Siemens ARCADIS Orbic Installation manual

Würthwein
ARCADIS Orbic
Installation and Startup
System
SP
3D Navigation
08080009
Print No.: Replaces: SPR2-320.814.03.01.02
SPR2-320.814.03.02.02
© Siemens AG
The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
English Doc. Gen. Date: 06.05
2005

2 Revision / Disclaimer

1Revision / Disclaimer
Document revision level
The document corresponds to the version/revision level effective at the time of system delivery. Revisions to hardcopy documentation are not automatically distributed.
Please contact your local Siemens office to order current revision levels.
Disclaimer
The installation and service of equipment described herein is to be performed by qualified personnel who are employed by Siemens or one of its affiliates or who are otherwise authorized by Siemens or one of its affiliates to provide such services.
Assemblers and other persons who are not employed by or otherwise directly affiliated with or authorized by Siemens or one of its affiliates are directed to contact one of the local offices of Siemens or one of its affiliates before attempting installation or service pro­cedures.
ARCADIS Orbic SPR2-320.814.03.02.02 Siemens AG
06.05 CS SD 24
Page 2 of 16
Medical Solutions
Table of Contents 3
1- 0Table of Contents
1 _______ Prerequisites ___________________________________________________ 4
3D navigation with the ARCADIS Orbic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Required documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
System requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Required parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Required license key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Functional check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 _______ Installation and settings __________________________________________ 7
Work sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing the TCP/IP cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Attaching the HW interface to the image intensifier . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Attaching the identification label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Configuring the network node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Final work steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3 _______ Changes to the previous versio ___________________________________ 15
Siemens AG SPR2-320.814.03.02.02 ARCADIS Orbic Medical Solutions
06.05 CS SD 24
Page 3 of 16

4 Prerequisites

1Prerequisites
2-

3D navigation with the ARCADIS Orbic 0

Fig. 1: Navigation systems
Fig. 2: 3D_marker ring
The 3D navigation kit is a universal HW and SW interface which serves navigation sys­tems from different navigation companies (Fig.1/p.4).
The navigation system itself is supplied by a navigation company.
The supplied grid holder on the image intensifier is usually the interface to the “removable marker ring”. An engineer from the navigation company is responsible for attaching the active or passive marker ring (Fig.2/p.4) to the I.I. of the Is C 3D.
ARCADIS Orbic SPR2-320.814.03.02.02 Siemens AG
06.05 CS SD 24
Page 4 of 16
Medical Solutions
Prerequisites 5
A Siemens engineer is responsible for attaching the grid holder to the image intensifier, testing and loading the SW, calibration without the marker ring on the I.I., as well as con­figuration.
An additional calibration must be performed with the navigation system installed (marker ring on the I. I.). Therefore, an engineer from the navigation company must be participate in the calibration.
Two engineers use a test body to check the interaction of the two systems and the overall accuracy.
The test body always remains with the customer.
The overlap time of the two engineers is approx. 2 hours.
The navigation system is handed over by the navigation company.

General requirement 0

Support for startup from the navigation company should be provided on site.

Required documents 0

System configuration SPR2-320.843.02.01.02
Image quality test SPR2-320.820.02.01.02

System requirement 0

ARCADIS system software VB11 or higher.

Required parts 0

TCP/IP type cross-over cable for a direct connection to the navigation system (not included in the shipment).
TCP/IP cable for a connection to the navigation system via the clinical network (not included in the shipment).
3D navigation kit: 80 81 452

Required license key 0

3D navigation license key Part No.: 80 81 528
3D license key Part No.: 80 81 502
Siemens AG SPR2-320.814.03.02.02 ARCADIS Orbic Medical Solutions
06.05 CS SD 24
Page 5 of 16