Safety Guidelines
Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed.
Qualified Personnel
This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards.
Unit Repair and Excluded Liability:
The user is responsible for all changes and repairs made to the device by the user or the user’s agent.
All new components are to be provided by Siemens.
Restrict repair to faulty components only.
Do not reuse faulty components.
Warning: Cardboard shipping package provides limited humidity and moisture protection. This product can only function properly and safely if
it is correctly transported, stored, installed, set up, operated, and maintained.
This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications.
Note: Always use product in accordance with specifications.
Copyright Siemens AG 2015. All Rights Reserved Disclaimer of Liability
This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens. Siemens will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions.
While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement.
Technical data subject to change.
European Authorized Representative
Siemens AG Industry Sector 76181 Karlsruhe Deutschland
For a selection of Siemens level measurement manuals, go to: www. siemens.com/processautomation. Select Products & Systems, then under Process Instrumentation, select Manual archives can be found on the Support page by product family.
For a selection of Siemens weighing manuals, go to:
www. siemens.com/processautomation. Under Products & Systems, select Manual archives can be found on the Support page by product family.
Weighing and Batching Systems.
Level Measurement.
© Siemens AG 2015
SITRANS RD500 MODULE HSPA+ CELLULAR MODEM OPTION CARD
CONFIGURED USING SITRANS RD500 SOFTWARE
INSTALLS INSIDE A SITRANS RD500
INSTALLATION AND CONNECTION HARDWARE ARE
INCLUDED WITH CARD
GENERAL DESCRIPTION
The option card allows the user to add HSPA+ cellular modem capability to their SITRANS RD500. HSPA+ is the most prevalent cellular technology in today’s markets. The cellular standard adopted in this option card is HSPA+ with fallback capability to 3G and 2G. It can get speeds up to 21 Mbps downlink and 5.76 Mbps uplink. It’s built upon the GSM standard and widely availavle throughout the world. HSPA+ can be used for services such as Wireless Application Protocol (WAP) access, Short Message Service (SMS), and for Internet connectivity. The modem option card is penta-band, allowing it to work in frequencies across the Americas, Europe and Asia. US and Canada work in the 850/1900 MHz bands, while Europe, Middle East, Africa and most of Asia work in the 900/1700/2100 MHz HSPA+ frequencies.
The card requires the addition of a SIM (Subscriber Identity Module) card, which is inserted into the holder prior to installation of the SITRANS RD500 card. The SIM card securely stores the service-subscriber key (IMSI) used to identify a subscriber, and is used to connect to the network to obtain an IP address from the provider.
The communication card is easily installed by removing the blank expansion port cover of your SITRANS RD50 0, and plugging the card into the expansion port. Configuration is simple using RD500.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the controller.
Read complete instructions prior to installation
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2
THIS EQUIPMENT IS ONLY SUITABLE FOR USE IN NON-HAZARDOUS OR CLASS I, DIVISION 2, GROUPS A, B, C, D, LOCATIONS
CAUTION: Risk of Danger.
and operation of the unit.
CONTENTS OF PACKAGE
- SITRANS RD500 option card
- This hardware bulletin
SPECIFICATIONS
1. POWER REQUIREMENTS:
HSPA+ Mode: During continuous active webserver traffic
Instantaneous maximum: 24 V @ 300 mA Average: 24 V @ 20 0 mA
GPRS Mode:
Instantaneous maximum: 24 V @ 650 mA (1.1 msec every 4.6 msec)
Average: 24 V @ 275 mA Power is supplied to the option card from the main board of the SITRANS RD500.
2. LINK STATUS LEDs:
Link Status - Link Status LED shows cellular link condition.
3. ANTENNA CONNECTOR:
SMA Female connector requires:
50 Ohm antenna with SMA male connector
Penta-band HSPA+ antenna (850/900/1700/1900/2100 MHz) for global
support. Dual-band (850/1900 MHz) antenna for US and Canada only Dual band (900/2100 MHz) for Europe only
Voltage Standing Wave Ratio (VSWR) should not exceed 2.0:1 The antenna cable should be 50 impedance, RG178/U or RG174/U
type and be able to connect to the RSMA (Male) jack bulkhead. The antenna could be horizontal, vertical or right angled. Longer antenna cable would equate to signal loss.
This device is intended for connection to an antenna mounted within
the building or a UL certified enclosure suitably rated for application.
3. CERTIFICATIONS AND COMPLIANCES:
Refer to SITRANS RD500 Master manual for agency certifications.
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.
Reference SITRANS RD500 for EMC specifications
The HSPA+ option card has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the FCC rules.
4. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 50°C Storage Temperature Range: -20 to 80°C Operating and Storage Humidity: 80% maximum relative humidity (non-
condensing) from 0 to 50°C.
Altitude: Up to 2000 meters.
5. CONSTRUCTION: For indoor use only. Installation Category II, Pollution Degree 2.
6. INSTALLATION REQUIREMENTS: See “Installing the SITRANS RD500 Option card” for more details.
7. WEIGHT: 3.0 oz (85.05 g)