Siemens SITRANS L Series,SITRANS Probe LR with mA/HART Compact Operating Instructions

SITRANS L
Radar transmitters SITRANS Probe LR with mA/HART
Compact Operating Instructions
05/2019
A5E46248119
Introduction
1
Safety notes
2
Description
3
Installing/mounting
4
Connecting
5
Commissioning
6
Service and maintenance
7
Technical data
8
Certificates and support
A
-AC
Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY
Document order number: A5E46248119
Copyright © Siemens AG 2019. All rights reserved
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Legal information Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
06/2019 Subject to change
Table of contents
1 Introduction ................................................................................................................................................ 6
1.1 Checking the consignment ....................................................................................................... 6
1.2 Industrial use ............................................................................................................................. 6
1.3 Security information .................................................................................................................. 6
1.4 Purpose of this documentation ................................................................................................. 7
2 Safety notes ............................................................................................................................................... 8
2.1 Preconditions for use ................................................................................................................ 8
2.1.1 Safety marking symbols ............................................................................................................ 8
2.2 Laws and directives .................................................................................................................. 8
2.2.1 Radio Equipment Directive (RED) compliance (Europe) .......................................................... 8
2.2.2 Industry Canada conformity ...................................................................................................... 9
2.2.3 Conformity with European directives ........................................................................................ 9
2.2.4 FCC Conformity ...................................................................................................................... 10
2.2.5 CE electromagnetic compatibility (EMC) conformity .............................................................. 10
2.3 Use in hazardous areas .......................................................................................................... 11
2.3.1 Qualified personnel for hazardous area applications ............................................................. 11
2.3.2 Loss of safety of device with type of protection "Intrinsic safety Ex i" .................................... 11
3 Description ............................................................................................................................................... 12
3.1 SITRANS Probe LR ................................................................................................................ 12
3.2 Ambient/operating temperature .............................................................................................. 13
4 Installing/mounting ................................................................................................................................... 14
4.1 Basic safety notes ................................................................................................................... 14
4.1.1 Incorrect disassembly ............................................................................................................. 14
4.2 Mounting location .................................................................................................................... 15
4.3 Nozzle location ........................................................................................................................ 16
4.4 Nozzle design ......................................................................................................................... 17
4.5 Mounting instructions .............................................................................................................. 18
5 Connecting .............................................................................................................................................. 19
5.1 Power ...................................................................................................................................... 19
5.2 Connecting SITRANS Probe LR ............................................................................................. 19
5.3 Nameplate for hazardous area installations ........................................................................... 20
5.4 FM and CSA connection drawings ......................................................................................... 21
5.5 Instructions specific to hazardous area installations (reference European ATEX
SITRANS Probe LR with mA/HART Compact Operating Instructions, 05/2019, A5E46248119-AC
Directive 2014/34/EU Annex II, 1/0/6) .................................................................................... 21
3
Table of contents
6 Commissioning ........................................................................................................................................ 23
6.1 Basic safety notes .................................................................................................................. 23
6.2 Local commissioning .............................................................................................................. 23
6.2.1 Activating SITRANS Probe LR ............................................................................................... 23
6.2.2 Operating SITRANS Probe LR .............................................................................................. 23
6.2.3 Low temperature effects on RUN/PROGRAM modes ........................................................... 24
6.2.4 RUN mode ............................................................................................................................. 24
6.2.5 PROGRAM mode................................................................................................................... 25
6.2.6 Handheld programmer ........................................................................................................... 25
6.2.6.1 Handheld programmer ........................................................................................................... 26
6.2.6.2 Handheld programmer: function keys in PROGRAM mode .................................................. 27
6.2.6.3 Handheld programmer: function keys in RUN mode ............................................................. 28
6.2.6.4 Accessing a parameter .......................................................................................................... 28
6.2.7 Security .................................................................................................................................. 30
6.2.8 Changing a parameter value .................................................................................................. 30
6.2.9 Master reset ........................................................................................................................... 30
6.2.10 Using units or percent (%) ..................................................................................................... 31
6.2.11 Quick start wizard................................................................................................................... 31
6.2.11.1 Quick setup for local operation (outline) ................................................................................ 31
6.2.11.2 P010: Language ..................................................................................................................... 32
6.2.11.3 P001: Operation ..................................................................................................................... 32
6.2.11.4 P003: Measurement response ............................................................................................... 33
6.2.11.5 P005: Units ............................................................................................................................. 34
6.2.11.6 P006: Empty ........................................................................................................................... 34
6.2.11.7 P007: Span ............................................................................................................................ 35
6.2.11.8 P838 Auto false echo suppression ........................................................................................ 35
6.2.11.9 Additional settings .................................................................................................................. 36
6.3 Remote commissioning .......................................................................................................... 36
6.3.1 SITRANS Probe LR communication: HART .......................................................................... 36
7 Service and maintenance ........................................................................................................................ 37
7.1 Cleaning ................................................................................................................................. 37
7.2 Maintenance and repair work ................................................................................................. 37
7.3 Return procedure ................................................................................................................... 37
7.4 Disposal ................................................................................................................................. 38
8 Technical data ......................................................................................................................................... 39
8.1 Power ..................................................................................................................................... 39
8.2 Performance ........................................................................................................................... 40
8.3 Construction ........................................................................................................................... 40
8.4 Operating conditions .............................................................................................................. 41
8.5 Process .................................................................................................................................. 41
8.6 Approvals ............................................................................................................................... 42
A Certificates and support ........................................................................................................................... 43
A.1 Technical support ................................................................................................................... 43
SITRANS Probe LR with mA/HART
4 Compact Operating Instructions, 05/2019, A5E46248119-AC
Table of contents
A.2 Certificates .............................................................................................................................. 43
Index ........................................................................................................................................................ 44
SITRANS Probe LR with mA/HART Compact Operating Instructions, 05/2019, A5E46248119-AC
5
1
WARNING
Using a damaged or incomplete device
NOTICE
Use in a domestic environment

1.1 Checking the consignment

1. Check the packaging and the delivered items for visible damages.
2. Report any claims for damages immediately to the shipping company.
3. Retain damaged parts for clarification.
4. Check the scope of delivery by comparing your order to the shipping documents for
correctness and completeness.
Risk of explosion in hazardous areas.
Do not use damaged or incomplete devices.

1.2 Industrial use

This Class B Group 1 equipment is intended for use in industrial areas.
In a domestic environment this device may cause radio interference.

1.3 Security information

Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines, and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept.
Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place.
SITRANS Probe LR with mA/HART
6 Compact Operating Instructions, 05/2019, A5E46248119-AC
Introduction

1.4 Purpose of this documentation

Additionally, Siemens’ guidance on appropriate security measures should be taken into account. You can find more information about industrial security by visiting: https://www.siemens.com/industrialsecurity.
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends you apply product updates as soon as available and always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under https://www.siemens.com/industrialsecurity.
1.4 Purpose of this documentation
These instructions contain all information required to commission and use the device. Read the instructions carefully prior to installation and commissioning. In order to use the device correctly, first review its principle of operation.
The instructions are aimed at persons mechanically installing the device, connecting it electronically, configuring the parameters and commissioning it, as well as service and maintenance engineers.
SITRANS Probe LR with mA/HART Compact Operating Instructions, 05/2019, A5E46248119-AC
7
2
In manual
On product
Description
Yellow background

2.1 Preconditions for use

This device left the factory in good working condition. In order to maintain this status and to ensure safe operation of the device, observe these instructions and all the specifications relevant to safety.
Observe the information and symbols on the device. Do not remove any information or symbols from the device. Always keep the information and symbols in a completely legible state.

2.1.1 Safety marking symbols

earth (ground) terminal (shield)
WARNING: refer to accompanying documents (manual) for de­tails.

2.2 Laws and directives

2.2.1 Radio Equipment Directive (RED) compliance (Europe)

Hereby, Siemens declares that the SITRANS Probe LR is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The Probe LR complies with EN 302 372 for use in closed storage vessels, when installed according to the installation requirements of EN 302 372, and may be used in all EU countries. For the receiver test that covers the influence of an interferer signal to the device, the performance criterion has at least the following level of performance according to ETSI TS 103 361 [6]:
Performance criterion: measurement value variation Δd over time during a distance
measurement
SITRANS Probe LR with mA/HART
8 Compact Operating Instructions, 05/2019, A5E46248119-AC
Level of performance: Δd ±50 mm
Safety notes
NOTICE
Use on a "no-interference, no-protection" basis
Electromagnetic compatibil­ity EMC 2014/30/EU
Directive of the European Parliament and of the Council on the harmonisation of the laws of the Member States relating to elec­tromagnetic compatibility
Low voltage directive LVD 2014/35/EU
Directive of the European Parliament and of the Council on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment de­signed for use within certain voltage limits
Atmosphère explosible ATEX 2014/34/EU
Directive of the European Parliament and the Council on the harmonisation of the laws of the Member States relating to equipment and protective systems intended for use in potential­ly explosive atmospheres
RED 2014/53/EU
Directive of the Euro harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repeal­ing Directive 1999/5/EC
2.2 Laws and directives

2.2.2 Industry Canada conformity

Canada Installations only: Industry Canada (IC) rules
This device shall be installed and operated in a completely enclosed container to prevent RF emission, which otherwise can interfere with aeronautical navigation. Installation shall be done by trained installers, in strict compliance with the manufacturer’s instructions.
The use of this device is on a "no-interference, no-protection" basis:
The user shall accept operations of high-powered radar in the same frequency band
which may interfere with or damage this device.
The user is responsible for removing, at the user’s expense, any device found to
interfere with primary licensing operations.

2.2.3 Conformity with European directives

The CE marking on the device symbolizes the conformity with the following European directives:
The applicable directives can be found in the EC conformity declaration of the specific device.
pean Parliament and of the Council on the
SITRANS Probe LR with mA/HART Compact Operating Instructions, 05/2019, A5E46248119-AC
9
Safety notes
WARNING
Authority to operate equipment
Note
EMC standard
Title
frequency equipment.
61326:2012)
Use – Electromagnetic Compatibility.
measurement techniques – Electrostatic discharge immunity test.
magnetic field immunity test 2006 + A1:2008 + A2:2010.
test.
measurement techniques – Surge immunity test.
induced by radio-frequency fields.
munity test.
2.2 Laws and directives

2.2.4 FCC Conformity

US Installations only: Federal Communications Commission (FCC) rules
Changes or modifications not expressly approved by Siemens could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference to radio communications, in which case the user will be required to correct the interference at his own expense.

2.2.5 CE electromagnetic compatibility (EMC) conformity

This equipment has been tested and found to comply with the following EMC standards:
CISPR 11:2009 + A1:2010/EN 55011:2009 + A1:2010, CLASS A
EN 61326:2013 (IEC
EN61000-4-2:2009 Electromagnetic Compatibility (EMC) Part 4-2: Testing and
EN61000-4-3:2006 + A1:2008 + A2:2010
EN61000-4-4:2004 + A1:2010 Electromagnetic Compatibility (EMC) Part 4-4: Testing and
EN61000-4-5:2006 Electromagnetic Compatibility (EMC) Part 4-5: Testing and
EN61000-4-6:2010 Electromagnetic Compatibility (EMC) Part 4-6: Testing and
EN61000-4-8:2010 Electromagnetic Compatibility (EMC) Part 4-8: Testing and
Limits and methods of measurements of radio disturbance char­acteristics of industrial, scientific, and medical (ISM) radio-
Electrical Equipment for Measurement, Control and Laboratory
Electromagnetic Compatibility (EMC) Part 4-3: Testing and measurement techniques – Radiated, radiofrequency, electro-
measurement techniques – Electrical fast transient/burst immunity
measurement techniques – Immunity to conducted disturbances,
measurement techniques – Power frequency magnetic field im-
SITRANS Probe LR with mA/HART
10 Compact Operating Instructions, 05/2019, A5E46248119-AC
Safety notes
WARNING
Loss of safety of device with type of protection "Intrinsic safety Ex i"

2.3 Use in hazardous areas

2.3 Use in hazardous areas

2.3.1 Qualified personnel for hazardous area applications

Qualified personnel for hazardous area applications
Persons who install, connect, commission, operate, and service the device in a hazardous area must have the following specific qualifications:
They are authorized, trained or instructed in operating and maintaining devices and
systems according to the safety regulations for electrical circuits, high pressures, aggressive, and hazardous media.
They are authorized, trained, or instructed in carrying out work on electrical circuits for
hazardous systems.
They are trained or instructed in maintenance and use of appropriate safety equipment
according to the pertinent safety regulations.

2.3.2 Loss of safety of device with type of protection "Intrinsic safety Ex i"

If the device or its components have already been operated in non-intrinsically safe circuits or the electrical specifications have not been observed, the safety of the device is no longer ensured for use in hazardous areas. There is a risk of explosion.
Connect the device with type of protection "Intrinsic safety" solely to an intrinsically safe
circuit.
Observe the specifications for the electrical data on the certificate and/or in Technical
data (Page 39).
SITRANS Probe LR with mA/HART Compact Operating Instructions, 05/2019, A5E46248119-AC
11
3
Note Approval information
Refer to product label for approval information.
Shield length 250 mm (10"): use for long nozzles of 250 mm (10") or less in length
Shield length: 100 mm (4"): use for nozzles of 100 mm (4") or less in length

3.1 SITRANS Probe LR

SITRANS Probe LR is a 2-wire loop-powered, continuous level measuring instrument that utilizes advanced pulse radar technology operating at a frequency of approximately 6 GHz. The instrument consists of an electronic component coupled to the antenna and process connection. It is very easy to install and set up, using either the infrared handheld programmer locally, or using SIMATIC PDM from a remote location.
Communication is via HART. Signals are processed using Process Intelligence which has been field-proven in over 500,000 applications worldwide (ultrasonic and radar).
SITRANS Probe LR is available in two versions
General purpose (non-hazardous)
Intrinsically Safe (with suitable barrier)
Applications
SITRANS Probe LR is designed to measure liquid levels in a variety of applications.
liquid bulk storage vessels
simple process vessels with gentle agitation
liquids
slurries
SITRANS Probe LR with mA/HART
12 Compact Operating Instructions, 05/2019, A5E46248119-AC
Description

3.2 Ambient/operating temperature

3.2 Ambient/operating temperature
Process temperature and pressure capabilities are dependent upon information on the process device tag. The reference drawing listed on the tag can be downloaded from the Siemens website. Go to the SITRANS Probe LR product page at: SITRANS Probe LR (www.siemens.com\probelr
)
SITRANS Probe LR with mA/HART Compact Operating Instructions, 05/2019, A5E46248119-AC
13
4
WARNING
Incorrect disassembly
DANGER
Pressure applications
Note Product designation
This product is designated as a Pressure Accessory per Directive 2014/68/EU and is not intended for use as a safety device.

4.1 Basic safety notes

4.1.1 Incorrect disassembly

The following risks may result from incorrect disassembly:
- Injury through electric shock
- Risk through emerging media when connected to the process
- Risk of explosion in hazardous area
In order to disassemble correctly, observe the following:
Before starting work, make sure that you have switched off all physical variables such
as pressure, temperature, electricity etc. or that they have a harmless value.
If the device contains hazardous media, it must be emptied prior to disassembly. Make
sure that no environmentally hazardous media are released.
Secure the remaining connections so that no damage can result if the process is started
unintentionally.
Danger to personnel, system and environment will result from improper disassembly.
Never attempt to loosen, remove, or disassemble process connection while vessel
contents are under pressure.
SITRANS Probe LR with mA/HART