Siemens CHSL4010,CHSL4011 Installation Manual

Building Technologies
Fire Safety & Security Products
CHSL4010 CHSL4011
Large Camera Housing
Installation Guide
Data and design subject to change without notice. / Supply subject to availability. © 2008 Copyright by Siemens Building Technologies
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
3
Siemens Building Technologies
Fire Safety & Security Products 09.2008
Contents
1 Safety .......................................................................................................5
1.1 Target group..............................................................................................5
1.2 General safety precautions ....................................................................... 5
1.3 Meaning of the signal words .....................................................................6
1.4 Meaning of the hazard symbols ................................................................6
2 EU Directives ...........................................................................................7
3 Technical data .........................................................................................8
3.1 Specifications ............................................................................................ 8
3.2 Mechanical dimensions............................................................................. 9
3.3 Key to Parts...............................................................................................9
4 Scope of delivery ..................................................................................10
5 Mounting ................................................................................................11
5.1 Adjusting the Sunshield ..........................................................................11
5.2 Accessing the inside of the Housing Enclosure......................................11
5.3 Mounting the Camera and Lens Assembly.............................................12
5.4 Mounting the Camera Housing Assembly ..............................................13
5.5 Connecting to the Power Supply.............................................................14
6 Maintenance and service .....................................................................16
7 Disposal .................................................................................................16
Safety
5
Siemens Building Technologies
Fire Safety & Security Products 09.2008
1 Safety
1.1 Target group
The instructions in this document are designed only for the following target group.
Target readers Qualification Activity Condition of the
product
Installer Technical training for
building or electrical installations.
Installs the product, individual components of the product or replacement parts.
Components of the product are not yet installed or need to be replaced or modified.
1.2 General safety precautions
z Read the general safety precautions before operating the device.
z Follow all warnings and instructions marked on the device.
z Keep this document for reference.
z Always pass this document on together with the product.
z Please also take into account any additional country-specific, local safety
standards or regulations concerning project planning, operation and disposal of the product.
z It is recommended that all preparatory work (e.g. fitting of accessories) be
carried out in a workshop prior to final installation.
Liability claim
z Do not connect the device if it is damaged or any parts are missing.
z Do not make any changes or modifications to the device unless they are
expressly mentioned in this manual and have been approved by the manufacturer.
z Use only spare parts and accessories that have been approved by the
manufacturer.
Risk of failure due to incorrect installation
z The fuse for the device and the fuse for the electrical system of the building must
be installed separately.
Risk of cable damage due to stress
z Use only cable types that are approved for the environmental requirements.
z The cable glands used must be appropriate for the cable diameter.
Safety
6
Siemens Building Technologies
Fire Safety & Security Products 09.2008
1.3 Meaning of the signal words
The severity of a hazard is indicated by the following written warning notices.
Signal word Type of hazard
CAUTION There is a risk of minor to medium injuries or damage to property
IMPORTANT Malfunctioning may result
1.4 Meaning of the hazard symbols
The nature of the hazard is indicated by icons.
Warning of a hazard
EU Directives
7
Siemens Building Technologies
Fire Safety & Security Products 09.2008
2 EU Directives
The product complies with the requirements of the following EU directives. The EU declaration of conformity is available from:
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG 76181 Karlsruhe
Germany
EU Directive 2004/108/EC on electromagnetic compatibility
Conformity with the European Directive 2004/108/EC is demonstrated by compliance with the following standards:
Emitted interference: EN 61000-3-2
EN 61000-3-3 EN 55022 Class B
Resistance to interference: EN 50130-4
EU Directive 2006/95/EC “Low-Voltage Directive”
Compliance with the European Directive 2006/95/EC has been proven by testing according to the following standard:
Safety: EN 60950-1
Technical data
8
Siemens Building Technologies
Fire Safety & Security Products 09.2008
3 Technical data
3.1 Specifications
Nominal Voltage
CHSL4010: 110 – 230 V AC, 50/60 Hz
CHSL4011: 12 – 24 V AC, 50/60 Hz
Fuse Rating (Fuse F1)
CHSL4010: 2 A 250 V AC 5 x 20 Type (T), HBC
CHSL4011: 5 A 250 V AC 5 x 20 Type (T), HBC
Electrical Connections
Main supply connections via fused PCB mounted terminal blocks. Use crimped ferrules when terminating cables.
6 way pillar terminal block available for user connections.
Cable Entry
1 x 25 mm hole to accept conduit (fitted with blanking plug).
1 x 16 mm Cable Gland
(5 – 10 mm diameter cable range)
2 x 20 mm Cable Glands
(6 – 12 mm diameter cable range)
Heater 7 W nominal, 25 W max.
PTC resistor heating element, thermostatically controlled.
Environmental
Operating Temperature -20 to +60 °C (-20 to +40 °C when wiper kit fitted)
Ensure fitted equipment has suitable temperature range for the application (e.g. maximum typical ambient operating temperature of camera and lens. Ta = 40 °C).
Maximum internal dissipated power 50 W (25 W (including wiper motor) when wiper kit fitted)
Relative humidity Up to 95 % non-condensing
Weatherproof rating IP66, BS EN 60 529
Material Toughened Glass Window
Aluminium extrusions (Housing body / Sunshield)
Die cast aluminium (front and rear end caps)
Finish Endcaps: Polyester powder coat, RAL7016 Grey
Housing Body: Polyester powder coat, RAL9006 White Aluminium
Sunshield: Polyester powder coat, RAL9006 White Aluminium
Internal Dimensions (L x W x H) 400 x 125 x 110 mm
Usable Height with Wiper fitted 88 mm
Weight Including Sunshield: 6.0 Kg
Excluding Sunshield: 4.9 Kg
Suitable Pan and Tilt Units CDD2425, CDD2416-T, CDAP2316-T, CDAP2416-T
Suitable Brackets CHBS2815, CDBS4540 + CAHA1040
Technical data
9
Siemens Building Technologies
Fire Safety & Security Products 09.2008
3.2 Mechanical dimensions
Fig. 1 Mechanical dimensions
1 168 mm
2 143 mm
3 82.5 mm
4 100 mm
5 155 mm
6 627 mm
7 609 mm
8 559 mm
9 596 mm
10 149 mm
3.3 Key to Parts
1 2 3 4
5679 8
10
Fig. 2 Key to Parts
1 Front End Cap 6 Cable Anchor
2 Housing Body 7 Terminal Board
3 Sunshield 8 Camera Mounting Plate
4 Rear End Cap 9 Demister Assembly
5 Cable Glands 10 Window
Scope of delivery
10
Siemens Building Technologies
Fire Safety & Security Products 09.2008
4 Scope of delivery
z Installation Guide
z Camera fixing screw (1/4” BSW x ½” hex hd.)
z Camera fixing screw (1/4” BSW x ¾” hex hd.)
z 4 x M6x12 mm socket cap head screws
z 4 x M6 washers
z Spacer block (1.6 mm thick)
z Spacer block (3 mm thick)
z Spacer block (6.3 mm thick)
z 3 mm (across flats) ALLEN key
z Shoulder washer (to insulate screw from camera mounting plate)
NOTE
The complete assembly should be mounted and tested in the workshop prior to use on-site.
Accessories
Type Designation
CAHL4010-WK 230 V AC Wiper Kit
CAHL4011-WK 24 V AC Wiper Kit
CAHL401X-WK Spare Wiper Arm Assembly
CAHL4010-WU 230V AC Washer Unit
CAHL4011-WU 24V AC Washer Unit
CAPD1210-C230 12 V DC 500 mA PSU 230 V AC input
Mounting
11
Siemens Building Technologies
Fire Safety & Security Products 09.2008
5 Mounting
5.1 Adjusting the Sunshield
1. Firmly squeeze (A) the sides of the sunshield (See Fig. 3).
2. Slide (B) the sunshield to the required position.
3. Release the sunshield and it will remain in position.
Fig. 3 Sunshield adjustment
5.2 Accessing the inside of the Housing Enclosure
1. Using the ALLEN key provided, loosen but do not completely remove the
4 securing screws (A) (See
Fig. 4).
2. Slide the housing cover forwards (B).
3. Disconnect the earth wire from the terminal board (C).
4. Allow the cover to pivot at the end or twist to completely remove (D).
NOTE
To re-assemble carry out steps 1 to 4 in reverse, making sure the earth wire is reconnected. The screws which secure the housing to the rear cap should be retightened to a torque of 2 Nm.
Fig. 4 Inside the housing enclosure
1 Rear End Cap
Mounting
12
Siemens Building Technologies
Fire Safety & Security Products 09.2008
5.3 Mounting the Camera and Lens Assembly
1. With the housing cover slid forward or removed, slacken the Pozi Pan Head
Screw, but do not remove (A) (see
Fig. 5).
2. Push the plate to unclip it from the rail (B).
3. Pull back the plate to release it from the rail (C).
4. Secure the camera to the plate, as per the manufacturer’s instructions
(screws suitable for most cameras are supplied with the housing). The nylon shoulder washer can be used on the mounting screw for the camera to insulate it from the housing.
5. Use the spacers provided to adjust the height of the camera and lens on the plate, the lens should be centralised on and close to the window glass when mounted in the housing.
6. Reattach the plate (D) following Steps 1 to 3 in reverse.
7. Wire the camera and lens as described in the manufacturer’s instructions, see
section
5.5 for details on connecting to the power supply. Use the cable
anchors to clamp all cables.
8. Once the camera installation and wiring is complete, close the housing as described in section
5.2.
Fig. 5 Mounting the Camera and Lens Assembly
Mounting
13
Siemens Building Technologies
Fire Safety & Security Products 09.2008
5.4 Mounting the Camera Housing Assembly
The housing has a set of 4 x M6 x 10 mm deep tapped holes on a 101.6mm (4”) PCD for mounting the camera housing to a bracket. Ensure the screws used to mount the housing to a bracket do not bottom out in the mounting holes by being too long.
1. Screw the mounting bracket to the base of the unit (A) (see
Fig. 6).
2. Secure the assembly following the bracket installation instructions.
Fig. 6 Mounting the Camera Housing Assembly
Mounting
14
Siemens Building Technologies
Fire Safety & Security Products 09.2008
5.5 Connecting to the Power Supply
IMPORTANT
Please read the ‘Safety’ section on Page
5 before connecting to the Power
Supply.
IMPORTANT
All wiring must be installed to local and national standards. Ensure all SELV and signal wiring is kept away from live parts and is suitably protected from live parts by double insulation.
CAUTION
A readily accessible all-pole disconnect device with at least 3 mm contact separation shall be incorporated in the building installation wiring. As part of the building installation, protect the unit via a fuse or circuit breaker rated at 2 A for CHSL4010 110 – 230 V AC units and 5 A for CHSL4011 12 – 24 V AC units.
NOTE
Use only cable suitable for the application and that meets the standards required by the installation. The conductor size for power cable(s) must be at least 0.75 mm
2
. The maximum recommended
conductor size is 1.5 mm
2
.
1. Select the most suitable cable gland entry, (see section 3.1 for sizes) and remove the blanking plug supplied in the gland (A) (See
Fig. 7).
2. Insert the mains cable and clamp it securely using one of the cable anchors (B). The central anchor point is for larger cables, the two outer ones are for
smaller cables. Do not overtighten the screws as this may damage the cable.
3. Connect to the input supply on terminal board (C).
Indicator Description
L Live (Brown)
N Neutral (Blue)
E Earth (Green/Yellow)
4. Tighten all glands/conduits (A) securely to prevent water ingress.
C
A
B
Fig. 7 Power cable entry
Mounting
15
Siemens Building Technologies
Fire Safety & Security Products 09.2008
Fig. 8 Terminal board connection details
1 Ancillary Connections Block
2 Fused Output
3 Earth (Gnd)
4 Input Supply Terminal
5 Fuse F1
2 A 250 V AC 5x20 Type (T), HBC for T462
5 A 250 V AC 5x20 Type (T), HBC for T463
6 Heater Output (pre-wired and connected through fuse F1)
Maintenance and service
16
Siemens Building Technologies
Fire Safety & Security Products 09.2008
6 Maintenance and service
The following maintenance guidelines should be observed.
Cleaning Use only soap and water to clean the housing and pane - no abrasive solvents. Additional protection
can be applied to the pane to reduce contamination and droplet formation from moisture or rain. Products from the automotive or cleaning industry which use nanotechnology to reduce surface energies and thus contamination and moisture build-up can be used for this purpose.
6 monthly checks 1. All fastenings and cables should be checked for tightness and wear.
2. Regular checks should be performed to ensure that the outer sheaths of the cables are not damaged and that the cables are not fouling on any obstruction.
NOTE
This installation guide cannot cover all conceivable cases of installation, operation or maintenance. Should you require further information or should special problems occur which are not discussed in adequate detail in the installation guide, please request the required information from your local Siemens office.
We must also point out that the contents of this installation guide do not constitute a part of an earlier or existing agreement. Neither do they constitute or amend any earlier or existing commitment or legal relationship. All obligations on the part of Siemens result from the relevant purchase agreement which also contains the complete and solely valid warranty regulations. This installation guide neither extends nor restricts these contractual warranty regulations.
7 Disposal
All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities.
This crossed-out wheeled bin symbol on the product means the product is covered by the European Directive 2002/96/EC.
The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and electronic equipment. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product.
Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe
www.buildingtechnologies.siemens.com
© 2008 Copyright by
Siemens Building Technologies
Data and design subject to change without notice.
Supply subject to availability.