SIGLENT SDG1000 Series, SDG1010, SDG1005, SDG1025, SDG1020 Programming Manual

...
Programming Manual
SDG1000 Series Function/Arbitrary Waveform Generator
SDG1005/SDG1010/SDG1020/SDG1025/SDG1050
2012 SIGLENT Technologies Co., Ltd
SDG1000 Programming Manual
Copyright © SIGLENT Technologies Co., Ltd. All rights reserved. Contents in this Manual are not allowed to be copied, extracted and translated before being allowed by SIGLENT Company
SDG1000 Programming Manual
1.1. About Commands & Queries.................................................................................. 1
1.1.1. How they are listed? …………………………………………………………1
1.1.2. How they are described?................................................................................. 1
1.1.3. When can they be used?.................................................................................. 1
1.1.4. Command Notation......................................................................................... 2
1.2. Table of Commands & Queries……………………………………………………3
1.3. IEEE 488.2 Common Command Introduction…………………………………… 4
1.3.1 CHDR……………………………………………………………………….. 4
1.3.2. OPC…………………………………………………………………………. 5
1.3.3. IDN…………………………………………………………………………. 6
1.4. Output Command …………………………………………………………………7
1.5. Basic Wave Command ……………………………………………………………8
1.6. Modulate Wave Command ………………………………………………………11
1.7. Sweep Wave Command …………………………………………………………15
1.8. Burst Wave Command …………………………………………………………..18
1.9. Parameter Copy Command …………………………………………………… ..21
1.10. Arbitrary Wave Command ………………………………………………………22
1.11. Phase Command …………………………………………………………………24
1.12. Sync Command ………………………………………………………………….25
1.13. Configuration Command ………………………………………………………...26
1.14. Buzzer Command ………………………………………………………………..27
1.15. Screen Save Command…………………………………………………………. 28
1.16. Clock Source Command………………………………………………………... 29
1.17. Frequency Counter ………………………………………………………………30
1.18. Store list command ………………………………………………………………32
1.19. Get arbitrary wave data command ……………………………………………….34
1.20. Virtual key command……………………………………………………………. 36
1.21. Index ……………………………………………………………………………..37
1
SDG1000 Programming Manual
Introduction to the SCPI Language
1.1. About Commands & Queries
This section lists and describes the remote control commands and queries recognized by the instrument. All commands and queries can be executed in either local or remote state.
The description for each command or query, with syntax and other information, begins on a new page. The name (header) is given in both long and short form at the top of the page, and the subject is indicated as a command or query or both. Queries perform actions such as obtaining information, and are recognized by the question mark (?) following the header.
1.1.1. How they are listed?
The descriptions are listed in alphabetical order according to their short form.
1.1.2. How they are described?
In the descriptions themselves, a brief explanation of the function performed is given. This is followed by a presentation of the formal syntax, with the header given in Upper-and-Lower-Case characters and the short form derived from it in ALL UPPER-CASE characters. Where applicable, the syntax of the query is given with the format of its response.
1.1.3. When can they be used?
The commands and queries listed here can be used for SDGxxxx Series digital instruments.
1
SDG1000 Programming Manual
1.1.4. Command Notation
The following notation is used in the commands: < > Angular brackets enclose words that are used placeholders, of which there are two types: the header path and the data parameter of a command. := A colon followed by an equals sign separates a placeholder from the description of the type and range of values that may be used in a command instead of the placeholder. { } Braces enclose a list of choices, one of which one must be made. [ ] Square brackets enclose optional items. … An ellipsis indicates that the items both to its left and right may be repeated a number of times.
2
SDG1000 Programming Manual
1.2. Table of Commands & Queries
Short Long Form Subsystem What Command/Query dose *IDN *IDN SYSTEM Get identification from
device.
*OPC *OPC SYSTEM Get or set the OPC bit (0)
in the Event Status Register (ESR).
CHDR COMM_HEADER Set the format of return data
(Long, short, off)
HTBSWVTH
ARWV ARBWAVE Data
HTBUZZTH
SHTCFGTH
ROSC ROSCILLATOR SIGNAL Set or get clock source. MOD MODULATION SIGNAL Set or get modulated wave
OUTP OUTPUT SIGNAL Set or get output state. CHCP CHANNEL_COPY SIGNAL Copy parameters from channel
INVT INVERT SIGNAL Set or get output signal phase
HTSCSVTH
SWE SWEEP SIGNAL Set or get sweep wave.
HTSYNCTH
BTWV BURSTWAVE SIGNAL Set or get burst wave
MDWV MODULATEWAVE SIGNAL Set or get modulate wave
STL STORE_LIST SIGNAL Get the list of store wave. WVDT WAVE_DATA SIGNAL Get the wave data of store . VKEY VIRTUALKEY SYSTEM Set the virtual key.
BASIC_WAVE SIGNAL Set or get basic wave
parameters. Turns on or off channel signal. Change arbitrary wave type.
SYSTEM BUZZER SYSTEM Set or get buzzer State. SYSTEM_CONFIG SYSTEM Set or get power on
initializing parameter way
parameters.
one to channel two, or from channel two to channel one.
state.
SCREEN_SAVE SYSTEM Set or get screen save State.
SYNC SIGNAL Set or get in-phase signal.
parameters.
parameters.
3
SDG1000 Programming Manual
1.3. IEEE 488.2 Common Command Introduction
IEEE standard defines the common commands used for querying the basic information of the instrument or executing basic operations. These commands usually start with "*" and the length of the keywords of the command is usually 3 characters.
1.3.1 CHDR
DESCRIPTION This Command is used to change query command return format.
SHORT parameter is return short format. LONG parameter is
return long format. Off is that command header and parameter unit will not return.
COMMAND SYNTAX Comm_HeaDeR <parameter> <parameter>:= {SHORT,LONG,OFF}
QUERY SYNTAX Comm_HeaDeR?
RESPONSE FORMAT SYNC <parameter>
EXAMPLE 1 Set query command format to long. CHDR LONG
EXAMPLE 2 Read query command format. CHDR? return: COMM_HEADER LONG
4
SDG1000 Programming Manual
1.3.2 OPC
DESCRIPTION The *OPC (OPeration Complete) command sets to true the OPC
bit (bit 0) in the standard Event Status Register (ESR). The *OPC? query always responds with the ASCII character 1 because the device only responds to the query when the previous command has been entirely executed.
QUERY SYNTAX *OPC?
RESPONSE FORMAT *OPC 1
5
SDG1000 Programming Manual
1.3.3 IDN
DESCRIPTION The *IDN? Query causes the instrument to identify itself.
The response comprises manufacturer, scope model, serial number, software version and firmware version.
QUERY SYNTAX *IDN?
RESPONSE FORMAT *IDN ,<device id>,<model>,<serial number>,<software
version>,<firmware version> <device id>:=“SDG”is used to identify instrument. <model>:= A model identifier less than 14 characters. <serial number>:= A nine- or 10-digit decimal code . <software version>:= A serial numbers about software
version. <firmware version>:= two digits giving the major release level followed by a period, then one digit giving the minor release level followed by a period and a single-digit update level (xx.y.z).
EXAMPLE 1 Reads version information.
*IDN? return: *IDN SDG SDG1022,00-00-00-13-22,1.01.01.10R1,20.234.3. (return may differ form each version)
6
SDG1000 Programming Manual
1.4. Output Command
DESCRIPTION Enable or disable the output of the [Output] connector at
the front panel corresponding to the channel. The query returns ON or OFF.
COMMAND SYNTAX <channel>: OUTPut <parameter> <channel>:={C1,C2}
<parameter >:= {a parameter from the table below}
Parameters Value Description ON --- Turn on channel OFF --- Turn off channel LOAD <load> Value of load
where: <load>:= {50(default unit is ohm), HZ}
QUERY SYNTAX <channel>: OUTPut?
RESPONSE FORMAT <channel>:OUTPut <load>
EXAMPLE 1 Turns on channel one.
C1:OUTP ON
EXAMPLE 2 Reads channel one output state.
C1:OUTP? return: C1:OUTP ON,LOAD,HZ
EXAMPLE 4 Set the load to 50Ω C1:OUTP LOAD,50
7
SDG1000 Programming Manual
1.5. Basic Wave Command
DESCRIPTION Set or get basic wave parameters. COMMAND SYNTAX <channel>:BaSicWaVe <parameter> <channel>:={C1, C2}
<parameter>:= {a parameter from the table below}
Parameters Value Description WVTP <type> Type of wave
Value of frequency. I
FRQ <frequency>
AMP <amplifier>
OFST <offset>
SYM <symmetry>
DUTY <duty>
PHSE <phase>
VAR <variance>
MEAN <mean>
f wave type is Noise, you cant set this p arameter. Value of amplifier. I f wave type is Noise, you cant set this p arameter. Value of offset. If w ave type is Noise, yo u cant set this para meter. Value of symmetry. Only wave type is Ramp, you can set this parameter. Value of duty cycle. Only Pulse and Duty can set this parameter. Value of phase. If wa ve type is Noise, you cant set this param eter. Value of Noise wave Variance. Only wave type is Noise, you can set this parameter. Value of Noise wave mean. Only wave type is Noise, you can set this parameter.
8
SDG1000 Programming Manual
Value of delay. Only
DLY <delay>
Note: if the command dont set basic wave type, the parameter will set parameters to current device wave type default.
where: <type>:={SINE, SQUARE, RAMP, PULSE, NOISE, ARB ,DC}
<frequency>:= { Default unit is "HZ". Minimum value is 1xe-6 HZ, maximal value depends on the version.} <amplifier>:= {Default unit is "V". Channel one minimum value 0.004V, Maximal is 6V. Channel two minimum value
0.004V, Maximal is 20V. } <offset>:= { Default unit is "V". maximal value depends on the maximal value depends on the version.} <duty>:= {If wave type is square, range is from 20% to 80%. if wave type is pulse, range is from 0.1% to 99.9%} <symmetry> :={ 0% to 100%} <phase>:= {0° to 360°} <variance>:= Maximal is 2.222V, minimum value is 0.4mV.The default unit is "V". <mean>:= The range depends on Variance . The default unit is "V". <delay>:= Maximal is Pulse Period, minimum value is 0.Unit is S.
QUERY SYNTAX <channel>:BaSicWaVe? <channel>:={C1, C2}
RESPONSE <channel>:BSWV <type>,<frequency>,<amplifier>,<offset>,
<duty>, <symmetry>, <phase>
EXAMPLE 1 change channel one current wave type to ramp. C1:BSWV WVTP,RAMP
EXAMPLE 2 Changes current signal frequency of channel one to 2000 Hz.
C1: BSWV FRQ, 2000HZ
EXAMPLE 3 set current signal amplifier of channel one. C1: BSWV AMP, 3V
wave type is Pulse, you can set this parameter.
9
Loading...