SIGLENT SDS1000CML series, SDS1000CNL series, SDS1000DL series, SDS1000CFL Series Quick Start Manual

Quick Start
SDS1000CML/CNL/DL Series Digital Oscilloscope
V1.1
2013 SIGLENT TECHNOLOGIES CO., LTD
SIGLENT
SDS1000CML/CNL/DL Quick Start I
Guaranty and Declaration
Copyright
SIGLENT TECHNOLOGIES CO., LTD. All Rights Reserved.
Trademark Information
SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES
CO., LTD
Declaration
SIGLENT products are protected by patent law in and outside of
P.R.C.
SIGLENT reserves the right to modify or change parts of or all
the specifications or pricing policies at company’s sole decision.
Information in this publication replaces all previously
corresponding material.
Any way of copying, extracting or translating the contents of this
manual is not allowed without the permission of SIGLENT.
SIGLENT will not be responsible for losses caused by either
incidental or consequential in connection with the furnishing, use or performance of this manual as well as any information contained.
Product Certification
SIGLENT guarantees this product conforms to the national and
industrial standards in china as well as the ISO9001: 2008 standard and the ISO14001: 2004 standard. Other international standard conformance certification is in progress.
SIGLENT
II SDS1000CML/CNL/DL Quick Start
Safety Requirement
General Safety Summary
Carefully read the following safety precautions to avoid personal injuries and prevent damage to the instrument and any products connected to it. To avoid potential hazards, please use the instrument as specified.
Only qualified technician should perform service procedures
To Avoid Fire or Personal Injuries
Use Proper Power Line
Use only the special power line of the instrument which is approved by local state.
Ground the Instrument
The instrument grounds through the protective terra conductor of the power line. To avoid electric shock, the ground conductor must be connected to the earth. Make sure the instrument is grounded correctly before connecting its input or output terminals.
Connect the Signal Wire Correctly
The potential of the signal wire is equal to the earth, so do not connect the signal wire to a high voltage. Do not touch the exposed contacts or components.
Look Over All Terminals’ Ratings
To avoid fire or electric shock, please look over all ratings and sign instruction of the instrument. Before connecting the instrument, please read the manual carefully to gain more information about the ratings.
SIGLENT
SDS1000CML/CNL/DL Quick Start III
Do not Operate with Suspected Failures
If you suspect that there is a damage of the instrument, please let a qualified service personnel check it.
Avoid Circuit or Components Exposed
Do not touch exposed contacts or components when the power is on.
Do not Operate in Wet/Damp Conditions
Do not Operate in an Explosive Atmosphere
Keep the Surface of the Instrument Clean and Dry
Safety Terms and Symbols
Terms on the product. These terms may appear on the product:
DANGER: Indicates direct injuries or hazards that may happen. WARNING: Indicates potential injuries or hazards that may happen. CAUTION: Indicates potential damages to the instrument or other
property that may happen.
Symbols on the product. These symbols may appear on the product:
Hazardous Protective Warning Earth Ground Power
Voltage Earth Ground Switch
SIGLENT
IV SDS1000CML/CNL/DL Quick Start
General Care and Cleaning
Care:
Do not store or leave the instrument in direct sunshine for long periods of time.
Notice:
To avoid damages to the instrument or probe, please do not
leave them in fog, liquid, or solvent.
Cleaning:
Please perform the following steps to clean the instrument and probe regularly according to its operating conditions.
1. Disconnect the instrument from all power sources, and then clean it with a soft wet cloth.
2. Clean the loose dust on the outside of the instrument and probe with a soft cloth. When cleaning the LCD, take care to avoid scarifying it.
Notice:
To avoid damages to the surface of the instrument and probe,
please do not use any corrosive liquid or chemical cleanser.
Make sure that the instrument is completely dry before
restarting it to avoid short circuits or personal injuries.
SIGLENT
SDS1000CML/CNL/DL Quick Start V
Contents
Guaranty and Declaration .................................................................................I
Safety Requirement .........................................................................................II
Safety Terms and Symbols .......................................................................III
General Care and Cleaning ..................................................................... IV
Quick start........................................................................................................1
General Inspection..................................................................................... 1
Appearance and Dimension ...................................................................... 2
Adjust the Supporting Legs........................................................................ 3
Connect to AC Power Supply ....................................................................4
Power-on Inspection ..................................................................................5
Connect the Probe.....................................................................................6
Function Inspection.................................................................................... 7
Probe Compensation .................................................................................8
The Rear Panel........................................................................................ 10
Function Introduction of Front Panel........................................................ 11
Vertical Control .................................................................................. 11
Horizontal Control..............................................................................13
Trigger Control...................................................................................14
RUN/STOP........................................................................................15
SINGLE .............................................................................................15
AUTO ................................................................................................15
Universal Knob ..................................................................................16
Function Menus.................................................................................17
DEFAULT SETUP..............................................................................18
HELP Information ..............................................................................18
PRINT................................................................................................18
User Interface .......................................................................................... 19
Using Security Lock .................................................................................22
Troubleshooting .............................................................................................23
Contact SIGLENT ..........................................................................................25
SIGLENT
SDS1000CML/CNL/DL Quick Start 1
Quick start
General Inspection
1. Inspect the shipping container.
Keep the damaged shipping container or cushioning material until the contents of the shipment have been completely checked and the instrument has passed both electrical and mechanical tests. The consigner or carrier will be responsible for damages to the instrument resulting from shipment. SIGLENT would not provide free maintenance or replacement.
2. Inspect the instrument.
If there are instruments found damaged, defective or failure in electrical and mechanical tests, please contact SIGLENT.
3. Check the accessories.
Please check the accessories according to the packing list. If the accessories are incomplete or damaged, please contact your SIGLENT sales representative.
SIGLENT
2 SDS1000CML/CNL/DL Quick Start
Appearance and Dimension
Figure 1 Front View
Figure 2 Side View
SIGLENT
SDS1000CML/CNL/DL Quick Start 3
Adjust the Supporting Legs
Adjust the supporting legs properly to use them as stands to tilt the oscilloscope upwards for stable placement as well as easier operation and observation of the instrument.
Figure 3 Adjust the Supporting Legs
SIGLENT
4 SDS1000CML/CNL/DL Quick Start
Connect to AC Power Supply
The oscilloscope accept 100240V, 45440Hz AC power supply. Please use the power cord provided as accessories to connect the instrument to the power source as shown in the figure below.
Note: In want of replacing the fuse, please return the instrument to
the factory that produced it to have it repaired by qualified service personnel authorized by SIGLENT.
Power socket