Siemens NCC-G16, NCC-16T, NCC-1T-UK, NCC-2T-UK, NCC-3T-UK Installation Instructions Manual

...
FireFinder Upgrade Kits NCC-G16, NCC-16T NCC-1T-UK, NCC-2T-UK, NCC-3T-UK, NCC-4T-UK NCC-GL1
Fire Safety
OPERATION
The FireFinder (NCC) Upgrade Kits expand the operating parameters of an existing NCC system as follows:
• NCC-G16: provides an existing NCC graphics system with the capability to control/monitor additional 16 MXL panels
• NCC-16T: provides an existing NCC text system with the capability to control/monitor additional 16 MXL panels
• NCC-1T-UK allows an existing NCC-1T (16 node/text) to upgrade to a NCC-1G (16 node/ graphics)
• NCC-2T-UK allows an existing NCC-2T (32 node/text) to upgrade to a NCC-2G (32 node/ graphics)
• NCC-3T-UK allows an existing NCC-3T (48 node/text) to upgrade to a NCC-3G (48 node/ graphics)
All FireFinder (NCC) upgrade kits are compatible with both the NCC OS/2 version and NCC NT™ version. The minimum NCC software revision required to recognize the NCC software upgrade keys is 2.23 for the OS/2 version and 4.01 for the NT™ version.
FireFinder Upgrade Kits include an NCC Upgrade Software Key and NCC Manual (not included with the NCC-16 or NCC-GL1 series). The existing NCC components such as NCC software program, keyboard templates, and NCC-1F card remain the same.
INSTALLATION
1.Your existing NCC computer should have the original NCC software key plugged into the LPT 2 port as shown in Figure 1 on the next page.
2.Insert your NCC upgrade software key directly into the existing NCC software key. Secure key connection with screw terminals. See Figure 2 on the next page.
• NCC-4T-UK allows an existing NCC-4T (64 node/text) to upgrade to a NCC-4G (64 node/ graphics)
• NCC-GL1 allows an existing NCC-GL system to upgrade to a NCC-1G (16 node/graphics)
Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, New Jersey 07932
P/N 315-096334-2
3.Once the NCC upgrade software key is securely attached to the original NCC software key, reboot the computer.
Siemens Building Technologies, Ltd. 2 Kenview Boulevard Brampton, Ontario L6T 5E4 CN
120 VAC
(NCC Key)
LPT PORT 2
60 Hz
Flexible Conduit
To Parallel Printer
See Notes 3 and 5
AC Main
120 VAC 60Hz
(User Supplied)
Junction
Box
(user
supplied)
Conduit
Figure 1 Original NCC Software Key Placement
Monitor
(rear view)
Touch
Port A
Interface
See Notes 3 and 4
Computer (rear view)
LPT1
Ethernet
Sound
Card
See Notes 1, 2, 3, 4, and 5
*The COM port on the Main
CPU must be disabled if NCC-1F is being used. See Note 13
VIDEO
Keyboard
SCD19TM or SCD21TM
6
5
4
Mouse
3
2
1
LPT PORT 2
COM 2
Elo TouchScreen
Controller Card
See Note 14
1 2 3 4 5 6 7 8
(NCC Key)
NOTES:
1. NCC-1F card is installed in a 16-bit ISA slot and is set for COM2.
2. Connect the keyboard and mouse to the computer's keyboard and mouse ports following the computer's installation instructions.
3. NFPA 72 Proprietary and Local System installation requires that the computer, monitor, and printer be UL rated for fire (SIEMENS Models SCD550, SCD550T, SCD19M, SCD19TM, SCD21M, SDC21TM and PAL-1, respectively).
4. The computer is supervised for power and connection to MXL.
5. The printer is supervised for AC, on/off line, paper out, paper jam, and connec­tion to the computer by NCCNT-G software at the computer.
6. All circuits are power limited.
7. Cable must be in rigid conduit and cannot leave the room.
8. Shielded cable is not recommended.
9. Power limited to NFPA 70 per NEC 760.
10.Maximum voltage: 24V peak to peak.
11.Maximum current: 20mA per circuit.
12.LPT2 has software key.
13.The COM Port on the Main CPU is disabled. The Serial Port on the Serial Parallel Adapter card takes on the identification of COM1. The NCC-1F card is identified as COM2.
14.If you are using model SCD-19M, the touch screen controller card is not installed.
15.Pin 1 & 2 of the LPT2 board can be wired to a TRI module to monitor the status of the computer's CPU.
Figure 2 Connecting The Upgrade NCC Software Key To The Existing NCC Software Key
2