Siemens RWB2007, RWB1007 User Instructions

s
RWB2007 User instructi on s
Content
Section 1 Introduction and features Section 2 Factory settings Section 3 Setting the On/Off times Section 4 Boost/Advance Section 5 Review Programme Section 6 Setting Clock Section 7 Service Interval*
1. Introduction
The RWB2007 is a 7-day or 5-day-and-2-day twin channel programmer for central heating and hot water.
Features
Large digital backlit display (timeout 5 minutes)
2 or 3 On/Off periods per day
"Advance“ feature to bring forward the next On/Off period
“Boost“ feature to give an immediate one hour On
Automatic summer/winter changeover (summer/winter changeover switch occur s at 02:0 0)
Selectable time formats (24-hour and 12-hour (am/pm))
Built-in calendar
Copy facility
Service Interval capable*
2. Factory settings
Before leaving the factory, the RWB2007 was programmed with the correct date and time with the following switching times de­pendent on the Dip switch setting on the back of RWB (factory default 2 On/Off):
Operating instructions
Switch (1)
: Programming switch. When all program min g has been
done this switch must be in Run. Switch (2): This switch allows you to choose how the
RWB…operates.
Constant: The RWB is permanently ON
ALL DAY: The RWB switches on at the first ON and off at the last OFF.
AUTO: The RWB switches automatically at the programmed
times.
3. Setting the On/Off times
The RWB2007 is supplied with factory settings (see section 2). If you want to change the factory settings to your own times you can do so easily. ON/OFF times are adjustable in 10-minute ste ps.
Setting the central heating
Sliding switch (1) to CH shows all the days of the week with a triangle under Mo. Press YES if you want to program Monday, or press Day until the triangle goes under the required day, then press YES.
Setting times
The first ON time is 06.00. To change the time, press + or –. When you have reached the desired time, press YES. The first OFF time is 08.30. Repeat the process until all times are entered for that day. Note: LIMIT comes in the display if you try to move a programme time forward or backward and it comes up against an existing time.
Copy
Copy YES/NO appears in the display if you want to copy to the next day. Press YES and repeat for each day that you want to be the same. If you don’t want to copy, press NO and then set times for each day. When all programming is complete, slide the switch to RUN.
A6V10464932
Monday - Friday
2 On/Off switching Times
3 On/Off switching Times
On 06.00 Off 08.30
On 06:00 Off 08.30
On 16.30 Off 22.30 On 12.00 Off 14.00
On 16.30 Off 22.30
Weekend
2 On/Off switching Times
3 On/Off switching Times
On 07.00 Off 09.00
On 07:00 Off 09.00
On 16.30 Off 23.00
On 12.00 Off 14.00
On 16.30 Off 23.00
Siemens Building Technologies A6V10464932_enGB_b 2016-07-14 1/2
Issued by Siemens Switz erland Ltd. Building Techn ologies Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24
www.siemens.c om/buildingt echnologies
© Siemens Switz erland Ltd, 2016
Technical specifications and availability subject to change without notice.
Setting the hot water
Sliding switch (1) to HW shows all the days of the week with a triangle under Mo. Press YES if you want to program Monday, or press Day until the triangle goes under the required day, then press YES.
Setting times and copy
Please refer to the instruct ion s above under Setting the central heating.
4. Boost
Pressing this button switches your heating ON for one hour if it’s in an OFF period, or adds an hour if it’s already in an ON period.
Advance
Pressing this button brings forward the next ON or OFF period. This feature only works in AUTO or ALL DAY.
5. Reviewing your programme
Press Review, and then press YES. The first ON with a triangle under Mo appears. Press YES repeatedly until all times have been reviewed for Mo. The tri a ngle then move s to Tue. Do the same for this day and days after it until all the days are reviewed. The RWB2007 goes back to the normal mode if no buttons were pressed within 4 seconds.
6. Setting the time
The RWB2007 comes preset with the correct date and time. Should you need to reset the time for any reason, move the pro­gramming slider to the clo ck s y mb ol: Y appears in the display. Press + or – to change the year. Press YES when the correct value is in the display. Do the same for the month (M), the day (D) and the time (a clock symbol is in the display), and then move the slider to RUN. Note: The RWB2007 is delivered with the 24-hour time format setting. If you want to change it to the 12-hour format (am/pm), press RESET. 24h appears in the display. Press + or – to ch ange it to 12h in the display, then press YES.
7. Service Interval*
In some instances the RWB may have been set with the service interval function. This enabled option is designed to remind the end users of contacting the relevant person to have the annual service carried out on the boiler.
By law, your gas boiler should be inspected/serviced annually to ensure it is working correctly. To help make sure this service is carried out at the correct time, the RWB can have the Service Interval function enabled. This function will be enabled and pro­grammed by your installer, the maintenance engineer, or your landlord.
If it has been set to do so, the RWB will display a message on the screen to remind you that a boiler service is due. This pre­warning countdown will be indicated up to 50 days in advance, which allows enough time to arrange for an engineer. Normal functions continue during t his stage.
The amount of pre-warning days has to be entered by the installer, maintenance en-
gineer, or the landlord. Contact them when you see the warning for the first time. From then the display will switch between the normal display and the amount of re­maining days. The RWB will also emit a 5-second sound hour ly between 09:00 and
21:00.
If the RWB goes past the service day, the system will be switched off with only the one hour “boost“ feature working, and the display will switch between the real time and OFF.
You must press RESET after any change to either the (P) Fully pumped, (G) Gravity or the 2/3 Prg per day switch on the back of RWB. Sliders on the front must be in OFF when changing from (P) Fully pumped to (G) Gravity.
WHAT IS A PROGRAMMER? (an explanation for Householders recommended by the Energy Savings Trust)
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at different times. Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently off. The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Ad­vance’, or ‘Boost’. The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cyl­inder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature.
2/2 2016-07-14 A6V10464932_enGB_b Siemens Building Technologies