Siemens Landis & Staefa REV11 Series Operating Instructions Manual

Operating instructions
Landis & Staefa REV11…
REV11… - the temperature controller that allows you to set the ideal room temperature at the time you want. There are two switching patterns available that can be set to suit your specific needs. You can either rely on the factory settings or make settings tailored to your personal needs.
Setting slider
Display
Settings
Time of day
Room temperature
(measured)
Time of day
Remote operation active (if connected)
Standby
Normal temperature
Heating on
Economy temperature
Replace batteries
°C
1.5V 'AA'
1.5V 'AA'
Operation
Continuous normal temperature
Continuous economy temperature
Standby
with frost protection
Operating mode selector
Change
between normal and economy mode up to the next switching point
Warmer/colder setting
valid up to the next switching point (increments of 0.2 ºC, ± 4 ºC max.)
24-hour mode A
with 2 heating periods
Auto
Run
A1 A2 A3 A4
B1 B2
Operating position
Auto
Run
Economy temperature
Normal temperature
Switching times B1...B2
B1
B2
Switching times A1...A4
A1
A2 A3 A4
2222Z11E
24-hour mode B
with 1 heating period
A
B
Commissioning with quick startup
The controller is supplied with factory-set switching patterns, switching times and temperatures. To commission it, proceed as follows:
1.5V 'AA'
1.5V 'AA'
Remove the black transit tabs from the two batteries. Check to see if the battery holder is in its correct position. The controller switches itself on.
Move the setting slider to the time position. Press buttons to set the correct time of day.
Auto
Run
Move the setting slider back to position on the right, because only that position allows you to close the cover.
A
Select the required operating mode with the operating mode selector (e.g.
A
).
Fold up the operating instructions again, place them back into the cover and close the cover again.
Do you want to use automatic operation?
If that is the case, set the operating mode selector to one of the following positions:
A
You use the 24-hour setting A with
two
heating periods.
B
You use the 24-hour setting B with
one
heating period.
Do you require continuous normal temperature?
Move the operating mode selector to «Normal temperature». This ensures continuous heating to the normal temperature. The display
shows
.
Do you require continuous economy temperature?
Move the operating mode selector to «Economy temperature». This ensures continuous heating to the economy temperature. The display shows
.
Do you require continuous standby with frost protection?
Move the operating mode selector to «Standby». In that case, heating is provided only when the room temperature falls below the preset frost protection limit (5 °C). The
display shows
.
Do you feel too warm or too cold?
°C
By pressing these buttons, you increase or decrease the actual room temperature in increments of
0.2 °C by a maximum of ± 4°C. The display first shows the newly selected temperature and then the actual value again.
These changes are valid only up to the next switching point.
If, as a result of the factory settings, you always feel either too warm or too cold, you should readjust the
temperature
or to suit your
needs
.
CE1B2222E / 27.01.1999 Subject to alteration Siemens Building Technologies / Landis & Staefa Division
Do you want to change the temperature level or will you be absent for a short period of time?
When pressing this button, you change from the current temperature level to the other. The
display shows either
, when the change was made from the economy temperature, or
, when it was made from the normal temperature. This means you can select the economy temperature during the time you are absent.
These changes are valid only up to the next switching point.
Do you want to enter your own temperatures and heating periods?
The controller has two different switching patterns (A/B).
Proceed as follows:
A1
Move the setting slider to the switching position (e.g. A1) and
press
to enter the required
switching time.
All the other switching positions (A2…A4 and B1…B2) are set the same way.
Select «Normal temperature» and press
to set the required value.
Select «Economy temperature» and press
to set the required
value.
Auto
Run
Move the setting slider back to this position and close the cover.
Table for entering selected values
Enter the values set by you in the following table. The numbers already contained in the table represent factory settings.
Temp.Switching times
A1 A2
A3
A4 B1 B2
6.00 9.00 17.00 22.00 7.00 23.00 20° C 16° C
2222Z12E
Do you need to change the time of day?
Move the setting slider to the time of day position and press
to
set the correct time of day.
Auto
Run
Move the setting slider back to this position and close the cover.
Do you wish to return to the factory settings?
°C
By pressing these three buttons simultaneously, a complete reset is made, which means that the switching times and temperatures will be reset to their default values.
Caution: all individual settings will be lost!
At the same time, a display check is made, which looks as follows:
2222Z13
Does the symbol appear in the display?
If this symbol appears, you need to replace the batteries within the next three months.
Do you want to change the batteries?
Get two new alcaline batteries type AA,
1.5 V.
Remove the battery holder, then the batteries, insert the new batteries and replace the battery holder.
Caution: The setting data are maintained fora maximum of one minute only!
Make certain the old batteries are disposed of properly, in compliance with environmental requirements.
Energy saving tips without sacrificing comfort
Never allow room temperatures to exceed 21 °C.
Press
to change to economy temperature, even if you are absent for short periods of time only.
Air out the rooms for short periods of time only, but properly, with the windows wide open.
Auxiliary functions
Your room temperature controller provides a number of auxiliary functions, but these should only be set by your heating engineer.