SIGLENT SPD3303X, SPD3303X-E Quick Start Manual

Quick Start
SPD3303X/3303X-E Programmable DC Power Supply
2015 SIGLENT TECHNOLOGIES CO., LTD
SIGLENT
SPD3000X Quick Start I
Copyright and Statement
Copyright
SIGLENT TECHNOLOGIES CO., LTD. All rights reserved.
Trademark Information
SIGLENT is registered trademark of SIGLENT TECHNOLOGIES CO., LTD.
Statement
SIGLENT products are protected by patent laws in and outside of the P.R.
China.
SIGLENT reserves the rights to change the specification and price.
Information in this publication replaces all previous corresponding
published material.
Contents in this manual are not allowed to be copied, extracted or
translated in any form or by any means without SIGLENT’s permission.
SIGLENT
II SPD3000X QuickStart
General Safety Summary
Please review the following safety precautions carefully to avoid personal injury or damage to this product or any product connected to it. To prevent potential danger, please use the instrument as specified.
Use proper power cord
Only the power cord designed for the instrument and authorized by local country could be used.
Power supply
AC Input Voltages: 100V/110V/220V/230V ±10%, 50/60Hz.
Use proper fuse
The fuse types: 100V/110V: T6.3A/250V; 220V/230V: T3.15A/250V; Make sure to use the correct type of fuse before turning on the instrument. Do not connect the power cord before replacing the fuse. Find out the reason why the fuse burned out before replacing the fuse.
Ground the instrument
The instrument is grounded through the protective terra conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to the earth. Make sure that the instrument is properly grounded before any inputs or outputs.
Observe all terminal ratings
To avoid fire or electric shock, please observe all ratings and symbols on the instrument. Read this guide carefully to know more details about the ratings before connection.
Keep proper ventilation
Inadequate ventilation may cause an increase of temperature,, which will lead
to further damage. Please keep proper ventilation and check the fan and air-vents regularly when using the instrument.
Operate condition
Location: indoor, no strong light, almost no Interfering pollution; Comparative humidity: <80% Altitude: <2000m Temperature: 0 to 40
SIGLENT
SPD3000X Quick Start III
Do not operate in an explosive atmosphere
To avoid personal injury or damage to instrument, please do not operate in an explosive atmosphere.
Keep surface of the product clean and dry
To avoid dust or moisture in the air influence the performance of the instrument , please keep surface of the product clean and dry.
SIGLENT
IV SPD3000X QuickStart
Safety Terms and Symbols
Terms may appear on the product:
DANGER: Indicates direct injury or hazard that may happen. WARNING: Indicates potential injury or hazard that may happen.
CAUTION: Indicates potential damage to the instrument or other property that
may happen.
Symbols may appear on the product:
Hazardous Protective Warning Earth Power
Voltage Earth Ground Ground Switch
SIGLENT
SPD3000X Quick Start V
SPD3303X/3303X-E Brief Introduction
SPD3303X/3303X-E Programmable DC Power Supply is convenient, flexible and multi-function. It has three independent outputs, two sets of adjustable voltage value and a fixed set of selectable voltage value of 2.5V, 3.3V, and 5V, and it also provides output short circuit and overload protection at the same time.
Main features of SPD3303X/3303X-E
4.3” TFT color LCD display with content of 16M;  Three independent outputs, two of which are adjustable, and the total
power up to 195W;
Four kinds of input voltage values includes 100V, 110V, 220V and 230V to
satisfy different requirements;
Function of storage and call setting parameters; Function of timing output ; Function of waveform display, Real-time display of voltage or current
waveforms with digital display of voltage, current and power values
Start up screen protective procedure every fixed interval(30 minutes) Perfect PC software to realize the real-time control through USBTMC and
LAN..
SIGLENT
VI SPD3000X QuickStart
Content
Copyright and Statement .................................................................................. I
General Safety Summary ................................................................................. II
Safety Terms and Symbols ............................................................................ IV
SPD3303X/3303X-E Brief Introduction ........................................................... V
Chapter 1 Start Guide ...................................................................................... 1
General Inspection ................................................................................................... 2
Safety Considerations ............................................................................................. 3
The front panel .......................................................................................................... 4
User interface ............................................................................................................ 7
The rear panel ........................................................................................................... 8
Output check ............................................................................................................. 9
Chapter 2 Control panel operation ................................................................. 10
2.1 Output summary .............................................................................................. 11
2.2 CH1/CH2 Independent Output ..................................................................... 12
2.3 CH3 Independent mode ................................................................................. 13
2.4 CH1/CH2 Series mode ................................................................................... 14
2.5 CH1/CH2 Parallel mode................................................................................. 15
2.6 LAN setting ....................................................................................................... 16
2.7 Save and Recall ............................................................................................... 17
2.8 Timer ................................................................................................................... 18
2.9 Waveform display ............................................................................................ 21
2.10 Version information ....................................................................................... 22
2.11 Upgrade firmware .......................................................................................... 23
Chapter 3 Remote control .............................................................................. 26
3.1 Syntax Conventions ........................................................................................ 27
3.2 Command list.................................................................................................... 28
3.3 Command description .................................................................................... 29
Chapter 4 Troubleshooting ............................................................................. 36
Chapter 5 Service and Support ...................................................................... 37
Maintain summary .................................................................................................. 37
Contact SIGLENT ................................................................................................... 37
SIGLENT
SPD3000X QuickStart 1
Chapter 1 Start Guide
In this chapter, we mainly introduce the panel and display Interface of SPD3303X/3303X-E, as well as the new machine inspection and attentions at first use. Reading this chapter will give you a quick understanding on operation. Brief introduction:
General Inspection The front panel The rear panel User interface The rear panel Output check
SIGLENT
2 SPD3000X QuickStart
General Inspection
Please check the instrument according to the following steps.
1. Inspect the shipping container.
Keep the damaged shipping container or cushioning material until the contents of the shipment have been completely checked and the instrument has passed both electrical and mechanical tests. The consigner or carrier will be responsible for damages to the instrument resulting from shipment. SIGLENT would not provide free maintenance or replacement.
2. Inspect the instrument.
If there are instruments found damaged, defective or failure in electrical and mechanical tests, please contact SIGLENT.
3. Check the accessories.
Please check the accessories according to the packing list. If the accessories are incomplete or damaged, please contact SIGLENT.
SIGLENT
SPD3000X QuickStart 3
Safety Considerations
To ensure that the instrument can work normally, please conduct necessary inspection before using the SPD3303X/3303X-E
Input Power Requirement
The SPD3303X/3303X-E allows a 50Hz/60Hz frequency, and four levels of AC power: 100V/120V/220V/230V. You can select wanted power voltage with the “DIP Switch” at the rear panel according to the actual demand.
Warning
To switch to the wanted power voltage, please disconnect the power
cord first.
Electrical Check
Please use the power cord provided as accessory and connects the instrument to AC power. Check the power as the following steps.
1. Connect the power supply
Warning
To avoid electric shock, please make sure that the instrument is
grounded correctly.
2. Turn on the power switch Press the button POWER to enter boot interface, and system return to the default settings after a while.
SIGLENT
4 SPD3000X QuickStart
The front panel
NO.
Description
NO.
Description
1
Logo
9
CH3 DIP Switch
2
Display Area
10
Power Switch
3
Model
11
CH1 Output Terminal
4
System parameter configuration button
12
Ground Terminal
5
Multi-function knob
13
CH2 Output Terminal
6
Fine Adjust button
14
CV/CC indicator light
7
Right/Left Direction button
15
CH3 Output Terminal
8
Channel Control button
6
7
8
9
10 ○11 ○12 ○13 ○14 ○15
1 ○2 ○3 ○4 ○5
SIGLENT
SPD3000X QuickStart 5
Buttons for setting parameters
Press the button to turn on/off the waveform display interface;
Press the button to set series mode of CH1/CH2, and the logo
displays at the same time;
Press the button to set parallel mode of CH1/CH2, and the logo
displays at the same time;
Press the button to enter the LAN setting and storage function
interface
Press the button to enter timer setting interface
Press the button longer to turn on/off the keylock function and
shorter to turn to system information interface
Buttons for controlling the channel
Press the button to turn on/off all the channels;
Press the button to select CH1 as the current channel;
Press the button to select CH2 as the current channel;
Press the button to turn on/off the output of current channel;
Press the button to turn on/off the CH3 output
SIGLENT
6 SPD3000X QuickStart
Other buttons
Select the digit position by moving the cursor around
Right/Left Direction button. Press the button to move the cursor around
The output terminal on front panel
The output terminals of CH1, CH2 and CH3 include positive terminal and negative terminal, and a common ground for CH1 and CH2 additional. Each channel has its own logo. The operation details are introduced in the follow-up control panel operation”.
Loading...