Thank you for purchasing Silver King food service equipment. Our goal is to provide our customers with the most reliable equipment in the industry today. Please read this manual and the accompanying warranty information before operating your new Silver King unit. Be sure to complete and mail the warranty card within 10 days of purchase to validate your warranty.
INSPECT FOR DAMAGE AND UNCRATE
Upon delivery of your new Silver King unit, uncrate at once to examine and test for possible damage following the instructions printed on the exterior of the container. Report any damages to the carrier responsible for transportation and promptly present a claim for any evidence of mishandling. If a claim is to be filed, be sure to save all packaging materials.
INSTALLATION
The stainless steel exterior of the cabinet has been protected by a plastic covering during manufacturing and shipping. This covering can be readily stripped before installation. After removing this covering, wash the interior and exterior surfaces using a warm, mild soapy water solution and a sponge or soft cloth, rinse with clean water and wipe dry. Do not use any compounds containing chlorine to clean the stainless steel surfaces.
Also, wash the Pumps, Jars and Ladles prior to use. To wash the interior of the Pumps, fill a Jar with a hot soapy water solution and pump the solution through the Pumps. After this, pump clean water only through the Pumps to rinse them out. This procedure will need to be performed periodically to keep the Pumps operating properly and to keep them sanitary.
Location
When locating your new Silver King unit, convenience and accessibility are important considerations, but the following installation guidelines must be observed;
Always avoid locating the unit adjacent to an oven, heating element or hot air source which could adversely affect the performance of the unit.
The unit must be level.
For proper ventilation the unit requires a minimum of 4 inches of clear space around the louvered areas of the cabinet.
The counter must be able to support a minimum of 150 pounds.
This cabinet is designed to be sealed to the floor with a waterproof sealant as required by NSF International. To do so,
locate the unit in its desired location (following the installation instructions), apply a bead of sealant around the perimeter of the unit at the base and smooth out with a finger to form a radius with the floor and the unit.
Electrical Connections
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to a power source. The data plate specifications supersede any future discussion.
The standard unit is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase properly grounded electrical receptacle. The power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and could result in serious injury.
The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit and not plugged into an extension cord.
1
OPERATION
Initial Start Up
After satisfying the installation requirements, the unit is ready to start. The unit will start when the power cord is connected to the required power source. If the compressor does not start when the unit is initially plugged in, check to make sure that the temperature control is not in the ‘off ‘ position. Allow the unit to run a minimum of two hours before loading it with product.
Temperature Control
The Temperature Control is located on the compressor end of the unit. To obtain colder temperatures turn the Temperature Control knob clockwise and visa versa. Allow the unit a minimum of two hours to respond to a control setting adjustment.
Defrost Your Silver King unit is a manual defrost unit. It should be defrosted whenever the walls accumulate a frost layer that is ¼ inch thick. To defrost the unit, either turn the Temperature Control stem to the “off” position (fully counterclockwise) or disconnect the power from the electrical receptacle and remove the pans. After the frost has melted or come loose from the walls, wipe out the cabinet interior. Do not attempt to scrape or chisel off the frost as you could do irreparable damage to the unit.
MAINTENANCE Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of the appliance.
Cabinet Surfaces
The cabinet interior is aluminum and the exterior is stainless steel. These surfaces should be cleaned periodically with a solution of warm water and mild soap, rinsed with clean water and wiped dry with a soft cloth. A stainless steel cleaner can also be used. Should a surface become stained, do not attempt to clean with an abrasive cleaner or scouring pad. Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface. Do not use chlorinated cleaners.
Pumps To maintain the operation of the Pumps they should be disassembled and cleaned inside and out regularly. To do so, first remove the Pump from the Jar and immerse it in hot soapy water while operating the pump to purge the product that is inside of it. Repeat with clean water once the inside of the pump has been thoroughly purged. To disassemble the pump, refer to the parts list supplied for a complete breakdown of the Pumps.
Condenser Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply. To clear the dust, blow air though the condenser fins or remove the end panel and brush the dust from the backside of the condenser.
MODEL SERIAL NO. DATE INSTALLED
2
MANUAL TECNICO
SILVER KING
MODELO SKRCF
Gracias por comprar la maquinaria de servicios de alimentación Silver King. Nuestro objetivo es otorgar a nuestros clientes la mejor maquinaria de la industria actual. Sírvase leer este manual y la información acerca de la garantía que lo acompaña antes de poner en funcionamiento su nueva unidad Silver King. Asegúrese de completar y enviar por correo la tarjeta de garantía dentro de los 10 días posteriores a la compra a fin de ratificar su garantía.
INSPECCIONE LA UNIDAD EN BUSCA DE DAÑOS Y DESEMBALE
Cuando reciba su nueva unidad Silver King, desembálela inmediatamente y controle que no haya sufrido daños durante el transporte siguiendo las instrucciones impresas en la parte externa del envase. Si encuentra daños, infórmelo a la empresa responsable del transporte y presente inmediatamente un reclamo ante cualquier prueba de maltrato.
INSTALACION El exterior del gabinete de acero inoxidable ha sido protegido por una cubierta de plástico en la fabricación y envío. Esta cubierta puede ser retirada antes de la instalación. Una vez retirada la cubierta, lave las superficies internas y externas utilizando una solución de agua jabonosa y tibia y una esponja o paño, enjuague con agua limpia y seque.
Asimismo, lave las Bomgas, Jarras y Cucharones antes de utilizarlos. Para lavar la parte interior de las Bombas, llene una Jarra con una solución de agua jabonosa caliente y haga correr la solución a través de las bombas. Después, haga correr agua limpia solamente a través de las Bombas y séquelas. Este procedimiento debe ser llevado a cabo en forma periódica para mantener el correcto funcionamiento e higiene de las Bombas.
Ubicación Al elegir una ubicación para su nueva unidad Silver King, debe tener en cuenta la conveniencia y facilidad de acceso, pero debe seguir las siguientes pautas de instalación; * Siempre evite colocar la unidad cerca de un horno, elemento calefactor o fuente de aire caliente, quepueda afectar el funcionamiento de la unidad.
* Para lograr una ventilación adecuada, deje un espacio de al menos 10 centimetros (4 pulgadas) alrededor de las áreas de ventilación del gabinete.
* La unidad debe estar instalada derecha.
* El mostrador debe poder resistir un peso mínimo de 68 kilos (150 libras).
* El gabinete está diseñado para ser sellado a la superficie de la estructura soporte con un sellante impermeable conforme a las dispocisiones de NSF International. Para hacerlo, coloque la unidad en el lugar deseado (siguiendo las instrucciones de instalación), coloque un reborde de sellador alrededor del
Conexiones Eléctricas
Asegúrese de revisar la placa de datos ubicada en el revestimiento del gabinete para ver el voltaje requerido antes de conectar la unidad a una fuente eléctrica. Las especificaciones en la placa de datos sustituyen cualquier discusión posterior
La unidad estándar está equipado con un cable de transmisión de energía de 2,43 metros (8 pies) que requiere un receptor eléctrico con descarga a tierra de 115 Voltios, 60 Ciclos, 1 Fase. El cable de transmisión de energía incluye un enchufe de tres patas para la descarga a tierra. Cualquier intento de cortar la pata de descarga a tierra o de conectar el enchufe a un adaptador que no posea descarga a tierra anulará la garantía, eximirá a los fabricantes de responsabilidad y podría resultar en un serio daño.
El circuito debe estar protegido con un fusible o interruptor de 15 o 20 amperios. La unidad debe estar aislada en un circuito y no debe conectarse a una prolongación del cable.