Siemens TEL50.GSM General Instructions Manual

s
Rev 04 - 10-09-2008
Building Technologies G5434 - TEL50.GSM
General Instructions
Building Technologies i TEL50.GSM
en English
1.
INTRODUCTION ...........................................................1
1.1 Copyright ................................................................1
1.2 Trademarks ............................................................1
1.3 Declaration of conformity........................................2
1.4 Warranty.................................................................3
1.5 Contents of sales pack ...........................................3
2. INSTRUCTIONS............................................................4
2.1 Safety instructions ..................................................4
2.2 Operating instructions ............................................6
3. GENERAL INFORMATION ..............................................7
4. INSTALLATION.............................................................8
4.1 Wall-mounting ........................................................8
4.2 Electrical connections.............................................8
4.3 Connection of stilo antenna..................................11
4.4 Connection of external antenna (optional) ........... 11
4.5 Insertion of SIM card ............................................12
4.6 Checking of indicator lamps .................................13
5. TECHNICAL DATA ......................................................14
6. BASIC CONFIGURATION .............................................15
6.1 Commands via DTMF tones.................................15
6.2 Commands via SMS.............................................16
6.3 Temperature sensor querying ..............................17
7. EXTENDED CONFIGURATION......................................18
7.1 Creation of a qualified user list.............................18
7.2 Modification of Input-Output identification string .. 20
7.3 Alarm notification enabling ...................................22
7.3.1 IN1 closed alarm....................................... 22
7.3.2 Temperature alarm................................... 22
7.4 Digital I/O status...................................................24
8. ENVIRONMENTAL COMPATIBILITY AND DISPOSAL ........25
9. SIGNALLING ERROR ..................................................25
Building Technologies - 1 - TEL50.GSM
en English
1. Introduction
Thank you for choosing this product. Please read this manual carefully to optimize use of the TEL50.GSM.
1.1 Copyright
Siemens S.p.A. All rights reserved. The reproduction, modification or transcription of this document without prior written authorization is forbidden except as allowed under the copyright laws. Copyright© 2005
1.2 Trademarks
TEL50.GSM is a Siemens S.p.A. registered trademark.
Building Technologies - 2 - TEL50.GSM
1.3 Declaration of conformity
Siemens S.p.A.
Building Technologies
Viale Piero ed Alberto Pirelli, 10 - 20126 Milano (MI) Italy
declares on its sole responsibility that the following product:
TEL50.GSM
complies with the regulations in force with reference to the R&TTE 99/5/EC directive
and, above all, with the following standards:
Health and Safety (Art. 3.1 a) EN 60950:2000
EMC (Art. 3.1 b) EN 301489-7 v1.1.1 (09/2000)
RF spectrum efficiency (Art. 3.2) EN 301419-1 v4.1.1 (03/2000) incl. EN 301511 v7.0.1 (12/2000)
Building Technologies - 3 - TEL50.GSM
1.4 Warranty
This product is guaranteed against any material and manufacture defects. SIEMENS reserves the right, at its own discretion, to repair or replace faulty products. The warranty is deemed null and void if the fault is caused by improper use or by an operating procedure that is not included in this manual.
The warranty will not cover faults caused by:
• improper and careless use
• damage caused by atmospheric agents
• acts of vandalism
• material that is subject to wear and tear
1.5 Contents of sales pack
• User Manual (this manual)
• TEL50.GSM device
• 230VAC / 12VDC 1A power supply
• GSM stilo antenna
Building Technologies - 4 - TEL50.GSM
2. Instructions
In order to use the product safely and efficiently, please read the following instructions carefully before use. The product may only be employed for the use for which it has been conceived and manufactured. Any other use shall be considered the user’s sole responsibility.
2.1 Safety instructions
Installation, programming and commissioning should only be carried out by qualified operators; these operators must be physically and mentally capable of performing the task. Commissioning may only occur after the product has been correctly installed. For this reason, users must carefully perform all the operations described in the manual supplied.
SIEMENS will disclaim all responsibility for any failure, breakage, accident, etc. due to the lack of knowledge of or failure to observe given instructions. The same shall apply to any unauthorized changes.
SIEMENS reserves the right to change the product for constructive or commercial reasons without being obliged to update reference manuals promptly.
The TEL50.GSM uses the GSM standard for mobile telephony. As a result; it cannot be used in areas that are outside the system coverage area.
Since the GSM system is a radiofrequency (RF) technology, it may interfere with other telephones or create problems with electronic devices that are not adequately protected from RF energy.
Building Technologies - 5 - TEL50.GSM
Precautions:
Do not install and use the product in close proximity to electromedical equipment without checking that this is permitted.
During operating, the product may cause interference to transceiver equipment such as televisions, radios, PCs. Move the product so that there is no more interference.
Hearing aids or pacemakers or other personal medical devices may be subjected to interference when the device is in operation. Consult your doctor for further information.
Dispose of the product and accessories at the end of their service life in accordance with regulations.
The device must not be tampered with. Only replacement of the SIM card is permitted. Any other modification will render the warranty void. Contact the authorised service centres if necessary.
The device must not be used in the proximity of filling stations or where there is a risk of explosion. It must not be used in places where chemical agents are in use and special attention must be paid to the safety regulations for environments that are saturated (or potentially saturated) with volatile gases or exhalations.
The product is fully compliant with the safety standards with regard to exposure to radiofrequency energy.
Building Technologies - 6 - TEL50.GSM
2.2 Operating instructions
1. The SIM Card must always be inserted and removed when there is no power supply. If not, the SIM Card read interface inside the GSM module could be damaged.
2. Always disable the PIN code of the SIM card. If not, the TEL50.GSM cannot operate. Delete from SIM card all
lists of SMS (inbox, outbox, sent items) and disable all additional services (answering service, call forwarding, etc). Do this using a normal mobile phone. SIM card (non included) could be for voice traffic only. However we
recommend using SIM cards that are also enabled for data traffic.
3. Check that the area of use has adequate GSM coverage for the selected operator. Check that the GSM signal is present using the special LED on the device (see par. 4.6) or a normal mobile phone. Place the device in an area where there is good signal reception (eg. near a window or door). If there is no signal or the signal is weak, you can install an external antenna in a more favourable place using the optional lead.
4. Do not power the TEL50.GSM without first connecting the stilo antenna supplied: otherwise, the power section
of the radio transmitter in the GSM unit could be seriously damaged.
5. There is no guarantee of SMS message forwarding times from and to the device (commands, querying or alarm reception). SMS management is the exclusive responsibility of the mobile telephone network companies.
6. It is advisable to set SECURITY=1 (incoming call filter – see par. 7.1). This will limit device’s answer only to user list numbers (e.g. no answer to promotional SMS).
Building Technologies - 7 - TEL50.GSM
3. General information
The TEL50.GSM phone remote control has been designed for remote operation of electrical or electro-hydraulic equipment such as room thermostats, boilers, burners, heaters, zone valves, circulation pumps, irrigation systems, etc. It is particularly suitable for holiday home installations where there is no fixed telephone network. The remote control can only be used through the GSM mobile network. Commands can be sent via the fixed telephone network (DTMF tones) or GSM mobile network (DTMF tones and SMS messages with preset syntax). The TEL50.GSM also allows connection of an LG-Ni1000 temperature sensor (optional) and forwarding via SMS, subject to special querying, of the temperature value measured at that time. The device can handle both a temperature threshold exceeded alarm (adjustable) and a general alarm to be connected to the respective input on the terminal box. In both cases, activation of the alarm generates a specific SMS that is sent to a predefined user list. The 2 control outputs can be enabled completely separately. You can enable and/or disable the outputs locally using the button on the device according to the following binary sequence.
Cycle OUT1 OUT2
1 OFF OFF 2 ON OFF 3 OFF ON
4 ON ON The device is suitable for use with the Chronogyr room temperature controllers REV16 – REV23 – REV33 – REV100 – REV200 and new REV13.. - REV17.. ­REV24.. - REV34..
SMS
DTMF
DTMF
Loading...
+ 19 hidden pages