TECHNICAL MANUAL
SILVER KING MOBILE FREEZER
MODELS SKMWF34, SKMWF44, SKMWF50
Thank you for purchasing Silver King food service equipment. Our goal is to provide our customers with the most reliable
equipment in the industry today. Please read this manual and the accompanying warranty information before operating your new
Silver King unit. Be sure to complete and mail the warranty card within 10 days of purchase to validate your warranty.
UNCRATE AND INSPECT FOR DAMAGE
Upon delivery of your new Silver King unit, uncrate at once to inspect for possible freight damage following the instructions printed
on the exterior of the container. Report any damages to the carrier responsible for transportation and promptly present a written
claim for any evidence of mishandling. Be sure to save all packaging materials if a claim is to be filed.
INSTALLATION
The stainless steel exterior of the cabinet has been protected by a plastic covering during manufacturing and shipping. The
covering can be readily stripped from the unit before installation. After removing the covering, wash the interior and exterior
surfaces using a warm, mild soapy water solution and a sponge or cloth, rinse with clean water and dry thoroughly.
Casters
The unit comes with the Casters installed. Check to make sure that the Casters are tightly fastened to the cabinet base to prevent
damage to the base.
Location
When locating the freezer, convenience and accessibility are important considerations, but the following factors must be observed:
• The unit must be level.
• Allow at least 6 inches of space at both ends to allow for proper air flow through the louvered panels. The space above the unit
should be open to allow access to the product.
• Avoid placing the freezer next to ovens, heating elements or hot air sources that would affect the performance of the unit.
Electrical Considerations
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to power. The
specifications on the data plate supersede any future discussion.
The standard freezer is equipped with an eight (8) foot power cord that requires a 230 Volt, 50 Cycle, 1 Phase properly grounded
electrical receptacle. The power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding
spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufactures responsibility and could result
in serious injury.
The circuit must be protected with a 15 or 20 amp fuse or breaker. The use of extension cords is not recommended with this unit.
1
OPERATION
Initial Start Up
After satisfying the installation requirements, the freezer is ready to operate. The unit will start when the power cord is connected to
a live electrical receptacle. If the Compressor and Condenser Fan are not running when the unit is initially connected to power,
check to make sure that the Temperature Control is not set to the ‘off’ position. Allow the unit to run a minimum of two (2) hours
before loading it with product.
Temperature Control
The Temperature Control is located on the front panel of the cabinet and is factory set to maintain an average cabinet temperature
of approximately 0 Degrees Celsius. To obtain colder temperatures, press and hold the set button until the set point value flashes.
Use the up or down arrow buttons to change the value and then press the set button again. Allow the unit a minimum of one hour to
respond to a control setting adjustment.
Defrost
The SKMWF freezer is a manual defrost unit. The unit should be defrosted whenever the walls accumulate a frost bank that is 1/2
inch thick. To defrost the unit, first remove the product and the covers from the unit then either turn the Temperature Control to the
‘off’ position or disconnect the power cord from the electrical receptacle. After the frost has melted or come loose from the cabinet
walls, wipe out the cabinet interior with a sponge or position the unit over a floor drain and remove the drain plug allowing the
condensate to drain out of the cabinet and into the floor drain. Do not attempt to scrape or chisel off the frost as you could do
irreparable damage to the cabinet.
MAINTENANCE
Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of
the appliance.
Cabinet Surfaces
The interior and exterior surfaces are stainless steel and should be cleaned periodically with a solution of warm water and a mild
soap, rinsed with clean water and wiped dry. A good stainless steel cleaner can also be used. Should a surface become stained or
discolored, do not attempt to clean with an abrasive cleaner or scouring pad. Use a soft cleaner and rub with the grain of the metal
to avoid scratching the surface. Always rinse and dry afterwards. Do not use chlorinated cleaners on the stainless steel.
Condenser
Periodically, dust accumulated on the Condenser should be removed. First, disconnect the unit from the power supply. Remove
the service panel to expose the Condenser. Remove the accumulated dust by vacuuming or blowing air through the coil. This
procedure will save on Compressor running time (electrical costs) and also extend the life of the Compressor.
Casters
Retighten the Casters to the base of the unit regularly to prevent damage to the base of the cabinet.
MODEL SERIAL NO. DATE INSTALLED
2
MANUAL TECNICO
CONGELADOR PORTATIL SILVER KING
MODELOS SKMWF34, SKMWF44, SKMWF50
Gracias por comprar la maquinaria de servicios de alimentación Silver King. Nuestro objetivo es otorgar a nuestros clientes la
mejor maquinaria de la industria actual. Sírvase leer este manual y la información acerca de la garantía que lo acompaña antes de
poner en funcionamiento su nueva unidad Silver King. Asegúrese de completar y enviar por correo la tarjeta de garantía dentro de
los 10 días posteriores a la compra a fin de ratificar su garantía.
INSPECCIONE LA UNIDAD EN BUSCA DE DAÑOS Y DESEMBALE
Cuando reciba su nueva unidad Silver King, desembálela inmediatamente y controle que no haya sufrido daños durante el
transporte siguiendo las instrucciones impresas en la parte externa del envase. Si encuentra daños, infórmelo a la empresa
responsable del transporte y presente inmediatamente un reclamo ante cualquier prueba de maltrato. Si presenta un reclamo,
conserve todo el material de embalaje.
INSTALACION
El exterior del gabinete de acero inoxidable ha sido protegido por una cubierta de plástico en la fabricación y envío. Esta cubierta
puede ser retirada antes de la instalación. Una vez retirada la cubierta, lave las superficies internas y externas utilizando una
solución de agua jabonosa y tibia y una esponja o paño, enjuague con agua limpia y seque.
Rueditas
La unidad trae rueditas instaladas. Asegúrese que las rueditas estén instaladas firmemente en la base del gabinete para evitar
daños en la base.
Ubicación
Al elegir una ubicación para su nuevo congelador, debe tener en cuenta la conveniencia y facilidad de acceso, pero debe seguir las
siguientes pautas de instalación;
• La unidad debe estar instalada derecha.
• Deje un espacio de al menos 15 centímetros (6 pulgadas) en ambos extremos para permitir una circulación de aire adecuada a
través de los paneles de ventilación. La unidad debe tener un espacio abierto en la parte superior para permitir el acceso a los
productos.
• Evite colocar el refrigerador cerca de un horno, elemento calefactor o fuente de aire caliente, que pueda afectar el
funcionamiento de la unidad.
Conexiones Eléctricas
Asegúrese de revisar la placa de datos ubicada en el revestimiento del gabinete para ver el voltaje requerido antes de conectar la
unidad a una fuente eléctrica. Las especificaciones en la placa de datos sustituyen cualquier discusión posterior.
El congelador estándar está equipado con un cable de transmisión de energía de 2,43 metros (8 pies) que requiere un receptor
eléctrico con descarga a tierra de 230 Voltios, 50 Ciclos, 1 Fase. El cable de transmisión de energía incluye un enchufe de tres
patas para la descarga a tierra. Cualquier intento de cortar la pata de descarga a tierra o de conectar el enchufe a un adaptador
que no posea descarga a tierra anulará la garantía, eximirá a los fabricantes de responsabilidad y podría resultar en un serio daño.
El circuito debe estar protegido con un fusible o interruptor de 15 o 20 amperios. La unidad debe estar aislada en un circuito y no
debe conectarse a una prolongación del cable.