Siglent SSA3000X User Manual

68
SSA3000X Spectrum Analyzer
User Manual
UM0703X-E03B
Terms in this Manual. These terms may appear in this manual:
WARNING
Warning statements indicate the conditions or practices that could result in injury or loss of life.
CAUTION
Caution statements indicate the conditions or practices that could result in damage to this product or other property.
Limites en ce manuel. Ces limites peuvent apparaître en ce manuel :
Les rapports
d'avertissement D'AVERTISSEMENT indiquent les conditions ou les
pratiques qui pourraient avoir comme conséquence les dommages ou la
perte de la ie.
Les rapports
d'attention d'ATTENTION indiquent les conditions ou les pratiques qui pourraient avoir comme consequenceles dommages à ce produit ou à
toute autre propriété.
The Plug
The Fuse
NO.
Description
NO.
Description
1
User Graphical Interface
2
Menu Control Keys
3
Function Keys
4
Knob
5
Arrow Keys
6
RF Input
7
Numeric Keyboard
8
TG Output
9
Earphone interface
10
USB Host
11
Power Switch
Control Keys
Description
Frequency
Set the parameters of frequency, and Peak→CF, CF→Step.
Span
Set the parameters of span, and X-scale (Log-Linear) setup.
Amplitude
Set the parameters of amplitude, including Ref Level, Attenuator, Preamp, etc; and Correction setup.
Auto Tune
Scan the full span rapidly and move the biggest signal to center freq, and automatically sets the optimal parameters according to the signal.
Control Keys
Description
BW
Set the parameters of RBW and VBW, Average Type (Log power, Power, Voltage), and Filter Type (-3 dB Gauss\ -6 dB EMI).
Trace
Select Trace, Trace setup and Trace math.
Sweep
Set the parameters of sweep, and EMI QPD Dwell Time.
Detect
Select the Detector type for each trace independently.
Trigger
Select triggers in Free Trigger, Video Trigger and External Trigger.
Limit
Set the Pass\Fail Limit.
TG
Set the parameters of tracking generator. Including TG Level, TG level offset, Normalization setup. The backlight LED is on when TG source is on.
Demod
Set the demodulation parameters of the AM and FM for audio listening
Marker Keys
Description
Marker
Set the Markers and Marker Table
Marker->
Set other system parameters on the basis of the current marker value.
Marker Fn
Special functions of the marker such as noise marker, N dB bandwidth measurement and frequency counter.
Peak
Search for the peak signal, peak search configuration and peak table.
Meas Keys
Description
Meas
In spectrum analyzer mode, select the Advanced Measurement function In non spectrum analyzer mode, select corresponding settings.
Meas Setup
Set the measurement parameters.
System Keys
Description
System
Set the system parameters
Mode
Select the working modes.
Display
Set the display parameters.
File
Use the file system and files
Shortcut Keys
Description
Preset
Sets the system to certain status
Couple
Set the parameters of some functions between auto and manual.
Help
Turn on the built-in help
Save
Save Shortcut Key
CAUTION
Protect your hearing. Please turn the volume down to zero before using the earphone. Gradually turn the volume up to a comfortable level after putting in the earphone..
CAUTION
To avoid damage to the tracking generator, the reverse DC voltage cannot exceed 50 V
CAUTION
To avoid damage to the instrument, for the signal input from the RF input terminal, the DC voltage component and the maximum continuous power of the AC (RF) signal component cannot exceed 50 V and +30 dBm respectively.
NO.
Name
Description
1
SIGLENT
Logo of SIGLENT
2
Ref
Reference level
3
UNCAL
When the sweep time less than the auto couple time, the measure result may be inaccuracy, then appear UNCAL
4
Active function area
Current parameter and its value
5
EXT REF
Ext 10 MHz reference clock detected indicator
6
Att
Attenuator Value
7
Day and time
System time
8, 9, 11
Maker parameter
8:current active marker; 9:current marker frequency value; 11:current marker amplitude value;
10
Auto Tune
Automatically sets the optimal parameters
12
USB storage device identification
The identification is displayed when a USB disk is inserted 13
Menu title
Function of the current menu.
14
Menu items
Menu items of the current function
15
Operation status
Local is local mode, Remote is remote mode, Upgrade
means the instrument is upgrading
16
Sweep time
Sweep time
17
Span/Stop Frequency
The frequency range of the current sweep
18
Sweep progress bar
Sweep progress bar
19
Pass/Fail status
Pass/Fail status
20
VBW
Video bandwidth
21
Spectrum trace
Spectrum trace
22
RBW
Resolution bandwidth
23
Center/Start frequency
The frequency range of the current sweep
24, 25, 26, 27
Trace A\B\C\D status
Trace type: C&W: Clear Write MaxH: Max Hold MinH: Min Hold View: View AVG: Video average.
Detect type: P-PK: Positive peak N-PK: Positive peak Samp: Sample Norm: Normal AVG: average Q-PK: Quasi-peak
28
AM or FM
AM or FM identification
29
PA
Enable or disable Preamplifier
30
FFT
Sweep mode is FFT
31
Single or Continue
Sweep mode single or continue
32
Average type
Log power, Power, Voltage
33
Trigger type
Free, Video, External trigger
34, 35
Ref offset
34:Ref offset identification; 35:Ref offset value
36
Scale/Div
Scale value
37
Scale type
Logarithm or linearity
startstopspan
stopstartcenter
fff
)/2f(ff
=
+=
span
f
Parameter
Explanation
Default
Full Span/2
Range
Zero Span, 0 Hz ~ Full Span Nonzero Span, 50 Hz ~ (Full Span -50Hz)
Unit
GHz\MHz\kHz\Hz
Knob Step
Span>0, step=Span/200 Span=0, step=RBW/100 Min 1 Hz
Direction Key Step
Freq step
Related to
Start Freq, Stop Freq
Parameter
Explanation
Default
0 GHz
Range
Zero Span, 0 Hz ~ Full Span Nonzero Span, 0 Hz ~ (Full Span-100Hz)
Unit
GHz\MHz\kHz\Hz
Knob Step
Span>0, step=Span/200 Span=0, step=RBW/100 Min 1 Hz
Direction Key Step
Freq step
Related to
Center Freq, Span
Parameter
Explanation
Default
Full Span
Range
Zero Span: 0 Hz ~ Full Span Nonzero Span: 100 Hz ~ Full Span
Unit
GHz, MHz, kHz, Hz
Knob Step
Span>0, step=Span/200 Span=0, step=RBW/100 Min 1 Hz
Direction Key Step
Freq step
Related to
Center Freq, Span
Parameter
Explanation
Default
Full Span/10
Range
1Hz ~ Full Span
Unit
GHz, MHz, kHz, Hz
Knob Step
Span>0, Step=Span/200 Span=0, Step=100 min 1 Hz
Direction Key Step
1-2-5 sequence step
Relation
RBW, Span and related parameters
Parameter
Explanation
Default
Maximum bandwidth
Range
0 Hz~ 3.2 GHz
Unit
GHz, MHz, kHz, Hz
Knob Step
Span/200, Min = 1 Hz
Direction Key Step
In 1-2-5 sequence
Related to
Start Freq, Stop Freq, Freq Step, RBW, Sweep time
Parameter
Explanation
Default
0 dBm
Range
-100 dBm ~ 30 dBm
Unit
dBm, dBmV, dBuV, V, W
Knob Step
In Log scale mode, step = Scale/10 In Lin scale mode, step = 0.1 dB
Direction Key Step
In Log scale mode, step = Scale In Lin scale mode, step = 1 dB
Related to
Attenuator, Preamp, Ref Offset
Parameter
Explanation
Default
20 dB
Range
0 ~ 51 dB
Unit
dB
Knob Step
1 dB
Direction Key Step
5 dB
Related to
Preamp, Ref level
Parameter
Explanation
Default
10 dB
Range
1 dB ~ 20 dB
Unit
dB
Knob Step
1 dB
Direction Key Step
1-2-5 sequence
Related to
Scale Type
Parameter
Explanation
Default
0dB
Range
-100dB ~ 100dB
Unit
dB
Knob Step
1dB
Direction Key Step
10dB
Function
Explanation
Correction
Select the correction factor on or off.
Add Point
Add a point into correction table.
Point Num
Select a point to edit by point num.
Frequency
Edit the frequency value for the current selected point.
Amplitude
Edit the amplitude value for the current selected point.
Del Point
Delete the selected correction point.
Del All
Clear all data of the correction table.
Save/Load
Save or load correction data. You can save the current correction data
Parameter
Explanation
Default
1MHz
Range
10Hz ~ 1MHz
Unit
MHz, kHz, Hz
Knob Step
in 1, 3, 10 sequence
Direction Key Step
in 1, 3, 10 sequence
Relation
Span, RBW, VBW, Sweep Time
Parameter
Explanation
Default
1MHz
Range
1Hz ~ 3MHz
Unit
MHz, kHz, Hz
Knob Step
in 1, 3, 10 sequence
Direction Key Step
in 1, 3, 10 sequence
Relation
RBW, V/R Ratio, Sweep Time
Parameter
Explanation
Default
1 Range
0.001 ~ 1000
Unit
N/A
Knob Step
in 1, 3, 10 sequence
Direction Key Step
in 1, 3, 10 sequence
Relation
RBW,VBW
Parameter
Explanation
Default
100
Range
1 ~ 999
Unit N/A
Knob Step
1 Direction Key Step
5
Parameter
Explanation
Default
N/A
Range
900 us ~ 3 ksQuasi Peak900 us ~ 30 ks
Unit
ks, s, ms, us
Knob Step
Sweep time/100, min =1 ms
Direction Key Step
in 1,3 sequence
Parameter
Explanation
Default
1 Range
1 ~ 9999
Unit
N/A
Knob Step
1 Direction Key Step
1
Parameter
Explanation
Default
50 ms
Range
0 s ~ 10 s
Unit
ks, s, ms, us
Knob Step
N/A
Direction Key Step
N/A
Parameter
Explanation
Default
0 dBm
Range
-300 dBm ~ 50 dBm
Unit
dBm
Knob Step
1 dB
Direction Key Step
10 dB
Function
Explanation
Type
Select the desired limit line (upper or lower) for editing
Mode
Select the line or point for editing. Set the number of the point to be edited if you selected the point type. The range from 1 to 100
Add point
Add a new point for editing.
X-axis
Edit the X-axis value (frequency or time) of the current point. If the X-axis unit is frequency and the Ref Freq is enabled, edit the frequency difference between the frequency of the current point and the center frequency.
Amplitude
Edit the amplitude of the current point or line. If the Ref AMPT is enabled, edit the amplitude difference between the amplitude of the current point and the reference level.
Del Point
Delete the point you are editing.
Del All
Delete all point.
Save/Recall
Save or load the limit file.
Function
Explanation
Type
Select the desired limit line (upper or lower) for editing
Mode
Select the line or point for editing. Set the number of the point to be edited if you selected the point type. The range from 1 to 100
Add point
Add a new point for editing.
X-axis
Edit the X-axis value (frequency or time) of the current point. If the X-axis unit is frequency and the Ref Freq is enabled, edit the frequency difference between the frequency of the current point and the center frequency.
Amplitude
Edit the amplitude of the current point or line. If the Ref AMPT is enabled, edit the amplitude difference between the amplitude of the current point and the reference level.
Del Point
Delete the point you are editing.
Del All
Delete all point.
Save/Recall
Save or load the limit file.
Parameter
Explanation
Default
0 dB
Range
-20 dBm ~ 0 dBm
Unit
dBm
Knob Step
1 dB
Direction Key Step
10 dB
Parameter
Explanation
Default
0 dB
Range
-200 dB ~ 200 dB
Unit
dB
Knob Step
1 dB
Direction Key Step
10 dB
Default
reference plane
Normalized
reference plane
Parameter
Explanation
Default
0 dB
Range
-200 dB ~ 200 dB
Unit
dB
Knob Step
1 dB
Direction Key Step
10 dB
Parameter
Explanation
Default
100%
Range
0 ~ 100%
Unit
100%
Knob Step
1%
Direction Key Step
10%
Parameter
Explanation
Default
6 Range
0 ~ 10
Unit
N/A
Knob Step
1 Direction Key Step
1
Parameter
Explanation
Default
5 s
Range
5 ms ~ 1000 s
Unit
ks, s, ms
Knob Step
0 ms ~ 100 ms, step=1 ms 100 ms ~ 1 s, step =10 ms
Direction Key Step
1-2-5 step
Parameter
Explanation
Default
Center Frequency
Range
0 ~ Full Span
Unit
Readout = Frequency , units available are GHz, MHz, kHz, Hz Readout = Time, units available are s, ms, us, ns, ps
Knob Step
Readout = Frequency (or Period), Step = Span/(Sweep Points - 1)
Direction Key Step
Readout = Frequency (or Period), Step = Span/10
Parameter
Explanation
Default
-3 dB
Range
-100 dB ~ 100 dB
Unit
dB
Knob Step
0.1 dB
Direction Key Step
1 dB
Parameter
Explanation
Default
-160 dBm
Range
-200 dBm ~ 200 dBm
Unit
dBm
Knob Step
1 dB
Direction Key Step
5 dB
Parameter
Explanation
Default
15 dB
Range
0 dB ~ 200 dB
Unit
dB
Knob Step
1 dB
Direction Key Step
5 dB
Parameter
Explanation
Default
2 MHz
Range
100 Hz ~ Span
Unit
GHz, MHz, kHz, Hz
Knob Step
Integration BW/100, the minimum is 1 Hz
Direction Key Step
In 1-1.5-2-3-5-7.5 sequence
Parameter
Default
Range
Unit
Knob Step
Direction Key Step
Parameter
Explanation
Default
2 MHz
Range
100 Hz ~ Sweep Span
Unit
GHz, MHz, kHz, Hz
Knob Step
Integration BW /100, the minimum is 1 Hz
Direction Key Step
In 1-1.5-2-3-5-7.5 Sequence
Parameter
Explanation
Default
2 MHz
Range
100 Hz ~ Sweep Span
Unit
GHz, MHz, kHz, Hz
Knob Step
Integration BW /100, the minimum is 1 Hz
Direction Key Step
In 1-1.5-2-3-5-7.5 Sequence
Parameter
Explanation
Default
2 MHz
Range
33 Hz ~ full span
Unit
GHz, MHz, kHz, Hz
Knob Step
Integration BW /100, the minimum is 1 Hz
Direction Key Step
In 1-1.5-2-3-5-7.5 Sequence
Parameter
Explanation
Default
1ms
Range
0 s ~ stop line
Unit
ks, s, ms, us, ns
Knob Step
Sweep time/751
Direction Key Step
In 1-1.5-2-3-5-7.5 Sequence
Parameter
Explanation
Default
24.032ms
Range
Start line ~ sweep time
Unit
ks, s, ms, us, ns
Knob Step
Sweep time /751
Direction Key Step
In 1-1.5-2-3-5-7.5 Sequence
Parameter
Explanation
Default
0 dBm
Range
REF Level + REF Offset – 10*Scale/Div ~ REF Level + REF Offset
Knob Step
1 dB
Direction Key Step
10 B
Parameter
Explanation
Default
30%
Range
0 ~ 100%
Unit
None
Knob Step
1%
Direction Key Step
1%
Parameter
Default
Frequency
Center Freq
1.6 GHz
Start Freq
0 Hz
Stop Freq
3.2 GHz
Freq Step
Auto
Span
Span
3.2 GHz
X Scale\
Linear
Amplitude
Ref Level
0 dBm
Attenuator
Auto, 20 dB
Preamp
Off
Units
dBm
Scale/Div
10 dB
Scale Type
Log
Ref Offset
0 dBm
Corrections
Off
BW
RBW
Auto, 1 MHz
VBW
Auto, 1 MHz
VBW/RBW
1
Avg Type
Log Pwr
Filter
Gauss
Sweep
Sweep Time
Auto
Sweep Rule
Speed
Sweep
Continue
Sweep Mode
Auto
Numbers
1
Trig
Trigger Type
Free Run
Video Trigger
0 dBm
External Trigger
Rising
TG
TG
Off
TG Level
-20 dBm
TG Lvl Offset
0 dB
Normalize
Off
Norm Ref Lvl
0 dB
Norm Ref Pos
100%
Ref Trace
Blank
Trace
Select Trace
A
Trace Type of Trace A
Clear Write
Avg Times
100
Variable X
A
Variable Y
B
Constant
0 dB
Output Z
C
Math Type
Off
Detect
Select Trace
A
Detect Type of Trace A
Pos Peak
Limit
Limit1
Off, Limit Upper, 0 dBm
Limit2
Off, Limit Lower, -100 dBm
Test
Stop
Fail to stop
Off
Buzzer
Off
X Axis
Freq
Demod
Demod Mode
Close
Earphone
Off
Volume
6
Demod Time
5.00 s
Marker
Select Marker
1
Select Trace
A
Marker Type
Normal
Delta Pair
Delta
Relative To
Off
Marker Table
Off
Marker Fn
Select Marker
1
Marker Fn
Off
N dB BW
-3 dB
Read Out
Frequency
Peak
Cont Peak
Off
Peak Table
Off
Peak Threshold
-160 dBm
Peak Excursion
15 dB
Peak Type
Max
Mode
Mode
Spec Analyzer
Measure
Meas Type
Off
Measure Setup
Channel Power
Center Freq
1.6 GHz
Integration BW
2 MHz
Span
3.2 GHz
ACPR
Center Freq
1.6 GHz
Main Channel
1 MHz
Adjacent Chn
1 MHz
Adj Chn Space
3 MHz
Occupied BW
Method
%
dBc
26 % 99
T-Power
Center Freq
1.6 GHz
Start Line
0 s
Stop Line
20 ms
System**
Language
English
Power On
Def
Preset
Def
IP Config
DPCH
Auto Cal
Close
Date & Time
On
Set Format
ymd
Display**
Display Line
Off, 0 dBm
Grid Brightness
30%
Screen Text
On
Screenshot
Inverse
Loading...