Technical data
8
Siemens Building Technologies
Fire Safety & Security Products 09.2008
3 Technical data
3.1 Specifications
Nominal Voltage
CHSL4010: 110 – 230 V AC, 50/60 Hz
CHSL4011: 12 – 24 V AC, 50/60 Hz
Fuse Rating (Fuse F1)
CHSL4010: 2 A 250 V AC 5 x 20 Type (T), HBC
CHSL4011: 5 A 250 V AC 5 x 20 Type (T), HBC
Electrical Connections
Main supply connections via fused PCB mounted terminal blocks.
Use crimped ferrules when terminating cables.
6 way pillar terminal block available for user connections.
Cable Entry
1 x 25 mm hole to accept conduit (fitted with blanking plug).
1 x 16 mm Cable Gland
(5 – 10 mm diameter cable range)
2 x 20 mm Cable Glands
(6 – 12 mm diameter cable range)
Heater 7 W nominal, 25 W max.
PTC resistor heating element, thermostatically controlled.
Environmental
Operating Temperature -20 to +60 °C (-20 to +40 °C when wiper kit fitted)
Ensure fitted equipment has suitable temperature range for the
application (e.g. maximum typical ambient operating temperature of
camera and lens. Ta = 40 °C).
Maximum internal dissipated power 50 W (25 W (including wiper motor) when wiper kit fitted)
Relative humidity Up to 95 % non-condensing
Weatherproof rating IP66, BS EN 60 529
Material Toughened Glass Window
Aluminium extrusions (Housing body / Sunshield)
Die cast aluminium (front and rear end caps)
Finish Endcaps: Polyester powder coat, RAL7016 Grey
Housing Body: Polyester powder coat, RAL9006 White Aluminium
Sunshield: Polyester powder coat, RAL9006 White Aluminium
Internal Dimensions (L x W x H) 400 x 125 x 110 mm
Usable Height with Wiper fitted 88 mm
Weight Including Sunshield: 6.0 Kg
Excluding Sunshield: 4.9 Kg
Suitable Pan and Tilt Units CDD2425, CDD2416-T, CDAP2316-T, CDAP2416-T
Suitable Brackets CHBS2815, CDBS4540 + CAHA1040