Sierra Monitor offers a variety of accessories for gas sensor modules to aid the user
in calibration, placement and use of gas
sensor modules to ensure accurate and
reliable monitoring of hazardous gases.
CALIBRATORS
1200-26 Calibration Gas Delivery System
The Model 1200-26 Calibration Gas Delivery System provides
calibration gas for Combustible Gas, Carbon Monoxide, or Oxygen Deficiency gas detection monitors. This system consists of
disposable pressure vessels (2 cylinders supplied with each system) containing calibration gas and a non-disposable pressure
and flow regulation system. Gas flow is controlled in two steps
with a regulator and flow meter to conserve gas and to accurately regulate flow.
The 1200-26 and the Methane calibration gas cylinders are approved for calibration of FM Approved Sierra Monitor Combustible Gas Sensors.
1250-XX Calibrator Kit
The 1250-XX Calibrator Kit is used to deliver calibration gas for
combustible gases and a wide variety of toxic gas detection
modules including Carbon Monoxide, Hydrogen, Combustible
Gas, Hydrogen Sulfide, Chlorine, Sulfur Dioxide, Nitric Oxide,
Nitrogen Dioxide and Zero
Grade Air. Other gases are
available, contact Sierra
Monitor for the latest information. There are three
versions of the calibration
kit available depending
upon the specific calibration gas required. Each kit
contains a regulator, calibration adapter and carrying case. The individual
calibration gas cylinders
(Series 1260) are sold
separately.
9210-00 Permeation Type Calibrator
The 9210-00 Permeation Type Calibrator with the individual permeation tube for the specific gas required offers a unique means
of generating a desired gas. This device has the advantages of
a wide selection of gas types, long life, and is an economical
solution for the regular calibration of a large number of toxic
sensors. Most popular applications are ammonia and hydrogen
sulfide.
Gas Sensor Accessories
Model 1200-26
Model 1250-01 Calibration Kit
Type A (with cylinder)
Sierra Monitor Corporation 1991 Tarob Ct. Milpitas, CA 95035 (408) 262-6611 800-727-4377 FAX: (408) 262-9042
Visit our Web site at: www.sierramonitor.com E-Mail: sales@sierramonitor.com
Specifications for 1200-26
Specifications for 1200-26
Dimensions: 4.0 x 7.0 x 3.0 in. (10.2 x 17.8 x 7.6 cm)
Dimensions: 4.0 x 7.0 x 3.0 in. (10.2 x 17.8 x 7.6 cm)
Weight: 2.75 lb (1.24 kg.) (including cylinder)
Weight: 2.75 lb (1.24 kg.) (including cylinder)
Flow Rate: 50-500 cc/min
Flow Rate: 50-500 cc/min
Cylinder Pressure: Max180 psi
Cylinder Pressure: Max 180 psi
Cylinder Volume: 0.27 cu. ft. (7.7 liters) at STP
Cylinder Volume: 0.27 cu. ft. (7.7 liters) at STP
pecifications for 1260 Series Gas Cylinders:
pecifications for 1260 Series Gas Cylinders:
ype A Gas Cylinders (Combustible Gas - LEL, CO, H2, Air)
ype A Gas Cylinders (Combustible Gas - LEL, CO, H2, Air)
Dimensions (cylinder):13.75 x 3.25 in. (34.9 x 8.2 cm)
Dimensions (cylinder):13.75 x 3.25 in. (34.9 x 8.2 cm)
Weight (Cylinder): 2.3 lb. (1.05 Kg)
Weight (Cylinder): 2.3 lb. (1.05 Kg)
Cylinder pressure: Max 1000 psig
Cylinder pressure: Max 1000 psig
Cylinder volume: 3.6 cu. ft. (105 liters) at STP
Cylinder volume: 3.6 cu. ft. (105 liters) at STP
ype A Gas Cylinders (H
ype A Gas Cylinders (H
Dimensions (cylinder):13.5 x 3.5 in. (34.3 x 8.9 cm)
Dimensions (cylinder):13.5 x 3.5 in. (34.3 x 8.9 cm)
Weight (Cylinder): 1.8 lb. (0.8 Kg)
Weight (Cylinder): 1.8 lb. (0.8 Kg)
Cylinder pressure: Max 500 psig
Cylinder pressure: Max 500 psig
Cylinder volume: 2.0 cu. ft. (57 liters) at STP
Cylinder volume: 2.0 cu. ft. (57 liters) at STP
ype B Gas Cylinders (SO2, NO2, NO)
ype B Gas Cylinders (SO2, NO2, NO)
Dimensions (cylinder):16.25 x 4.0 in. (41.3 x 10.2 cm)
Dimensions (cylinder):16.25 x 4.0 in. (41.3 x 10.2 cm)
Weight (Cylinder): 1.75 lb. (0.8 Kg)
Weight (Cylinder): 1.75 lb. (0.8 Kg)
Cylinder pressure: Max 480 psig
Cylinder pressure: Max 480 psig
Cylinder volume: 2.6 cu. ft. (74 liters) at STP
Cylinder volume: 2.6 cu. ft. (74 liters) at STP
ype C Gas Cylinders (CI2)
ype C Gas Cylinders (CI2)
Dimensions (cylinder):12.25 x 3.25 in. (31.1 x 8.2 cm)
Dimensions (cylinder):12.25 x 3.25 in. (31.1 x 8.2 cm)
Weight (Cylinder): 2.2 lb. (1.0 Kg)
Weight (Cylinder): 2.2 lb. (1.0 Kg)
Cylinder pressure: Max 1800 psig
Cylinder pressure: Max 1800 psig
Cylinder volume: 3.7 cu. ft. (104 liters) at STP
Cylinder volume: 3.7 cu. ft. (104 liters) at STP
S for 4101/5100-05)
S for 4101/5100-05)
2
2
Sierra Monitor Corporation 1991 Tarob Ct. Milpitas, CA 95035 (408) 262-6611 800-727-4377 FAX: (408) 262-9042
Visit our Web site at: www.sierramonitor.com E-Mail: sales@sierramonitor.com
© 2006 by Sierra Monitor Corporation Printed in U.S.A. Rev. A 5/23/06
ACCESSORIES
SAMPLE DRAW PRODUCTS
Sample draw products are used in applications in which the sensor
cannot be installed directly at the gas sensing location due to poor
accessibility or the harshness of the environment. Sample is continuously drawn from the sensing location to the sensor at a more
suitable location.
The primary component of the sample draw product is a venturi
manifold that uses a continuous flow of driver air to pull a slight vacuum
through the sample supply line drawing the sample into the manifold
cavity connected to the sensor.
5399-01 Sample Draw Fitting
The sample manifold assembly is the 5399-01 Sample Draw Fitting.
Sample stream draw and flow control is provided by the user.
5398-01 Sample Draw Assembly
The 5398-01 Sample Draw Assembly is a complete sample draw
assembly including the sample draw fitting, flow metering assembly,
plus the driver air, sample and exhaust fittings. This allows accurate
adjustment of sample flow using the signal flow meter located on the
flow metering assembly.
5398-02 Sample Draw/Dilution Assembly
For applications where the expected gas concentration is either higher
than maximum range of the sensor or sufficiently high to significantly
reduce sensor life with extended exposure, the 5398-02 Sample Draw/
Dilution Assembly is recommended. This assembly adds a second
flow meter for control of dilution air. Adjustment of sample and dilution air flow meters achieves the dilution ratio required. Concentrations displayed on the sensor controller must then be multiplied by
the dilution factor to arrive at actual consecrations.
SENSOR MOUNTING PRODUCTS
5360-00 Calibration Gas Delivery Fitting
The Calibration Gas Delivery Fitting provides the ability to deliver the
gas to the sensor module in a remote location. A tube fitting enables
the operator to direct calibrations gas flow to the sensor at any time
desired.
5311-00 Rainshield
The Rainshield is mounted over the sensor head to protect the sensor from direct exposure to rain, hosedown and other splashing liquids.
5394-00 Duct Mount Fitting
The Duct Mount Fitting facilitates installation of the gas sensor module onto an air duct. The fitting also includes the 5360-00 calibration
gas delivery fitting so that calibration gas can be delivered to the
sensor with out removing the module from the duct.
Gas Sensor Accessories
CALIBRATION ADAPTERS
The Sierra Monitor Gas sensor modules are designed for easy calibration. The standard calibration adapter screws over the head of
sensor. Then calibration gas is fed through a tube connected onto
the adapter.
Most Sierra Monitor gas sensor modules are equipped with a magnetic switch to signal the sensor module that calibration is being performed. The magnetic calibration adapter is used to control this
switch. When the adapter is attached to the sensor the switch closes
to indicate the tart of calibration. The sensor module will then hold
the present output until the magnetic calibration adapter is removed
signaling completion of calibration.
There are two calibration adapters available, the 5358-00 Magnetic
Calibration Adapter and the 5358-01 Standard (non-magnetic) Calibration Adapter. The magnetic adapters are needed when the user
needs to hold the current value during calibration to avoid nuisance
alarms and the standard (non-magnetic) adapter if necessary during global calibration.
5311-00
5394-00
5360-00
5398-01
5399-01
5398-02