The reproduction, transmission or use
of this document or its contents is not
permitted without express written
authority. Offenders will be liable for
damages. All rights, including rights
created by patent grant or registration
of a utility model or design, are
reserved.
English
Doc. Gen. Date: 04.07
2007
2Revision / Disclaimer
1Revision / Disclaimer
Document revision level
The document corresponds to the version/revision level effective at the time of system
delivery. Revisions to hardcopy documentation are not automatically distributed.
Please contact your local Siemens office to order current revision levels.
Disclaimer
The installation and service of equipment described herein is to be performed by qualified
personnel who are employed by Siemens or one of its affiliates or who are otherwise
authorized by Siemens or one of its affiliates to provide such services.
Assemblers and other persons who are not employed by or otherwise directly affiliated
with or authorized by Siemens or one of its affiliates are directed to contact one of the
local offices of Siemens or one of its affiliates before attempting installation or service procedures.
SIREMOBIL/ARCADISSPR2-130.841.04.01.02Siemens AG
04.07CS PS SP
Page 2 of 24
Medical Solutions
Table of Contents3
0Table of Contents
1 _______ General ________________________________________________________ 4
3 _______ Changes to previous version _____________________________________ 24
Siemens AGSPR2-130.841.04.01.02SIREMOBIL/ARCADIS
Medical Solutions
04.07CS PS SP
Page 3 of 24
4General
Safety Instructions0
1-1General
General safety information (in existing documents)0
WARNING
Mechanical safety information0
CAUTION
Danger of injuries, death or material damage.
Note
¹ the product-specific safety notes in these instructions,
¹ the general safety information in TD00-000.860.01... and
¹ the safety information in accordance with ARTD part 2.
¹ Non-compliance can lead to death, injury or material
damage.
Risk of burns from hot parts or components! Failure to observe
may result in minor to more severe burns, especially on the
hands.
CAUTION
Parts and components (e.g., power components, cooling fins,
electromagnetic brakes) that can exceed 50 degrees Celsius during operation are accessible after the covers are opened.
¹ To avoid burns, switch the system off prior to touching
parts or components and allow at least 5 minutes for
cooling.
Risk of injury from mechanical parts! Failure to observe may
result in minor to more severe injury, especially to the hands.
Once the cover panels are opened, parts such as flat plugs,
threaded bolts, cut-off cable ties and component edges are
exposed. If you are not careful, these can cause crushing,
scrapes and cuts to the skin, particularly to the hands.
¹ Perform the required work with special care and attention
to detail.
¹ If necessary, wear work gloves.
SIREMOBIL/ARCADISSPR2-130.841.04.01.02Siemens AG
04.07CS PS SP
Page 4 of 24
Medical Solutions
General5
Safety information - risk of infection0
WARNING
Risk of infection due to pathogens! Non-compliance can lead to
severe injury and even death.
This product can be contaminated by infected blood or other
bodily fluids.
¹ Avoid all contact with blood or other bodily fluids!
¹ Strictly observe the safety information in
ARTD-002.731.37... regarding prevention of infectious
diseases during customer service calls.
Siemens AGSPR2-130.841.04.01.02SIREMOBIL/ARCADIS
Medical Solutions
04.07CS PS SP
Page 5 of 24
6General
Required Parts, Test Equipment, Tools and Aids1.1
Required Parts0
Foot brake repair set, material number 71 41 190
Fig. 1:Foot brake repair set
Pos. 1Top part of brake bolt
Pos. 2Allen screws for securing the top part of the brake bolt
Pos. 3Lower part of brake bolt rust-free
Pos. 4Pressure springs
Pos. 5Sleeve bearing
Pos. 6Allen screws rust-proof
Included in the repair set, not shown in the photo: Hex head rod approx. 800 mm in length
Required tools0
Standard tool kit
1 set of Allen wrenches
Angled gaspipe pliers
Hacksaw (bow saw)
SIREMOBIL/ARCADISSPR2-130.841.04.01.02Siemens AG
04.07CS PS SP
Page 6 of 24
Medical Solutions
General7
Required aids0
Wooden block ca. 12cm x 14cm x 20cm (Width x Height x Length).
Loctite 242, material number 34 69 046
Mobil EPIX lubricant, material number 34 91 271
If required (oxidation damages), also needed:
Waterproof sandpaper, granulation 400
Waterproof sandpaper, granulation 800
Cleansing cloth (paper or cloth)
SIREMOBIL Compact/ Compact L Paint spray Medium Basic, material number 40 04 243
Siemens AGSPR2-130.841.04.01.02SIREMOBIL/ARCADIS
Medical Solutions
04.07CS PS SP
Page 7 of 24
8General
Number of persons required1.2
During the repair work, the side beam of the transport frame has to be lifted and supported by a wooden block in order to make it possible to assemble/disassemble the
wheels and brake parts.
To do this, two people are temporarily needed (for just a few minutes).
To remove the old brake bolts from the sleeve bearing, especially if they are already oxidized in the sleeve bearing, it is also helpful to have two people.
SIREMOBIL/ARCADISSPR2-130.841.04.01.02Siemens AG
04.07CS PS SP
Page 8 of 24
Medical Solutions
Loading...