Siemens SPC5000, SPC6000 Installation & Configuration Manual

Building Technologies
Fire Safety & Security Products
Intrusion Control Panel
SPC5000/6000
Installation&Configuration Manual
Technical Data
16
Siemens Building Technologies
Fire Safety & Security Products 09.2008
3 Technical Data
3.1 SPC5000/6000 Controller
Mains voltage 230 V AC, +10 to -15 %, 50 Hz
Fuse 250 mA T
Power consumption
SPC5220/5230: 160 mA at 230 V AC SPC6320/6330: 200 mA at 230 V AC
Auxiliary power (nominal)
1)
Max. 750 mA at 12 V DC
Battery Optional
Battery type Sealed cell valve-regulated
Battery capacity
SPC5220/6320: Max. 7 AH / 12 V SPC5230/6330: Max. 17 AH / 12 V
Battery charger Max. 24h for 80 % of battery capacity
Current consumption 1)
SPC5220/5230: Max. 160 mA at 12 V DC SPC5320/5330: Max. 200 mA at 12 V DC
Number of on-board zones 8
EOL resistor Dual 4K7 (default), other resistor combinations configurable
Number of on-board open collector outputs.
1 internal bell (max. 400 mA resistive), 1 external bell (max. 400 mA resistive), 3 general outputs (each max. 400 mA resistive, supplied via auxiliary output)
Number of on-board relays 1 strobe, 30 V / 1 A (resistive switching current)
Field bus 2) X-BUS on RS-485 (307 kb/s)
Interfaces
SPC5220/5230 and SPC6320/6330: 2 X-BUS (2 spurs or 1 loop), 2 RS232 (RJ45 ports, for X-10 or external communication) 1 USB (PC for browser programming / terminal program), 1 SPC Fast Programmer, Additional on the SPC6320/6330: 1 Ethernet (RJ45)
Tamper contact
On-board front cabinet spring tamper + 2 auxiliary tamper inputs
Operating temperature 5 - 40 °C
Relative humidity Max. 90 % (no condensation)
Housing protection IP30
Colour RAL 9003
Housing protection class Class II Indoor General
Mounting Surface, wall-mounted
Housing material Steel > 1.2 mm
Housing
SPC5220/6320: Metal enclosure SPC5230/6330: Hinged metal enclosure
Housing can contain up to
SPC5220/6320: 1 additional Expander (size 150 mm x 82 mm) SPC5230/6330: 4 additional Expanders (size 150 mm x 82 mm)
Standards
SPC5220/6320: Designed to meet EN50131-1:2006 (Grade 2) TS50131-3:2003 (Grade 2) EN50131-6:2008 (Grade 2) SPC5230/6330: Designed to meet EN50131-1:2006 (Grade 3), TS50131-3:2003