 50 01 00 00 00 00
BE EF 02 06 00 58 E6 51 01 00 00 00 00
BE EF 02 06 00 BC E0 75 01 00 00 00 00
BE EF 02 06 00 8F E0 76 01 00 00 00 00
BE EF 02 06 00 5E E1 77 01 00 00 00 00
BE EF 02 06 00 0D E6 54 01 00 00 00 00
BE EF 02 06 00 DC E7 55 01 00 00 00 00
BE EF 02 06 00 EF E7 56 01 00 00 00 00
BE EF 02 06 00 3E E6 57 01 00 00 00 00
BE EF 02 06 00 C1 E6 58 01 00 00 00 00
BE EF 02 06 00 10 E7 59 01 00 00 00 00
BE EF 02 06 00 23 E7 5A 01 00 00 00 00
BE EF 02 06 00 F2 E6 5B 01 00 00 00 00
BE EF 02 06 00 45 E7 5C 01 00 00 00 00
BE EF 02 06 00 E6 F4 8F 01 00 00 00 00
BE EF 02 06 00 89 F6 90 01 00 00 00 00
BE EF 02 06 00 A7 E6 5E 01 00 00 00 00
BE EF 02 06 00 79 E2 60 01 00 00 00 00
BE EF 02 06 00 2A F4 83 01 00 00 00 00
BE EF 02 06 00 9D F5 84 01 00 00 00 00
BE EF 02 06 00 4C F4 85 01 00 00 00 00
BE EF 02 06 00 7F F4 86 01 00 00 00 00
BE EF 02 06 00 AE F5 87 01 00 00 00 00
5
Page 6
K
S
RS-232C CONTROL SPECIFICATION
SIM2 HT300 E-LIN
ASPECT USER 1
ASPECT USER 2
ASPECT USER 3
VCR
BE EF 02 06 00 51 F5 88 01 00 00 00 00
BE EF 02 06 00 80 F4 89 01 00 00 00 00
BE EF 02 06 00 B3 F4 8A 01 00 00 00 00
BE EF 02 06 00 9B E3 62 01 00 00 00 00
Direct access codes
Zoom
Focus
Goto Brightness
Goto Contrast
Goto Color
Goto Tint
(1)
When the unit is in Stand-by state, this command switches on the unit and the last source memorised
prior to switch off is automatically selected.
(2)
When the unit is in Stand-by state, this command switches on the unit and selects the corresponding
BE EF 02 06 00 94 E6 5D 01 00 00 00 00
BE EF 02 06 00 76 E7 5F 01 00 00 00 00
BE EF 02 06 00 C7 E1 7E 01 00 00 00 00
BE EF 02 06 00 16 E0 7F 01 00 00 00 00
BE EF 02 06 00 19 F4 80 01 00 00 00 00
BE EF 02 06 00 C8 F5 81 01 00 00 00 00
Source.
6
Page 7
K
S
RS-232C CONTROL SPECIFICATION
SIM2 HT300 E-LIN
Operation Codes
The following codes provide direct access to SIM2 HT300 E-LINK User Interface operations not accessible via
a single Remote Control command.
Operation Codes:
Operation Action Command
BE EF 03 19 00 AB 7E 03 00 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
1. Send the simulated "SWITCH ON FROM STAND-BY AND SELECT SOURCE" Remote Control
keycode.
Remote Control allows Switching on from Stand-by via one of the keys "1", "2" ... "11", "12".
Send, for instance, the code relative to key "1": BEEF02060080E5490100000000.
The projector switches on and selects Input 1.
The projector returns the response code: 06 (Acknowledged with no error).
NOTE: Commands that simulate keys "1", "2" ... "11", "12" switch on the unit and select the
corresponding Source.
Command that simulate key 0 switches on the unit: the last source memorised prior to switch off is
automatically selected.
2. Send the simulated "MENU RIGHT" Remote Control keycode.
Send the packet: BEEF02060023E75A0100000000.
The OnScreen Display appers on the screen.
The projector returns the response code: 06 (Acknowledged with no error).
3. Send the "SET ASPECT ANAMORPHIC" Operation Code.
Send the packet: BEEF0206009DF5840100000000.
11
Page 12
K
S
RS-232C CONTROL SPECIFICATION
SIM2 HT300 E-LIN
The Aspect Ratio changes to Anamorphic.
The projector returns the response code: 06 (Acknowledged with no error).
4. Select "INPUT 5 (COMP RGB 1) WITH YcrC b 15kHz SIGNAL"
Send the packet: BEEF0319005B0C01820800000000000008000000000000000000000000000000
Wait for the return code and add an additional delay of 40 ms.
Send the the code relative to the Key to which Input 5 has been assigned: for instance if the key is "3"
the code is: BEEF02060062E44B0100000000
6. Warnings
When the number of bytes sent to the Projector is greater than indicated for the Command (32 bytes for
Operation Packets and 13 bytes for Event Packets), excess data will be ignored.
Conversely, if number of bytes sent to the Projector is smaller than required by the Communication Protocol,
an Error Code will be returned.
Allow a time interval of at least 40 ms between the Return Code and the following Command.