SIGLENT SPD3303S, SPD3303D Quick Start Manual

Quick Start
SPD3303S/3303D Programmable DC Power Supply
2013 SIGLENT TECHNOLOGIES CO., LTD
SIGLENT
SPD3303S/3303D Quick Start I
Copyright Information
1. SIGLENT TECHNOLOGIES CO., LTD. All Rights Reserved.
2. Information in this publication replaces all previous
corresponding material.
3. SIGLENT reserves the right to change the specifications and
price of the product.
4. Any way of copying, extracting and translating the content of the
manual is not allowed without permission of SIGLENT.
Note:
SIGLENT is the registered trademark of SIGLENT
TECHNOLOGIES CO., LTD.
SIGLENT
II SPD3303S/3303D Quick Start
General Safety Summary
Please review the following safety precautions carefully to avoid
personal injury or damage to this product or any product connected
to it. To prevent potential danger, please use the instrument as
specified.
Use proper power cord
Only the power cord designed for the instrument and authorized by
local country could be used.
Power supply
AC Input Voltages: 100V/110V/220V/230V ±10%, 50/60Hz.
Use proper fuse
The fuse types: 100V/110V: T6.3A/250V; 220V/230V:
T3.15A/250V;
Make sure to use the correct type of fuse before turning on the
instrument.
Do not connect the power cord before replacing the fuse.
Find out the reason why the fuse burned out before replacing the
fuse.
Ground the instrument
The instrument is grounded through the protective terra conductor
of the power cord. To avoid electric shock, the grounding conductor
must be connected to the earth. Make sure that the instrument is
properly grounded before any inputs or outputs.
SIGLENT
SPD3303S/3303D Quick Start III
Observe all terminal ratings
To avoid fire or electric shock, please observe all ratings and
symbols on the instrument. Read this guide carefully to know more
details about the ratings before connection.
Keep proper ventilation
Inadequate ventilation may cause an increase of temperature,,
which will lead to further damage. Please keep proper ventilation
and check the fan and air-vents regularly when using the
instrument.
Operate condition
Location: indoor, no strong light, almost no Interfering pollution;
Comparative humidity: <80%
Altitude: <2000m
Temperature: 0 to 40
Do not operate in an explosive atmosphere
To avoid personal injury or damage to instrument, please do not
operate in an explosive atmosphere.
Keep surface of the product clean and dry
To avoid dust or moisture in the air influence the performance of the
instrument , please keep surface of the product clean and dry.
SIGLENT
IV SPD3303S/3303D Quick Start
Safety Terms and Symbols
Terms may appear on the product:
DANGER: Indicates direct injury or hazard that may happen.
WARNING: Indicates potential injury or hazard that may happen.
CAUTION: Indicates potential damage to the instrument or other
property that may happen.
Symbols may appear on the product:
Hazardous Protective Warning Earth Power
Vlotage Earth Ground Ground Switch
SIGLENT
SPD3303S/3303D Quick Start V
SPD3303S/3303D Brief Introduction
SPD3303S/3303D Programmable DC Power Supply is convenient,
flexible and multi-function. It has three independent outputs, two
sets of adjustable voltage value and a fixed set of selectable
voltage value of 2.5V, 3.3V, and 5V ,and it also provides output
short circuit and overload protection at the same time.
Main features of SPD3303S/3303D
4.3” TFT color LCD display with content of 16M;
Three independent outputs, two of which are adjustable, and the total power
up to 195W;
Four kinds of input voltage values includes 100V, 110V, 220V and 230V to
satisfy different requirements;
Function of storage and call setting parameters;
Function of timing output ;
Function of waveform display, Real-time display of voltage or current
waveforms with digital display of voltage, current and power values
Start up screen protective procedure every fixed interval(30 minutes)
Perfect PC software to realize the real-time control through USBTMC.
SIGLENT
VI SPD3303S/3303D Quick Start
Content
General Safety Summary ................................................................ II
SPD3303S/3303D Brief Introduction...............................................V
Chapter 1 Quick Start ...................................................................... 1
General Inspection .....................................................................1
Safety Considerations ................................................................2
The front panel ...........................................................................3
The rear panel ............................................................................7
Output check ..............................................................................8
Chapter 2 Control panel operation .................................................. 9
2.1 Output summary.................................................................10
2.2 CH1/CH2 Independent Output........................................... 11
2.3 CH3 Independent mode.....................................................12
2.4 CH1/CH2 Series mode ......................................................13
2.5 CH1/CH2 Parallel mode.....................................................15
2.7 Timer ..................................................................................18
2.9 Version information ............................................................21
2.10 Upgrade firmware.............................................................22
Chapter 3 Remote control ............................................................. 25
3.1 Command list .....................................................................25
3.2 Command description ........................................................26
Chapter 4 Specification..................................................................32
Chapter 5 Troubleshooting ............................................................ 34
Contact SIGLENT ....................................................................35
SIGLENT
SPD3303S/3303D Quick Start 1
Chapter 1 Quick Start
In this chapter, we mainly introduce the panel and display of
SPD3303S/3303D, as well as the new machine inspection and
attentions at first use. Reading the following steps will give you a
quick understanding on operation.
General Inspection
1. Inspect the shipping container.
Keep the damaged shipping container or cushioning material
until the contents of the shipment have been completely
checked and the instrument has passed both electrical and
mechanical tests.
The consigner or carrier will be responsible for damages to the
instrument resulting from shipment. SIGLENT would not provide
free maintenance or replacement.
2. Inspect the instrument.
If there are instruments found damaged, defective or failure in
electrical and mechanical tests, please contact SIGLENT.
3. Check the accessories.
Please check the accessories according to the packing list. If the
accessories are incomplete or damaged, please contact your
SIGLENT sales representative.
SIGLENT
2 SPD3303S/3303D Quick Start
Safety Considerations
To ensure that the instrument can work normally, please conduct
necessary inspection before using the SPD3303S/3303D.
Input Power Requirement
The SPD3303S/3303D allows a 50Hz/60Hz frequency, and four
levels of AC power: 100V/120V/220V/230V. You can select wanted
power voltage with the “DIP Switch ” at the rear panel according to
the actual demand.
Warning
To switch to the wanted power voltage, please disconnect the
power cord first.
Electrical Check
Please use the power cord provided as accessory and connects
the instrument to AC power. Check the power as the following
steps.
1. Connect the power supply
Warning
To avoid electric shock, please make sure that the instrument is
grounded correctly.
2. Turn on the power switch
Press the button POWER to enter boot interface, and system
return to the default settings after a while.
SIGLENT
SPD3303S/3303D Quick Start 3
The front panel
NO. Description NO. Description
1 Logo 9 CH3 DIP Switch
2 Display Area 10 Power Switch
3 Model 11 CH1 Output Terminal
4
System parameter configuration button
12 Ground Terminal
5 Multi-function knob 13 CH2 Output Terminal
6 Fine Adjust button 14 CV/CC indicator light
7 Right/Left Direction button 15 CH3 Output Terminal
8 Channel Control button
6
7
8
9
10 ○11 ○12 ○13 ○14 ○15
1 ○2 ○3 ○4 ○5
SIGLENT
4 SPD3303S/3303D Quick Start
Instruction for buttons
Buttons for setting parameters
: Press the button to turn on/off the waveform display interface;
: Press the button to set series mode of CH1/CH2, and the logo
” displays at the same time;
:Press the butten to set parallel mode of CH1/CH2, and the logo
” displays at the same time;
:Press the butten to enter the storage function interface
:Press the butten to enter timer setting interface
: Press the button longer to lock it and shorter to turn to system
information interface.
Buttons for controlling the channel
: Press the button to turn on/off all the channels;
: Press the button to select CH1 as the current channel;
: Press the button to select CH2 as the current channel;
: Press the button to turn on/off the CH1 output;
: Press the button to turn on/off the CH3 output.
Other buttons
: Press the button to open the fine tuning function and change the
parameters with the minimum step;
: To move the cursor around.
WAVEDISP
SER
PARA
LOCK/VER
TIMER
RECALL/SAVE
CH3 ON/OFF
CH2
CH1
ALL ON/OFF
ON/OFF
FINE
SIGLENT
SPD3303S/3303D Quick Start 5
The output terminal on front panel
The output terminals of CH1CH2 and CH3 include positive
terminal and negative terminal, and a common ground for CH1 and
CH2 additional. Each channel has its own logo. The operation
details are introduced in the follow-up ” control panel operation”.
SIGLENT
6 SPD3303S/3303D Quick Start
User interface
1 Parallel/Series logo: The logo will be displayed when the corresponding
mode is on
2 Channel logo;
3 Operating mode logo: The corresponding logo will display when working in
CV or CC mode;
4 LOCK logo: It will display when the LOCK is turned on
5 USB logo: It will display when there is a USB connection;
6 Voltage value;
7 Current value;
8 Power value;
9 Timer lD: Timer state identification
10 Channel on/off logo;
10
6
7
8
1 ○2 ○3 ○4 ○5
○9
Loading...
+ 29 hidden pages