Sigma Glow-01 Installation Instructions Manual

Installation Instruction
Parking Garage Fixture
PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
1. To prevent personal injury or product damage only licensed electricians should install.
2. To avoid electrical shock or component damage, disconnect power before attempting installation or servicing.
3. This product must be installed in accordance with the national electric code (NEC) and all applicable federal, state and local electric codes and safety standards.
4. Disconnect product and allow cooling prior to any further steps.
5. Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage and/or product malfunction.
6. To prevent product malfunction and/or electrical shock this product must be properly grounded.
7. This luminaire is designed to operate in ambient temperatures ranging from -25°C to 40°C and to be horizontally mounted with the LED board facing downward.
Surface-mounted with J-BOX
1
. Loosen the screw on the side of the housing and pull out the connecting plate
2. Fix the connecting plate
onto the ceiling and put the wire through center hole
Pendent Installation with 3/4 inch conduit
. Loosen the screw on the side of the
1
housing and pull out the connecting plate,
2. connect the wires as following shows,
3. Buckle the connecting plate
into the clips and connect the wires as following shows
Black
White
Green/Yellow
Line
Neutral
Ground
3. Screw the lamp and conduit pole
together tightly
4. Slide lamp back into the
connecting plate and fix the screw that is removed in step one
Black
White
Green/Yellow
Line
Neutral
Ground
Surface-mounted with side-wiring
1
. Remove the lens and metal cover in
the middle
2, Cut off wires coming out of 3/4” hole
and seal the hole with provided plug. Drill 4 holes on four corners and fix it onto the ceiling with suitable screws
4. Relocate the wire from 3/4” hole to 1/2” hole and connect
to the conduit as following
3. Remove 1/2” plug against the
direction you intend to connect the conduit
5. Put back the middle metal cover and lens, make sure no
wires are pinched or exposed during the whole process
Sensor set-up
1. Remove the lens
Black
White
Green/Yellow
Line
Neutral
Ground
2. Adjust the combination of DIP switches
with appropriate tool according to needs
3. Put back the lens and check the
function of sensor
Loading...